Group B: R.I.O. OT Table (Opthalmic) Portable USG with UBM for OT Hand- Held Autoref with Keratometer Hand Held Slit Lamp Rebound Tonometer Fundus Camera (non mydriatic) Neonatal Wide-field Fundus Imaging System Microdebrider and Bone Drill for Lacrimal and Orbital Surgery Radio Frequency Unit Endoscope System Diode Laser for Treatment of Ocular Tumors and for Retinoblastoma Green Laser with LIO
144198
NIT No.28/2026-2027/Bio-Medical Eqpt/IGIMS/Store/B
Open Tender
GENERAL
Sheikhpura
• Status of Bidder:
Manufacturer or Authorized Agent of the Manufacturer
Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER?S AUTHORISATION FORM as per FORMAT placed at Annexure ? III)
• Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
• Certificate towards market standing of minimum 05 years in the area of supply, installation, commissioning and maintenance of IT Equipment?s.
• Certificate for sole ownership / partnership
• Statement of financial standing from bankers
• Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
• Notary certified User List (List of Govt./Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
• Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt. /Semi Govt. /Reputed Pvt. Institutions/organization for the quoted items.
• Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the dept. or Institution after a minimum period of six months of installation
• Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
• Whether rates quoted are inclusive of all taxes or not.
• Whether rates are quoted as per format mentioned in the Bidding Document or not.
• Affidavit to the effect that the bidder is not blacklisted by any Govt. agency or has no pending case either Civil or Criminal against them.
• Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. /Semi Govt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
• Bid Security amount deposited is enclosed or not. If yes, please mention the details.
• Original Technical Catalogue of the quoted model.
• Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of three years as mentioned against each item including all spares, accessories, consumables etc., (Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
• Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of seven years after expiry of warranty period of three years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
• Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document. (Clause No- 13 of ?Instruction to Bidder ?& clause no- 3, 4 and 5 of Condition of contract.)
• Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column.
• Compliance Statement with relation to the terms & conditions as mentioned in the document.
• PAN and copies of Income Tax Returns for the last three years.
• Duly attested copy of GST registration certificate.
• Should have OEM authorization against this tender.
GENERAL
ITEM RATE
L1
1
21 documents required · 21 mandatory
₹2,500
Processing Fee: 1180
Conference Hall (Ground Floor, New Administrative Building), IGIMS, Patna
25 Nov 2026
25 Nov 2026
28 Dec 2026
25 Nov 2026
20 Dec 2026
25 Nov 2026
27 Nov 2026
180 days
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt /IGIMS/Store
A.: To be filled by the bidder and submitted along with the Technical Bid.
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Status of Bidder:
· Manufacturer or Authorized Agent of the Manufacturer
· Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER’S AUTHORISATION FORM as per FORMAT placed at Annexure – III)
2 Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
3 Certificate towards market standing of minimum 05 years in the area of supply and or maintenance of bio-medical equipments.
4 Certificate for sole ownership / partnership
5 Statement of financial standing from bankers
6 Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
7 Notary certified User List (List of Govt.
/Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
8 Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt./Semi Govt.//Reputed Pvt. Institutions/organization for the quoted items. ( same model)
9 Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the deptt. or Institution after a minimum period of six months of installation
10 Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
11 Whether rates quoted are inclusive of all taxes or not.
12 Whether rates are quoted as per format mentioned in the Bidding Document or not.
13 Affidavit to the effect that the bidder is not
blacklisted by any Govt. agency or have no pending case either Civil or Criminal against them.
14 Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. / Pvt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
15 Quality Assurance Certificate like ISI, ISO-9002, IP/BP, CE, FDA (US) or any other (please specify)
16 Bid Security amount deposited is enclosed or not. If yes, please mention the details.
17 Original Technical Catalogue of the quoted model
18 Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of three years including all spares, accessories, consumables etc.,
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
19 Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of seven years after expiry of warranty period of three years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
20 Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document.( Clause No- 13 of “ Instruction to Bidder “ & clause no- 3, 4 and 5 of Condition of contract.)
21 Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column Mere writing” Complied shall not be accepted.
22 Compliance Statement with relation to the terms & conditions as mentioned in the document.
23 PAN and copies of Income Tax Returns for the last three years.
24 Duly attested copy of GST registration certificate.
B: To be filled by the Bidder and submitted along with Price Bid
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Item wise price for the item(s) as mentioned in the Bidding Document and as per format attached as Annexure – I(a) or I (b)
2 Rate for Comprehensive Annual Maintenance Contract as per terms & conditions mentioned in the Bidding Document and as per format attached as Annexure - II
Note: If the above-tender details are not mentioned and required documents are not attached at appropriate places, the offer of the bidder(s) shall be summarily rejected. Hence, bidder(s) are advised to go through the bidding document carefully and tender be prepared with all the required documents to avoid rejection of offer.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt /IGIMS/Store
ELIGIBILITY CRITERIA Mentioned Page no.
1 Manufacturers or their authorized dealers/Indian subsidiaries/direct importers having a place of business in any of the States of India are eligible to participate in this tender.
2 The bidder and manufacturer of the equipment offered should be in the business of the supply and installation of same / similar equipment for the last five calendar years.
3 (a) The manufacturer should have completed at least 05( Five ) nos. installations of the quoted items in Govt. /Pvt. Institutions /Hospitals in India. The installations mentioned by the manufacturer in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
(b) The bids quoted as the authorized representative of the manufacturer meeting the above criteria 02 (a) should have also supplied and installed at least 03( Three) nos. installations of the quoted items in Govt. /Pvt. Institutions/ Hospitals in India in last five years from the last date of submission of tender. The installations mentioned by the authorized representative in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
4 The Bidder should be public undertaking /Autonomous Body /Public Ltd./Pvt. Ltd. Company or proprietary firm /Partnership Firm and should be in medical equipment business since last five years in India. The Bidders having manufacturing facility in their name in India for the majority of the items offered by them shall be given preference.
5 The Bidder (manufacturer or their authorized agent) should have had average annual financial turnover of Rs. 50 Lakh during the last three years ending s 31st March 2026.
6 Bidders who have the capability to attend repairs of these equipment within the time mentioned in this bidding document and who are willing to provide stand by equipment or replace the faulty equipment if the repair/down time extends beyond 72 hours from the time of reporting of the fault within the next 48 hours (total down time should not exceed 5 days in one instance). The bidders who have the capability to ensure the uptime mentioned in this document (Documentary proof shall be submitted on the after sales facilities and expertise of the bidder.)
7 Bidders are not offering the equipment of a firm /company that has
been blacklisted by Indira Gandhi Institute of Medical Sciences – Patna or blacklisted/debarred by any other State / Central Government's organization.
Note: Notwithstanding anything stated above, the Institute reserves the right to assess the Bidder’s capability and capacity to perform the contract satisfactorily before deciding on award of contract, should circumstances warrant such an assessment in the overall interest of the purchaser.
The Institute reserves the right to ask for a free demonstration of the quoted equipment at a pre determined place acceptable to the purchaser of technical acceptability as per the tender specification, before the opening of the price tender.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- Group B
1: OT Table (Opthalmic); Qty: 07 No.
Technical specification
1. Should be motorized table with ophthalmic head piece and adjustable wrist support.
2. Should have operated on foot – pedal control for up and down movements.
3. Should be provided with non-wettable and antistatic mattress cover.
4. Locks to stabilize when in use with high quality rust-proof castors.
5. Should have table top movements essential for ophthalmic surgery.
6. The table should have trendelenburg and reverse trendelenburg movement. With Forward & Reverse tilting (More than 20 ̊)
7. Should be able to lift weight of atleastAppox 150 kg- 190kgs.
8. Should be supplied with Chair- pneumatic stool with backrest height adjustment and ergonomic Seat foam. (Ophthalmic Surgeon chair)
9. Height should be approx 590mm to 790mm.
10. Length should be approx 1600-1800mm.
Electrical specification
Input voltage 230 va.c/ 50/60 Hz
Quality certification Required US FDA CE IOS, Etc
Should be FDA or CE or BIS or ISO and STQC certified product.
2: Portable USG With UBM for OT; Qty. 01 No.
Technical specification
Immersion or direct contact A-scan
Manual or automatic capture with different modes
Auto calculation of axial length, anterior chamber depth, lens thickness, and vitreous, with axial length average and standard deviation provided for up to 10 scans per exam
Standard IOL formulas: Binkhorst, Regression-II, Theoretic/T, Holladay
12 and 20 MHz frequency transducers available for posterior B-scan
256 ray scan with 2048 sample points for each ray
Capture configurable length video clips at up to 20 frames per second
Store unlimited images and configurable number of video clips in each exam B-Biometry parameters used for into preferred formulas for calculation of IOLs
35 and 50 MHz frequency transducers for UBM
256 ray scan with 2048 sample points for each ray
Capture configurable length video clips at up to 20 frames per second
Store unlimited images and configurable number of video clips in each exam.UBM kit for direct contact UBM scanning
Accurate and automatic corneal thickness measurements
Auto self-calibration check and probe test
Adjustable tissue velocity
Single point or multiple point map with single or multiple readings at each point
For central corneal thickness (CCT) and peripheral measurements
Portable printer small laser
3: Hand-held Autoref with keratometer; Qty. 02
Technical specification
Objective should measure corneal astigmatism.
Measurable range sphere ≥ plus/ minus 20D, Cyl ≥ 10D, Axis 0 to 180, min.
pupil size 2.0, 2.3mm, vertex dist. 10.5, 12.0, 13.5,
preferably with IOL mode and print out facility.
Light in weight
Auto keratometer measurement range–
Curvature radius 5.00 to 13.00 mm (0.01 mm increments)
Refractive power 25.96 to 65.50 D (0.12 / 0.25 D increments)
Cylindrical power 0 to ±12.00 D (0.12 / 0.25 D increments)
Axis 0 to 180º (1° / 5° increments)
Electrical specification
AC 100 to 240 V, 50 / 60 Hz/ BATTERY OPERATED FOR ADEQUATE BACKUP
Quality certification Required US FDA CE 10S, Etc
US FDA CE, ISO, BIS
4: Hand held slit lamp; Qty. 02
Technical specification
• Compact and lightweight, so that the examiner can hand hold the unit over a long period with minimal fatigue.
• Extra-bright halogen lamp light source.
• Easy, simple selection of one of three slit widths or spot illumination.
• Quick, one-touch selection of 6x or 10x magnification.
• Built-in blue filter.
• Stand doubles as a battery recharger box case for carrying
Electrical specification
The equipment should be rechargeable, cordless power supply for slit-lamp examination anywhere
Quality certification Required US FDA CE 10S, Etc
US FDA CE ISO BIS
UPS requirement
Suitable UPS with maintenance free batteries for minimum one-hour back-up should be supplied with the system
5: Rebound tonometer; Qty. 02
Technical specification
DIMENSIONS 43 mm (W) * 104 mm (H) * 214 mm (L)
WEIGHT 165 g (without batteries), 260 g
(with 4 x AA batteries)
MEASUREMENT RANGE 7 mm Hg – 50 mm Hg
ACCURACY ± 1.2 mm Hg (≤ 20 mm Hg) and
± 2.2 mm Hg (> 20 mm Hg)
REPEATABILITY < 8 % (coefficient of variation)
Can be used in SUPINE, ELEVATED AND SEATED position
Electrical specification
POWER SUPPLY 4 x AA non-rechargeable batteries, 1.5 V alkaline LR6
6: Fundus camera (non mydriatic); Qty. 02
Technical specification
Angle of Coverage: Minimum 45° standard field of view for clear macula and optic disc capture.
Minimum Pupil Diameter: ≤ 3.3 mm (enables imaging small pupils without mydriatic eye drops).
Light Source: Low-flash white LED for color imaging and infrared (IR) LED for patient alignment and preview.
Focus Adjustment Range: Approx. -15D to +15D (nsuffla) or wider with correction lenses.
Sensor Resolution: ≥ 5 megapixels providing sharp digital clarity for diagnostic telemeine
Electrical specification
Laser printer/motorized INDIAN table
Quality certification required US FDA CE ISO, Etc
US FDA/CE or equivalent
UPS requirement
With online backup of 30 minutes
7: Neonatal Wide-field Fundus Imaging System Qty. 01
Technical Specifications
1 Clinical application : Digital wide-field retinal imaging system for neonatal and pediatric retinal examination including ROP screening.
2 Field of View: 120° field of view or better in a single capture.
3 Illumination: LED-based illumination or other compliant with retinal safety standard.
4 Imaging: High-resolution colour fundus imaging with digital zoom and image enhancement.
5 Video: Real-time video recording with frame rate suitable for clinical documentation.
6 Still images: Capture high-quality still images during live examination.
7 Software: Image review, annotation, rotation, measurement and reporting functions.
8 Storage: Automatic storage of images/videos with patient database.
9 Export: JPEG/TIFF/PNG and DICOM export where applicable.
10 Sensor: CMOS or superior imaging sensor.
11 FA: Should support fluorescein angiography.
12 Power : Integrated rechargeable battery or supplied UPS providing ≥2 hours operation.
13 Computer: Laptop/Desktop/workstation with licensed operating system and sufficient configuration for supplied software. And should also provide a separate desktop with 27 inch UHD monitor or better and minimum 4TB storage, 32GB RAM and Latest generation intel processor (Core Ultra 200HX or better) or AMD processor (Ryzen 9000 HX or Better).
14 Connectivity: USB and/or LAN/Wi-Fi for data transfer.
15 Electrical: 220–240 VAC, 50 Hz.
17 Regulatory: Product shall possess valid CDSCO Registration and/or CE and/or US FDA approval as applicable.
18 Training: On-site installation and user training.
8: Microdebrider and Bone Drill for Lacrimal and Orbital Surgery; Qty. 01
Technical Specification
• Powered microdebrider and high-speed drill
• High-speed ENT microdebrider handpiece
• Up to ~30,000 rpm with oscillation and forward modes; fine incremental speed control
• Direct-drive, gearless handpiece with straight-through suction and ergonomic design
• Compatibility with wide range of blades (2.9–4.3 mm) for lacrimal and orbital work
• Integrated irrigation via console pump and dedicated tubing sets
• High-speed bone drill system with high torque and compact handpiece
• Straight and angled drill attachments including variable-exposure attachments for controlled bone removal
• Full set of cutting and diamond burs (2.0–4.0 mm diameter, straight and curved) for DCR and orbital decompression
• Multifunction footswitch for activation, speed and mode control
• Equipment suitable for endoscopic lacrimal and orbital surgery under endoscope or microscope
Electrical Specification
• Power: 100–240 V AC, 50/60 Hz (wide-range input)
• Maximum power consumption approx. up to 500 VA (or as per OEM datasheet)
• Protection and safety as per IEC 60601-1 standards for medical electrical equipment
• System compatible with hospital UPS / isolation transformer (single phase 230 V in India)
9: RADIO FREQUENCY UNIT; Qty. 01
Technical specification
· Cutting-edge technology 4MHz (monopolar) and 1.7- 4MHz (bipolar) radiofrequency surgery unit
· Microprocessor controlled
· Combines the well-known tissue sparing effects of radiofrequency with innovations of the output power control
· Extremely wide spectrum of clinical applications – suitable for electrosurgery or RF surgery in human
· multiple operating modes
· Each mode can be selected with only one touch
· Settings of each mode are stored independently and kept even when the unit is switched off
· Indicators show the actual setting in Watts
· Timer can be used in each mode to secure reproducibility of certain procedures
· Leakage current control system
· Output power failure detection system
· Forceps and electrodes should be non-sticky
· Digital LED / LCD display for mode and power output
· Minimum lateral heat (tissue damage) effect (<50microns)
· Inbuilt cooling system
· 3-year warranty
• Set of Monopole Electrodes Including: Round Loop, Triangle Loop, Diamond Loop, Straight Needle, Ball Electrode, Broad Needle – Bent Tip, Vari-Tip, Colorado tip
• Tightening Probes QTY UOM
• Twin footswitch
• Bipolar cable
• Bipolar forceps
• Reusable finger-switch handle
• Reusable finger-switch electrode/ plate
• Single use split neutral electrodes (NE)/plate
• Reusable cable for split neutral electrodes (NE)/plate
10: Endoscope System Qty. 01
Technical Specification
Rigid Telescopes (0° & 30°, 2.7 mm and 4 mm; rod-lens; autoclavable)
· Length- 175-180mm
• Lacrimal Microendoscope (0.65–0.85 mm; 110° field; micro-sheath; irrigation port)
• IMAGE1 S Full HD Camera Platform with 3-chip camera head (autoclavable)
• Digital enhancement (CLARA / CHROMA / SPECTRA)
• LED 120-180 W or Xenon 300 W Light Source, Colour temperature approximately 5500- 6500K, automatic brightness control, light cable included
• 24” or 32” Full HD Medical Grade Monitor (1920×1080, 16:9), HDMI, FULL HD or 4K
· Fibre optic light cable: diameter: 3.5-4.8mm, length: 2.3-3m, autoclavable, compatible with endoscope and light source
• HD Documentation System (still/video recording; USB/PACS)
• Irrigation System
• Autoclavable optics; anti-reflective coatings; compatible with Storz cables
Electrical Specification
• Camera Control Unit: 100–240 V AC, 50/60 Hz, HDMI/DVI/ SDI output
• Light Source: 110–240 V AC, 50/60 Hz
• Monitor: 100–240 V AC, 50/60 Hz
• AIDA Documentation System: 100–240 V AC, 50/60 Hz
• UPS / Isolation transformer compatible
• IEC 60601-1 compliant
Compatible with standard HD camera systems
CE/ FDA approved or equivalent certification.
Accessories Required
• Fiber optic light cables (2 autoclavable; 180–230 cm)
• Irrigation/suction tubing sets
• Sterilization trays for rigid scopes and microendoscope
• Equipment trolley with shelves and cable management
• Swivel monitor arm :USB recording
· Still image capture
· Video recording
· Internal storage or external USB support
Warranty: Minimum 3 years comprehensive warranty
11: DIODE LASER FOR TREATMENT OF OCULAR TUMORS AND FOR RETINOBLASTOMA Qty. 01
Cooling: No external air or water cooling required
1. Laser Power : Infrared Diode Laser (810mm
2. Aiming Laser: ) 0 – 3000 mW
3. Power : Red diode laser (650-670nm) 0 - <1.0 mW
4. Delivery Devices : LIO (1.4mm spot size)
5. Treatment Modes: CW-Pulse, Micropulse, Long Pulse
6. Pulse Durations :CW-Pulse 30 ms - 9000ms Long Pulse 10 sec. - 30 min Micropulse.1ms - 1.0ms Duration 1.0ms - 10 ms Interval
7. Optional Delivery Devices Normal Spot Laser Indirect Ophthalmoscope
Extra Probe for Transscleral Cyclophotocoagulation
Electrical specification
Electrical 115 VAC, 50/60 Hz, 0.8 Amps, 230 VAC, 50/60 Hz, 0.4 Amps
Quality certification Required US FDA CE IOS, Etc
CE / US FDA approved.
12: GREEN LASER with LIO Qty. 02
Technical Specification
Delivery system: (LIO)
LASER TYPE: Diode pumped, frequency doubled, true cw& solid state. (Medical Grade), 532nm.
THERAPY LASER POWER Between1.3-1.5 W at the cornea
PULSE DURATION: 10-2500 ms (CW) (Single Pulse)
COOLING: thermoelectric/ air cooled
Pilot/ Aiming Laser: 635-650 nm Red diode laser
Should be CE or FDA Approved
-Laser safety eye glasses-2 No.
Endolaser fIBER 23 Ga Bent -15 No.
Endolaser Fiber 23 Ga Straight-15 No.
LASER Connecting Optical Fiber to LIO-1 extra apart from supplied with the Unit
Supply of Either 28 Diopter/22 Diopter/20 Diopter FDA approved Retinal Lens
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/2026-2027/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- B
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
LOCATED WITHIN INDIA.
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
EMAIL ID OF AGENCY
Scheduled Brief description of goods Make: Model: Country of origin Qty./Nos. Ex-factory/ Ex-warehouse/ Ex-Showroom/ off-the shelf (a) Excise duty (If any) % and value. (b) GST (If any) % and value (c) Pcaking and forwarding charge (d) Inland transportation, isurancer for a period inculing 3 months delivery, loading/unloading and incidental cost till consignee site. (e) Incidental services (Including installation and commissioning, supervision, demonstration and training) at the consignee site. (f) Unit Price( at consingee site basis (g) a+b+c+d+e+f Total unit price (at consignee site) Basis Rs. 4x5 (g)
TOTAL AMOUNT IN FIGURE
TOTAL AMOUNT IN WORDS
Note: Bidders are requested to submit price bid in above format otherwise the bid submitted will be regected.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 28/ 2026-2027/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- B
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 1180
COMPREHINSIVE ANNUAL MAINTENANCE CONTRACT PRICES SCHEDULE
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
S. No. Item Description 1st Yr. 2nd Yr. 3rd Yr. 4th Yr. 5th Yr. 6th Yr. 7th Yr. Total Comprehensive annual maintenance contract over a period of seven years after expiry of warranty period of three years from the date of successful installation. (a+b+c+d+e+f+g)
a b c d e f g h i
1 Name of the equipment Make: Model: Qty:
2 Name of the equipment Make: Model: Qty:
3 Name of the equipment Make: Model: Qty:
4 Name of the equipment Make: Model: Qty:
5 Name of the equipment Make: Model: Qty:
6 Name of the equipment Make: Model: Qty:
7 Name of the equipment Make: Model: Qty:
8 Name of the equipment Make: Model: Qty:
9 Name of the equipment Make: Model: Qty:
10 Name of the equipment Make: Model: Qty:
11 Name of the equipment Make: Model: Qty:
12 Name of the equipment Make: Model: Qty:
13 Name of the equipment Make: Model: Qty:
14 Name of the equipment Make: Model: Qty:
15 Name of the equipment Make: Model: Qty:
16 Name of the equipment Make: Model: Qty:
17 Name of the equipment Make: Model: Qty:
18 Name of the equipment Make: Model: Qty:
19 Name of the equipment Make: Model: Qty:
20 Name of the equipment Make: Model: Qty:
Scope of contrct (details as mentioned in the clause No. - 13 of "Instruction to Bidder" & Clauses No. 3,4 and 5 of Condition of Condition of Contract".)
a) The rate of Comprehensive Annual Maintenace Contract as mentioned above shoul cover the Complete system.
Complete System should include the basic unit and allied supporting components like UPS, stabilizer Computer System,
Printer, De-ionizer, dehumififer etc to be supplied by the bidder along with basic unit.
b) Preventifve maintenance visit: Four Maintenance visits at ragular interval for usual mintenance & supervision failing which
25% of the contract amount per visit would be deducted as penalty.
c) Break down maintenance visit: As & when requrd
d) Response Time: Within 48 Hours.
e) Uptime Guarantee: 95% of 365 days
f) The above-mentioned charges should includes labour charges for maifntenance and breakdown visits per year, spares,
accessories and all type of consumables requird for the maintenaed charges: it should be clearly mentiond with frequency of
replacement and with rate. The validity of rate of suchf items should also be mentioned vclearly. What will be the rate of
such item must be mentioned.
g) Payment of Comprehensive Annual Maintenance Contract would be made on half yearly basis after completion of work and
satisfctory working report . In no case, advance payment is to be considerd.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Bidding 28.pdf
NIT • 1.00 MB
Tender Notice (Website).pdf
NIT • 0.55 MB
TechnicalSheet.xls
NIT • 0.11 MB
PriceBid.xls
NIT • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .