Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹23.3 L+₹1.1 L (5.19%)Rejected-Finance | L2 | Rejected-Finance Highest Bid quoted | |
| 3 | L3₹24.4 L+₹2.3 L (10.3%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L3 | Rejected-Finance Highest Bid quoted | |
| 4 | L4₹28.5 L+₹6.4 L (28.7%)Rejected-Finance PLOT NO RZ B 1 59 KH NO 534 535 BLOCK B 1 NEW ROHANPURA PP NO 1416 NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L4 | Rejected-Finance Highest Bid quoted | |
| 5 | L5₹32.7 L+₹10.5 L (47.6%)Rejected-Finance | L5 | Rejected-Finance Highest Bid quoted |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
5 Sept 2022, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
SPECIAL REPAIR TO BOUNDARY WALL AND PROVN OF ADDN ALTN OF BLDG NO P 149 AT AF STATION MOHAHMADPUR UNDER GE AF GURGAON
2022_MES_544064_1
CA NO GE/GUR-/NIT-28/2022-23
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹92,000
17 Oct 2022
8 Aug 2022
7 Sept 2022
8 Aug 2022
5 Sept 2022
22 Aug 2022
Amount
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for 15mm thick Rendering on fair faces of brick work or concrete sureces in Cement Moratar 1:4 finished surface even and fair without using extra cement complete all as specified and directed.
M&L for Rough cast plaster on brick walls consisting under coat of cement and sand mortar 1:3 not less than 10mmm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed of size 6mm with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even completed all as specified & directed by Engr-in-charge.
M&L for applying two coat of cement base paint over one coat of primer using airless spray technology with max working pressure of 3300 PSI nad capable of operating single spray gun with max material lose length of 30 mtr the pray machine should be of reputed manufacturer with pro gaurd technology and capability og tracking pressure and paint usage and certified by paint ,anufacturer and as mentioned in PS and accessories for applying cemen base paint should be able to spray in hard to reach areas and penetration of distemper on the surafce complete all as specified and as directed.
M&L for complete removal of existing tratment by scrapping with meachanical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia 7''/9'' to make the surface free from dust, loose paint etc by skilled labour complete.
M&L for applying two coat of cement base paint using airless spray technology with max working pressure of 3300 PSI nad capable of operating single spray gun with max material lose length of 30 mtr the pray machine should be of reputed manufacturer with pro gaurd technology and capability og tracking pressure and paint usage and certified by paint ,anufacturer and as mentioned in PS and accessories for applying cemen base paint should be able to spray in hard to reach areas and penetration of distemper on the surafce complete all as specified and as directed.
M&L for Preparing Old Treated/Painted Steel and Iron Surfaces of any description, and applying Two Coat of Synthetic Enamel Paint (First quality) for Y shape Mild steel Angle Frame( area exc 0.25 Sqm but not exc 0.50 Sqm Each) fixed on boundary walls (Straining /Supported to barbed Wire and Concertina Coil) complete all as specified and as directed.
S & F in repair galvanised 2 strand steel barbed wire 2 mm dia barbed with 2.3 mm dia barbs at 75 to 80 mm spacing and straining, fixed to fencing post tieing at crossing with and including galvanised mild steel wire complete all as directed.
S & F hot dipped galvanised concertina razer tape coil 730mm dia, spring steel high tensile centre core wire 2.5 mm dia having 200-250gm zinc coating, 0.5 mm thick razer sheet having 90-120gm, zinc coating & min 10 mm width ( before wraping centre core wire),with GI clip 1.6 mm thick complete all as specified and directed.
Excavation in trenches n.exc 1.50mtr wide and 1.50mtr in depth for foundation etc or for shafts, wells cessipts, manhole etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr deth and getting out in soft /loose soil etc complete all as specified and as directed.
Removing excavated soil/ building material/debries to a distance exc 250 mtr but not exceeding 500 mtr and depositing where directed etc complete all as specified and directed.
Returning filling in, with soil inlcuidng spreading, levelling, watering and well ramming in layers not exc 25 cm thicks etc complete all as specified and as directed.
M&L for cement concrete 1:2:4 typeB-2 (using 40mm graded aggregates) as in foundation and mass concrete etc complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and as directed.
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in CM 1:4 etc complete all as specified and directed.
M&L for 15mm thick Rendering on fair faces of brick work or concrete sureces in Cement Mortar 1:6 finished surface even and smooth without using extra cement complete all as specified and as directed. Note the area includs in this up to 4th stories building.
M&L for Steel Window Box type using ERW ‘P’ Section comprising Double Frame for Gauged and Glazed Skeleton Shutter jointed internally with Flat Iron 40x3mm complete including Mild Steel Tower Bolts, Hinges, Handle, Stops, Lugs including GI Steel Wire Cloth, Glazing, etc. all as directed. Outer Section of Frame should be 50x25mm and Inner Section should be 40x20mm, complete all as specified and as directed. NOTE :- (a) For the purpose of Measurement & Payment Double Shutter with Frame shall be considered as One Unit. (b) Cost of Iron Mongery as ordered/required at Site, GI Steel Wire Cloth will deem to be included in the Quoted Unit Rate. (c) Guard Bars are included in the Quoted Unit Rate. Spacing of 10mm Square Bar will be 10 Cm Centre to Centre. (d) Glazing shall be Measured and Paid separately under appropriate Item.
S & F in repairs 125x60mm size Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinge, lock strike plate, etc. complete all as specified and as directed.
S&F 100mm Butt hinges, meduim weight, cold relled stainless steel and fixed complete all as specified and as directed.
S & F for aluminium anodised, barrel tower bolts of extruded section 125mm long and fixed complete all as specified and as directed.
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F 30 mm thich 2nd class Hard wood Glazed and skelton shutters, open rebated and prepared to receive glass, guaze etc, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securiing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(a) and fitted to chowkats complete all as specified and as directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side complete all as specified and as directed.
S&F for Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of exctruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
S & F for mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
M&L for chequered cement concrete tiles 20cmx20cm x 25mm thick, With grey cement and pigments, set, jointed and pointed in neat cement slurry ,over and including 20 mm thick screed bed or bedding layer of cement mortar 1:6, over new or existing sub-base in floors complete all as specified and as directed.
M&L for 25mm thick Cement concrete 1:2:4 type B-O(using 12.5mm graded aggregate) as in flooring, finished surfaces even and smooth without using extra cement complete all as specified and as directed.
S&F stain less steel decorative cutrain rod of 25 mm bore inluding 2 nos steel finale and bracket 02 nos etc and fixed to wall with plastic rowl plug and steel screw complete all as specified and as directed.
M&L for prepepring the entire surface with appliying 2-3 mm thick putty on wall surface internal surface finished even and smooth complete all as specified and as directed.
M & L for new plaster surface applying two coat Oil Bound distember on wall surface with roller brush complete all as specified and as directed.
M&L for preparing new wooden surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over pink primer complete all as specified and as directed.
M&L for preparing new steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enemal paint complete all as specified and as directed.
M&L for Vitrified ceramic light shade tiles, 10 mm thick (square/ rectangular) polished ,area of each tile not exc. 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and as directed.
M&L in repair for sub main wiring for circuit of size 4 sq mm 2 run (FRLS) alongwith earth wire of 2.5 sq mm single run of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in new/existing PVC conduit (surface/conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. (Conduit and its accessories shall be measured and paid separately under respective item).
M&L in repair for sub main wiring for circuit of size 1.5 sq mm 2 run (FRLS) alongwith earth wire of 1.0 sq mm single run of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in new/existing PVC conduit (surface/conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. (Conduit and its accessories shall be measured and paid separately under respective item).
M&L in repair for sub main wiring for circuit of size 2.5 sq mm 2 core (FRLS) alongwith earth wire of 1.5 sq mm single run of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in new/existing PVC conduit (surface/conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. (Conduit and its accessories shall be measured and paid separately under respective item).
S&F rigid non-metalic PVC conduit 20mm (external dia) ISI marked (on surface) including of all accessories and all fittings such as Tees, bends, elbows, reducers, bell mounth, tube ends, and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete all as specified and directed by Engr-in-Charge.
S&F modular switch 1 way 6 Amp with modular metal box & modular cover plate with frame complete all as specified and directed by Engr-in-Charge.
S&F modular socket 6 Amp, 2/3 pin combined 2 module complete all as specified and directed by Engr-in-Charge.
S&F modular socket 2 in 1, 3 pin, 6/16 Amp, with modular metal box & modular cover plate with frame complete all as specified and directed by Engr-in-Charge.
S&F modular switch 1 way 16 Amp complete all as specified and directed by Engr-in-Charge.
Supply and fix of ceiling fan 1200 mm sweep complete with down rod canopy and blades of size 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, Energy efficient, 5 star rated with brushles direct current motor (BLDC) complete all as specified and as directed. Make Havells/Crompton / Bajaj.
Supply and fix of air circulator wall mounted fans 230 volts singl phase oscillating 450mm sweep suitable for wall mounting complete all as specified and as directed. Note: Appropriate nuts, bolts for fixing of wall mounted fan shall be deemed to be included by rate quoted by contractor.
S & F modular white cover plate with frame and modular metal flush box 6 way complete all as specified and directed.
SHAKSHI ENTERPRISES
akhil enterprises
M/S CHANDER MUNI
Parveen Builders
VINAYAKA (INDIA) MULTIFARIOUS SERVICES PVT LTD
Goyal Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .