| 3 | L3₹33.0 L+₹4.1 L (14.3%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹36.6 L+₹7.7 L (26.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹37.2 L+₹8.3 L (28.8%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹83,540
Closing Date
15 Dec 2020, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
SHIFTING OF POLES WITH TRANSFORMER OF CHILDREN SCHOOL AT KIRAN LINES, OPPOSITE ZONAL RECRUITING OFFICER JALANDHAR CANTT AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2020_MES_387448_1
GE/JULL/ET-50/2020-21
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹83,540
Yes
4 Jan 2021
9 Nov 2020
17 Dec 2020
9 Nov 2020
15 Dec 2020
28 Nov 2020
Amount
Excavation in post holes (or similar holes) each n. exc. 0.5 cum in soft/ loose soil, getting out, returning, filling in, watering and ramming earth or broken rubble mixed with earth around in layers n. exc. 25cm and removing surplus soil to a distance n. exc. 50m and making good the surfaces complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in foundation of stay/ coping of poles including necessary form work and fair finish to exposed surface without using extra cement complete all as specified and directed.
Material and labour mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets, sag rods (for securing chain link fencing etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply and fixing MS chain link fencing 10 guage thick galvanised steel wire and 50mm x 50mm size mesh fixed to steel fencing post by nut & bolts etc including provision of binding wire complete all as specified and directed
Material and labour for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. using steel conforming to Fe-410 Gde-E-250 complete including drilled for fixing of steel sheeting or other covering; doors, door frame chowkhats etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including necessary cutting drilling and welding etc complete all as specified and directed.
Supply and fixing mild steel screw bolts purpose made with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut approved by Engineer-in-Charge complete all as specified
Material and labour for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Excavation in trenches in soft/ loose soil, not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundations etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 sqm on plan and getting out complete all as specified and directed.
All as per Srl item No. 8.00 here-in-before but depth exc 1.5m and n.exc 3m
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25 cm thick each layer complete all as specified and directed.
Material and labour for brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) complete all as specified and directed.
Material and labour brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 metre mean radius and built in cement mortar (1:6) complete all as specified and directed.
Material and labour for rendering 15mm thick cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for hard core of broken stone or boulder of gauge n. exc. 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and well rammed to a true surface complete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of electric pole, etc, including necessary form work and fair finish to exposed surface without using extra cement complete all as specified and directed.
Material and labour for 100mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate), as in sub floors, sub base, hard standing, concrete surfaces finished fair & even to receive topping floor finish/layer complete all as specified and directed.
Material and labour for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate), as in sub floors, sub base, hard standing, concrete surfaces finished fair & even to receive topping floor finish/layer complete all as specified and directed.
Material and labour for 60mm thick machine pressed precast concrete coloured inter-locking paver blocks any shape and size conforming to IS 15658-2006, M-35 grade, with grey cement and pigment, laid in floor/ path/ hardstandings in any pattern as approved, laid over and including 30mm thick sand cushion and interstices filled with sand using plate vibrator complete all as specified and directed. Note : The sample shall be got approved from the GE before buld procurement and lots shall be got tested independently by the GE
Removing excavated material (soils) to a distance n. exc. 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Supply and fixing in replacement aluminium conductor steel reinforced for overhead lines on poles including aluminium binding wire 14 SWG, jumpers, line tapes etc including taking out unserviceable conductor complete all as specified and directed. Note: For payment purpose weight of ACSR conductor only shall be considered.
Supply and fixing pin type insulator 150mm height, 150mm dia for 11000 volts grade porcelain vitreous white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts complete all as specified
Supply and fixing cross arms, bracings, brazing stiffness, supports clamps and back plated fabricated from structural steel section including nuts, bolts and washers, welding, bending, cold or hot drilling holes of any shape and size as directed including two coat of aluminium paint (under and finishing coat ) over a coat of red oxide or primer complete
Supply and fixing in replacement lightening arrester expulsion type complete all fittings, transmission class, discharge capacity 65 Kilo amp rupturing capacity 65 Kilo Amps porcelain conforming to IS 3070 Pt-I suitable for 11 KV, HT over head line complete including nuts, bolts, clamps, bracket etc and connecting with GI earth wire, discharge capacity 65 Kilo Amp complete all as specified and directed.
Supplying, erecting and fixing pre-stressed concrete pole 11 metre long, 152 x 152mm at top and 152 x 260mm at bottom, class 9, complete all as specified and directed including painting of poles with two coats of synthetic enamel paint over a coat of primer, black & white strips upto 1.5mtr height from top of PCC coping and numbering of poles fixed in repairs of old broken pole complete all as specified and directed. (PCC and earth work shall be measured & paid for separately)
Supplying, erecting and fixing pre-stressed concrete pole 9.0 metre long having x-sectional area 102 x 172mm at top and 102 x 279mm at bottom, class 10, complete all as specified and directed including painting of poles with two coats of synthetic enamel paint over a coat of primer, black & white strips upto 1.5mtr height from top of PCC coping and numbering of poles complete all as specified and directed. (PCC and earth work shall be measured & paid for separately)
Supply and fixing danger notice plate for HT 11 KV of size 25cm x 20cm x 1.6mm thick mild steel sheet vitreous enameled white, with letters figures of conventional skull and bones and written with "DANGER" in single red colour and fixed with MS clamps made out of MS flat 25mm x 3mm, including nuts & bolts including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed Note : Instruction are to be written in three languages viz-Punjabi, English & Hindi
Supply and fixing switch air break gang operated switch outdoor type HT 11 KV triple poles of rating 200 Amps with fixed contacts of phosphorus bronze and moving contacts of copper with mechanically operating system from ground level vertical mounted complete with HT insulators on mild steel frame and operating rod made out of 25mm GI pipe medium grade worked from ground level with handle and locking arrangements with 12 insulators of 11 KV with drop out fuses including two coats of aluminium paint on steel structure complete including submission of test certificate from manufacturer all as specified and directed. Note: Clamps/ cross arms shall be measured and paid for separately.
Supply, fixing and testing after jointing cable end jointing kit for 11 KV grade cable for outdoor type termination cold shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminium cable for size 300 sqmm 3 core complete all as specified and directed.
Supply, fixing and testing after jointing Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm complete all as specified and directed.
Supplying, laying, jointing and testing LT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts grade earthed system of size 300 sqmm 3 core confirming to IS laid in trenches, in floor, in juct, through pipes or along the pole complete all as specified and directed.
Supplying, laying, jointing and testing and commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3½ core complete all as specified and directed.
All as per Srl item No. 31.00 here-in-before but size 6 Sqmm 2 Core
All as per Srl item No. 31.00 here-in-before but size 10 Sqmm 2 Core
All as per Srl item No. 31.00 here-in-before but size 185 Sqmm 3½ Core
All as per Srl item No. 31.00 here-in-before but size 120 Sqmm 3½ Core
Material and labour for taking out carefully and re-laying of HT cable 300 Sqmm 3 Core complete all as specified and directed. Note : Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe & protection clamps shall be measured and paid for separately.
Supply and fixing 100mm bore galvanised pipe light grade fixed along poles/ to walls/ laid under floor complete with and including fittings and clamps as required complete all as specified and directed.
Supply and fixing 80mm bore galvanised pipe light grade with all fitting laid in trenches/ on poles/ road crossing complete all as specified and directed.
Supply and fixing 50mm bore galvanised pipe light grade with all fitting laid in trenches/ on poles/ road crossing complete all as specified and directed.
Material & labour for sand cushioning with 8cm thick layer before laying of cable and 15cm thick layer after laying of cable in trenches complete all as specified and directed.
Supply & laying in replacement un-reinforced pre-cast concrete cable cover, Class HV, type-I, flat, size 300mm x 180mm x 40mm laid flat in trenches over the cable length, adjacent/ abutting each other complete all as specified and directed
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
Laying of cable cover/ bricks retrieved from shifting of cable from trench complete all as specified and directed.
Supply & fixing earthing complete for transformer/ VCB panels/ LT panels with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of the plate at a depth not less than 1.50 metre below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 50mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 Nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified and directed. Note: If result is not achieved satisfactory, contractor will have to do re-earthing at his own cost. Nothing shall be paid extra on this account
Material and labour for in replacement for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15mm dia GI pipe 'light grade', watering pipe 20mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed.
Supply & fixing earthing complete for LT poles with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of the plate at a depth not less than 1.50 metre below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 20mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 Nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified and directed. Note: If result is not achieved satisfactory, contractor will have to do re-earthing at his own cost. Nothing shall be paid extra on this account
Material and labour chemical earthing complete with using copper earth plate electrode 900 x 600 x 5mm thick and 50 x 6mm copper strip as earthing lead, buried directly in ground (earth pit not less than 3.90 metres deep below ground level) with top edge of the plate not less than 3 metres below normal ground level, connected by means of bolts, nuts, check nuts, and washers of copper/ brass protected by GI pipe medium grade of 80mm dia upto test point and GI watering pipe medium grade 20mm dia with funnel and wire mesh, PCC (1:2:4) pit, PCC type B-1 using 20mm thick, CI cover with CI frame with locking arrangement, making good the disturbed surface to match the existing surface upto 2 sqm around the earth pit complete with excavation and earth work etc in any type of soil/ rock and providing ground enhancing material compound all around the earth plate upto 15cm and disposal of surplus soil to a distance not exceeding 50 mtr and as shown in electrical plate No 3 of SSR part-I (2009) and including testing on completion complete all as specified and directed. Make: OBO/ JMB/ JMV/ Power Track/ Akaaltech/ Tirupati. Note: (i) Copper strip of 50 x 6mm and GI pipe of 80mm dia, maximum upto 7.5m length and testing point terminal block shall be deemed to be included in unit rate quoted by the tenderer. (ii) The earth resistance will be less tahn 0.5 ohms. If result is not achieved satisfactory, contractor will have to do re-earthing at separate location/ site given by the Engineer-in-Charge without any extra cost to the deptt. Nothing shall be paid extra on this account. (iii) Contractor shall submit the purchase vouchers of all earthing material from the manufacturer.
Supply and fixing 25mm x 3mm aluminium strip as earth continuity conductor including fixing from test point to equipment complete all as specified and directed.
Material and labour for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm thick with arrangement by making of holes suitable with and including nuts & bolts and washers of 8mm dia for fixing GI strip & PCC testing point size 30 x 30 x 30cm for earth pit complete all as specified and directed
Material and labour anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed
N&L for fixing cable route indicators made of PCC (1:3:4) duly engraved "MES HT JOINT/ HT CABLE" coloured with two coats of synthetic paint in brown of size 150 x 150 x 900mm fixed 300mm below ground level complete all as specified and directed
Supplying, laying, jointing and testing only underground XLPE insulated, armoured heavy duty electric cable insulated and PVC sheathed LT 1100 volt grade (heavy duty) with standard aluminum conductor of size 300 Sqmm 3½ core laid in trenches, in floor, in duct, through pipes or along the pole including taking out unservficeable cable complete all as specified and directed.
Supply, installing, testing and commissioning feeder pillar, outdoor cubicle type weather and vermin proof totally enclosed made out of 3mm thick CRCA sheet machine pressed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement including inner independent enclosures for all switches/ MCCBs/ metering equipments with hinged (bottle type) shutters, bottom gland plate with sufficient numbers of circular cable entry holes with cable glands of suitable size of cable & with suitable cable glands as per number of outgoings, prewired complete duly powder coated with 7 tank process with base frame made of angle iron 00 mm x 40 mm x 5 mm, legs 100 cm long having openable apron on all three sides of panel 30 cm wide and grouted 45 cm in PCC (1:3:6) type C-1 including brick masonary platform 45cm above ground level all as specified and directedby Engr-in.charge, comprising with following complete:- (i) Bus bar suitable for 3 phase, 415 volts, 50 Hz, 4 wire system of rating 650 Amps made out copper strip of suitable size with coloured heat shrinkable sleaves in four colours (Red, yellow, blue and black) fixed on resin cast insulators including galvanised nuts, bolts and washers etc fitted with and including the following :-
(ii) INCOMING : - (a) MCCB 400 Amp, 415 V, 36 KA, 4 pole TM ICS=ICU=100% -01 No. (b) Voltmeter 0-500V-01 No (c) Ammeter 0-400A-01 No (iii) OUTGOING:- (a) MCCB 250 Amp, 415 V, 25 KA, 4 pole TM ICS=ICU=100% -02 Nos. (b) Indicator with LED lamps for RYB , 3 Phase with MCBs set of three -03 sets
Supply, installing, testing and commissioning in-replacement feeder pillar, outdoor cubicle type weather and vermin proof totally enclosed made out of 3mm thick CRCA sheet machine pressed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement including inner independent enclosures for all switches/ MCCBs/ metering equipments with hinged (bottle type) shutters, bottom gland plate with sufficient numbers of circular cable entry holes with cable glands of suitable size of cable & with suitable cable glands as per number of outgoings, prewired complete duly powder coated with 7 tank process with base frame made of angle iron 50 mm x 50 mm x 6 mm, legs 100 cm long having openable apron on all three sides of panel 30 cm wide and grouted 45 cm in PCC (1:3:6) type C-1 including brick masonary platform 45cm above ground level all as specified and directedby Engr-in.charge, comprising with following complete:- (i) Bus bar suitable for 3 phase, 415 volts, 50 Hz, 4 wire system of rating 160 Amps made out copper strip of suitable size with coloured heat shrinkable sleaves in four colours (Red, yellow, blue and black) fixed on resin cast insulators including galvanised nuts, bolts and washers etc fitted with and including the following :-
(ii) INCOMING : - (a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release, ICS=ICU=100% -01 No. (b) Panel meter of size 96x96 mm with LCD display , accuracy class 1.0, having parameters Voltage, Current, Frequency, Power factor, Power & Energy complete all as specified and directed, duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete-01 No. (c) Indicator with LED lamps for RYB , 3 Phase with MCBs set of three -01 set (iii) OUTGOING:- (a) MCCB 63 Amp, 415 V, 16 KA, 4 pole with release ICS=ICU=100% -01 No. (b) MCCB 40 Amp, 415 V, 16 KA, 4 pole release, ICS=ICU=100% -02 Nos.
Supply, installing, in replacement testing and commissioning feeder pillar, outdoor cubicle type weather and vermin proof totally enclosed made out of 3mm thick CRCA sheet machine pressed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement including inner independent enclosures for all switches/ MCCBs/ metering equipments with hinged (bottle type) shutters, bottom gland plate with sufficient numbers of circular cable entry holes with cable glands of suitable size of cable & with suitable cable glands as per number of outgoings, prewired complete duly powder coated with 7 tank process with base frame made of angle iron 50 mm x 50 mm x 6 mm, legs 100 cm long having openable apron on all three sides of panel 30 cm wide and grouted 45 cm in PCC (1:3:6) type C-1 including brick masonary platform 45cm above ground level all as specified and directedby Engr-in.charge, comprising with following complete:- (i) Bus bar suitable for 3 phase, 415 volts, 50 Hz, 4 wire system of rating 315 Amps made out copper strip of size 40 x 5mm sleaves in four colours (Red, yellow, blue and black) fixed on resin cast insulators including galvanised nuts, bolts and washers etc fitted with and including the following-02 Nos :-
(ii) INCOMING : - (a) MCCB 250 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release, ICS=ICU=100% -03 Nos. (b) Panel meter of size 96x96 mm with LCD display , accuracy class 1.0, having parameters Voltage, Current, Frequency, Power factor, Power & Energy complete all as specified and directed, duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete-03 Nos. (c) Indicator with LED lamps for RYB , 3 Phase with MCBs set of three -03 set (iii) OUTGOING:- (a) MCCB 125 Amp, 415 V, 25 KA, 4 pole with release ICS=ICU=100% -03 Nos. (b) Change over switch 250 Amps-03 Nos (c) Indicator with neon lamps for RYB, 3 phse with MCBs set of three-03 Sets
Supply, installing, testing of bus bar chamber, outdoor cubicle type weather and vermin proof totally enclosed made out of 2mm thick CRCA sheet machine pressed of suitable size, suitable to fix on wall and suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz single door with front and rear openable with locking arrangement including inner shutter for mounting switch gear etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, prewired cmplete duly powder coated with 7 tank process comprising with following complete:- (i) Bus bar strip, 4 pole and capacity 200 Amps copper strip of size 30 x 5mm based on 1.5 Amps per Sqmm, coloured with plastic coated insulated and sleaves in four colours (Red, yellow, blue and black) fixed on porcelain insulators with necessary nuts and bolts and washers etc (ii) INCOMING : - (a) MCCB 125 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release, ICS=ICU=100% -01 No. (c) Indicator with LED lamps for RYB , 3 Phase with MCBs set of three -0 set
Material and labour for shifting of transformer from existing 4 pole structure to new 4 pole structure including painting of trasnsformers with two coats of synthetic enamel paint (smoke grey) after throughly cleaning of dust, scale, grease, dirt and other foreign material and removing of existing paint and preparation of surfaces including writing of capacity and SM No./ MES No. on transformers complete all as specified and directed
Dismantling & taking down GO switch off size including insulators, operating mechanism etc complete from any position all as specified and directed
Taking down cross arms, channels, angle iron, clamps, nuts, bolts, stay wire, stay assembly, GI wire etc. complete all as specified and directed.
Taking down insulators off size & type complete all as specified and directed.
Taking down old HT PCC poles carefully and including breaking of PCC making good the diturbed surface and removing from site complete all as specified and directed.
Taking down old rusted GI pipe of any size from pole/ trench complete all as specified and directed.
Supply and fixing bracket made out of 50mm dia medium grade GI tubing 2 metre long and bent to shape at 1200 angle with stiffener on bent portion made out of MS sheet 6mm fixed with clamps, nuts, bolts, washer including painting complete with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Note : Clamps, nut, bolts and washers will be measured and paid separately.
Material and labour for sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified and directed. Note: Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire through rigid PVC conduit shall be measured as one RM.
Material and labour for sheet metal enclosure for DBs when MCBs to be used, SPN 4 ways 240 V, with 200 Amps rated bus bar, double door, epoxy coated inside and outside with neutral and earth connection bar prewired complete all as specified and directed.
Supply and fixing MCB SP 20 Amps, 10 KA, B-curve complete all as specified and directed.
Supply and fixing MCB SPN 32 Amps, 10 KA, B-curve complete all as specified and directed.
Material & labour for MCCB 125 Amps, 4 pole with thermal magnetic release, 16 KA, 415V, ICS=ICS=100% with spreader links including MCCB enclosure outdoor type complete all as specified and directed.
Supply and fixing in energy saving LED flood light 60 watt fitting made in pressure die-cast aluminium housing 100 lum/ watt 5700K potted isolated driver and high power LED and individual lences with operating range-90 volts to 340 volts fixture should with stand 320V upto 48 Hrs auto cut off >320V and restart 440 V sustain upto 8 Hrs, brand name should be embossed on fiture to ensure Indian brand only complete all as specified and directed. Notes: (i) All LED fitting shall be made in India only. (ii) Contractor shall be provided 2 years written manufacturer’s warranty for the LED fixture complete including driver from the certified date of completion. (iii) Contractor shall be produce LM-79 & LM-80 report of NABL accredited laboratory from manufacturer's local office and certificate of IP-66 and IK-08 from manufacturer.
All as per Srl Item No. 69.00 here-in-before but LED flood light 100 watt
Supply and fixing LED street light luminarie of 45 watt in epoxy powder coated pressure die-cast aluminium housing of standard dimension, heat resistant toughened clear glass fixed with SS screws controlled with potted CVCC type, BIS marked electronic driver duly enclosed capable to withstand upto 440 volts for 8 hrs of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum in circuit and 5 KV outside the driver but inside the fixture with IP-66, Class-1 protection for LED and control gear compartments with high power SMD LED chips of rating 2.5 to 3 watt (maximum) with colour temperature 5700 K (Max) and with secondary optics modular independent lenses provided with casing and capping to minimize glare and for better distribution of light suitable for voltage band 120 volts to 270 volt, having efficacy 120 lumens/ watt. Brand name should be embossed on fixture to ensure Indian brand only complete all as specified and directed. Notes: (i) All LED fitting shall be made in India only. (ii) Contractor shall be provided 2 years written manufacturer’s warranty for the LED fixture complete including driver from the certified date of completion. (iii) Contractor shall be produce LM-79 & LM-80 report of NABL accredited laboratory from manufacturer's local office and certificate of IP-66 and IK-08 from manufacturer.
Supply and fixing wiring for circuit alongwith earth wire with size 2 x 2.5 sqmm + 1x 1.5 sqmm of FR PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified. Note : Two run of 1.5 sqmm and one run of 1 sqmm cable as earth continuity conductor shall be measured and paid as one unit.
Supply and fixing SPN DB single door 2 way including MCB SPN 32A all as per specified and directed.
Supply and fixing junction box for street/security light of size 210mmx310mmx116mm made of thermoplastic IP 65 suitable for 10 Sqmm to 25Sqmm cable metric lockout for cable entry and front hinged shutter having aluminium bus bar 200Amp single phase 2 wire system to connect cable of size 10 Sqmm comprising of MCB 16 Amps-01 No. SP, fixed to pole with MS clamps of size 20x3mm, nuts, bolts and washers complete all as specified and directed.
Supply and fixing 20mm dia PVC conduit exclusive of boxes (junction/ terminal) but exclusive of all tees, bends, elbows, reducers, bell mouth tubs, ends and fixing, all accessories such as couplers, lock nuts, saddles, pipe clamps etc complete all as specified and directed
Supply and fixing automatic street light switch comprising of nature switch for automatic switching of street light based on LUX level of natural light or time periodicity (both options) the infrared sensor based nature switch alongwith lighting load of 5 KW single phase power contractor (AC3) 20-25 Amp and MCB SP on both in and outside of rating 25 Amp complete enclosed in outdoor, rust weatherproof and terminate proof FR grade SMC lockable box conforming to IP 54 contractor. MCB and circuit wiring should be 10 sqmm copper wire complete all as specified and directed.
Supply, fixing, commissioning and testing of Air Conditioner of capacity 1.5 Ton hi wall split units, indoor unit and outdoor unit air cooled type complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating including copper pipeof suitable size between indoor and outdoor unit duly insulated and copper wire flexible 3 core of size 70/.0076,, from voltage stabilizer to outdoor unit and from indoor unit to outdoor unit complete all as specified and directed. Make: Hitachi / LG/ Voltas/ Panasonic.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp 240 V 10 KA complete all as specified and as directed.
Dismantling old LT panels-01 Nos off size including bus bars-02 carefully off size complete all as specified
Dismantling existing energy meter off size and refixing with carefully in new LT panel complete all as specified
Material and labour for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe-410-W Gde-E-250 quality 'A' complete all as specified and directed
Supply and fixing mild steel work wind tie etc for roof including securing bolt, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified.
Supply and fixing Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Supply and fixing Pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Material and labour for preparation of newly plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out complete all as specified and directed
M&L for 100mm thick M-20 design mix (using 20mm graded stone aggregate as in floor laid in alternative bays finishing the surface even and smooth complete all as specified.
M&L for 100mm thick M-20 design mix (using 20mm graded stone aggregate as in floor laid in alternative bays spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified.
Forming 12mm thick expansion joints filled with preformed bituminous filler and for 30mm primed and sealed with sealing compound grade 'A' (thickness of slab in 100mm) complete all as specified.
Forming contraction (dummy joints) 65mm deep x 10mm wide filled with sealing compuound grade 'A' complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified.
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands plinth courses, roof kerbs or mud stops, benching, coping, bed plates, parapets, water through and the like etc including weathering, slightly rounded or chamfered angles throating, edges of interlocking/ chequered tiles etc complete including necessary form work complete all as specified and directed
BHARAT ENGINEERS
UNITED ENGINEERING CORPORATION
Goodwill Engineers
Northern cable fault locatoers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .