Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 59 16 RAM NAGAR ROTI GODAM KRISHNAPURI MATHURA MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical 00 JALESAR MAHAVIR GANJ 00 VILLAGE TOWN JALESAR CITY ETAH ETAH UTTAR PRADESH 207302 INDIA | ETAH | UTTAR PRADESH | 207302 | Not Admitted-Fee/PreQual/Technical Others-Not Submitted EMD and Tender Cost in official Account by RTGS/NEFT as mentioned in Bid |
Tender Value
₹50.8 L
EMD Value
₹51,000
Closing Date
17 May 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle Agra Kakraitha Road, Near Amar Ujala Press, Sikandara , Agra
Erection and Commissioning of 60 MVA Transformer for increasing capacity and construction of 220 and 33 KV Bay and other associated work at 220 KV S/S Sikandra under ETD-II Agra
2023_UPTCL_798497_2
ET_04_ETC_A_23_24
Open Tender
Electrical Works
Lump-sum
120 days
Agra
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE_A_ETC_AGRA
₹51,000
25 May 2023
9 May 2023
18 May 2023
9 May 2023
17 May 2023
9 May 2023
Supply
Supply of U bolted type Single Tension Fitting Assembly with Gun fitting ,suitable for single AAC Tarantulla Conductor including complete with Hardware fitting ,D sackle,Socket Eye,Ball Hook,Yoke Plate ,D-Clip,Tension Clamp etc. as per Technical Specification and sample.
Supply of U bolted type Single Tension Fitting Assembly with Gun fitting ,suitable for Single ACSR Zebra Conductor including complete with Hardware fitting ,D sackle,Socket Eye,Ball Hook,Yoke Plate ,D-Clip,Tension Clamp etc. as per Technical Specification and sample.
Supply of U bolted type Single Tension Fitting Assembly with Gun fitting ,suitable for Single ACSR panther Conductor including complete with Hardware fitting ,D sackle,Socket Eye,Ball Hook,Yoke Plate ,D-Clip,Tension Clamp etc. as per Technical Specification and sample.
Supply of U bolted type Single Tension Fitting Assembly with Gun fitting ,suitable for twin ACSR Moose Conductor and including complete with Hardware fitting ,D sackle,Socket Eye,Ball Hook,Yoke Plate ,D-Clip,Tension Clamp etc. as per Technical Specification and sample.
Supply of U bolted type Single suspension Fitting Assembly with Gun fitting ,suitable for ACSR twin moose Conductor including complete with Hardware fitting ,D sackle,Socket Eye,Ball Hook,Yoke Plate ,D-Clip,Tension Clamp etc. as per Technical Specification and sample.
Supply of rigid spacers suitable for 220KV Bus bar Twin ACSR Moose Conductor with 250mm spacing and duly made of LM-6 Aluminium Alloy complete with 12mm dia HDG bolts, Nuts, Spring, and plain washer as per technical specification and sample.
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR Tarantulla to Tarantulla conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring & plain Washer as per technical specification and sample.
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for AAC tarantulla to ACSR Panther conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample.
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for AAC tarantulla to Zebra conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample.
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for AAC tarantulla to ACSR Moose conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR panther to ACSR panther conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR panther to ACSR Moose conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample.
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR panther to ACSR Zebra conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample.
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR Zebra to ACSR Moose conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring & plain Washer as per technical specification and sample.
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR Zebra to ACSR Zebra conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample.
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR moose to ACSR moose conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample.
Supply of cooper flexible bond of 15X450 mm size with cooper lug fitted at both end having hole of 15mm dia in one lug and 12mm dia in other lug as per specification and sample.
Supply of Run Through clamp for Bus post insulator suitable for twin Zebra conductor made of All Alloy LM-6 complete with nut, bolt & wahser as per sample.
Supply of Run Through clamp for Bus post insulator suitable for twin Moose conductor made of All Alloy LM-6 complete with nut, bolt & wahser as per sample.
Supply of performated cable tray of width 150 mm as per sample.
Supply of cable glands for 2core, 4 core,6 core ,12 core cable with double compression type as per sample ( 1set = 50 gland of each type i.e total 200)
Supply of 22 Kg fire extinguisher carbon dioxide type as per IS specification number 2878/1986 and as per technical specification
Supply of 11 Kg fire extinguisher carbon dioxide type as per IS specification number 2878/1986 and as per technical specification
Supply of 4.5 Kg fire extinguisher carbon dioxide type as per IS specification number 2878/1986 and as per technical specification.
Supply of 50 Kg portable AFF mechnical foam type fire extinguisher complete with initial charge hose pipe and all other accessories and fitting as per IS1024 Trolly /wheel mounted
Supply of Pin type bus post insulator having rating 22KV complte with nut ,bolt and washer
Supply of 120KN procelin disk insulator
Supply of 70Kn porcelin disk insulator
Earthmat extention and strenghtening work
Laying of earthmat in the exitended switchyard of the substation alomg with connecting the newly laid earthmat with existing earthmat as per details below:-
Fabrication of 3 mtr long electrode with 40mm dia Ms Round bar having 150mm long conical shape by due cutting straighting etc. and then piercing it vertically inside the ground with top 700mm below the ground level including shifting of MS round bar from the storage place at substation to switcyard
Laying of 40mm Dia MS round bar, 700mm below the ground level by due cutting straighting welding,painting excavation of trenches,backfilling of trench after laying of earthmat include shifting of MS round bar from storage place to switchyard
Making of 150mm long lap joint of above laid 40mm dia round bar to conect with existing earth mat of substation by due cutting straighting welding etc.
Making of 150 mm long lap jpint of above laid 40mm dia round bar by due cutting straighting welding etc.
Making of cross joint of above laid 40mm dia MS round bar 700mm below the ground level by due welding at all four corners including provifing and welding od suitable size 4 No of MS angle pieces on opposite corner of cross joint
Making of MS joint of above laid 40mm dia MS round bar with top of already vertically peirced MS electrode 700mm below ground level by due welding
Boring with 150 mm dia casing pipe to a probable depth of 21.0 meter long from ground level with skilled and unskilled labour including all T&P, boring apparatus and supervision charges etc. required for proper completion of work.Inserting 40x6 mm G.I. flat in 50 mm dia B-class (jindal) ISI mark 6.0 meter long 3 pipe placed horizontally on ground and bolting the G.I. flat with 150 mm long 75x6 mm copper plate conical piece on and then bolting the G.I. flat with G.I. pipe in such a way that copper flat remains in contact with the pipe. Lowering of 6.0 meter long G.I. pipe with conical copper Plate connected and at bottom along with G.I. flat inside the pipe in boring of 150 mm G.I. pipe pieces by G.I. sockets along with 40x6 mm G.I. flat running inside the pipe by making 150 cm lap joints 75 mm above ground level. Taking out 40x6 mm G.I. flat from the upper end of pipe by making a cut of 45 mm wide up to a depth of 50 mm in upper portion of G.I pipe and providing 1 no. cap type G.I. socket on upper threaded portion of pipe for water pouring in the pipe at regular intervals filling the space. All material to be provided by the contractorFabrication of M.S. electrodes out of 32 mm dia M.S. round 3.0 meter long having 150 mm long conical shape.Excavation of pit of size 2.00 M x 2.00 M x 1.50 M. driven of M.S. electrodes of 40 mm dia 3.0 Mtr. long in the earth on three corner of the pit equal distance of 2.0 Mtr. long keeping the top of electrode 50 cm above the pit ground level, welding of 40 mm M.S. round pieces of 3 Mtr. long on all three sides of electrodes and 15 cm below of top of electrode by 8 Nos. U-type clamp of 50x6 mm M.S. flat connecting a piece of 3 Mtr. long 40x6 mm G.I flat on opposite side of square welding of 40x6mm G.I flat on opposite M.S. electrode driven in ground and connecting the 40x6 mm G.I. flat. (Only M.S. Round & M.S. Flat shall be supplied by the department free of latest cost.)(G.I. Pipe, G.I. Flat, Copper Plate, Coal, Salt, Nut & Bolt shall be arrange by the contractor )
Erection work
220 & 33 KV Bay and bus bar erection work
Erection and Fabrication (if needed) of Lattice type main gantry and auxillary structure their respective beams as per drawing /BOM is to be carraied out by contractor .All the duly stacked members of structure are to be shifted from store to work site ,tightining of nut ,bolts washer,fastening of beams applying standard practise .Beams are to be fastened on the proper alignment with exting coloum including latest cost of all labour ,T&P etc
Laying and stringing of 220 KV 3 phase main bus A,Main bus B and transfer bus bar including hoisting of disc insulator, suspension and tension fitting etc. along with shifting of the conductor/material place at that substation to the erection site
Stringing of 220 KV 3 phase main bus bar A of single AAC taruntulla conductor(1 JOB for each phase of bus bar per section)
Stringing of 220 KV 3 phase main bus bar B of single ACSR Zebra conductor(1 JOB for each phase of bus bar per section)
Stringing of 220 Kv 3 phase tranfer bus bar of single ACSR Zebra conductor (1 job for each phase bus bar per section)
Stringing of 220 KV 3 phase Jack bus bar of single ACSR Zebra conductor (1 job for each phase bus bar per section)
Laying and stringing of 33 KV 3 phase bus bar including hoisting of disc insulator, suspension and tension fitting etc. along with shifting of the conductor/material place at that substation to the erection site
Stringing of 33 KV 3 phase Jack bus bar of double ACSR moose conductor(1 JOB for each phase of bus bar per section)
Stringing of 33 KV 3 phase Jack bus bar of single ACSR panther conductor(1 JOB for each phase of bus bar per section)
Erection of equipment in proper alignment with complete adjustment in switchyard on the erected structure as per manufacture drawing or as per direction of supervising engineer after levelling including shifting the equipment from store to working site etc, alonf with their junction box, control cubical and accessories including the latest cost of labour T&P cranes for proper completion of work
220 Kv transformer Control Panel
220Kv transformer relay Panel
220 Kv transformer rtcc panel
245 Kv SF6 type circuit breaker with structure and modification if necessary
220 KV CT with junction box
220 KV PT with junction box
220 KV Line isolator with PI ,earth switch and adjustment
220 KV Bus isolator with PI ,earth switch and adjustment
220 KV Tendom isolator with PI ,earth switch and adjustment
220 KV Post insulator on ALP structure
198 KV Lighting Aresstor with surge counter
33 KV VCB with structure and modification if necessary
33 KV CT with junction box
33 KV PT with junction box
33 KV Line isolator with PI ,earth switch and adjustment
33 KV Bus isolator with PI ,earth switch and adjustment
33 KV Post insulator on ALP structure
33 KV Lighting Aresstor with surge counter
Dismentelling of Fire hut/store and again reerection of Fire hut/store after repairing to other loacation as per instruction of enhineer
Opening of trench cover ,Laying and dressing of following size control cable on the cable racks in the trenches from crontrol and relay panel to various equipments for AC/DC connection of CT,PT,CB, isolator,junction box incude shifing of cables drums from store to erection site &shifting back the balanced material to store again placing back the opened trench cover including latest cost of labour,,T&P,etc. to complete the works
2C*2.5 sq mm
4C *2.5 sq mm
6C*2.5 sq mm
10C*2.5 sq mm
Termination of various sizes above laid control cable as per schedule and connection diagram ,extending DC supply from DCDB and AC supply from ACDB ,Contro & relay panel,Equipment,CT,PT, including Drilling of holes wherever required ,fixing of performated cable tray ,fixing different sizes of cable gland ,ferrul,&crimping type ,lugs,including latest cost of required skilled material ,Technician,T&P for proper completion of work.
Earthing of main and auxillary structure equipment,trench and panels with the help of specified size MS flat along with cutting ,bendind and straigtining of MS flat to give it proper shape Two coat if Enamel based paint of green colour above red oxide primer layer at joint ,riser strips in all sides of surface as per drawing of earthing and standard practise incuding latest cost of consumable material,T&P ,lobour Etc.
Earthing with 75*12mm MS Flat
Earthing with 50*6mm MS Flat
Earthing with 25*6mm MS Flat
Jumpering of equipment of 220/33 KV 60 MVA transformer and associated 220 Kv bay and 33Kv bay with the help of ACSR Zebra or panther conductor to connect main bus bar and tranfer bus bar with equipment and eqipment to equipment with help of suitable clamp /connector including ,cutting ,bending,shaping,etc,of the conductor as per site requirment
Making of shielding Mesh for 220 KV LA and 33 KV LA by fabrication of 3 meter long electrode with 40 mm dia MS round bar having 150mm long conical shape and then its piercing vertically in the ground with top 700mm below ground level jointing the electrode with 75 *12mm size MS flat by welding for making mesh ,connecting the shielding mesh with main earth mat at 2 places anf finnaly painting the shielding mesh /earthing strip with anti- corrosive red oxide primer and 2 coats of green paiht with digging of earth /trench and its back filling
Providing ,fixing and installation of Sign board of 3ft*2ftduly made of 2mm thick GI plate painted with red oxide promer with 2 coatinf and then yellow bright and shiny yellow paint and panted with black letter as direction of site engineer.board shall be provided with back support frame of size 35mm*35mm*5mm with provision of 2 leg for grouting duly painyed with black enamel paint complete with all repect to be grouted with casting of C.C founadation
Work of loading, safe carriage and unlaoding of any equipment, structure or any other material from any substation of UPPTCL to JE store of 220KV S/S,Sikandra,Agra. Every to and from carriage from 220KV S/S,Sikandra,Agra will be considered as one job.
220/33 KV 60 MVA Transformer erection and commissioning work
Complete erection of 60 MVA make 220/33 kv capacity transformer by erection of radiators canservator tanks. All bushing their turrets connecting oil pipe lines, cooling fans (including cable connections on T/F body), motor drive mechanism of tap changer, rtcc panel, oil pumps and associated oil pipe line etc to completion the job satisfactorily including attending the oil leakage, if any and all other associated works for satisfactory completion of all other associated works for satisfactory completion of work . no T&P shall be provided by the deparment
Shifting of main tank of 60 MVA T/F 220/33 KV make at 220 KV S/S Sikandra Agra from unloading point in switchyard to newly constructed plinth of 60 MVA T/F approx 20 mtr distance including all T&P and all other works required to complete the job satisfactory as per technical specification enclosed.
Additional shifting of 5 mtr or part there of.
Shifting of 50 KL oil tank from any substation of UPPTCL to 220 KV S/S Sikandra Agra
Shifting of 6 KL oil tank from any substation of UPPTCL to 220 KV S/S Sikandra Agra
Draining out 32 KL oil tank 209 Ltr oil drums to 50 KL tankstanks including shifting of drum within the S/S premises.
Centrifuging of complete transformer oil approx 32 KL in 50 KL oil tank by connecting centrifuging pipes etc.
Creating vacumm in 60 MVA make Transformer up to level of 760 mm of Hg inside tank
Filling of 32 KL T/F oil from 50 KL tank. To main tank conservator & radiator.
Centrifuging of complete transformer oil in transformer main tank or oil tanker by conncecting cennecting centrifuging machine arranged by contractor and taking the B.D.V values of the oil periodically till the required values is achieved as per direction of supervising engineer.
Control cable laying from marshalling box of 60 MVA Transformer to control panel, relay panel and marshalling box to RTCC panel of different size cables, all cable ferrule, cable gland of various size is to be provided by the contractor as per required complete the job satisfactorily.
Delta earthing constsisting of fabrication of 3 Nos. 3 mtr. Long electrode (40 mm dia MS Bar) its placing 700 mm below ground and connection of all 3 electrode with 75X10mm MS Flat and connection the same with main earthmat at two places. MS Bar flat and angle will be provided by the department .
Earthing of 60 MVA Transformer body , neutral of T/F motor drive mechanism , marshalling box. RTCC panel with 75X10mm. 50X6mm, MS flat as per required and its joining with already laid earth mat at 2 places with necessary modification in exsisting support structure for earthing. Painting of green colour in two coats and all other associated work complete the work satisfactorily . MS Flat and angle will be provided by the department.
Emulsifier supply, erection & commissioning work
Supply along with installation , testing & commissioning of MS pipe 'B' class as per IS specification (IS code 1239,IS code 3589) for fire hydrant system complete with elbow,tee ,socet, reducer etc. with anti- corrosive paint teatment with detail given below (JINDAL,APPOLO,TATA).
Spray Nozzle SD 17-5
QB Detector
Pressure guage as per IS Specification 3624 Accuracy 5%
Supply &instalation testing commisioning of quick opening flood deluge valve with sprinkler alert alram of HD/Mather/Plate of 100 NB as per maximaum working pressure of 10Kg/cm2
supply and installation testig of 'Y" type strainer (Karter/sir/agra/kalpana) make of dia 100 NB working pressure 10KG/cm2
Supply along with installation , testing & commissioning of gate valve (Sludge Valve/Butterfly Valve) (Kartar/Sir/Zoloto make) as per IS Specification (is Code:14846) of
Provide and fixing one coat of 4mm pypwrap/coatax antirust pipe protection including primer and lap of 25mm on external buried pipe including surface preparation complete in all respects.
Supply & installation of flange as per IS-1538 of different size as per drawing work include proper Butt welding with pipe & proper packing and coupling with Nut bolt ( 1 set = 2 no flange).
Fabrication and erection of MS angle Plyon support for holding the air and water ring including latest cost of all material,cutting ,welsing and clamping with u- Bolt ans all other associated work
Casting of pylon founadation in 1:2:4 concrete mixture sizw .5*.5*1 mtr with 16*450 4 Nos and 400*400*8mm plate including all material as cement ,sand,20mm stone
Supply & installation testing commissing of fire hose boxes suitable for 15 mtr long,63 mm dia reinforced rubber lined fire hose pipe (as per IS-636) with gun metal branch pipe nozzel ( As per IS -903) and gunmetal landing valve of 63 mm dia (As per IS code 5290). (1Set =15 meter long RRL hose pipe with gunmetal nozzel+15 meter long gun metal male and female coupling pipe for quick assembling with existing branch pipe+63 mm gun metal hydrant landing valve + box) .
Complete Integretetion , reinstalling, and recommissioning of master control panel in the pump house room with newly installed mulsifier system at 220/33 Kv 60 MVa transformer this include provision of repairing/replacement of battery charger,replacement of malfunction relay alarm system, auto- manual working of pump including all siklled labour ,material, commissioning latest cost.Then complete overhauling of 75KW electric motor driven main fira pump with end suction type capacity 210 Mtric cube per hour which inclide installation of water gland and seats and 2 coats of paint. after that complete overhauling of 11KW electric motor driven main jockey pump with end suction type capacity 11 Mtric cube per hour which inclide installation of water gland and seats and 2 coats of paint
Miscellaneous work
Supply and fixing of outdoor high beam flood light with power 100 Watt (LED) as light Sourse and versitile pressure Die-cast aluminium body with poly carbonate fitting having potted type power driver suitable for 220 AC input supply of IS marked havels/philips/Syska with warrenty of 2 year
Supply and fixing of junction box of size 280X22X150mm made of 16 SWG sheet duly painted on cloumn by fixing GI flat and its earthing with 12 SWG GI wire and fixing 1 no of 6 amp MCB for connection to the LED with 3 phase backalite terminal block and cooper neutral link complete in all respect with all material,labour and T&P
laying and termination of 2C/4C/6C 2.5 sq mm size of cable 500mm below the ground including excavation of trench of appropriate size ,laying cable termination proper dressing and all assocated work to complete the job as per specification.
Supply and fixing of outdoor 3 phase Lightining AC Subdistribution box of size 450x450x250mm duly painted with one coat of red oxie primer and two coat of synthetic enamel paint .4 No almunium insulated bus bar for AC distributional and 1 no. of 100AMP TPN SFU with SS of haevells /L&T make/C&S.It should have 4 no. of bakalite fuse with fuse base of 100 Amp and hole should be provided for 4 no. cables of 50/95 sq mm with cable glands(fire proof) of dowell make then termination on both side cables .cubical box made of 16 SWG MS sheet sheet in double shutter with indoor locking arrangements complete with wiring of proper size and phase indicatora nd earthing terminal
Supply and fixing of 2 tonn split air conditioning unit with stabalizer in the control room make HITACHI/O-general/Mitishubushi complete with all associated accessories having 2 year comprehensive and 5 year compressor warrenty due to not availibilty of air conditining in new extended control room
Dismentalling work of 132 and 33 KV Capacitor bank
Dismentalling of 132Kv old and damaged capacitor bank which include complete dismentalling of Main Structure beam and column with Isolators ,breaker,capacitor cell, Series reactor,Neutral Current transformer and associated auxillary structure from the base .Then stacking and arranging of dismentalled 132 KV old and damaged structure from site to store location as per instruction of enginner with the help of hydra and manaul labour
Dismentalling of 33Kv capacitor bank which include complete dismentalling of Main Structure beam and column with Isolators ,breaker,capacitor cell, Series reactor,Neutral Current transformer and associated auxillary structure from the base .Then stacking and arranging of dismentalled 132 KV old and damaged structure from site to store location as per instruction of enginner with the help of hydra and manaul labour
Dismentalling and decommissioning of 132 Kv and 33 KV capacitor bank Protection panel which include tracing the cables from control room panel to switchyard ,then removing it from trench after making proper cable termination schedule by skilled technician such that during the dismentalling work no other cable or protection system of control room or switchyard gets damaged.Work shall be complted properly and very delicately and then de commissioned panel will be transferred to JE strore as per instruction of engineer
Re-erection work of 33 KV capacitor bank
Work of re-erection of dismentelled 33Kv capacitor bank and lighting pole include following job
Carraige of main gantry and column structure of 33 Kv capacitor bank from dismentallted/store to erection site with the help of Hydra and then erection of column and gantry completely on the plinth .
Hosting and stringing of 3 phase main bus bar single ACSR panther conductor with associated hardware accessories which include disc,gun fitting etc to complete the job sataisfactorily
Erection of breaker,isolator,capaciotor cell with auxillary structure,series reactor,NCT,main CT,PT, capacitor bank Protection and control Panel from old contol room o new control room in proper alignment with complete adjustment in switchyard on the erected structure as per manufacture drawing or as per direction of supervising engineer after levelling including shifting the equipment from store to working site etc, alonf with their junction box, control cubical and accessories including the latest cost of labour T&P cranes for proper completion of work
Opening of trench cover ,Laying and dressing of control cable on the cable racks in the trenches from crontrol and relay panel to various equipments for AC/DC connection of CT,PT,CB, isolator,junction box incude shifing of cables drums from store to erection site &shifting back the balanced material to store again placing back the opened trench cover including latest cost of labour,,T&P,etc. to complete the works
Termination of various sizes above laid control cable as per schedule and connection diagram ,extending DC supply from DCDB and AC supply from ACDB ,Contro & relay panel,Equipment,CT,PT, including Drilling of holes wherever required ,fixing of performated cable tray ,fixing different sizes of cable gland ,ferrul,&crimping type ,lugs,including latest cost of required skilled material ,Technician,T&P for proper completion of work.
Earthing of main and auxillary structure equipment,trench and panels with the help of specified size MS flat along with cutting ,bendind and straigtining of MS flat to give it proper shape Two coat if Enamel based paint of green colour above red oxide primer layer at joint ,riser strips in all sides of surface as per drawing of earthing and standard practise incuding latest cost of consumable material,T&P ,lobour Etc.
Re-erction after dismentalling of Street lighting pole with complete accessories which include main pole body ,lightining fixture ,cable and termination box.The work include erection of street ligting pole after digging pit and casting M25 RCC mix founadation of pole and then laying the cable below the ground in he deph of 300mm and proper temiantion the cable at pole and nearby power supply .after that hosting the tlighting box and stree light such that proper alignment and tighting is ensure.Each pole dismentalling and re erection will be considered as one job.
MEERA GYAN ENTERPRISES
SATKAR TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .