Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC | ₹45.2 L Quoted ₹45.3 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹46.5 L+₹1.1 L (2.46%)Rejected-Finance 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | ₹46.5 L+₹1.1 L (2.46%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹48.8 L+₹3.5 L (7.63%)Rejected-Finance | ₹48.8 L+₹3.5 L (7.63%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹49.1 L+₹3.7 L (8.19%)Rejected-Finance SR NO 281 3 7 ANAND NAGAR NEAR DHANORI JAKAT NAKA LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | ₹49.1 L+₹3.7 L (8.19%) | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹54.0 L+₹8.6 L (19.1%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹54.0 L+₹8.6 L (19.1%) | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | G K CONSTRUCTIONS L2 | B5BUILDING SOLUTIONS L3 | Lucky Enterprises L5 | KRD ASSOCIATE L1 | M/s Rohit Construction Co. L6 | VP DEVELOPERS AND CONTRACTOR L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Design, supply, install, testing and commissioning of free burning type incinerator for trash waste only (Design Criteria is Minimum 1.2 and below 1.5 seconds of residence time in MCC chamber). The MCC 20 Kgs/hr capacity with sustaining temperature of 650 degree Celsius, the chamber shall be internally bifurcated to achieve the specified residence time, volume of the internal chamber shall be 2.5 cubic mtr ± 0.2 before refractory lining. MCC Chamber outer shell shall be MS sheet of 5 mm thick. MCC Chamber outer shell shall have 50x8 mm flat as stiffeners vertically & horizontally placed all around the shell for structural stability, top end of the chamber shall have one line of angle stiffeners 50x50x6 mm placed horizontally , burning chamber inner wall surface shall have 70% high alumina Refractory fire bricks as heat resistance insulation lining and castable slabs for supports and top cover of the shell of 75 mm thick, reinforcement stainless steel anchoring of 45 mm length is required before casting the refractory slabs, the burning chamber shall have perforated air vent holes on two side of burning chamber only. similarly burning chamber shall have a port for inserting a thermo couple, the System Shall have rigid bottom base frame of ISMC100, waste loading door size approx. 755 x 530 mm with toggle clamp arrangement | 1 | EACH JOB | 29,00,000 ₹29,00,000 | 32,50,000 ₹32,50,000 | 32,86,000 ₹32,86,000 | 28,00,000 ₹28,00,000 | 38,00,000 ₹38,00,000 | 27,00,000 ₹27,00,000 Lowest |
| 1.01for locking, ash removal doors size 350x200 mm with locking arrangement & ash tray size 600 x 450 mm, Poker for removing ash & flame torch with handle for manual firing consisting of the following :-. (a) One No. Wet Scrubbing SS Tray Type system: One No. Wet Scrubbing System with SS Tray: Design, Supply, install, testing & commissioning of Wet Scrubbing system with volume of 1.20 Cubic mtr ± 0.2 and with wall thickness of 2.5 mm, the material grade shall be SS 304, HR. Scrubber tray SS304 and 2.5mm thick Shall have a tilt for smooth flow water and create a screen wall for complete scrubbing. Minimum three tray is recommended. The Structural Supports Legs shall be of Mild Steel 2062 material ISMC100 Channel of 5mm thick & flats 50x8 thIck as stiffeners for structural stability of scrubber shell. Inlet duct to scrubber shall be MS 450mm dia and duct wall thickness is 2.5 mm with 40mm refractory lining thick inside duct with 70% high alumina refractory castable, the following shall have SS reinforcement anchors 45mm length inside the duct, outlet duct of scrubber shall be of SS 304 250mm dia and duct wall thickness 2.5mm, scrubbing media is water and the water flow shall have the ratio at 50 to 70 ltr /hr spraying | |||||||||
| 1.02arrangement system with SS 304 material pipe of 1 inch dia of suitable lengths, 1HP, 3 phase, 440 volts, 50 Hz, pump set of MS casting body and 1 inch MS GI coated pipes to suitable lengths and 1 inch ball valves, NRV, pressure gauge, elbow, T joint fittings, internal cabling with supports shall be provided. (b) ID Fan Blower: Design and supply of MS casing blower, DD/ID, install, testing & commissioning of ID Fan motor 1 HP motor casting body, 3Phase supply, 1440 RPM, blower shall be direct drive foot mount and outlet maintain 45 degree angular, air flow capacity of 500 to 600cubic mtr/hr, including PVC aluminium 4 core armoured power cable 10 sq.mm complete all as directed. | |||||||||
| 1.03Inter Connecting Exhaust Duct : Design, Supply, install, testing & commissioning of Inter connecting ducts material of SS 304 and having 250 mm diameter and wall thickness of 2.5mm with a suitable length to connect from Blower to the chimney, the duct connecting to chimney shall have expansion bellow placed to avoid blower vibration to the duct & chimney. Similarly outlet duct from scrubber connecting to blower shall also have the expansion system below placed. The exhaust duct connecting the chimney cone area shall have insulated 50 mm thick refractory castable with SS reinforcement all as specified and as directed. | |||||||||
| 1.04Self Supporting Chimney : Design, Supply, install, testing & commissioning of self supporting chimney total height of 10 Mtrs from ground level, the material mild steel cone base shall have 800mm diameter with base plate of 16 mm thick and cone height of 3 mtr from GL with MS 8 mm wall thickness, the balance straight chimney duct shall be SS 304 2.5 mm wall thickness 300mm diameter, access ladder upto the height of 4.0 mtrs with platform of foundation size 1.9 x 1.9 x 1.25 mtrs and foundation bolts 12 nos of size 30 mm dia 920 mm long of MS bright with nuts, double washers, foundation bolts template of size 1250 x 1250 x 3 mm thick sheet, the chimney foundation bolts shall be designed and fabricated to withstand the location wind speed upto 50 km/hr complete including Instrument Lifting Arrangement, Smut arrester and each joint with Flange mounting arrangement complete all as specified and as directed. The chimney shall have the GI flat as lighting arrestor placed with suitable earthing | |||||||||
| 1.05Out Door Panel Board : Design, fabrication, Supply, install, testing & commissioning of CPRI approved feeder pillar of size 600x450x300 mm Out-door self-standing CRCA sheet enclosure IP52 steel of thickness 2.5 mm cubicle type and having busbar rating of 200 Amps, complete with two contactors, Glands, Temperature Indicator, Emergency Stop Switch, indicator lamps etc. The panel will be suitable for front operation complete electric connection. The panel board starting sequence shall be according the Incineration system and with following items. (i) Incoming 'C' Curve MCCB 4 pole 63 Amps 15 KA - 01 No. (ii) Indicating Lamp-230Volts RYB/On/Off/Trip (Incoming). (iii) 1HP DOL: 25A DP 15kA 'C' Curve MCB Amps - 02 Nos. (iV) On/Off Selector Switch ( Out going) | |||||||||
| 1.06PCC Platform and Wall : Material and labour for PCC platform for Incinerator of size 5 mtr x 5 mtr including (i) Excavation not exc 30 cm deep and getting out in soft/loose soil complete all as specified. (ii) Material and labour hard core of gauge not exc 63 mm of broken bricks aggregate spread and levelled in layers not exc 15 cm thickness watered and rammed to a true surfaces.(iii) Material and labour for plain cement concrete (1:4:8) type D2 using 40 mm graded crushed stone aggregate 75 mm as sub base flooring complete all as specified. (iv) M& L for 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 100 mm and as directed by EIC. (v) Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed by ENgr-in-charge. (vii) All Around Wall of 3 Feet height with 6" block and cement plastering on two surfaces and includes two coat white washing with lime or primer to give an even shade. | |||||||||
| 1.07Fabrication of Shed Structure with Roof:- Material and labour for fabrication of roof structure for complete incinerator of size 5.5 x 5.5 mtr with column height of 3.5 mtr having 6 nos of MS Column pipe profile 150 mm dia 3 to 4 mm wall thickness and roof structure frame for roof truss with 80x40 RHS of 2.5 mm thick of suitable lengths to withstand roof structure, including MS base plate of size 250 x 250 mm of thickness 12 mm with foundation bolts of 16 mm dia 300 mm long (four nos each for one column pipe) roof purlins and roofing including two coats of synthetic enamel paint after one coat of red oxide primer complete all as specified and as directed with meta coated corrugated sheet of 0.8 mm thick and shall be fixed with self tapping screw of suitable size complete all as specified and as directed by Engineer-in-charge. | |||||||||
| 1.08MS Stand Frame with Supply of water tank:- Material and labour for rotational moulded polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 2000 ltrs including fabrication and fixing of MS structure frame of size 1.5x1.5 mtr and upto the height of 1.95 mtr with ISMC 75 with 5 mm thickness and base structure to sustain the weight of syntex including two coats of synthetic enamel paint after one coat of red oxide primer complete all as specified and directed , Make: Sintex/Rotex/Polycon) NOTE :- After commissioning / completion of the work, inspection will carried out by third party and inspection by CPCB approved lab .The rate quoted above shall include for complete job as described in 1 to 1.08 above for complete installation, commissioning and testing and will not pay any extra cost for incinerator. No extra cost will be paid to the tenderer for getting approval / testing report from CPCB. | |||||||||
| 2.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq.mm 3½ core all as specified and as directed. | 160 | RUNNING METRE | 435 ₹69,600 | 450 ₹72,000 | 740 ₹1,18,400 | 380 ₹60,800 Lowest | 510 ₹81,600 | 900 ₹1,44,000 |
Tender Value
₹47.6 L
EMD Value
₹95,200
Closing Date
22 Oct 2025, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
PROVISION OF INCINERATOR SPIRAL IRON LADDER AT ERAS BUILDING VENETIAN BLINDS CHEMICAL EARTHING PITS FOR AF NET AND UVSS FACILITY AT CABS BANGALORE
2025_MES_729623_1
8649/E8
Open Tender
Civil Works
Item Rate
120 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY a(i) and b(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹95,200
Yes
3 Dec 2025
26 Sept 2025
29 Oct 2025
26 Sept 2025
22 Oct 2025
10 Oct 2025
26 Sept 2025 - 9 Oct 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8649Tender.pdf
Tender Documents • 1.49 MB
BOQ_820584.xls
BOQ • 2.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .