Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC HAMIRPUR ROAD UNA HIMACHAL PRADESH 177203 | UNA | HIMACHAL PRADESH | 177203 | L1 | Accepted-AOC Due to lower rates | |
| 2 | L2₹13.4 L+₹36,324.46 (2.78%)Rejected-Finance | L2 | Rejected-Finance Due to higher rates | |
| 3 | Not Admitted-Fee/PreQual/Technical 11 VILLAGE BHADAS TESHIL FEROZEPUR JHIRKA DISTRICT NUH 122108 | BHADAS | NUH | HARYANA | 122108 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹13.1 L
EMD Value
₹26,120
Closing Date
20 Jan 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer, Provincial Division, PWD BNR Br., Nuh
Construction of Rain Water Harvesting Well Rain Water Harvesting System at Residential Houses for Judicial Officers in Mini Secretariat Complex at Nuh in Nuh Distt.
2021_HRY_202106_1
PWD/Nuh/Harvesting
Open Tender
Civil Works
Works
60 days
Nuh
As per bid document
3 documents required · 3 mandatory
₹1,000
Yes
₹26,120
Yes
Nuh
25 Apr 2022
30 Dec 2021
21 Jan 2022
30 Dec 2021
20 Jan 2022
30 Dec 2021
6 Jan 2022
120 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a ead of 50 m. (HSR 4.14.1)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and Shelves (Cast in situ). (HSR 6.30.4)
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note:- Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). M-10 grade plain cement concrete (cement content considered @ 220 kg/cum). (HSR 6.22.2.3)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: 1 : 1. 5: 3 (1 cement: 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size) (HSR 6.14.1)
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1 :3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½ :3 (1 Cement: 1½ coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.39.1)
Providing and fixing up to floor four level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1 :3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) (HSR 6.38.1)
Brick work with common burnt clay non modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement: 6 coarse sand). (HSR 7.21.2)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes.150 mm diameter. (HSR 9.57.3)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion. (HSR 9.58.5.3) 150 mm bend
Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand) : (HSR 10.37.1) 25mm thick
12 mm cement plaster of mix : 1 :6 (1 cement: 6 fine sand). (HSR 11.5.3)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (HSR 12.50.1)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Cold twisted bars (HSR 6.33.3)
Providing and placing in horizontal layers filtering media screened washed and cleaned as described below. (HSR 20.52)
Top Layer:- Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4 mm with uniformity coefficient 2.0 to 3.0) from Ghaggar or other approved source. (HSR 20.52.1)
Second Layer:- Coursed sand screened, cleaned and washed and graded from 3 mm to 6 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.2)
Bottom Layer:- Broken stone, screened, washed and graded from 50 mm to cum 75 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.1)
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benching 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 21.84) Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping. (HSR 21.84.1)
Extra for every 0.30 metre depth of Inspection chamber. 450 mm x 450 mm inside. (HSR 21.85.1)
Providing salt glazed stone ware pipes grade 'A' in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 600mm i/d (HSR 21.94.10)
Providing and Lowering 225 mm outer dia UPVC pipe threaded (10kg/CM2) duly ISI marked IS Code 12818:1992 complete in all respect as per directions of Engineer-in-charge. (HSR 20.91)
Providing & fixing steel bar embedded plastic steps of size 263mm x 143 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS : 1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1 :2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge. (HSR 21.28)
Boring with 100 mm diameter casing pipe for hand pump / tube well, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested. Beyond 12 m and up to 18 m depth. (HSR 33.1.3)
MS Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .