| 1 | L2₹41.9 L+₹9.2 L (28.0%)Accepted-AOC | L2 | Accepted-AOC L2 | |
| 2 | L1₹32.7 LRejected-AOC 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L1 | Rejected-AOC L1 |
Tender Value
₹44.3 L
EMD Value
₹88,700
Closing Date
25 Jun 2022, 6:00 pmClosed
SH A P SINGH, IDSE, CWE CHM
HQ CWE CHANDIMANDIR
CA NO CWE/CHM(U)-03/2022-23 REPAIR AND MAINTENANCE OF 9 MLD STP UNDER AGE E/M-II OF GE (U) CHANDIMIANDIR
2022_MES_520211_2
CWE/CHM(U)-03/2022-23
Open Tender
Miscellaneous Works
Works
334 days
HQ CWE CHANDIMANDIR
class D cat c(vii)
8 documents required · 8 mandatory
₹500
Yes
GE (U) CHANDIMANDIR
₹88,700
Yes
18 Aug 2022
4 Jun 2022
30 Jun 2022
4 Jun 2022
25 Jun 2022
11 Jun 2022
Amount
Taking down carefully centrifugal pump set 75 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, inlet, delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on load for smooth operation , complete all as specified and as directed. Spare parts if any required to be replaced shall measured and paid under respective schedule of items here in- after item Sl No 1.1 to 1.11. Cost of fixing of any defective part/spare shall be deemed to be included in quoted rates. Make of pump:- KSB.
Supply only pump shaft sleeve made of gun metal suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only key for main shaft/impeller (SS 410) suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only check nut suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only stuffing box bush suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only motor pump M S coupling with spacer LR 226 type complete with nut, bolts etc suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only stuffing box packing and greasing suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only star coupling type LR-226 suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only pump set bearing housing DE/NDE of CI grade FG 210 suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only ball bearing (roller/ thrust/ any other type) DE/NDE suitable for 75HP motor pump as per manufacturer's design complete all as specified and as directed. Note. All the items/parts mentioned srl 1.01 to 1.11 here-in-before shall be suitable/ compatible for the type and make of pumping set as mentioned in item No. 01 here-in-before and cost of fixing of items shall deemed to be included in the quoted rate of item No. 01
Taking down carefully centrifugal pump set 10 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, inlet, delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on load, complete all as specified and as directed.Spare parts if any required to be replaced shall measured and paid under respective schedule of item here in- after item Sl No 2.01 to 2.10. Note. cost for fixing of any defective part/spare shall deemed to be included in quoted rates. Make of pump:- Kirloskar/ Cromptom Greaves/ Bharat Bijlee.
Supply only pump shaft sleeve made of gun metal suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only key for main shaft/impeller (SS 410) suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only check nut suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only stuffing box bush suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only motor pump M S coupling of suitable size complete with nut, bolts etc suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only stuffing box packing and greasing suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only tyre coupling of suitable size suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only cast iron impeller suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only ball bearing (roller/ thrust/ any other type) DE/NDE suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed. Make - NBC, SKF,ABC Note: All the items/parts mentioned srl 2.01 to 2.10 here-in-before shall be suitable/ compatible for the type and make of pumping set as mentioned in item No 2 here-in-before and cost of fixing of items shall deemed to be included in the quoted rate of item No. 02
Taking down carefully centrifugal pump set 7.5 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, inlet, delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load forsmooth operation, complete all as specified and as directed. Spare parts if any required to be replaced shall measured and paid under respective schedule of item here in- after item Sl No 3.01 to 3.09. Note. Cost for fixing of any defective part/spare shall deemed to be included in quoted rates. Make of pump:- KSB, Kirloskar, Mather platt or any Make existing on site.
Supply only pump shaft sleeve made of gun metal suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only key for main shaft/impeller (SS 410) suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only check nut suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only stuffing box bush suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only motor pump M S coupling of suitable size complete with nut, bolts etc suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only tyre coupling of suitable size suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only cast iron impeller suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only ball bearing (roller/ thrust/ any other type) DE/NDE suitable for 7.5HP motor pump as per manufacturer's design complete all as specified and as directed. Make - NBC Note: All the items/parts mentioned srl 3.01 to 3.09 here-in-before shall be suitable/ compatible for the type and make of pumping set as mentioned in item No 03 here-in-before and cost of fixing of items deemed to be included in the quoted rate of item No. 03
Taking down carefully multi stage booster pump set 5 HP by unscrewing nuts/ bolts of coupling, foundation, inlet, delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on load, complete all as specified and as directed. Spare parts if any required to be replaced shall measured and paid under respective schedule of item here in- after item Sl No 4.01 to 4.04. Note. Cost for fixing of any defective part/spare shall deemed to be included in qouted rates. Make of pump:- KSB, Kirloskar, Mather platt or any Make existing on site.
Supply only pump shaft sleeve made of gun metal suitable for 5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only key for main shaft/impeller (SS 410) suitable for 5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only motor pump M S coupling including rubber coupling of suitable size complete with nut, bolts etc suitable for 5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only ball bearing (roller/ thrust/ any other type) DE/NDE suitable for 5HP motor pump as per manufacturer's design complete all as specified and as directed. Make - NBC/SKF/ ABC Note: All the items/parts mentioned srl 4.01 to 4.04 here-in-before shall be suitable/ compatible for the type and make of pumping set as mentioned in item No 4 here-in-before and cost of fixing of items shall deemed to be included in the quoted rate of item No. 4.
Taking down carefully monoblock pump set up 0.5 to 3 HP by unscrewing nuts/ bolts of coupling, foundation, inlet, delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on load, complete all as specified and as directed. Spare parts if any required to be replaced shall measured and paid under respective schedule of item here in- after item Sl No 5.01 to 5.06. Note. Cost for fixing of any defective part/spare shall be deemed to be included in quoted rates. Make of pump:- KSB, Kirloskar, Mather platt or any Make existing on site.
Supply only pump shaft sleeve made of gun metal suitable for 0.5 to 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only key for main shaft/impeller (SS 410) suitable for 0.5 to 3 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only check nut suitable for 0.5 to 3HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only motor pump M S coupling including rubber coupling of suitable size complete with nut, bolts etc suitable for 0.5 to 3HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only cast iron impeller suitable for 0.5 to 3HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only ball bearing (roller/ thrust/ any other type) DE/NDE suitable for 0.5 to 3 HP motor pump as per manufacturer's design complete all as specified and as directed. Make - NBC/SKF/ABC Note. All the items/parts mentioned srl 5.01 to 5.06 here-in-before shall be suitable/ compatible for the type and make of pumping set as mentioned in item No 5 here-in-before and cost of fixing of items shall deemed to be included in the quoted rate of item No. 5
Dismantling and taking up non-clog submersible motor pumpset 20 HP, 3 phase complete with submersible motor including connected pipes of size 150/200 mm from the sludge well after dis-connectibng the electric connections, shifting the same to the workshop for repair/ servicing. The job includes strip opening of pump and motor, replacement of defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on load, complete all as specified and as directed. Spare parts if any required to be replaced shall measured and paid under respective schedule of item here in- after item Sl No 6.01 to 6.03. Note. Cost for fixing of any defective part/spare shall deemed to be included in quoted rates. Make of pump:- KSB, Kirloskar, Mather platt or any Make existing on site.
Supply only bronze impeller suitable for 20HP submersible pump set seven stage as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 20HP submersible pump set as per manufacturer's design complete all as specified and as directed.
Supply only neck rings suitable for 20HP submersible pump set as per manufacturer's design complete all as specified and as directed.
M&L for strip opening of submersible motor capacity 20 HP , 3 phase, taking out burnt winding carefully, cleaning of slots, rewinding of the same with super enamelled copper winding wire of appropriate size matching with manufactures design, including replacement of all insulating materials such as glass paper, insulated sleeves, varnishing, drying up as applicable, re-assembling including coupling of motor with pump complete all as specified and as directed. .
Taking down defective electric motor, squirrel cage type of any make, from base plate after unscrewing nuts, bolts of foundation/ coupling (approx weight 600kg), 3 phase, 415/440 volts, 50 c/s, AC, capacity 75 HP, shifting the same to workshop, strip opening after unscrewing nuts, bolts/ screws etc. taking out rotor from stator, cutting and taking out burnt winding carefully from the stator, cleaning of slots, rewinding of stator with super enameled copper winding wire of appropriate size matching with manufacturer's design including replacement of all insulating materials such as glass paper, leathered paper, PVC insulated copper conductor wire connection leads of appropriate size with sleeves of suitable size upto terminal connection box, varnishing, drying up and re-assembling, re-fxing and re-installation at site and testing on load all as specified and directed by Engineer-in-Charge. Note:- Required T&P such as chain pulley block and tranportation shall be contractors responsibility and cost of same shall deemed to be included in quoted rates. Repair/ replacement shall be done within a period as intimated by the Engr-in-Charge falling which necessary recovery @ 500/ day shall be deducted from contractor dues. (iii) Repair shall be done from any workshop within a radius of 5KM from GE(U) Chandimandir.
All as per item No 08 here-in-before but 50 HP motor (approx weight 350kg).
All as per item No 08 here-in-before but 15 HP motor (approx weight 70kg).
All as per item No 08 here-in-before but 10 HP motor (approx weight 50kg).
All as per item No 08 here-in-before but 7.5 HP motor (approx weight 30kg).
All as per item No 08 here-in-before but 5 HP motor (approx weight 20kg).
Taking down from the foundation 50 HP Air blower unit (Approx height 4 ft and weight 350 kg) after unscrewing nut, bolt washer, strip opening the blower unit for servicing and replacement of gear box , reassembling, refilling of gear oil and testing complete all as specified and directed.
Taking down from the foundation 10 HP Air blower unit (Approx height 4 ft and weight 350 kg) after unscrewing nut, bolt washer, strip opening the blower unit for servicing and replacement of gear box , reassembling, refilling of gear oil and testing complete all as specified and directed.
Supply and Fixing in replacement pressure gauge , analog type with circular dia of 150 mm with reading capacity upto 2.5kg/cm2 for fixing on inlet sewage well pipes for checking inlet sewage pressure into greet chamber after pumping through non-clog submersible pumps. Make:- HGURU/FEIBIG/RADIX
Material and labour for Carrying out cleaning of grit chamber (chamber collecting sewage water directly after pumping) along with regular preventive maintenance of conveyor belt with whole gear mechanism by regular oiling greasing,any welding work etc. and replacement of following spares: Note : Cost of any minor spare parts used in regular cleaning/maintenance of above item shall deemed to be included in the quoted rates. Neccesary safety equipments and tools required to the job will be provided by the contractor, safety of labour shall be the sole responsibility of the contractor.
Supply and fixing in replacement Sprocket for conveyor belt gear mechanism of suitable size complete all as specified and as directed.
Supply and fixing in replacement Conveyor belt rubber material of suitable size complete all as specified and as directed.
Taking down defective gate valve of following sizes for preventive maintenance including regular oiling , greasing and minor repairs with servicing and refixing the same and checking for smooth function complete all as specified and directed. Note : Cost of any minor spare parts used in regular maintenance of above item shall deemed to be included in the quoted rate.
All as per item No 20 here-in-before but 100 mm
All as per item No 20 here-in-before but 150 mm
All as per item No 20 here-in-before but 250 mm
M&L for Carrying out cleaning of MBBR Tank 1 & 2 by draining the sluge/water by emptying tank and scraping out the dirt from the walls and floor of the tank manually or using mechanised system along with changing media upto 30% as and when directed by Engr-in-Charge and washing with clear water complete all as per directed. Note : Cost of Any minor spare parts used in regular cleaning/maintenance of above item shall deemed to be included in the quoted rates. Neccesary safety equipments and tools required to the job will be provided by the contractor, safety of labour shall be the sole responsibility of the contractor.
M&L for Carrying out cleaning of secondary clari floculator Tank by draining all of water from the tank and removing dirt, algae from the walls and floor of the tank manually or using mechanised system along oiling and greasing of mechanical parts also painting the entire tank with anti-corrosive paint all as directed by Engr -in-Charge Note : Cost of any minor spare parts used in regular cleaning/maintenance of above item shall deemed to be included in the quoted cost.Neccesary safety equipments and tools required to the job will be provided by the contractor, safety of labour shall be the sole responsibility of the contractor.
Taking down butterfly valve of size 180/200 mm dia and repairing its gear box for any wear tear and oiling and greasing the entire valve for preventing any further breakdown and refixing the same at original position complete all as specified and directed. Note : Any minor spare parts used in regular maintenance of above item shall deemed to be included in the quoted cost.
Supply and fixing in replacement CI butterfly valve of size 12 inches dia and dismantling the old valve at the location as directed by Engineer-in-Charge.
Carrying out servicing and preventive maintenance of Drexel Water monitoring System for checking water parameters of the treated water before supplying it, including cleaning of sensors, UPS repair, Monitor repair or any malfunctioning occuring in the system complete all as specified and directed.
Carrying out servicing and preventive maintenance of Water Level Sensor System for checking water levels of the treated water sump and overhwad sump (used for backwash), including cleaning of sensors, Sensor replacement, minor repair or any malfunctioning occuring in the system complete all as specified and directed.
M & L for preparing old painted steel surfaces of over 10 cm in width or girth and applying one coat of synthetic enamel paint as per the colour standard specified by the Engineer-in-Charge.
Supply and fixing glow signage board of the enitre layout of the 9 MLD STP plant along with the marking of all the rooms, MBBR tanks, Clari-faeculator tanks etc. on the board with base frame made from angle iron and back side form ACP sheet 3mm thick with IP 68 protection LED module, good quality virgin monomer acrylic sheet, 3 inch rising moulding of acrylic letter with 5mm sun board channel, including complete wiring and SMPS power supply with IP 68 protection, Each letter will be made with computer offset for having same letter style and type as approved by Engineer-in-Charge, complete all as specified and directed.
M&L for preparing new plastered surfaces on walls and applying three coats of whitewashing complete all as specified and directed.
M&L for preparing new plastered surfaces on ceilings and applying three coats of whitewashing complete all as specified and directed.
M&L for preparing old plastered surfaces on walls and applying two coats of whitewashing complete all as specified and directed.
M&L for preparing old plastered surfaces on ceilings and applying two coats of whitewashing complete all as specified and directed.
M&L for preparation of old plastered surface washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of cement based paint complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone concrete or bricks surrounds, glazed with putty or fixed with beads.
Supply & fixing 3mm thick sheet glass, ordinary quality in square size not exc 0.5 sqm in each pane fixed with oil putty or wooden beads & leaving the panes clean on completion.
Taking down cement plaster on brick or concrete or stone walls surface including racking out joints, hacking for keys, scrubbing down with water etc complete all as spd and directed.
Materials & Labour for 15mm thick cement plaster in CM 1:4 on brick or concrete wall external surfaces of any description finished even and fair without using extra cement complete all as specified.
Materials & Labour for 10mm thick cement plaster in CM 1:6 on brick or concrete wall internal surfaces of any description finished even and smooth without using extra cement complete all as specified.
Materials & Labour for 5mm thick cement plaster in CM 1:3 on concrete ceiling surfaces of any description finished even and smooth without using extra cement complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches pillars etc complete all as specified and as directed.
M&L for Brick work with sub-class “B” bricks straight or curved in plan exceeding 6mtr mean radius with old size bricks in cement mortar 1:6 complete all as specified and as directed.
M & L for removal of existing unserviceable filter media from filter bed of size 8mtr (L) x 4 mtr (W) x 2 mtr (D) of filtration plant and disposal of unserviceable media/material from each filter bed to a designated place, distance not exceeding 50 mtr including dismantling of existing air blow-down piping system, dismantling of AC lateral pipes and header block tees, nozzles etc, cleaning and disinfection of entire internal surface of the filter bed using a suitable cleaning agent/bleaching powder, scrubbing the side walls to remove any form of deposit using a wire brush and including laying and leveling filter media complete all as specified and directed. Note : (a) Only one number of Rapid Gravity Filter Bed is to be taken for overhauling at a time and the same shall be carried out as per instruction and as directed by Engineer-in-Charge. (b) Prior to starting of overhauling of a filter bed, the required materials for overhauling shall be made available at site. (c) Entire materials labour, Engineer, supervisor, plant & tools required for executing the work and for safety of persons deployed on the work shall be contractor’s arrangement and responsibility. (d) During dismantling, a joint inspection will be carried out by Engineer-in-Charge with contractor and the detail of the filter media layers will be drawn. The new filter media layers are to be placed as per the details drawn during the joint visit. Note.Filter media shall be measured and paid seperately under respective items here-in-after under Ser item No 43 to 45. Cost of laying and levelling for filter media shall deemd to be included in quoted rates of item No 42.
Supply only filter media comprising of graded gravel, in accordance with IS: 8419 Part-I, specific gravity not less than 2.5, free from clay, sand, loam and organic impurities of any kind, Acid solubility not more than 10.00 %, Particle size 20mm-25mm, complete all as specified and directed.
All as per item No.43 here-in-before but of particle size 10mm-15mm complete all as specified and as directed.
All as per item No.43 here-in-before but of particle size 3mm-5mm complete all as specified and as directed.
Supply, laying and levelling filter media comprising of filter coarse sand, in accordance with IS: 8419 Part-I, specific gravity not less than 2.5, uniformity coefficient less than 1.5, Silica content tested in accordance with IS: 2000, Any sample of filter sand shall not contain more than 5 percent by volume of impurities, such as clay, loam, silt, Loss in Ignition not more than 0.70 %, Acid solubility not more than 5.00 %, Particle size 1mm-2mm, complete all as specified and directed.
Supply laying and levelling filter media comprising of crushed coconut powder with activated carbon for water treatment, in accordance with relevant IS, specific gravity not less than .35. Any sample of crushed coconut powder shall not contain more than 5 percent by volume of impurities, such as moisture, clay, loam, silt, Loss in Ignition not more than 0.70 %, Acid solubility not more than 5.00 %, Particle size 1mm-2mm, complete all as specified and directed.Note: For item No 41 to 45: The filter media shall conform to all the parameters mentioned in the relevant IS code and a test certificate in this regard from supplier and from an NABL accredited laboratory is to be submitted for approval of GE before incorporating in work complete all as specified and as directed.
Supply and fix in replacement 3 pole power contactor MNX-A2 and MNX-A1 complete all as specified and directed.
Supply and fixing in replacement MCCB, triple pole, 400 Amp 415 volts. 50 Hz breaking capacity not less than 35 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed
Supply and fixing in replacement MCCB, triple pole, 630 Amp 415 volts. 50 Hz breaking capacity not less than 50 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed.
Supply and fixing in replacement MCCB, triple pole, 200 Amp 415 volts. 50 Hz breaking capacity not less than 35 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed.
Supply and fixing in replacement MCCB, triple pole, 250 Amp 415 volts. 50 Hz breaking capacity not less than 35 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed.
Supply and fixing in replacement 5 to 32 Amps MCB SP 10 KA , C Curve complete all as specified and as directed.
Supply and fixing in replacement Heavy Duty Cylindrical Capacitors 7.5 KVAR complete all as specified and as directed. Make: ABB/ Havells/ SCHNEIDER
Supply and fixing in replacement Heavy Duty Cylindrical Capacitors 10 KVAR complete all as specified and as directed. Make: ABB/ Havells/ SCHNEIDER
Supply and fixing in replacement Heavy Duty Cylindrical Capacitors 15 KVAR complete all as specified and as directed. Make: ABB/ Havells/ SCHNEIDER
Supply and fixing in replacement Heavy Duty Cylindrical Capacitors 20 KVAR complete all as specified and as directed. Make: ABB/ Havells/ SCHNEIDER
Supply and fixing in replacement duty contactor 10 KVAR Inbuilt 1 NO/NC auxiliary contact complete all as specified and directed. Make: ABB/ Havells/ SCHNEIDER
Supply and fixing in replacement duty contactor 12 KVAR Inbuilt 1 NO/NC auxiliary contact complete all as specified and directed. Make: ABB/ Havells/ SCHNEIDER
Supply and fixing in replacement duty contactor 15 KVAR Inbuilt 1 NO/NC auxiliary contact complete all as specified and as directed. Make: ABB/ Havells/ SCHNEIDER
Material and labour for finding minor fault in the main panel and providing in replacement worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable complete all as specified and directed.
Supply and fixing in replacement HRC Fuse 250/200/150 Amps complete all as specified and as directed.
Supply and fixing in replacement CT of 300/5 including complete wiring complete all as specified and as directed.
Supply and fixing in replacement CT of 200/5 including complete wiring complete all as specified and as directed.
Dismantalling of existing cable and Supply, laying and testing PVC cable with copper conductor , galvanised steel strip armoured, heavy duty LT power cables, 1100 volts grade cross sectional area 70 sqmm 3 core including lux of cable complete all as specified and directed.
Dismantalling of existing cable and Supply, laying and testing PVC cable with copper conductor , galvanised steel strip armoured, heavy duty LT power cables, 1100 volts grade cross sectional area 25 sqmm 3 core including lux of cable complete all as specified and directed.
Dismantalling of existing cable and Supply, laying and testing PVC cable with copper conductor , galvanised steel strip armoured, heavy duty LT power cables, 1100 volts grade cross sectional area 16 sqmm 3 core including lux of cable complete all as specified and directed.
Dismantalling of existing cable and Supply, laying and testing PVC cable with copper conductor , galvanised steel strip armoured, heavy duty LT power cables, 1100 volts grade cross sectional area 10 sqmm 3 core including lux of cable complete all as specified and directed.
Dismantalling of existing cable and Supply, laying and testing PVC cable with copper conductor , galvanised steel strip armoured, heavy duty LT power cables, 1100 volts grade cross sectional area 50 sqmm 3 core including lux of cable complete all as specified and directed.
Carrying out test of treated water based on following parameters twice in a month and getting checked to the satisfaction of Haryana Pollution Control Board and obtaining Consent to Operation (CTO) for the period of work order : (i) pH Value (ii) TSS (iii) BOD (iv) COD (v) Coliform (vi) Faecal Coliform (vii) Dissolved Oxygen (viii) Residual Chlorine
A K BANSAL AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .