Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC 229 2 HP SHASTRI ROAD NETAJI PALLY POST RABINDRA SARANI SILIGURI 734 006 | SILIGURI | COOCH BEHAR | WEST BENGAL | 734006 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹28.0 L+₹4.3 L (18.3%)Rejected-Finance RABINDRA NAGAR P O RABINDRA SARANI SILIGURI 734 006 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734006 | L2 | Rejected-Finance Highest | |
| 3 | L3₹28.3 L+₹4.7 L (19.8%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance Highest | |
| 4 | Rejected-Technical 389 A DHOOP COMPANY ROAD PRADHAN NAGAR SILIGURI 734 003 | SILIGURI | DARJEELING | WEST BENGAL | 734003 | - | Rejected-Technical Insufficient documents found |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
8 Dec 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Superintending Engineer PWD North Bengal Electrical Circle P W D Inspection Bungalow Annex Building 1 st Floor Kutchery Road Venus More Siliguri
Construction of HDU over existing S N C U buildings at Birpara State General Hospital Alipurduar S I T C of D G and UPS
2020_WBPWD_304323_1
WBPWD/SENBEC/NIT-31(3RD CALL)/2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Birpara
Please Refer Tender Documents
4 documents required · 4 mandatory
₹38,000
10 Mar 2021
10 Nov 2020
10 Dec 2020
10 Nov 2020
8 Dec 2020
11 Nov 2020
120 days
Amount
SUB HEAD SITC OF DG SET
SITC of 3Ø Silent Type Diesel Generating Set having Prime power Rating of 125 KVA at 415V, 50Hz, 0.8 lagging Power Factor on the existing foundation comprising of Engine, alternator, AMF panel, Base frame, Fuel tank, Battery, Acoustic Enclosure and other accessories as per detail specification as given below
ENGINE
Make : Caterpiller / Cummins / MTU / Volvo / Parkins
Engine Type : 4 Stroke Diesel Engine
Rated Output : 158 BHP or Higher
Duty : PRIME
Cooling : Liquid Cooled
Cylinder : 6
Aspiration : Turbo Charged
Type of Governer : Electronic
Fuel Tank Capacity : As per manufacturer standard.
a. Fuel Consumption at 75% rated Load with Radiator or Fan : 22.5 Ltr./ Hr. or Less b.Fuel Consumption at 100% rated Load with Radiator or Fan : 30.25 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning / Shutdown, High Engine Water Temp. warning / Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator.
Exhaust Silencer : Residential Type
Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low / High Battery Voltage and Weak Battery warning
ALTERNATOR
Make : Leroy Somer / Stamford
Rating : 415 V., 3Ph. 50 Hz., 125 KVA,
Type : Brushless, self excited and self regulated through AVR
Insulation : Class H
Protection : Screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF PANEL
Cubical type floor mounted AMF panel made from 14 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 250 KVA DG set having following specification / features.
i)2 No. 250 A AC1 duty, 4pole power contactor and U/V release etc. [Make: ABB, Legrand, Schneider]
ii) 2 Nos. 250 A, 4pole, 50 KA MCCB with microprosser based LSIG protection.
iii) In Built By-Pass switch for rated capacity
iv) On -delay timer for load change over
v) On-delay timer for engine shut off
vi) Engine On-Off switch (Push button type)
viii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
ix) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
x) Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACQUISTIC ENCLOSURE
The DG set will have high quality integrated acoustic enclosure duily designed in accordance and certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i)All materials, equipments & accessories must conform to relavent IS specifications with latest ammendments.
(ii) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(iii) All materials, equipments & accessories must conform to relavent IS specifications.
(iv) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(v) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(vi) Circuit Diagram for AMF Panel must be submited from the Manufacturer / OEM.
(vii) The entire set must be warranted atleast 15 months from the date of Delivery / 12 months or 5000 Hrs running from the date of Commissioning whichever is earlier. However Engin & Alternator should be warranted of 2 years / 5000 Hrs running, whichever is earlier.
Providing cement concrete foundation for the DG set with 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size)[M20 grade ] including excavation, providing base concrete with 1:5:10 cement concrete, required centering / shuttering, finishing the exposed portion etc. as reqd. ( Item will be paid based on measurements for 1:2:4 CC, but excluding the 1 : 5: 10 leveling course of base concrete) as per direction of E-in-Charge and manufacturer recommendation.
Supplying and fixing exhaust gas piping (115MM Diameter ). welded black MS, B class pipe conforming to IS: 3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50 mm thick wiremesh and aluminium cladding etc., as per requiremement of pollution control norms and required as per direction of Engineer-in-Charge and manufacturer recomendation.
Supply and pour of H.S. Diesel oil for necessary commissioning of new DG incl. transportation cost.
Supply, Delivery including transportation of Mobil Oil
Supply & delivery PVC 200Ltr. Oil Barrel of thickness 6mm.
S & Delivery of best quality oil hand pump with 1” dia PVC flexible pipe (12’ ft. approx)
SUB HEAD LT CABLING
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable (Armoured) conforming to IS: 7098 / 1988 with its latest amendment of following size. (KEI / GLOSTER / HAVELLS)
4 Core 70 Sq. mm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish including removing the rubbish
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor / pavement / wall etc.
Laying of cable above 3½ core 50 sqmm and upto 3½ core 95 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4Core 70 Sq. mm
Finishingtheendoffollowing XLPE / PVC armouredcables by crimping method incl. supplying and fixing solderless socket (Dowels Make), tapes, anticorrosive paste & jointing materials.a) 4 core 70 sq mm.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
50mm dia
SUB-HEAD -- EARTHING
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS
For Soft Soil [ 1(a)/G-1]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With ISI-Medium GI pipe as per GS
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
4SWG [5(a)(i)/G-2]
6 SWG [5(a)(ii)/G-2]
8 SWG [5(a)(iii)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS
Supply and drawing 4x10+2x6 sq mm Copper wire make KEI / Polycab / Havel's / RR Kable / Precision through 32 mm rigid PVC conduit make Precision / Polycab and termination at both ends
Supply and fixing 4 way single door MCBDB enclosure with 1 no 32 Amp 4 pole MCB 415 VAC fixed on wall as per direction of EIC Make HAVELLS / STANDARD / L&T / ABB
SUB HEAD SITC OF UPS
SITC of 3Ph- 3Ph true Online UPS System in standalone configuration with advance DSP based technology’ Double conversion IGBT Rectifier and IGBT based inverter UPS system with inbuilt/External Isolation transformer with cabinet and SMF battery backup using 12V batteries including battery protection M.S Rack suitable dimension, well air ventilation to ensure the battery optimum life cycle, proper rating cable for interlinks cable and D.C cable up to 10 mtrs from UPS to batteries including labour charges for installation testing and commission and carrying charges with following Special Features.
Protections: input & Output over / under voltage single phasing, DC - High / under voltage, Battery charging over current, output overload / Short Circuit / Over temp. UPS auto on mains recovery protections. Input & Output over / under voltage, single phasing, DC – High / under voltage, battery charging over current output overload / short circuit / over temp. UPS auto ON mains recovery switchgear: MCB / MCCB for input battery, output & manual bypass switch operating temp. 0 to 40Deg C, IP 20enclosure,
RH max 95% forced air cooling, max sound less then 60db, communication: Rs. 232, Rs. 485, dual input Kit, monitoring software: UPS monitoring software on windows XP platform, Certification: ISO 9001:2015 ISO 14001: 2015, ISO 18001 RoHS & OHSAS 18001, CE Certification: IEC/EN 62040-1-1, IEC/EN50091-1, IEC/EN 60950 (safety) IEC/ EN 50091-2, IEC/EN 62040-2 (EMC Emission), IEC/EN 62040-3 (performance & Design) IEC/EN 61000-4 (EMC Emmunity) & IEC/EN 60146.
Battery make:- Exide Power Safe/ Amararaja Quanta Note- i. The agency must procure the materials from the manufacturer / OEM or from their authorized sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. ii. Documents that authenticates such procurement form the manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-charge and hard copy of it to be submitted during execution of work / submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules. (Three years spare & maintenance warranty after commissioning of the UPS to be provided; security deposit will be released after three years of commissioning date, DLP period 3 years, AGENCY / CONTRACTOR / OEM HAS TO ATTEND AND RECTIFY FAULT(S) WITHIN 24 HOURS OF RECEIPT OF COMPLAINT. CERTIFICATE IN THIS REGARD IS TO BE UPLOADED.)
M/S DAWN ELECTRICAL INDUSTRIES
ORIENT ENGINEERING WORKS
stage.html
html • 0.05 MB
technical_570453.pdf
PDF • 0.06 MB
techsummary_570453.pdf
PDF • 0.10 MB
finance_570453.pdf
PDF • 0.06 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_570453.pdf
PDF • 0.08 MB
AOC31.PDF
PDF • 0.20 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .