Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr Quoted ₹2.0 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.0 Cr+₹1.7 L (0.90%)Rejected-Finance FLAT NO 201 GF KAMAL VIHAR CGHS LTD PLOT NO 5 SECTOR 7 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹2.0 Cr+₹1.7 L (0.90%) | L2 | Rejected-Finance L2 |
| 3 | L3₹2.0 Cr+₹4.4 L (2.26%)Rejected-Finance | ₹2.0 Cr+₹4.4 L (2.26%) | L3 | Rejected-Finance L3 |
| 4 | L4₹2.0 Cr+₹4.8 L (2.47%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹2.0 Cr+₹4.8 L (2.47%) | L4 | Rejected-Finance L4 |
| 5 | L5₹2.0 Cr+₹9.6 L (4.92%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹2.0 Cr+₹9.6 L (4.92%) | L5 | Rejected-Finance L5 |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
25 Sept 2023, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
Provision of Package Type AC Plant at 172 MH under GE Gurdaspur
2023_MES_584325_2
81044/E8
Open Tender
Civil Works
Item Rate
365 days
Jalandhar Cantt
AS Per NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer Gurdaspur
₹2.9 L
Yes
10 Nov 2023
5 Sept 2023
30 Sept 2023
5 Sept 2023
25 Sept 2023
13 Sept 2023
Amount
Note: Please refer Schedule 'A' Notes given on serial page No. 22 to 24 of tender documents.
AIR CONDITIONING AND REFRIGERATION INCLUDING BUILDING WORKS
Design, Supply, Installation Testing and Commissioning of Variable Refrigerant Flow type multi unit air-conditioning system suitable for year round air- conditioning to maintain inside condition DBT 22 ± 4 Degree C and RH (50 ± 10) % for outside conditions of Gurdaspur Mil Stn as per IMD record .The units shall be of Heat Pump Type , air cooled, factory fabricated and factory assembled and shall be capable of providing both cooling/ heating complete with indoor and outdoor units etc as per specification given here under :- OUTDOOR UNIT Supply, Installation Testing and Commissioning of outdoor units including vacumising , Gas charging of Modular type units having actual capacity at 43 Degree C outside temp and providing non stop cooling upto 56 DegreeC .Outdoor units shall comprise of highly efficient scroll compressors, with all Inverter Scroll type compressor(s), heat exchanger, low noise condenser fan, auto check function for connection error etc, centralize controller for individual control as per OEM specifications of following capacities as under :- Note - 1. The Minimum COP at AHRI conditions shall be 3.4 at 100% load 2. The ODUs shall be capable of operating upto 56 deg C. 3. Leakage test for copper pipe will be done by contractor after installation. 4. Pressure testing & charging of refrigerant R 410 gas of complete AC system will be performed as required at site 5. ODU above 28 HP will be assembled by either two or three different ODUs.
As per srl item No 2.00 of capacity 36 HP comprising of 1XODU of 24 HP Model IVRFB-24 THN and 1XODU of 12 HP Model IVRFB-12THN of Blue star or equivelent model of Voltas / Carrier / Daikin. Note:- 1 Set of ODU will be installed at Medical Ward and 1 set of ODU at Surgical Ward.
As per srl item No. 2.00 of capacity 28 HP ,Model IVRFB-28THN of Blue star or equivelent model of M/S Voltas or M/S Carrier or M/S Daikin. Note:- 1 Set of ODU will be installed at OPD Area and 1 set of ODU at Family Ward.
As per srl item No. 2.00 of capacity 26 HP, Model IVRFB-26THN of Blue star or equivelent model of M/S Voltas or M/S Carrier or M/S Daikin. Note:- 1 Set of ODU will be installed at ICU Ward.
As per srl item No. 2.00 of capacity 24 HP, Model IVRFB-24THN of Blue star or equivelent model of Voltas / Carrier / Daikin. Note:- 1 Set of ODU will be installed at Trauma Center and 1 set of ODU at OT Complex.
INDOOR UNIT Supply , Installation testing and commissioning of Indoor Units either ceiling mounted cassette type, High wall unit as specified and directed. The indoor unit shall have independent electronic control valve to control the refrigerant flow rate corrospond to variations of the air-conditioning load of the room. The fan shall be aerodynamically designed turbo , multiblade type. Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for min 21 Kg/cm2. Indoor units shall have a cordless remote control. They shall be operated through from the cordless remote control from the respective rooms for capacities as under.
As per srl item No. 2.05 of capacity 0.8 TR Hi Wall , Model VHW-10B of Blue Star or equivalent model of M/S Voltas,M/S carrier,M/S Daikin. Note: 1Nos X Patients waiting Hall , 1Nos X Treatment Room.
As per srl item No. 2.05 of capacity 1.0 TR Hi Wall , Model VHW-12B of Blue Star or equivalent model of M/S Voltas,M/S carrier,M/S Daikin. Note : 1 NosX Officers waiting Room, 1NosX MD I/C Room III, 1Nos X Offrs Surg Wd, 1 NosX Acute Med Ward.
As per srl item No. 2.05 of capacity 1.3 TR Hi Wall, Model VHW-16B of Blue Star or equivalent model of M/S Voltas,M/S carrier,M/S Daikin. Note: 1 Each X (OPD1,OPD2, Varandha, Duty Room, Waiting Area,Treatment Room of ICU ward, Duty Room(Surgical ward),OIC Room.
As per srl item No. 2.05 of capacity 1.5 TR Hi Wall , Model VHW-18B of Blue Star or equivalent model of M/S Voltas, M/S carrier, M/S Daikin. Note : 1 Each X ( MO i/c Room II, DMO Room, MO I/C Room-I, Pre ops Room, Varandha, Pre OP Room)
As per srl item No. 2.05 of capacity 1.7 TR Hi Wall , Model VHW-20B of Blue Star or equivalent model of M/S Voltas, M/S carrier,M/S Daikin. Note : 1 Each X ( OPD 4, Nursing station, fam Med Wd, Offr Fam Med-I, Acute surg cabin-I, Acute surg cabin-II)
As per srl item No. 2.05 of capacity 2.0 TR Hi Wall , Model VHW-24B of Blue Star or equivalent model of M/S Voltas, M/S carrier,M/S Daikin. Note: 2NosX(Maty Wd) and 1 Each X ( Treatment Room in OPD , OPD 3, Labour Room-I, Labour Room-II,Treatment Room, Acute Med Wd, Dressing Room , Treatment Room for Surgical wd, Minnor OT)
As per srl item No. 2.05 of capacity 2.5 TR Hi Wall , Model VHW-30 of Blue Star or equivalent model of M/S Voltas,M/S carrier,M/S Daikin. Note: 1 EachX (OPD-5,Offrs waiting area, Fam surg wd,Post OP Room, Acute Med Ward-02 Nos, Acute Med Ward for ICU, Post operative Ward,Acute Med Ward for Surgical Ward-02 Nos)
As per srl item No. 2.05 of capacity 2.0 TR Cassette unit , Model VCL-24 of Blue Star or equivalent model of M/S Voltas,M/S carrier,M/S Daikin. Note: 2 NosX ICU-II
As per srl item No. 2.05 of capacity 2.3 TR Cassette unit, Model VLC-27 of Blue Star or equivalent model of M/S Voltas, M/S carrier, M/S Daikin. Note: 3Nos Each X (Trauma Centre and Paitents Waiting Room)
As per item No. 2.05 of capacity 2.8 TR Cassette unit , Model VLC-34 of Blue Star or equivalent model of M/S Voltas,M/S carrier,M/S Daikin. Note: 2 each x Accident and Emergency Room
As per item no 2.05 of capacity 3.2 TR Cassette unit , Model VLC-38 of Blue Star or equivalent model of M/S Voltas,M/S carrier,M/S Daikin. Note: 4 EachX (Medical I Ward and Surgical I ward) and 2 X ( ICU I Ward).
(v) The rate quoted for indoor units is deemed to be inclusive of making cut in wall, inserting PVC sleeve and making good the disturbed surfaces to match with adjoining surfaces as per standard Engineering practice recommended by OEM. (vi) The contractor shall conduct Nitrogen test and vacuum test on refrigerant piping minimum for 02 days before commissioning. Start and stop timing & pressure maintained shall be checked and the readings recorded shall be counter signed by Engineer- in- Charge. The unit rate quoted is deemed to be inclusive of these tests. (vii) The contractor shall submit computer generated reports of the VRF system for a duration of 24 hour indicating pressures, temperatures, voltage, power consumed, etc complete all as specified & directed by Engineer-in-Charge. (viii) The contractor shall submit 03 sets of the wiring diagram, final layout of indoor and outdoor units, technical Litrature, OP & maint sch, Trouble shooting chart.
Supply of Cordless Remote units for Hi Walls Unit and Cassette unit complete all as specified and directed
Design, Supply, installation, testing and commissioning of double skin floor mounted Cabinet type, Two Stage Filter Air handling unit of 2400 CFM, complete with specifications and capacities as under :- (a) Panel Construction and Casing. (b) Frame: Extruded Aluminum Hollow Profile, the profile box shall be of minimum 48 ± 2 mm, Frame should be assembled using glass fiber reinforced nylon joints/ corner. (c) Panel: Panel shall be double construction ,PUF insulation having density 40 ± 2 Kg/M3. factory injected by injection moulding machine. (d) Outer skin-----0.6 mm powder coated with min 50 micron thickness. (e) Inner skin ----0.6 mm powder coated with min 50 micron thickness. (f) AHU shall have Water Tight Positive Pressure access/ service door duly interlocked with fan. AHU shall have Thermally insulated totally sealed glass inspection window. Door shall be hinged type, hinged shall be casted powder coated zinc alloy. Flush Lock and Handle shall be of glass fiber reinforced polyamide . Inspection lamp with limit switch. (g) Base Frame : Base frame ZHK Indu. GR-LP80 galvanized steel. (h) Mixing Box Section : Mixing box shall have fresh air, return air damper. The dampers shall be low leakage Aerofoil design and in Aluminum Construction. Fresh air spigot shall be suitable for 500 FPM velocity, return air spigot shall be suitable for min 500 FPM velocity. (j) Filter Section : Filter section with 50 mm thick box type pre- filter (MERV-8) & 305 mm thick bag type fine filter( MERV-12 ) mounted on a common filter frame , discharge plenum with 305 mm thick HEPA filter (MERV-17) . Pre filters having efficiency 90 % down to 10 micron and fine filters having efficiency 95 % down to 5 micron. Filter face velocity as min 500 FPM however velocity across media shall be 350 FPM. Make : Mechmaark/ Spectrum/ American Airfilters. (k) COIL SECTION :-The cooling coil shall have 6 Rows Deep having suitable coil face area, copper tubes thickness 0.3 mm , outer tube dia 9.5 mm in GI coil casing .Drain Pan material shall be SS-304 and drain Pan thickness 22 gauge duly insulated 13 mm thick close cell Nitrile Rubber insulation material for Drain Tray. No of Aluminum Fins per Sq. inch : 12 to 13 having thickness of 0.15mm (Note : Coil should be AHRI Certified).
(l) Heater Section : Heater Section with heater arranged in banks of cap 1 KWX3 Nos (2 Banks) for Monsoon reheating complete with Gyserstat , power and control wiring inclusive of all above for automatic temp and humidity control. (i) All heaters shall be manufactured out of S.S. 316L sheathed tube for higher temperature upto 600 C. Each heating element is made of NiCr 80/20 resistance wires. (ii) Each element shall be provided with two adjustable fixing arrangements. Tube diameter shall varies from 8.0mm to 15mm. (iii) Fins of S.S. shall be provided to enlarge the heat surface. (iv) Supply Voltage shall varies from 110V to 240V AC/1PH/50Hz.
(m) FAN SECTION : Fan section with DIDW centrifugal backward curved ,fan type BC and Dia 280 mm, Fan efficiency 74.5 %, noise level@1 m distance 74.4 dBA , max fan out velocity- 8.70 m/s , RPM 3147 ,TEFC drive squirral cage motors (IE2 efficiency) , motor rating 2.2 KW ,suitable for 415 + 10% volts, 50 Hz, 3 phase AC supply. Fans should be AMCA/ EuroVent certified for Air & sound performance. (n) Fan shall be dynamically trim (Two stage) balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade after assembly. (o) Fan Impeller should be made of Cold Rolled sheet steel polyester powder coating, Fan Inlet Cone must be Spurn GSS having GSM 220, zero sprangle . (p) Impeller should be directly coupled on Motor shaft to avoid any maintenance & to save drive transmission losses. (q) Fan assembly should be mounted on Cushy foot mounted Vibration isolator. Make of Cushy foot mountains : Kruger/ Vibrosolve. (r) Fan performance curve should be of Single RPM curve. It should not be multi RPM curve. Make of Fan : Nicotra/Kruger/Greenheck & Make of Motor : Siemens/Bharat Bijlee/Havells. (s) AHU manufacturer should not fabricate Fan motor structure etc at their manufacturing unit and they should supply entire assembly from fan manufaturer. (t) Provision for Pan Humidifier : Provision for Pan Humidifier (only space for pipe insertion and necessary accessories/ fitting reqd for making the AHU airtight. Pan humidifier will be mounted outside the unit as per BOQ Item srl No. 2.19) Make of AHU ;- Edgetech/M/s System Air/Citizen/Zeco Bahadurgarh. Note : The scope of AHU shall also include following:- (a) UVGI lamps (UL Certified) - UVC emitter (Each AHU will have combination of 2 feet long UVC lamps, each lamp shall cover effectively 4sqft of area ) in coil section of AHU. The scope shall include electrical wiring and electrical isolator for following capacities. The purpose of these UVC emitters is to improve indoor air quality (IAQ) by eliminating mould, bacteria and other contaminants in down stream section.
(b) AHU's shall be mounted on P.C.C. blocks with neoprene pads in between. (c) Set of each Temperature & water pressure guage (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) for coils. COIL UNIT : Edgetech/M/s system Air/Citizen/Zeco Bahadurgarh or as per OEM of AHU
Supply and installation of Pan type Humidifier of cap 6 KW each for OTs AHU for humidification made from stainless steel 304 sheet in welded construction, inlet, drain and steam outlet nozzle, 25 mm thick fibre glass wool (150 Crown) and cladded with 22 Gauge GI Sheet . Controls comprising of low level switch float valve with SS ball, site glass, high temp cut out thermostat, digital humidistate with necessary wiring with copper bus bar connector. Note : One set for OT1 AHU & another for OT2 AHU. Make: Honeywell/Siemens/Rapid Cool.
Supply and Installation of AHU kit complete with remote as specified. Model: VAEKIT-065 and Expansion valve and Drier as per OEM recommendation for automatic control of temp & RH in OT1 & OT2 including reqd no of air sensor with suitable mounting arrangement & necessary safety protection, interlocking with heat pump as per OEM recommandation. Note : Cost for control cable for interconncetion are deemed to be included in scope of work as per manufacturer instructions.
Supply, installation, testing/ commissioning of cubical compartment type wall mounted electrical control Panel for AHU starter, strip heaters banks and Pan Humidifier as per OEM recommendation complete all as specified and directed.
Suppy and installation of laminar flow (LAF) system direct flow from ceiling to floor. The flow passing over head and upper body of surgeon and assistant made out of aluminium powder coated made of 16SWG, particle size retention of 0.3 mm , plenum size 8'x6' complete with Hepa filters of size 610 x610 x 305 mm and SS perforated grilles having minimum 50% perfortation entry of air to housing shall be from side center of plenum shall be blanked off for lightening provisions.make:- Thermadynl/Avonaire or Equivalent
Design , supply, installation, testing, balancing and commissioning of supply air ducting and return air ducting system for OT 1 and OT 2 made of factory GSS sheet of thickness 24 Gauge confirming to IS: 277 with Zinc coating of not less than 120 grade, site fabricated as per SMACNA-1995 standard and as per IS:655 , complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Make: Sail/Tata/Jindal. (a) 20 gauge galvanized sheet steel
All as per srl item No. 2.23 but 22 gauge galvanized sheet steel
All as per srl item No. 2.23 but 24 gauge galvanized sheet steel
Supply, installation, testing and commissioning of closed cell Nitrile rubber insulation of density min 40 kg/m3 with Factory laminated G.C Cloth of 13mm thickness applied with Proper adhesive and sealed with 75 mm wide BOPP Tape on all longitudinal/transverse joints on ducts complete as per specifications. Make Kflex/armaflex
Supply and Application of internal acoustic lining of 10 mm thick over supply air ducting using open cell nitrile rubber insulation with density within min 40 Kg/m3 as per the approved shop drawings and specifications. Insulation material shall be bonded with the ducts using metal screw and washers to facilitate grip to the GI sheet. Make :Kflex/armaflex
Supplying & fixing of opposed blade aluminum construction volume control dampers adjustable in duct collars as per approved drawings and specifications. Make Systemaire /caryaire /Trox.
Supply and fixing of opposed blade aluminium contruction low leakage volume control dampers adjustable in duct as per approved drawings and as per approved specification complete with OBSS damper complete all as specified and directed.
Supplying & fixing of opposed blade aluminium construction fire dampers adjustable in duct as per approved drawings and as per approved specification.
Providing and fixing Fire retardant non porous double layer flexible canvass connection between each indoor unit and duct as per approved drawings and specifications.
Supply, Installation, testing and commissioning of Interconnecting refrigerant copper pipe ,fitting like elbow ,couplers ,tee , joints, brass fitting,"U" loops etc work with (19 mm / 13mm thick) closed cell elastomeric nitrile rubber tubular insulation with glass cloth between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger and all external piping shall run in covered cable tray and the exposed piping should be insulated with factory backed glass cloth for mechanical and UV protection as per specifications and as Engrs practice. (a) 34.9 mm dia with 19mm thick insulation
All as per srl item No. 2.32 but 28.6 mm dia with 19mm thick insulation
All as per srl item No. 2.32 but 22.2 mm dia with 19mm thick insulation
All as per srl item No. 2.32 but 19.1 mm dia with 13mm thick insulation
All as per srl item No. 2.32 but 15.9 mm dia with 13mm thick insulation
All as per srl item No. 2.32 but 12.7 mm dia with 13mm thick insulation
All as per srl item No. 2.32 but 9.5 mm dia with 13mm thick insulation
All as per srl item No. 2.32 but 6.4 mm dia with 13mm thick insulation
Supply, installation, testing and commissioning of Imported fittings Y- joints for jointing two outdoor units etc as per specifications and as per OEM recommendation. Note:- Two no for 2 x (24HP + 12HP) ODUs for medical ward, surgical ward and One no for OT complex 1X(12HP + 12HP).
Supply, installation, testing and commissioning of Imported fittings (Ref Net) Y- joints for Indoor units etc as per specifications and as directed.
Supply, Installation, testing and commissioning of 40mm dia UPVC piping (IS No-13592) complete with fittings, supports complete as per specifications and as directed.
All as per srl item No. 2.42 but 32 mm dia complete all as specified and directed.
All as per srl item No. 2.42 but 25 mm dia complete all as specified and directed.
Supplying and installing size of 50mm x 300mm x 50mm of thickness 1.6mm of perforated painted with powder coating M.S cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ wall with M.S suspenders including bolts & nuts, painting suspenders etc as reqd complete all as spcecified and directed.
Supplying and fixing control cum transmission wiring of 2 core x 0.75 sq. mm. copper sheathed in PVC concealed conduits inclusive of all tees, bends, elbows, reducers and accessories including cutting chases for conduits and making good wall, floor etc between indoor and outdoor unit complete all as specified and directed.
Supply and laying/ fixing of following size XLPE insulated and PVC sheathed Copper conductor unarmoured cable as required of 1.1 KV grade complete as required (ISI Marked) (in ground/in pipe/ in duct/ on surface/ on cable tray) (a) 3 core x 2.5 sqmm, conforming to IS No 694-1990 complete all as specified and directed.(For AHU Motor)
All as per srl item No. 2.47 but 3.5 core x 2.5 sqmm, conforming to IS No 694-1990 complete all as specified and directed.(For Strip Heaters).
All as per srl item No. 2.47 but 6 core x 1.5 sqmm, conforming to IS No 694-1990 complete all as specified and directed.( For Control Wiring).
All as per srl item No. 2.47 but 3.5 core x 4 sqmm, conforming to IS No 694-1990 complete all as specified and directed.(For Pan Humidifier).
Material and labour for cement concrete type C-1 (1:3:6) (using 20mm graded aggregate) as in plinth protection, 70mm thick including making good the distrubed area complete all as specified and directed.
Material and labour for brick work using sub class 'B' bricks, strainght or curved on plain exc. 6 mean radius in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
Material and labour for brick work (except bricks) using sub class 'B' bricks, strainght or curved on plain exc. 6 mean radius in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. Note : Bricks shall be used i.e. obtained from demolition of Item Sl No 2.60 of BOQ)
Material and labour for 15mm thick cement plaster in cement mortar 1:4 on fair faces of brick work and finishing the surface even and smooth (without using extra cement) including using with water proofing compound and complete all as specified and directed. Note: WPC shall be measured and paid separetly.
Material and labour for 15mm thick cement plaster in cement mortar 1:6 on brick work or concrete surfaces other than fair faces and finishing the surface even and smooth (without using extra cement) including complete all as specified and direct
Material and labour for preparation of newly platered surface/ un plastered of wall and applying two coats of cement base paint of shade as approved over a coat of cement primer complete all as specified and directed.
Material and labour for preparation of newly platered surface/ un plastered of wall and applying two coats of oil bound distemper (of approved shade) over a coat of chalk whiting primer and complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Supply and fixing perforated particle boards or tiles 12mm thick for insulation and acoustic purpose, 60 cm x 60 cm in size fixed with staple on snap grid in ceiling complete all as specified and directed.
Demolition of brick work built in cement mortar or cement lime mortar as cutting, opening of existing wall complete all as specified directed.
Material and labour for providing and fixing 12mm thick seamless calcium silicate ceiling made out of 1800 x 1200mm size board of siliceous material reinforced with cellulose fibre fixed to the ceiling section with 25mm long self-drilling and tapping screws having Phillips head with under head cutter t 200mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seam less finish (Framework for ceiling shall be measured and paid separately) complete all as specified and directed
Material and labour for providing two coats OBD over and including 2mm thick putty to make surface even and smooth on ceiling complete all as specified and directed
Dismantling of wall/ ceiling board any thickness, including all necessary fittings, fillets/ grid complete all as specified and directed
Material and labour for providing and fixing 4 GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 24mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx. 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with clips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed
EXTERNAL ELECTRIFICATION WORKS
Supply, install, testing and commissioning of AC 3 phase 50 HZ all as per IS : 1180 Part II 2014 with latest amendment no.4 March 2021 with maximum total loss (w) as Energy Efficiency Level 2 and BEE certified of capacity 315 KVA capacity transformer step down, outdoor type 11000/433 volts (at no load) copper wound, oil immersed, ONAN cooled with external cooling tubes/ fins, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of 2.5 % from (+) 7.5% to (-) 7.5% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage ons econdary side including provision of all necessary / standard fittings and first fill of oil, mainly comprising of following :- (i) One cable box on primary H.V side with brass/ gun metal bushing rods complete with nuts and washers) cable gland suitable for reception of outgoing armoured cable. (ii) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings cable gland suitable for reception of two nos outgoing armoured cable. (iii) Oil conservator with filter type, drain valve and oil level gauge. (iv) Transparent Dehydrating breather with first fill of dry silica gel. (v) Explosion vents with diaphram. (vi) Temperature guage on tank cover having range 0-200 degree centigrade. (vii) Rating plate with terminal markings. (viii) Two earthing terminals on tank/tank cover to facilitate fixing of 32 x 6 m earth strip. (ix) Oil drain and filter valves.
(x) Oil filler hole with cap/plug complete. (xi) Lifting lugs. (xi) AIr relief valve plug. (xii) Four solid cast steel detachable rollers. (xiii) First fill of fresh oil conforming to relvant IS and tested upto 50 kV dielectric strength. (xiv) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral. (xv) Two Nos danger boards 250 x 200 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters). figures of voltage and conventional skull and bones in signal red colour , one at H.T side and other on L.T side.
Supply Install , testing and commissioning of LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extersion links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. The cubicle shall have frame work, at bottom of MS channel MC100 fixed to the top of platform. The platform of LT Panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class'B') work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-Charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the botom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following . Note:- (i) LT Panel board should be CPRI approved as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining aproval from GE). (ii) SLD diagram for LT Panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (iii) Rate for the same deemed to include in the quoted rates. (for Main LT Panel).
Incomer:- (a) MCCB 4 Pole, 35 KA, 415 V, with Thermal Magnetic Release of capacity 500 Amps - 01 No. Make as specified in Appendix B-1. (b) Busbar TPN , Aluminum 800 Amps - 01 Set (c) Digital type multi function meter to measures V,A,F,PF with suitable CT's - 01 Set (d) LED indicator - 01 Set (RYB) Outgoing:- (a) MCCB 4 Pole, 35 KA, 415 V, with Thermal Magnetic Release of capacity 250 Amps - 01No. Make as specified in Appendix B-1. (b) MCCB 4 Pole, 35 KA, 415 V, with Thermal Magnetic Release of capacity 200 Amps - 03 No. Make as specified in Appendix B-1.
Supply Install, testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extersion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. The cubicle shall have frame work, at bottom of MS channel MC100 fixed to the top of platform. The platform of LT Panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class'B') work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-Charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate with letter , figures and conventional skull bones in signal red colour and fixed front & back dor to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following . Note:-(i) LT Panel board should be CPRI approved as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining aproval from GE). (ii) SLD diagram for LT Panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (iii) Rate for the same deemed to include in the quoted rates. (LT Panel for (Medical Ward, Family Ward) and (Surgical Ward, ICU Ward) Incomer:- (a) MCCB 4 Pole, 35 KA, 415 V, with Thermal Magnetic Release of capacity 160 Amps - 01 No. (b) Aluminium busbar 300 Amps for 3 phase & neutral - 1 Set (c) LED indicator - 01 Set (RYB) Outgoing:- (a) 63 Amp 4 pole 16 KA MCCB with adjustable thermal & Adjustable magnetic release -03 Nos (b) 80 Amp 4 pole 16 KA MCCB with adjustable thermal & Adjustable magnetic release -01 Nos.
Supply Install , testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC support . The incoming as well as outgoing MCCBs shall have extersion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. The cubicle shall have frame work,at bottom of MS channel MC100 fixed to the top of platform. The platform of LT Panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class'B') work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-Charge . A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate with letter , figures and conventional skull bones in signal red colour and fixed front & back dor to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following . Note:- (i) LT Panel board should be CPRI approved as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining aproval from GE). (ii) SLD diagram for LT Panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (iii) Rate for the same deemed to include in the quoted rates. ( LT Panel for OT Complex). Incomer:- (a) MCCB 4 Pole, 35 KA, 415 V, with Thermal Magnetic Release of capacity 160 Amps - 01 No. (b) Aluminium busbar 300 Amps for 3 phase & neutral - 1 Set (c) LED indicator - 01 Set (RYB) Outgoing:- (a) 63 Amp 4 pole 16 KA MCCB with adjustable thermal & Adjustable magnetic release -04 Nos (b) 80 Amp 4 pole 16 KA MCCB with adjustable thermal & Adjustable magnetic release -01 Nos.
Supply Install, testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC support . The incoming as well as outgoing MCCBs shall have extersion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall colour coated sleeves. The cubicle shall have frame work, at bottom of MS channel MC100 fixed to the top of platform. The platform of LT Panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class'B') work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-Charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following . Note:- (i) LT Panel board should be CPRI approved as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining aproval from GE). (ii) SLD diagram for LT Panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (iii) Rate for the same deemed to include in the quoted rates. ( LT Panel for Trumma Centre and OPD) Incomer:- (a) MCCB 4 Pole, 35 KA, 415 V, with Thermal Magnetic Release of capacity 160 Amps - 01 No. (b) Aluminium busbar 300 Amps for 3 phase & neutral - 1 Set (c) LED indicator - 01 Set (RYB) Outgoing:- (a) 63 Amp 4 pole 16 KA MCCB with adjustable thermal & Adjustable magnetic release -02 Nos (b) 80 Amp 4 pole 16 KA MCCB with adjustable thermal & Adjustable magnetic release -02 Nos. (c) MCB 63 Amp 4 Pole 16 KA- 02 Nos
Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I)
Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I). Notes for srl Item No. 3.06 & 3.07. (a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made. (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (c) If the testing result of earthing work is not found satisfactory then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account. (d) Earthing work will be carried out in presence of MES representative.
Supply and fixing earth continuity conductor or main earthing lead, fixed to wall on batten or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor (Earthed) grade, cross sectional area 95 Sqmm 3 core complete all as specified and directed.
Supply and lay XLPE insulated bedded galvanised steel strip or wire armound electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor 185 sqmm 3.5 core complete all as specified and directed.
All as per srl item No. 3.10 but 150 sqmm 3.5 core complete all as specified and directed.
All as per srl item No. 3.10 but 400 sqmm 3.5 core complete all as specified and directed.
All as per srl item No. 3.10 but 16 sqmm 4 core complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade for outdoor termination cold shink type joint complete with jointing material and accessories suitable for 3 core XLPE armound AI conductor cable of size 95 Sqmm complete all as specified and directed.
Supply and install HT 11 KV outdoor type gang operated air switch (GOD) suitabe for horizontal or vertical mounting fixed type complete with 12 insulators of rating upto 200 Amp complete all as specified and directed.
Material and labour for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.00 metres long) complete all as specified and directed.
Material and labour for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
Material and labour for cross arms in replacement, bracing, supports, clamps and brick plates, fabricated from structural steel section including nut bolts washers including welding bending , cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide complete all as specified and directed.
Material and labour for plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling mass concrete and around the poles including necessary formwork and finishing the exposed surface even & smooth without using extra cement complete all as specified.
Material and labour for PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregat)e as in foundation of stay incl necessary formwork complete all as specified and directed.
Material and labour PCC 1:2:4, type B-2 using 40 mm graded stone aggregate as in foundation filling, mass concrete complete all as specified.
Material and labour for lightening arrestor expulsion type for out door use complete with all fitting station class discharge capacity 65 KA suitable for 11000 volts including bracket, clamps, nuts, bolts washer and connection to each wire complete all as specified. Make-Rashtria/Oblum.
Supply and laying un-reinforced precast conncrete cable cover, class HV, type I, flat, size 300 mm x 180 mm x 40 mm laid flat in trenches over the cable with the length of cable cover perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-Charge.
Sand cushioning trenches using fine sand to under ground cable, laid in two layers 8cm before laying the cable & 15cm after laying the cable complete all as specified.
Supply and laying brick common burnt sub class 'B' old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable complete all as specified and directed.
Supply and laying GI pipe of light grade 80 mm for cable protection complete all as specified and directed.
Supply and fixing sheet metal enclosures for DB's ( Double door type) when MCB's to be used, single pole and neutral, 8 way with 200 amp rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection complete all as specified and directed.
Supply and fixing MCB double pole , 240 volts , upto 32 amp, rupturing capacity 10 KA, 'B' curve type complete all as specified and directed.
Supply and fixing MCB single pole , 240 volts , 6 to 32 amp, rupturing capacity 10 KA, 'B' curve type complete all as specified and directed.
Supply and fixing MCB dummy plate complete all as specified and directed.
Material and labur for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonary for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.
Material and labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 2.5 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonary for fixing conduit and making good the disturb surfaces of wall as per existing including 2.5 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.
Supply and laying PVC insulated multicore stranded copper multiflexible round cable 1100 volt grade with copper conductor 10 sqmm 4 core , conforming to IS No 694-1990 complete all as specified and directed.
Material and labour for distribution board made out of CRCA sheet DB vertical type double door TPN 4 way including fixing in the wall , cutting chases grounting and making good to match with the existing including making connections all as directed containing the following :- (a) MCCB 4 pole 63 Amps 16 KA breaking capacity with the thermal release 01 No (Incoming ) will be made with Aluminium strip of suitable capacity as directed.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 10 amp , 240 volt complete all as specified and directed.
DG SET WORKS
Supply, installation, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB II condition/norms, 160 KVA (128 KW) rating as per BS-5514, 06 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM, 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank of suitable capacity(minimum 12 hrs capacity of consumption) & including all excavation PCC foundation, anti-vibration pads/ dampers including standard control panel other accessories as per manufacturer's design. The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level. The acoustic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt Notification. Specifications of DG set shall be as specified and comprising of the following:- (A) ENGINE (Prime mover) : Diesel engine vertical type of adequate capacity for 160 KVA (128 KW), 06 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM under NTP conditions of BS : 5514, turbo charged water cooled, compression ratio 16:5:1, 12 volts 180 Ah electric battery start, complete with fly wheel and all standard fittings/fixtures as per manufacturer instructions including suitable engine control panel/dash Board with electronic tachometer. Lubrication oil temperature & pressure gauges water temp gauge and frequency meter (digital type) including safety automatic shutdown in case of fault such as high water temperature low oil pressure, over speed etc. including self-starter, alternator, cogged, V belt, fuel tank with first fill of lub oil and coolant(as applicable) etc. complete all as specified. Make of OEM for DG Set Engine/ Alternator :- (a) OEM :- (i) M/s KOEL Green, (ii) M/s Sudhir Power Ltd, (iii) M/s Greaves Power, (iv) M/s Jackson Ltd (b) Engine :- (i) Kirloskar, (ii) Cummins, (iii) Greaves Power, (iv) Cummins (c) Alternator :- (i) Kirloskar Green, (ii) Stamford, (iii) Crompton Greaves, (iv) Stamford
(B) ALTERNATOR: Alternator AC ,3 phase 415 volts 4 wire rated line current for output 160 KVA, PF 0.8 1500 RPM confirming to BS 5000 directly coupled with above engine. The Alternator shall be brushless type, screen protected, revolving field, self-exited, self-regulated through an AVR. The alternator has the following features :- (i) + 0.5% voltage regulation (max) in static conditions (ii) IP-23 protection with insulation class H (iii) Permissible overload of 10% for one hour in 12 hours of operation. (iv) Anti-vibration pads for mounting engine and alternator assembly on the base frame/plate or as recommended/provided by the manufacturer. (C) Base frame made out of structural steel as per manufacturer's recommended design/specifications. (D) ACCOUSTIC ENCLOSURE Provision of an integral type approved/certified acoustic enclosure. It shall be made of 16 SWG or manufacturer's standard norms out of CRCA sheet with powder coated finish on outside and provided with non-igniting fire retardant foam as acoustic material of suitable thickness and perforated sheet of stainless steel as per manufacturer design. The doors and glass window shall be as per manufacturer's design. The base frame shall be of ISMC.It shall also include the following:- (i) Silencer: Suitable exhaust Residential grade silencer to reduce the noise level. (ii) Internal wiring with PVC copper cable (ISI 694marked) FRLS in conduit and for light and fan point lamp fittings including lamp. (iii) Fuel tank: Sub Base Fuel tank of 14 SWG MS sheet of capacity considered as per OEM duly powder coated. (iv) One No of 12V 180 Ah maintenance free batteries as recommended by manufacturer. (E) The standard digital control Panel suitable to accommodate inside acoustic enclosure all as specified. (F) Base rail : Base rail with integral fuel tank is provided.
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.50 metres below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layers of charcoal dust and common salt filling in alternate layers alround, top & bottom and electrode connection by using earth strip 32x6mm connected to earth plate electrode by means of bolts, nuts check nuts and washers made of galvanized iron or steel and thimbles, GI pipe light grade 15mm bore for watering with funnel and wire mesh, GI light grade 20mm bore protection pipe for drawing in earth lead wire, PCC chamber in PCC 1:2:4, type B-1 with angle iron 25x25x3mm frame work and pre-cast RCC cover in RCC 1:2:4, type B-1, cover reinforced with 8mm dia TMT bars @100mm c/c both ways and 12mm dia MS fabricated handle, test point complete all as shown in electrical plate No 3 of MES Standard Schedule of Rates (Part-I) including necessary excavation and earth work in any type of soil, returning filling and removal of soil to a distance not exc 50 metres and testing on completion complete all as specified and directed. Notes (a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made. (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (c) If the testing result of earthing work is not found satisfactory then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account. (d) Earthing work will be carried out in presence of MES representative.
SITE CLERANCE & EARTH WORKS
Excavation in trenches in soft/loose soil including cutting road surface n. exc 1.5 mtr wide and not exceeding 1.5m depth for laying of cable/pipe and getting out complete all as specified and as directed.
Excavation in trenches in soft/loose soil exceeding 1.5 mtr deep and not exc 3.00m in depth not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in soft/ loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of excavated spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
SHRI RAMSONS PROJECTS CORPORATION
HVAC Engineering Co
SATISH AND CO
Leo Air and Power Solution pvt Ltd.
BRITE INDUSTRIES
Intrernational Engineers
Parksons Engineering Company Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .