Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAdmitted-Finance | ₹27.3 L | L1 | Admitted-Finance |
| 2 | L2₹27.5 LAdmitted-Finance | ₹27.5 L | L2 | Admitted-Finance |
| 3 | L3₹27.7 LAdmitted-Finance GRAM NAVALGANJ PARADE SARKAR DISTRICT GONDA UTTAR PRADESH | GONDA | GONDA | UTTAR PRADESH | ₹27.7 L | L3 | Admitted-Finance |
Tender Value
₹27.7 L
EMD Value
₹55,500
Closing Date
13 Feb 2026, 3:00 pmClosed
EE Snk-2 Gonda
EE Snk-2 Gonda
Repair and Renovation work of Type III Building Block No. 2 and 3 Electric Wiring of Type II Block No. 1 and 6 and Residence No. III-04 and Supply Fixing of Flush Door and Painting work of Residence No. II-15 in New Saryu Nahar Colony Gonda
2026_UPIDC_1112232_2
02/EE/2025-26
Open Tender
Civil Works
Gonda
Please refer Tender documents.
3 documents required · 3 mandatory
₹854
₹55,500
Yes
19 Feb 2026
7 Feb 2026
13 Feb 2026
7 Feb 2026
13 Feb 2026
7 Feb 2026
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
Distempering (Two coat) with oil bound distemper including a priming coat with cement primer including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (Inside walls)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
12 mm cement plaster in single coat for plastering up to floor two level including internal rounded angles and finshed even and smooth. 1 cement : 6 Coarse sand (2.25FM)
Providing and fixing 1st quality ceramic glazed wall tiles in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 and including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm of 1st quality of approved make laid on 20 mm thick cement mortar 1:4, Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement
Marble stone flooring with 18 mm thick marble stone, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
Reinforced cement concrete work in shelves, chajjas, lintels,excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size
Centering and shuttering including strutting, propping etc. and removal of form for RCC work
Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make from factory/workshop to construction site including placing in position and binding all complete upto plinth level & above plinth level.
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.
Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with : 10.30.1 4.0 mm thick glass panes
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
Supply/ fixing of CPVC pipe 20mm
Vitrious china wash basin of size 550x400 mm with 15mm CP Brass single hole basin mixer
Supply/ fixing of PVC waste pipe 32mm
Supply/ fixing of C.P. jali 100mm
Supply/ fixing of Stainless Steel Angle Cock 15mm
Supply/ fixing of Stainless Steel Bib Cock 15mm
Supply/ fixing of Stainless Steel Pilar Cock 15mm
Supply/ fixing of CPVCgate valve 20mm
Supply/ fixing of CPVC pipe 75mm
Stainless steel sink with drain board 510x1040 mm bowl depth 250 mm with all fitting excluding labour
Vitrious china Indian type W.C. pan of size 580mm with 10ltr. PVC flushing cistern
Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, Modular type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash.
Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire and Modular type switch & socket etc., complete in all respects as directed, including matching color wash.
Wiring points for Call bell with 1.5 sqmm.FRLSH PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire and Modular type bell push or 2 pin socket etc. complete in all respect with Modular Box & Cover plate. etc on surface as directed including matching colour wash.
Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire,Modular type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash.
Supply & wiring of submains with two number 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.
Supply & wiring of submains with two number 4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 4.0 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 Way TPN
S/F of 63 AMP. FP MCB (10 KA)
S/F & 5Amp./6/… 32Amp. MCB 9 K.A. / 10 K.A.
Supply and fixing of two module stepped type electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.
Supply and fixing of power plug with 15A/240 V flush type switch and 6 pin 20A/10A 250 V flush type universal socket complete with GI box modular tyepe inluding supply of all material, labour T&P etc. required for proper completion of work
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Lot02.pdf
Tender Documents • 1.94 MB
BOQ_2057176.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid