Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹17.4 L+₹1.1 L (6.53%)Rejected-AOC 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹17.9 L+₹1.6 L (9.53%)Rejected-AOC BUNGLOW NO 5 RA LINES NEAR DOGRA MANDIR MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹17.9 L+₹1.6 L (9.54%)Rejected-AOC C 92 JAIN NAGAR RAILWAY ROAD MEERUT UP | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹19.5 L+₹3.1 L (19.0%)Rejected-AOC 2 78 SHARDHA PURI PHASE I KANKER KHERA MEERUT UP 250001 | MEERUT | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
30 May 2020, 6:00 pmClosed
Garrison Engineer (South) Meerut Cantt
GE (South) Meerut Cantt, Distt-Meerut, State (UP), PIN-250001
REPAIR/CLEANING OF SEWAGE LINES, MANHOLES, SEPTIC TANK, SOAK WELL ETC IN ZONE V AREA UNDER AGE B/R-IV OF GE(SOUTH) MEERUT CANTT
2020_MES_341713_1
GE/MRT/S/8755/2020-2021
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please prefer tender documents
10 documents required · 10 mandatory
₹500
GE (South) Meerut
₹50,000
Yes
19 Jun 2020
29 Apr 2020
2 Jun 2020
29 Apr 2020
30 May 2020
16 May 2020
Amount
Material and labour for cleaning and clearing blockage of sewage lines, manhole by rodding and well flushing the sewage lines after removing of sludge including removing the manhole cover and refixing after cleaning of manhole of any size and depth. The manhole lines to be cleaned manually/mechanical sludge trailor and all sludge to be removed to a distance of 3km outside of the cantt area. (Note : (a) The contractor shall provide sufficient labours everyday to clear for all types of sewage line blockage complaints. (b) The period of completion for each complaints shall be 24 hours. (c) It shall be the responsibility of the contractor to get the complaints completed with in stipulated period the labour shall be made available during the office hours for any complaints. (d) The payment shall be made to the contractor on the basis of job done on compliants slips for each complaints. No payment shall be made for any incomplete work. The rates quoted by the contractors shall deemed to be included the above aspects & nothing extra shall be admissible on this account.
All as per item No 1.00 above but cleaning the blockage of WC's, toilets, kitchen, Sink etc complete all as specified and directed.
Dewatering of soak well/soak pit including connected septic tank by discharging the sewage water into a sealed tanker with pipe system including vehicle and other arrangements and disposing within 3 KM outside cantt area complete all as directed by Engineer-in-Charge.( Note : 4000 Ltr capacity tank shall be meausred as one unit )
Excavation and getting out of sludge from septic tank in any depth by any means and removing to the distance up to 3 kms outside cantt area and disposed in approved areas all as directed by Engineer-in-Charge.
Material & labour for 150 mm bore salt glazed stoneware drain pipes Grade 'A' laid in trenches and jointed as specified including demolition of old drain pipes ( SGSW) complete all as specified and directed.
Material & labour for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) for 150 mm bore pipe complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in surface channel or drains complete all as specified and directed.
Material & labour for repairs to CI/AC down take pipes for arresting leakage using rubber or fibre based gasket upto 4th storey height complete all as specified and directed.
Supply and fix as in repair cast iron bends (any radius), diminishing pieces or tapers (largrer bore measured), suitable for 100 mm bore spun pipes, ISI marked complete all as specified and directede.
M&L for cleaning sewage line/effluent drain 150mm dia and disposing off all as specified and directed under item no 1 above of BOQ complete all as specified and directed.
Material & labour for cleaning of sewage line/effluent drain 200 mm dia and disposing off all as specified and directed in item No 1 above.
Excavation in trenches n exc 1.5 m wide and n.exc 1.5 m in depth in soft/ loose soil for foundation etc or for shaft, wells, manholes,pier holes etc n exc 10 Sqm on plan and getting out and levelling of bottom surface to required level complete all as specified and directed.
All as per item No 12.00 above but depth exc 1.50m and n.exc 3.0 m complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25cm thick in soft / loose soil complete all as specified and directed.
Removing excavated soil to a distance not exc 50 m and deposited where directed at a level not exc 1.5 m above the starting point all as specified and directed.
Material and labour for providing Cement concrete 1:3:6 Type C-2 (using 40 mm graded crushed stone aggregates), in foundations, filling and mass concrete complete all as specified and directed.
Demolition brick work built in cement mortar including all quoins ,arches, pillars etc complete all as specified and directed.
Material and labour for brick work with fly ash bricks straight or curved exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed.
All as per item No 18.00 above but except bricks including cleaning of old bricks complete all as specified and directed.
Material & labour PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in coping and benching and the like including weathering slightly rounded or chamfered angle and throating complete all as specified and directed.
Material and labour for rendering, 15 mm thick in cement mortar (1:6) on fair faces of brick wall finished even and fair including taking down cement plaster on brick work or stone walls etc including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
Material and labour rendering 10 mm thick in CM 1:4 on fair faces of brick wall finished fair and even complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n.exc 15cm thickness(below or above ground level) and including removal of debris & rubbish from the site complete all as specified and directed.
Material and labour reinforced cement concrete M-25 design mix type B 1 (using 20 mm graded crushed stone aggregates) as in slabs supported on walls as in soak well/septic tank etc complete all as specified and directed.
M&L for form work to soffits of suspended slabs (horizontal or sloping) such as roof slab, floor slab, landing and similar work not exceeding 200 mm thick for rough finished surfaces of concrete complete all as specified and directed.
M&L formwork to edges of RCC slab for septic tank and soak well, railings, n.exc 20cm wide and sides of RCC band in walls, sloping and similar work for rough finished surfaces of concrete flat complete all as specifeid and directed.
Material & labour for pre-cast cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slabs set in cement mortar 1:6 including necessary form work and placing in desired place/location and including demolition of damaged precast RCC cover and clearing the debries complete all as specified and directed.
Material & labour for TMT Bars 8 to10mm dia cut to length bent to shape required inculding cranking bending spirally and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F PVC pipes single socketed in any length with rubber ring joints, fixed to walls, laid under floors etc 110mm bore as in waste or rain water pipes including demolition and breaking of old u/s drain pipes complte all as specified and directed.
S&F PVC pipes single socketed in any length with rubber ring joints, fixed to walls, laid under floors etc 75mm bore as in waste or rain water pipes including demolition and breaking of old u/s drain pipes complete all as specified and directed.
Supply and fix in repair 110mm bore PVC (SWR) bends any radius jointed with cement solvent complete all as specified and directed.
Supply and fix in repair 75mm bore PVC (SWR) bends any radius jointed with cement solvent complete all as specified and directed.
Supply and fix in repair vitreous china squatting pan ‘Orissa pattern’ size 580 x 440 mm white, with integral foot rest including connection to drain pipe and to flushing pipe and including making good the disturbed surfaces to match the existing surfaces complete all as specified and directed.
Supplied and fixed in repair PVC (SWR) 75 mm dia junction, single (single 'Y') equal or unequal complete all as specified and directed.
Supply and fix in repair PVC floor trap, 75 mm dia with stainless steel grating including jointing to waste pipe in cement mortar 1:2 & set in cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) complete all as specified and directed.
All as per item No 35.00 above but 100mm nahani trap complete all as specified and directed.
Supply and fix in repair 110mm bore PVC (SWR) junction single, (single 'Y') equal or unequal complete all as specified and directed.
SA construction co.
jitendra AND Co
Rajneesh Jain
SARSWATI ENTERPRISES
SHAKTI CONSTRUCTION CO
Punit Jain
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .