| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 CrAccepted-AOC | ₹13.2 Cr Quoted ₹13.4 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹13.5 CrRejected-AOC | ₹13.5 Cr | L2 | Rejected-AOC Rejected |
| 3 | L3₹13.9 CrRejected-AOC | ₹13.9 Cr | L3 | Rejected-AOC Rejected |
| 4 | Not Admitted-Fee | - | - | Not Admitted-Fee EMD/Instrument is not valid |
Tender Value
₹10.3 Cr
EMD Value
₹10.7 L
Closing Date
22 Feb 2022, 5:00 pmClosed
Executive Engineer
JSV Division Rohru
SH Site development for all Civil Structures C O Head weir C O Anckor block for R main C O Delivery tank Zone 1st at node 750000 Litrs Cap C o Sump well Zone 2nd at node 840000 Litrs Cap C O Delivery tank Zone 2nd at node 9 20000 Litrs Cap C o
2022_HPIPH_56286_1
JSV-RD-AB-E-Tender/21 10795-830
Open Tender
Civil Works - Others
365 days
Rohru Town
Tender Document
10 documents required · 10 mandatory
₹2,500
Yes
EE Rohru
₹10.7 L
Yes
Tutukandi Shimla
24 Aug 2022
1 Feb 2022
23 Feb 2022
1 Feb 2022
22 Feb 2022
1 Feb 2022
8 Feb 2022
Amount
Cutting in earth work and disposal of excavted earth all kind of soil with in all leads and lifts as per the direction of the Engineer in Charge P&J work.
Excavation in earth work and disposal of all excavated earth upto all leads and lifts. Disposing earth to be levelled and neatly dressed pick jumper work within all leads and lifts and as directed by the Engineer-in-charge.
Excavation in foundations , trenches etc., in earth work , lift up to 1.50 metres. Stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15 cm. (fifteen centimetres) layers , when required in to plinth and sides of foundations etc., conslolidating each of the disposited layer by ramming and watering and then disposing off all excavated soil as directed with in the load of 20 mtrs. Pick and Jumper work etc. complete as per the direction of the Engineer - in - Charge.
Providing & Laying cement concrete 1:6:12(1ccement :6 sand: 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts as per the directions of the Engineer in charge.
Providing and laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40mm( Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-in-Charge.
Providing from work steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooded battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for in situ reinforced concrete and plain concrete work with in all leads aand lifts as per the direction of the Engineer in Charge.
i) Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like.
ii) Flat surfaces such as soffits and suspended floors, roofs landing and the like: Floors etc up to 200 mm in thickness .
iii) Edge of slab and breaks in floors and wall under20cm wide within all leads and lifts.
iv) Foundation footing bases of column and mass concrete.
v) Column, pillar & poat upto floor two level square, rectangular and polygonal in plan.
vii) Beams, cantilevers, Girders & lintels sides and siffits of beams, hounching cantilever girder not exceeding 1 mtr. Depth.
viii) Arches upto 6.00 mts.span
viv) Sloping and bettering surfaces I/c folding plates where inclination to horizontal plane not exceed 30 degrees.
Providing & fixing CI Sluice valve (with hand wheel) as per IS : 780-1984 class-I upto 300 mm dia.(i/c brass spindle & as per 2906-1984 class-II for dia.> 300 mm) complete with bolts nuts,rubber insertion etc.,(the tail piece if required shall be measured & paid for separatly)
50mm dia.
65mm dia.
Prov. & fixing SFRC Man hole cover with frame having frames size of 560 mm internal dia.should not be less than 58 kg
Providing and laying cement concrete 1:1.5:3(1cement:1.5 approved sand:3approved graded stone agg. 20mm nominal size) & curing complete excluding cost of form work in foundation and plinth:
i) Foundation and plinth (bed) with in all leads and lifts.
ii) Column, pillar & poat upto floor two level.
iii Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
(v) Wall (any thickness but not less than 0.1 m thickness) attached pilasters,buttresses, plinth and string courses etc. from top of foundation level up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Providing and laying cement concrete 1:1:2 (1cement :1Sand: 2 graded stone aggregate 20 mm N/S) and curing complete excluding cost of form work and reinforcement for Rainforced concrete work in:-
i) Foundation and plinth (bed) with in all leads and lifts.
(iii) Wall (any thickness but not less than 0.1 m thickness) attached pilasters,buttresses, plinth and string courses etc. from top of foundation level up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Providing mild steel/ tor steel reinfircement for rainforced concrete work I/C bending, binding and placing in position complete upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in : i)Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
(ii) Wall (any thickness but not less than 0.1 m thickness) attached pilasters,buttresses, plinth and string courses etc. from top of foundation level up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
(iii) Arches upto floor two level.
Providing in RCC work smooth finishing of the exposed surface with cement mortor1:3 (1cement :3 sand )with in all leads and lifts as per direction of the Engineer in Charge.
R/R masonary/polygone rubble masonry (uncoursed/brought to course) with hard stone of approved quality in foundation & plinth including levelling up with cement concrete 1:6:12 (1cement:6sand:12aggrigate 20mm nominal size)at plinth level in CM 1:6 (1cement:6sand) within all leads and lifts as per the directions of the Engineer in charge.
Boulder/Stone filling behind retaing wall & crate wall within all leads and lifts and as directed by the Engineer-in-charge.
Steel work in single sections including cutting hoisting fixing in position and applying a priming coat of red lead paint in R.S. joists, channels, angles, Tees, with in all leads and lifts as directed by the Engineer -In-charge
10mm cement plastering in single coat on fair side of brick/concrete wall for internal plastering upto floor two level i/c arrises internal angles, chamfers and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:3 (1cement : 3 Sand ) with in all leads and lifts as per direction of the Engineer in Charge.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter. with in all leads and lifts as per the direction of the Engineer in charge.
Wire crates of GI wire filled with boulders with square cut faces against the wire (wire crates to be measured and paid for separately , with in all leads and lifts as per the direction of the Engineer - in - Charge.
Wire crates made of GI wire filled with boulders with square cut faces against the wire (boulder filling to be measured and paid for separately , with in all leads and lifts as per the direction of the Engineer - in - Charge. GI wire 5mm thick corresponding to SWG-6 15x15 mesh.
Half Brick masonary using common burnt clay building bricks above plinth upto floor two level in cm 1:4(1cement:4sand)conventiohal brick first class within all leads and lifts and as directed by the Engineer-in-charge.
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)
Wall painting (Two coats) with acrylic emulsion paint of approved brand and manufacture for interior grade on undecorated concrete/stone/plastered wall surfaces to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth including applying of putty a required for metling the surface.
Finishing wall with water profing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials.
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters white paint
Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc. 100mm spread thickness (finished work including materials and laboour) within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing anodized Mild Steel sliding door bolts withnuts and screws complete I) 250mmX16mm with in all leads and lifts as per the direction of the Engineer in charge.
Providing and fixing anodized aiuminium. tower bolts barrel type with screws etc. complete.
I) 200mmX10mm
ii) 100mmx10mm
Providing and fixing anodized mild steel .handles with screws etc. complete. with in all leads and lifts as per the direction of the Engineer in charge.
I)125mm dia
ii) 100mm dia
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and per the directions of the Engineer in charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Supplying of various materials for pump house.
(i)Tool Kit for Pump house (24 items) with all accessory etc.
(i) Insulation mate (6'x4'), Bearing puller, insulation gloves & gress gen 1 No each ofr pump house
(iii) Steel / C.I.chairs,Poly table & stool 1 no each for pump house.
(iv) P/F of gantry girder 1 No each of pump house( 1.5 T)
Providing & fixing of Finalax pipe 40 mm dia. Under floor ( for connection cables ) including all req. fitting i:e elbows,sockets etc.
Supplying and fixing woven plain GI fencing of mesh 50 to 150mm to any type of standard rails strainging bolts etc. i/c provision of binding wire etc.
Providing and laying heavy duty precast cement conrete inter locking precast cement conrete inter locking paver blocks vibro compacted upto M-50 grade i/c border or kurb block grey or coloured over sub-base of concrete with 25mm thick average thickness of cement mortar 1:4 (1 cement : 4 sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks i/c curing rubbing & polishing complete (Sub base concrete floor to be paid for 60mm thick inter locking blocks
Providing and fixing 10mm thick antiskid water proof stain and impect resitent resistent heavy duty vetrified tiles Nitco or equivalent 600x600mmx10mm manufactured or approved shade and colour in flooring and landings laid over (12mm thick cement mortar 1:3)(1Cement:3Sand)jointed with cement slurry mixed with pigment to match the shade of tiles as required complete within all leads and lifts and as directed by the Engineer-in- charge..
Providing and fixing 0.45mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accesoriees as required as per the direction of Engineer-in-charge.
Providing and fixing ridges or hips 60 cm overall with 0.45mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accesoriees as required as per the direction of Engineer-in-charge.
Providing and fixing prepainted steel sheet ceiling with 0.30mm thick in panets of steel channels base frame in ceiling with screws complete (steel channels base frame to be measured and paid for separately
Providing and fixing anodised aluminium work for door, window, ventilators &partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised according to IS1868.(Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws up of gaps at junctions, at top, felt etc. Aluminium sections shall be smooth,All complete as per architectural drawings and the direction of Eingineer-in-charge
P/F in position rolling steel shutters with vertical chanels 20 mm x 10 mm x 2 mm & braced with flat iran diagonals 20mm x 5mm size with top and bottom rail of t iron 40 mm x 40 mm x6 mm with 38 mm dia steel pulley complate with bolts and nuts lockin arrangments , stoppers ,handles including appling a priming coat of red lead paint.
Providing and fixing glazing in aluminium door and windows ,ventilater shutters and partition etc.with PVC/ neorens gasket etc. complete as per the architewctural drawing and the directions of Engineer-in-Charge(cost of aluminium snap beadingshall be paidin basic item) glazing with glass panes of 5.50 mm thickness (weight not less than 13.75 kg/sqm.ly
Providing and placing horizontal layers filtering media duly graded screened washed and cleaned as specified by the Engineer Incharge with in all leads and lifts.
(i) Prov. Dry Bricks for filter bed/septic tanks
(ii) Coarse sand 3mm to 6mm
Providing and fixing vitreous China wash down water closet (European type. W.C. Pan) with integral 'P' or 'S' trap including jointing the trap with soil pipe in cement mortar 1:1 (1Cement : 1 Sand) (Seat and cover to be measured and paid for separately) Ordinary type.
Providing and fixing Stainless steel kitchen sink with drain board with in all leads and lifts as per the directions of the Engineer in charge. 470X 420X 178MM
Prorviding and fixing vitreous china wash basin with single hole for piller tap with C.I. or M.S. brackets painted white Flat back 630mmx450mm within all leads and lifts and as directed by the Engineer-in-charge.including cutting holes and making good the same but excluding fittings:-with in all leads and lifts as per the directions of the Engineer in charge.
Providing and fixing PTMT Coloured / white high density polyethlylene / poly propylene 10 liters cap. full flush European standard control low level flushing Cistern with fitting and within all leads and lifts and as directed by the Engin
P/F C.P. brass waste for wash basin or sink (i)32mm diawith in all leads and lifts as per the directions of the Engineer in charge.
P/F C.P. soap dish with C.P. brass brackets fixed to wooden cleats With C.P. brass screws with in all leads and lifts as per the directions of the Engineer in charge.
P/F C.P. Brass Bib tap with capstan head(15mm dia) with in all leads and lifts as per the directions of the Engineer in charge.
P/F brass full wheel valve with capstan head(15mm dia)within all leads and lifts and as directed by the Engineer-in-charge,
P/F C.P. Angle cock 15mm dia within all leads and lifts as per the directions of the Engineer-in-charge,
P/F of GI Elbow 15mm with in all leads and lifts as per the directions of the Engineer in charge.
P/F of GI Tee 15mm with in all leads and lifts as per the directions of the Engineer in charge.
P/F of GI Nipple 15mm with in all leads and lifts as per the directions of the Engineer in charge.
Providing and laying galvanized mild steel tube (heavy class) in wall. Ceiling including with in all leads and lifts as per the directions of the Engineer in charge .15mm dia(fiifteen milimetres)nominal size.(H . C )
Providing and fixing 600mmx450mm bevelled edge miror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixed to wooden plugs with C.P. Brass screws and washers. within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing in trenches 10 Kg.f/cum2 working pressure unplasticized P.V.C. pipe (Conforming to IS: 4985-1968) complete fittings (earth work in trenches to be measured and paid for separately):-
a)110 mm out side diameter.
b)Elbow 100 mm dia.
c)Clamps 100mm dia.
d)Door Bends
e)Plain bends
f)Collar
g) Cowl
h)Floor Traps
Wiring for light point/fan point/exhaust fan/call bell point with 1.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC Conduit conductor and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Group ( A.)
Wiring for power plug with 2x4 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 1 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group (A.)
Wiring for power plug with 4x4 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 2 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group (A.)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
2x1.5 Sq.mm.
2x10 Sq.mm.
Supplying & Fixing metal boxes of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
100mm.x100mm.x60mm. Deep.
180mm.x100mm.x60mm. Deep.
200mm.x150mm.x75mm. Deep.
200mm.x250mm.x100mm. Deep.
Supplying and fixing following rating Piano-type switch/socket on the existing switch box/cover including connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
S.P. 5/6 Amps one way switch, piano type.
S.P. 15/16 Amps one way switch, porcelain base/paino type.
5 pin 5/6 Amps socket outlet, poreclain base/piano type.
6 pin 15/16 Amps socket outlet, porcelain base/piano type.
Supplying and fixing bakelite batten/angle holder including connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and erection of 6 amps, to 32 amps, rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Single pole . Cat-A
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 40 Amps. Cat- A
Supplying and fixing of following way, single pole and netural sheet steel MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus-bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels inter-connections phosphatized and powder painted, including earthing etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Single door-6 way
Earthing with G.I. earth pipe 4.5mtr. Long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Extra for using salt and charcoal for pipe earth eletrode complete as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and laying 6 SWG G.I. wire at 0.50 mtr. Below ground level for earth electrode conductor, including soldering etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Providing and fixing sleek and decorative strip type fixture with domestic electronic ballast and colored engineering plastic end plates, suitable for 28 watt FTL (T5), complete with all accessoris (excluding the T-8 tube), connections, testing and commissioning etc. as required. 1x 28 watt-FTL (T5) (Category-A with in all leads and lifts as per direction of the Engineer-in-Charge.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and fixing of integral CFL Post Top Lantern of following capacity, cast aluminium spigot, spun alumnium canopy, opal acrylic diffuser, complete with all accessoreis but excluding CFL lamp including making connections, testing etc. as required. Gate post top lantern-FCL 26 watt. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and fixing Solar Street lights are raised light sources which are powed by solar panels generally mounted on the lighting structure or integated into the pole itself . The solar panels charge a rechargeable battery which powers a fluorescent of LED lamp during the night with in all leads and lifts as per direction of the Engineer-in-Charge. (Single panel) 9 watt
C/O Filter House/ Inspection Gallary i/c electrical installation
Providing centrifugal pumping machinery for wash water including the cost of base plate etc. including following items:-
Providing & fixing of MS angle iron and sheet metal floor mounting type switch board cosisting of following accessories :-
b) Voltmeter of reputed mahe of suitable range & conforming to relevant IS codes.
c) ICTP switches of reputed make and of suitable capacity
d) Three phase indicator lamps
e) Capacitor of suitable rating and of reputed make
f) Bus bar chamber complete in all respect.
g) Reputed make switch on incoming feeder
Providing & laying 250 mm dia. API X70 pipe for suction pipe , rising main & common header including MS flanges and welding complete.
Providing & laying 250 mm API X70 pipe dia.for delivery pipe including MS flanges and welding complete.
Prov. Dry Bricks for filter bed/septic tanks
(i) 250 mm dia.
(ii) 250 mm dia.
Providing and fixing CI Non return as per IS :5312 - 1984 complete in all respect.
(i) 250 mm dia.
Providing and laying flanged puddle collar
(i) 250 mm dia.
(ii) 250 mm dia.
Arrangements to fix necessary adopters in clear water sump and filter bed
Stand by head gauge indicator made of suitable pipe.
Loss of head indicator dial type to show the requiste losses.
Providing and laying flanged CI duck foot bend 90 degree.
(i) 250 mm dia.
(ii) 250 mm dia.
Providing and fixing filter bed assembly
Providing and fixing laterals with necessary holes assembly
Providing support to laterals
Providing and fixing nozlles
Providing and fixing end cap to manifolds
Providing and fixing extended spindle
Providing and fixing pedestal /stand
Providing and fixing V - notch in each filter with indicator lip (30000 GPH)
Providing and fixing air wash assembly for supply of air distributed on floor for proposed plant.
Providing and fixing rotary positive air blowers of requisite capacity to provide air at a pressure of required rating and having requisite delivery as per air wash pipe
Providing and fixing MS base plate for fixing air blowers & motors.
Providing requisite pressure gauge,belt guard and pulleys or coupling,V - belts,relief valve and silencer of the above motor.
Providing & fixing requisite capacity electric motor 1440 RPM TEFC
Providing necessary electric installation including starter, voltmeter, ampermeter, switch, bus bar chamber, indicator lamp,ON/ OFF switch with cablig complete
Providing & placing filter media for filtering the water complete in all respect as per entire satisfaction of Engineer in charge.
Providing under layer for plinth protection of 75 mm thick (uncolidated) bed of hard stone soling well rammed and consolidated and grouted with fine sand including preparation of ground
Providing & fixing 500 watts flood lights
Providing & fixing MS poles 6.00 mtr.height for fixing flood llight
Providing electric wiring,switches and boards etc.complete installation of flood lights including earthing etc.complete.Providing electric wiring,switches and boards etc.complete installation of flood lights including earthing etc.complete.
Providing, laying, jointing and testing in trenches of galvanized MSERW flanged pipes including cost of flanged bends of all degrees conforming to IS/ISO 3183-2007 Grade-A as per dimensions weight and test pressure mentioned below in a random length of 4m-7m, The M.S. flanges are to be provided 10% of total joints as per table below conforming to IS: 6392-1971 (latest upto date amendments) and welding of flanges with pipes as per IS: 816-1965 with a electrode as per IS: 814-1967 including required Nos. and size of M.S. nut and bolts as per IS: 1369-1967 and compressed asbestos fiber jointing gaskets sheet not less than 3mm thick sas per IS: 2712-1965. The welding of flanges to be done on both faces in two layers to make the joints leak proof and to the entire satisfaction of the Engineer-in-charge. The laying of pipes should be conformed to IS: 5822-1994 (earth work in trenches, MS flanges and butt welded joint to measured and paid seprately) . The pipe shall have zinc coating as per IS 4736 in factory latest with upto date ammendements.
Providing & fixing C.I. Sluice valve i/c spindle 65 mm dia PN-1.0
Pumping and Machinery: 4th Stage. Zone -1st Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single, /Multistages centrifugal pumps or combination of pumps.M/Hindustan pump and electrical engineering PVT. LTD in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti or any other make approved from Jal Shakti Vibhag as per BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to suitable for lifting clear water for under mentioned characteristics with bronze impellers/ priming funnels casing ring and shaft sleaves or bronze. shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I./Cast steel base platel (base plate to be from the manufacturers of the pumping unit only) to slip ring/squirrel cage screen protected drip proof induction motor of standard make such as Kirloskar/Crompton/Bhel/NGEF/ GEC/ Siemen/Jyoti/ABB or any other make approved from Jal Shakti Vibhag suitable for operation on 415(+) /-5% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-)25% of the duty point head. The motor should be as per IS:325-1978 with upto date ammendments read with IS:900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements (a) Pump: Specification 1) Make 2) Model 3) No of Stages 4) Material (Manufactured certificate to be appended performances) i) Head(H) 360.52 mtr. ii) Discharge 7.35 LPS iii) BHP Absorbed iv) Effeciency (n) v) NPSH b) Motor i) Make ii) Model iii) Motor rating iv) Speed v) Insulation.
i) Discharge (Q) 7.35 LPS each pump. ( 2 no. pumps one to work at a time independently)
ii) Total Dynamic head 360.52 mtrs.
a) LWL of sump well (h) 2800 mtr.
b) Shaft level 2800 mtr.
c) Level at discharge point 3100mtr.
d) suction lift (+) head 360.35 mtr.
e) Discharge head 300 mtr.
f) Static head 300 mtr.
iii) Rising main
a) Length 11000 mtr.
b) Dia 125 mm.
iv) Pumping hour 16 hours.
v) Altitude of installation above MSL mtr.
vi) Characterstics of water. Clear cold water
a) Temperature 0C.
b) Ambient temp. 0C.
c) Turbiduty JTU
d) Alkanality
e) Size of the solid NIL mm.
f) Other
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTC Switch Make Type Capacity
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject approval of Engineer-in-charge. Panel/Switch Board i) Drawing ii) Layout Plan
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB i) Make ii) Type iii) Range iv) Capacity
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS.It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side. ELCB i) Make ii) Type iii) Range Voltage relay meter i) Make ii) Type iii) Range
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment Power factor meter Type Make
Frequecy meter of standard make as per relevent IS code with upto date ammendments Frequency Meter i)Make ii) Type iii) Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating for full length for naturalnphase as per IS 8084-1976 and IS 11353-1985 read with BIS-5578-with upto date ammendments. Bus bar chanber i) Make ii) Type iii) Rating.
ICTC switches with HRC fuses of Kilburn/L&T/Siemens/Standard/ Havels make and of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTC Switches i) Type ii) Make iii) Capacity
Three phase indicator lamp complete with toggie switches for indivisual motor as per IS:3452 (P-l&lll) with up to date ammendments. Three phase indicator i)Type ii) Make iii) Capacity.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Capacitor i) Type ii) Make iii) Range.
Hour rum meter of reputed make.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slipering motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time log , under voltage release wfith initial oil filling. Single phase preventer i) Type ii) Make
Providing and fixing cast iron flanged/screw type stainer as per IS 4038-1986 with upto date ammendments of Kiloskar/GIED/ Kilburn/ Karter valve Mechneil/ Kilburn leader make 65mm dia. Foot Valve i) Make
Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414 Sluice Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of 50mm dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm. Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.Pressure Guage i) Make ii) Range
Providing, laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API- X 46 etc. The sizes of various components to be as under: l) Suction Pipe ---------- mm dia ii) Delivery Pipe ---------- mm dia iii) Common Header ---------- mm dia. and will be extended up to 5 mtr from the outer wall of the pump house in th direction to be jointed. Suction Pipe i) Material ii) Grade iii) Thickness iv) Pressure Rating - Delivery pipe and common header i) Material ii) Grade iii) Thickness iv) Pressure Rating
Providing and laying copper PVC insulated armoured power cable (One vable carrying all the three phasees) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-1) 1988 or latest with up to date ammendments of seimence/Gloster/IEC/EICO/National/Grandly make including all other accessories such as thimbles, flexible pipe, solder, nut & bolts, vable gland etc. laid in pipe or trenches under floor. Armored power cable a) Motor side (From switch to starter 20 mtr. And starter to Motor.10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment. Armored power cable of HPSEB to bus bar 10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
Pumping and Machinery: 1st- Stage. Zone-2nd Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single, /Multistages centrifugal pumps or combination of pumps. M/Hindustan pump and electrical engineering PVT. LTD in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti or any other make approved from Jal Shakti Vibhag as per BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to suitable for lifting clear water for under mentioned characteristics with bronze impellers/ priming funnels casing ring and shaft sleaves or bronze. shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I./Cast steel base platel (base plate to be from the manufacturers of the pumping unit only) to slip ring/squirrel cage screen protected drip proof induction motor of standard make such as Kirloskar/Crompton/Bhel/NGEF/ GEC/ Siemen/Jyoti/ABB or any other make approved from Jal Shakti Vibhag suitable for operation on 415(+) /-5% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-)25% of the duty point head. The motor should be as per IS:325-1978 with upto date ammendments read with IS:900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements (a) Pump: Specification 1) Make 2) Model 3) No of Stages 4) Material (Manufactured certificate to be appended performances) i) Head(H) 850 mtr. ii) Discharge 5.88 LPS iii) BHP Absorbed iv) Effeciency (n) v) NPSH b) Motor i) Make ii) Model iii) Motor rating iv) Speed v) Insulation.
i) Discharge (Q) 5.88 LPS each pump.( 2 no. pumps one to work at a time independently)
ii) Total Dynamic head 893.25 mtrs.
a) LWL of sump well (h) 1630 mtr.
b) Shaft level 1630mtr.
c) Level at discharge point 2480 mtr.
d) suction lift (+) head 893.25 mtr.
e) Discharge head 893.25 mtr.
f) Static head 850 mtr.
iii) Rising main
a) Length 3900 mtr.
b) Dia 100mm.
iv) Pumping hour 16 hours.
v) Altitude of installation above MSL mtr.
vi) Characterstics of water. Clear cold water
a) Temperature 0C.
b) Ambient temp. 0C.
c) Turbiduty JTU
d) Alkanality
e) Size of the solid NIL mm.
f) Other
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTC Switch Make Type Capacity
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge. Panel/Switch Board i) Drawing ii) Layout Plan
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB i) Make ii) Type iii) Range iv) Capacity
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS.It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side. ELCB i) Make ii) Type iii) Range Voltage relay meter i) Make ii) Type iii) Range
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment Power factor meter Type Make
Frequecy meter of standard make as per relevent IS code with upto date ammendments Frequency Meter i)Make ii) Type iii) Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating for full length for naturalnphase as per IS 8084-1976 and IS 11353-1985 read with BIS-5578-with upto date ammendments. Bus bar chanber i) Make ii) Type iii) Rating.
ICTC switches with HRC fuses of Kilburn/L&T/Siemens/Standard/ Havels make and of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTC Switches i) Type ii) Make iii) Capacity
Three phase indicator lamp complete with toggie switches for indivisual motor as per IS:3452 (P-l&lll) with up to date ammendments. Three phase indicator i)Type ii) Make iii) Capacity.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Capacitor i) Type ii) Make iii) Range.
Hour rum meter of reputed make.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slipering motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time log , under voltage release wfith initial oil filling. Single phase preventer i) Type ii) Make
Providing and fixing cast iron flanged/screw type stainer as per IS 4038-1986 with upto date ammendments of Kiloskar/GIED/ Kilburn/ Karter valve Mechneil/ Kilburn leader make 65mm dia. Foot Valve i) Make
Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414 Sluice Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm. Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. Pressure Guage i) Make ii) Range
Providing, laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API- X 46 etc. The sizes of various components to be as under: l) Suction Pipe ---------- mm dia ii) Delivery Pipe ---------- mm dia iii) Common Header ---------- mm dia. and will be extended up to 5 mtr from the outer wall of the pump house in th direction to be jointed. Suction Pipe i) Material ii) Grade iii) Thickness iv) Pressure Rating - Delivery pipe and common header i) Material ii) Grade iii) Thickness iv) Pressure Rating
Providing and laying copper PVC insulated armoured power cable (One vable carrying all the three phasees) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-1) 1988 or latest with up to date ammendments of seimence/Gloster/IEC/EICO/National/Grandly make including all other accessories such as thimbles, flexible pipe, solder, nut & bolts, vable gland etc. laid in pipe or trenches under floor. Armored power cable a) Motor side (From switch to starter 20 mtr. And starter to Motor.10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment. Armored power cable of HPSEB to bus bar 10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
Pumping and Machinery: 2nd Stage.Zone-2nd Stage. 2nd Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single, /Multistages centrifugal pumps or combination of pumps. M/Hindustan pump and electrical engineering PVT. LTD in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti or any other make approved from Jal Shakti Vibhag as per BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to suitable for lifting clear water for under mentioned characteristics with bronze impellers/ priming funnels casing ring and shaft sleaves or bronze. shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I./Cast steel base platel (base plate to be from the manufacturers of the pumping unit only) to slip ring/squirrel cage screen protected drip proof induction motor of standard make such as Kirloskar/Crompton/Bhel/NGEF/ GEC/ Siemen/Jyoti/ABB or any other make approved from Jal Shakti Vibhag suitable for operation on 415(+) /-5% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-)25% of the duty point head. The motor should be as per IS:325-1978 with upto date ammendments read with IS:900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements (a) Pump: Specification 1) Make 2) Model 3) No of Stages 4) Material (Manufactured certificate to be appended performances) i) Head(H) 500 mtr. ii) Discharge 2.66 LPS iii) BHP Absorbed iv) Effeciency (n) v) NPSH b) Motor i) Make ii) Model iii) Motor rating iv) Speed v) Insulation.
i) Discharge (Q) 2.66 LPS each pump.( 2 no. pumps one to work at a time independently)
ii) Total Dynamic head 580.26 mtrs.
a) LWL of sump well (h) 1650 mtr.
b) Shaft level 2477 mtr.
c) Level at discharge point 2977 mtr.
d) suction lift (+) head 580.26 mtr.
e) Discharge head 580.26 mtr.
f) Static head 500mtr.
iii) Rising main
a) Length 4000 mtr.
b) Dia 65 mm.
iv) Pumping hour 16 hours.
v) Altitude of installation above MSL mtr.
vi) Characterstics of water. Clear cold water
a) Temperature 0C.
b) Ambient temp. 0C.
c) Turbiduty JTU
d) Alkanality
e) Size of the solid NIL mm.
f) Other
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTC Switch Make Type Capacity
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge. Panel/Switch Board i) Drawing ii) Layout Plan
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB i) Make ii) Type iii) Range iv) Capacity
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS.It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side. ELCB i) Make ii) Type iii) Range Voltage relay meter i) Make ii) Type iii) Range
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment Power factor meter Type Make
Frequecy meter of standard make as per relevent IS code with upto date ammendments Frequency Meter i)Make ii) Type iii) Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating for full length for naturalnphase as per IS 8084-1976 and IS 11353-1985 read with BIS-5578-with upto date ammendments.Frequency Meter i)Make ii) Type iii) Range
ICTC switches with HRC fuses of Kilburn/L&T/Siemens/Standard/ Havels make and of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTC Switches i) Type ii) Make iii) Capacity
Three phase indicator lamp complete with toggie switches for indivisual motor as per IS:3452 (P-l&lll) with up to date ammendments. Three phase indicator i)Type ii) Make iii) Capacity.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Capacitor i) Type ii) Make iii) Range.
Hour rum meter of reputed make.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slipering motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time log , under voltage release wfith initial oil filling. Single phase preventer i) Type ii) Make
Providing and fixing cast iron flanged/screw type stainer as per IS 4038-1986 with upto date ammendments of Kiloskar/GIED/ Kilburn/ Karter valve Mechneil/ Kilburn leader make 65mm dia. Foot Valve i) Make
Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414. Sluice Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm. Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. Pressure Guage i) Make ii) Range
Providing, laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API- X 46 etc. The sizes of various components to be as under: l) Suction Pipe ---------- mm dia ii) Delivery Pipe ---------- mm dia iii) Common Header ---------- mm dia. and will be extended up to 5 mtr from the outer wall of the pump house in th direction to be jointed. Suction Pipe i) Material ii) Grade iii) Thickness iv) Pressure Rating - Delivery pipe and common header i) Material ii) Grade iii) Thickness iv) Pressure Rating
Providing and laying copper PVC insulated armoured power cable (One vable carrying all the three phasees) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-1) 1988 or latest with up to date ammendments of seimence/Gloster/IEC/EICO/National/Grandly make including all other accessories such as thimbles, flexible pipe, solder, nut & bolts, vable gland etc. laid in pipe or trenches under floor. Armored power cable a) Motor side (From switch to starter 20 mtr. And starter to Motor.10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment.
Pumping and Machinery: 1st Stage A. Zone-2nd Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single, /Multistages centrifugal pumps or combination of pumps. M/Hindustan pump and electrical engineering PVT. LTD in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti or any other make approved from Jal Shakti Vibhag as per BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to suitable for lifting clear water for under mentioned characteristics with bronze impellers/ priming funnels casing ring and shaft sleaves or bronze. shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I./Cast steel base platel (base plate to be from the manufacturers of the pumping unit only) to slip ring/squirrel cage screen protected drip proof induction motor of standard make such as Kirloskar/Crompton/Bhel/NGEF/ GEC/ Siemen/Jyoti/ABB or any other make approved from Jal Shakti Vibhag suitable for operation on 415(+) /-5% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-)25% of the duty point head. The motor should be as per IS:325-1978 with upto date ammendments read with IS:900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements (a) Pump: Specification 1) Make 2) Model 3) No of Stages 4) Material (Manufactured certificate to be appended performances) i) Head(H) 270 mtr. ii) Discharge 3.79 LPS iii) BHP Absorbed iv) Effeciency (n) v) NPSH b) Motor i) Make ii) Model iii) Motor rating iv) Speed v) Insulation.
i) Discharge (Q) 3.79 LPS each pump.( 2 no. pumps one to work at a time independently)
ii) Total Dynamic head 303.83 mtrs.
a) LWL of sump well (h) 1830 mtr.
b) Shaft level 1830 mtr.
c) Level at discharge point 2100 mtr.
d) suction lift (+) head 303.83 mtr.
e) Discharge head 303.83 mtr.
f) Static head 270 mtr.
iii) Rising main
a) Length 700 mtr.
b) Dia 65 mm.
iv) Pumping hour 4 hours.
v) Altitude of installation above MSL mtr.
vi) Characterstics of water. Clear cold water
a) Temperature 0C.
b) Ambient temp. 0C.
c) Turbiduty JTU
d) Alkanality
e) Size of the solid NIL mm.
f) Other
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTC Switch Make Type Capacity
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge.Panel/Switch Board i) Drawing ii) Layout Plan
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release. ACB/OCB i) Make ii) Type iii) Range iv) Capacity
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators,re-indicating off spring condition of the circuit braker for over current protection.The curcuit should be equipped with magnet thermal release with metallic tap CTS.It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side. ELCB i) Make ii) Type iii) Range Voltage relay meter i) Make ii) Type iii) Range
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment Power factor meter Type Make
Frequecy meter of standard make as per relevent IS code with upto date ammendments Frequency Meter i)Make ii) Type iii) Range
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating for full length for naturalnphase as per IS 8084-1976 and IS 11353-1985 read with BIS-5578-with upto date ammendments. Bus bar chanber i) Make ii) Type iii) Rating.
ICTC switches with HRC fuses of Kilburn/L&T/Siemens/Standard/ Havels make and of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTC Switches i) Type ii) Make iii) Capacity
Three phase indicator lamp complete with toggie switches for indivisual motor as per IS:3452 (P-l&lll) with up to date ammendments. Three phase indicator i)Type ii) Make iii) Capacity.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/GEC/Machneil/Masger/Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. Capacitor i) Type ii) Make iii) Range.
Hour rum meter of reputed make.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slipering motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time log , under voltage release wfith initial oil filling. Single phase preventer i) Type ii) Make
Providing and fixing cast iron flanged/screw type stainer as per IS 4038-1986 with upto date ammendments of Kiloskar/GIED/ Kilburn/ Karter valve Mechneil/ Kilburn leader make 65mm dia. Foot Valve i) Make
Providing and fixing cast iron double flanged sluice valve of class II 65mm dia of leader/ Behl Kirlsker/GIED/ Kilburn/Fouress make n suction side as per the relevent IS code.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414 Sluice Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2 The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Providing and fixing double flanged cast steel reflux valve of Leader/BHEL/Kilosker/Kilburn/ GLED/Fouress make and of 50mm dia for rising main having byepass arrangement for rising main andcapable withstanding the normal steel pressure as per IS 780-1984 with up to date ammendments class ASA to be mentioned by the firm. Reflux Valve i) Make ii) Class iii) Sheet Pressure iv) Material
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. Pressure Guage i) Make ii) Range
Providing, laying, testing & commissioning at site in trenches bevelled ended conforming to IS/ISO:3183-2007 latest having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with uptodate ammendements (leak proof) in three layers at site of work welding rods of Advani/oerliken make/ISI marked (welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail please, tees, bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-charge. The pipe shall have zinc coating inside & out side confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API- X 46 etc. The sizes of various components to be as under: l) Suction Pipe ---------- mm dia ii) Delivery Pipe ---------- mm dia iii) Common Header ---------- mm dia. and will be extended up to 5 mtr from the outer wall of the pump house in th direction to be jointed. Suction Pipe i) Material ii) Grade iii) Thickness iv) Pressure Rating - Delivery pipe and common header i) Material ii) Grade iii) Thickness iv) Pressure Rating
Providing and laying copper PVC insulated armoured power cable (One vable carrying all the three phasees) of suitable size and capacity to motors and all other electrical equipments as per IS:1554 (P-1) 1988 or latest with up to date ammendments of seimence/Gloster/IEC/EICO/National/Grandly make including all other accessories such as thimbles, flexible pipe, solder, nut & bolts, vable gland etc. laid in pipe or trenches under floor. Armored power cable a) Motor side (From switch to starter 20 mtr. And starter to Motor.10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
P/L double loop earthing with crpper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment. Armored power cable of HPSEB to bus bar 10mtr. i) Size ii) Make iii) Type Copper iv)Capacity v) Core 3
Providing, laying, jointing, testing& commissioning at site in trenches galvanized API pipe pipesbeveled ended IS/ISO:3183-2007 pipe conforming to IS/ISO:3183-2007 with latest up-to-dateamendments, having wall thickness as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be beveled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable and with up-to-dateamendments(leak proof) in three layers at site of work with welding rods of Advani/oerliken make/ISI marked(welding rods 3mm to 4mm ) and all allied accessories whatever required for welding at site including special short pieces, reducers, tail pieces,tees, bends & other specials manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions. And cutting of pipes wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-in-Charge. The laying of pipe shall include all operation such as cutting, welding, jointing, providing and fixing of MS flanges, fabrication of bends, tees,valves etc. Including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respect to the satisfaction of engineer-in-charge. The fabricated bends shall have three or four cuts having its radius not less thanfive times the dia of pipe.The pipe shall have zinc coating inside&outside confirming to IS-4736-1986 or latest with up to date amendments& shall be engraved with API X42. The laying shall confirm to BIS 5822-1970 or latest with up to date amendments to the entire satisfaction of Engineer In charge (Earth work & cost of MS flanges after 100meter length shall be measured and paid for separately.) including all leads, lifts and carriage of materials at site and as per direction and to the entire satisfaction of the Engineer-in Charge complete in all respects.
Zone-1st RD-0 to 7000 API-X42 W.T 4.80mm 125mm dia. 7000 rmt Stage 4th
Zone-2nd RD-0 to 600 API-X65 W.T 5.60mm 100 mm dia. . 600 Rmt Stage 1st.
RD-600 to 1500 API-X65 W.T 4.80mm 100mm dia. 900 Rmt
RD-1500 to 3000 API-X565 W.T 4.80mm 100mm dia. 1500 Rmt
RD-3000 to 3600 API-X65 W.T 4.80mm 100mm dia. . 600 Rmt
RD-3600 to 3900 API-X65 W.T 4.80mm 100mm dia. 300 Rmt
Zone-2nd RD-0 to 1800 L-245 W.T 4.80mm 65mm dia. 1800 Rmt Stage 2nd
Stage 2nd. RD-1800 to 2100 L-245 W.T 4.80mm 65 mm dia. . 300 Rmt
Zone-2nd RD-0 to 700 L-245 W.T 4.80mm 65mm dia. 200 Rmt Stage 1st. A
Providing and Laying, testing and commissioning at site in trenches bevelled ended BIS marked GI Heavy conforming to IS 1239 or it equivalent latest with uptodate ammendments of following dia of Heavy/ Medium class, having wall thickness and weight per Rmt. as mentioned below and capable of withstanding required test pressure as presscribed in BIS/IS)code, in random lengths of 5.5 to 6.5mtr. The pipes ends shall be bevelled suitable for butt welding, including the cost of ointing with butt welding confirming to IS 816-1969 or latest as appliable and with upto date ammendments (leak proof) in three layers at site of work with welding rods of Advani/Oerliken make/ISI marked(welding rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail pieces, tees bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specificatin as per site conditions and cutting of pipes wherever required as per site requirment i/c carriage in all leads & lifts and as directed by the Engineer-in-charge.
Zone-1st Stage 4th Heavy Class 125 mm dia.
Heavy Class 125mm dia.
Zone-2nd Stage 2nd Heavy Class 65 mm dia.
Heavy Class 65mm dia.
Zone-2nd Stage 1st A Heavy Class 65 mm dia.
Medium Class 65mm dia.
Providing and welding MS flanges as per table below conforming to IS:6392-1971( latest upto date amendments) and welding of flanges with pipes as per IS: 816-1965 with a electrode as per IS: 814-1967 including required Nos. and size of MS nuts and bolts as per IS: 1369-1967 and compressed asbestos fiber jointless gaskets sheet not less than 3mm thick as per IS: 2712-1965. The welding of flanges to be done in three layers ( two out side+one inside)to make the joints leak proof and to the entire satisfaction of the Engineer-in-charge.
Zone-1st Stage 4th API-X42 FT 28 T 4.80 125 mm dia.
Zone-2nd Stage 1st API-X65 FT 34 T 5.60 100 mm dia.
API-X65 FT 34 T 4.80 100 mm dia.
API-X65 FT 28 T 4.80 100 mm dia.
API-X65 FT 17 T 4.80 100 mm dia.
API-X65 FT 5 T 4.80 100 mm dia.
Zone-2nd Stage 2nd L-245 FT 28 T 4.80 65mm dia.
L-245 FT 17 T 4.80 65mm dia.
Zone-2nd Stage 1st A L-245 FT 28 T 4.80 65mm dia.
Providing, laying, jointing & testing of GMS pipe plain ended pipes with bevelled edge and capabale of with standing required test pressure,in random length of 5.5-6.5 meters i/c testing and commissioning and cost of jointing material sucha as MS Flange confirming to IS 6392-1971(leak proof) a/w nut bolt and washers of IS 1963 specification i/c rubber/asbestos fibre sheet gasket 3mm thick conforming to relevant IS specification & as per the direction of the Engineer in charge earth work in trenches to be measured and paid for seprately i/c all leads, lifts and carriage of materials at site.
Zone-1st Stage 4th Heavy Class FT 17 125 mm dia.
Heavy Class FT 5 125 mm dia.
Zone-2nd Stage 2nd Heavy Class FT 17 65mm dia.
Heavy Class FT 5 65mm dia.
Zone-2nd Stage 1st A Heavy Class FT 17 65 mm dia.
Medium Class FT 5 65mm dia.
Providing fixing , installation & testing of automation system with SCADA soft starters, control logic,clould integration/local server, IP cameras with remote mobile integration.for each set of Pumping Machinery of each Pump Houses as per directions of Engineer - in - charge.Capacity of motors (Booster Stage -2x10,1st stage 2x200, 2nd 2x220 , 3rd 2x177, 4th 2x60)Zone 2nd 1st 2x125,2nd 2x40,1st A 2X30) BHP
Laying , jointing and testing in trenches Galvanised Mild Steel tube of the following dia metres including smooth bending by necessary bends, or through pipe bending machine with necessary all pipe fittings such as Tees, Elbows, Union & Reducers etc. of ISI marked & testing for leakage complete with in all leads & lifts as per entire satisfication of Engineer - in - charge. (Earth work in trenches to be measured and paid for separately
15mm dia.
20mm dia.
25mm dia.
32mm dia.
40mm dia.
50mm dia.
65mm dia.
Providing and fixing of G.M. gate / C.I. Valves of various dia in pippes with in all leads & lifts as per directions of Engineer - in - charge.
15mm dia.
20mm dia.
25mm dia.
32mm dia.
40mm dia.
50mm dia.
65mm dia.
HARJEET SINGH
Unipro Techno Infrastructure Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid