Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹35.4 LAccepted-AOC | ₹35.4 L Quoted ₹36.7 L | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER |
| 2 | L-2₹36.8 LRejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹36.8 L | L-2 | Rejected-Finance BEING L2 BIDDER |
| 3 | L-3₹40.8 LRejected-Finance C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | ₹40.8 L | L-3 | Rejected-Finance BEING L3 BIDDER |
| 4 | L-4₹44.5 LRejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | ₹44.5 L | L-4 | Rejected-Finance BEING L4 BIDDER |
| 5 | L-5₹44.9 LRejected-Finance B 1 16 MILAN GARDEN SABHAPUR EXTENSION NEAR BHIKAM SINGH TUBE WELL NEW DELHI 110094 | NORTH EAST | DELHI | 110094 | ₹44.9 L | L-5 | Rejected-Finance BEING L5 BIDDER |
| Sl No | Description | Qty | Unit | M/S SITAL BUILDERS L1 | M/S S.S. Construction L3 | PURBANCHAL BUILDERS L2 | M/s SHARMA BUILDERS & ENGINEERS L6 | M/S SEWAK SINGH L4 | M/S K D TURAIHA L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 6 Sqmm section, complete all as specified and as directed by engineer-in-charge. | 100 | RM | 69 ₹6,900 | 50 ₹5,000 | 79 ₹7,900 | 110 ₹11,000 | 45 ₹4,500 | 40 ₹4,000 |
| 2.00 | All as per Item No. 01 here-in-above, but for cross-sectional area 10 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 200 | RM | 79 ₹15,800 | 85 ₹17,000 | 99 ₹19,800 | 130 ₹26,000 | 100 ₹20,000 | 60 ₹12,000 |
| 3.00 | All as per Item No. 01 here-in-above, but for cross-sectional area 16 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 200 | RM | 89 ₹17,800 | 118 ₹23,600 | 119 ₹23,800 | 140 ₹28,000 | 180 ₹36,000 | 80 ₹16,000 |
| 4.00 | Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 240 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. | 170 | RM | 2,099 ₹3.6 L | 2,100 ₹3.6 L | 1,879 ₹3.2 L | 2,600 ₹4.4 L | 2,900 ₹4.9 L | 1,650 ₹2.8 L |
| 5.00 | All as per Item No. 04 here-in-above, but for cross-sectional area 185 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 200 | RM | 1,679 ₹3.4 L | 1,650 ₹3.3 L | 1,419 ₹2.8 L | 1,900 ₹3.8 L | 1,950 ₹3.9 L | 1,350 ₹2.7 L |
| 6.00 | All as per Item No. 04 here-in-above, but for cross-sectional area 25 Sqmm 4 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 200 | RM | 339 ₹67,800 | 425 ₹85,000 | 299 ₹59,800 | 400 ₹80,000 | 400 ₹80,000 | 470 ₹94,000 |
| 7.00 | All as per Item No. 04 here-in-above, but for cross-sectional area 16 Sqmm 4 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 1,200 | RM | 279 ₹3.3 L | 340 ₹4.1 L | 239 ₹2.9 L | 300 ₹3.6 L | 350 ₹4.2 L | 440 ₹5.3 L |
| 8.00 | All as per Item No. 04 here-in-above, but for cross-sectional area 16 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 700 | RM | 194.19 ₹1.4 L | 190 ₹1.3 L | 189 ₹1.3 L | 240 ₹1.7 L | 230 ₹1.6 L | 400 ₹2.8 L |
| 9.00 | All as per Item No. 04 here-in-above, but for cross-sectional area 10 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 250 | RM | 184.99 ₹46,247.50 | 175 ₹43,750 | 169 ₹42,250 | 200 ₹50,000 | 210 ₹52,500 | 380 ₹95,000 |
| 10.00 | S&F in-repair of aluminium lug suitable for making connection of aluminium armoured xlpe cable of size upto 25 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 30 | EACH | 11.99 ₹359.70 | 12 ₹360 | 39 ₹1,170 | 50 ₹1,500 | 15 ₹450 | 15 ₹450 |
Updated dates
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Jan 2026, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
REPAIR/ MAINT OF LT UG CABLE, LT PANELS, DISTRIBUTION SYSTEM, DAY TO DAY MAINT OF INTERNAL ELECTRIFICATION AND OTHER CONNECTED WORKS AT HATTIGOR MIL STN UNDER GE RANGIA
2025_MES_744453_1
8844/RNG/E8
Open Tender
Electrical and Maintenance Works
270 days
HATTIGOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Rangia
₹1 L
Yes
19 Feb 2026
13 Dec 2025
12 Jan 2026
13 Dec 2025
10 Jan 2026
29 Dec 2025
13 Dec 2025 - 20 Dec 2025
S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 6 Sqmm section, complete all as specified and as directed by engineer-in-charge.
All as per Item No. 01 here-in-above, but for cross-sectional area 10 Sqmm, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 01 here-in-above, but for cross-sectional area 16 Sqmm, complete all as specified and as directed by Engineer-in-charge.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 240 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 04 here-in-above, but for cross-sectional area 185 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for cross-sectional area 25 Sqmm 4 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for cross-sectional area 16 Sqmm 4 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for cross-sectional area 16 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for cross-sectional area 10 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of aluminium lug suitable for making connection of aluminium armoured xlpe cable of size upto 25 Sqmm, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 10 here-in-above, but for cable size 35-95 Sqmm, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 10 here-in-above, but for cable size 120-300 Sqmm, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Cable end termination kit for 1.1 KV (Earthed) graded cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 sqmm to 150 sqmm, complete all as specified and as directed. Make - Denson/3-M/ Raychem/ Seimens
M&L for boring holes horizontally under road without damaging the road surface with the help of GI tubing not exc. 80mm bore dia for passing of UG cable, complete all as specified and directed by Engineer-in-charge. NOTE: GI Pipe will be measured and paid separately.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F of Galvanised Iron Pipe 50mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 20 here-in-above, but for 80mm bore (dia) pipe, complete all as specified and as directed by Engineer-in-charge.
Supply & Erecting in true vertical position of Steel Tubular Swaged Pole Type 410-SP-31 (9.00 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws with and including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying two Coats of Aluminium Painting over a coat of Red oxide Primer including necessary earthwork in excavation in any type of soil, removal of surplus soil to a distance of not exceeding 50.0m, Cement Concrete 1:3:6, type C-2 (40mm graded aggregate) as in Foundation of Poles filled upto ground level and Cement Concrete 1:2:4, Type B-1(20mm graded aggregate) as in Coping/Padestal of Poles and finishing the Concrete surfaces Fair and Even including necessary Formwork as required at Site(s) and dismantling the existing old damaged LT pole of any type, complete all as specified and as directed by Engineer-in-charge. NOTE: Earthwork, Cement Concrete, etc. will not be measured and paid separately.
M&L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of synthetic enamel paint in alternate Yellow & Black Strips (5 Nos. Strip of 300 mm wide each) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint, complete all as specified and as directed by engineer-in-charge.
S&F in-repair of MCCB 4 Pole, 415 Volts, 350 Amps, 50 Hz, conforming to IS/IEC 60898, with Thermal Magnetic release, overload, short circuit fault protection 3 phase, breaking capacity 36 KA, Ics=100% of Icu, with Spreader terminal of both ends, connecting and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 25 here-in-above, but for 250 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 25 here-in-above, but for 200 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 25 here-in-above, but for 160 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 25 here-in-above, but for 100 Amp capacity MCCB, breaking capacity 30 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 25 here-in-above, but for 63 Amp capacity MCCB, breaking capacity 30 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of On load Changeover Switch with sheet metal enclosure and advanced neutral switch, Four Pole (FP), 63 Amps, 415 Volts, conforming to IS/IEC 60947-3 with and including all accessories (side handle), connecting up and re-fixing of cables with proper lugs, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 31 here-in-above, but for 100 Amp capacity Changeover Switch, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Aluminium strip of 25 x 3.15mm with saddles and fixing screws etc. as earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Air termination, single pointed, copper rod 12mm dia and 300mm long with and including necessary base and insulator, complete all as specified and as directed by Engineer-in-charge.
SET OF TWO
S&F in-repair of cable route indicator made of cast iron, suitable for LT cable with 35x35x4mm thick MS angle iron post of 1.0m long embedded in PCC 1:3:6 type C-1 (20mm graded aggregates) as in bed block of 150x150x300mm deep, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of APFC relay of 08 steps and of size 96x96 mm suitable for upto 50KVAR APFC panel, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of CT coil 100/5 suitable for upto 50KVAR APFC panel, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of indicator lamps 22.5mm suitable for APFC panel, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MOC 12.5 contractor 240 Volts, suitable for APFC panel, complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (as/if requred), complete all as per specified and as directed by Engineer-in-Charge.
All as per Item No. 44 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 44 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 44 here-in-above, but for One 3/5 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Socket outlet 3/5 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 3/5 pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Modular Switch, One Module, 1-Way, 10 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F in-repair of Modular Switch, One Module, 1-Way, 20 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F in-repair of Modular Socket, 3 Pin, combined, Two Module, 10 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F in-repair of Modular Socket, 2/3 Pin, combined, Two Module, 20 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F in-repair of Modular stepped type electronic fan regulator, Two module, 240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of modular cover plate (white) with frame, 1-module, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of mo
dular cover plate (white) with frame, 2-module, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of modular cover plate (white) with frame, 3-module, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of modular cover plate (white) with frame, 4-module, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of modular cover plate (white) with frame, 6-module, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of modular cover plate (white) with frame, 8-module, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of modular cover plate (white) with frame, 12-module, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Socket outlet 3/5 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Switch socket combination 2 in 1, 3/5 pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Bell push, flush type, 5/6 amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Bell Buzzer/ Ding Dong, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface mounted PVC box of size 100 mm x 100 mm and 50 mm deep, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface mounted PVC box of size 100 mm x 175 mm and 50 mm deep, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface mounted PVC box of size 200 mm x 150 mm and 50 mm deep, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board and taking down the existing old unserviceable wiring, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
S&F in-repair of Sheet Metal Enclosure MCB DB TPN, 4 way 415 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 2 way 240 volt, with rated Bus-bar, Single door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 4 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 12 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Triple Pole & Neutral (TPN), 'C' Curve, 40-100 Amps, 415 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole & Neutral (SPN), 'C' Curve, 40-63 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED tube light fitting (separate batten and rod shall be measured as single unit) 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative regal type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED tube light fitting 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Decorative wall light made up of high grade engineering plastic material suitable for 20 W LED lamp B22 base, with necessary elecrical connections, complete as all specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED 20 Watts tube Rod (4 Feet) with plycarbonate housing and very high efficiency, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 10 watt capacity, B-22 base LED Bulb/ lamp (cool white/ warm white), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recess
ed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements, including taking down old unserviceable light fitting, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 92 here-in-above, but for 25 Watt street/ security light, complete all as specified and as directed by Engineer-in-charge.
M&L for disconnecting and taking down ceiling fan of 1200/1400 mm sweep and wall mounted/ padestal fan of upto 450mm sweep, sealing cable end, dismantling blades and removing fan and blades to store for Opening Stator, Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, re-winding the coil and Re-assembling the ceiling fan after proper repair and applying two coats of synthetic enamel paint over a coat of red oxide primer by spraying including filling cavities with filler, after cleaning all dust and necessary surface preparation including hanging the ceiling fan in original position and connecting up including provision of cable from ceiling rose or connector to fan (as/if required), complete all as specified and as directed by Engineer-in-charge. NOTE:- Spare-parts and cost of re-winding shall be measured and paid separately under relevent item.
M&L for re-winding the coil of ceiling fan 1200/1400 mm sweep/ pedestal fan upto 450mm sweep with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, complete all as specified and as directed by Engineer-in-charge.
Supply only Ball Bearing as approved suitable for Ceiling Fan of 1200mm / 1400 mm Sweep, complete all as specified and as directed by Engineer-in-charge. MAKE- SKF/ TATA/ KIRLOSKAR
S&F in-repair of Capacitor 3.15 mfd (as approved) 230 Volts, AC, 50Hz, suitable for Ceiling Fan of any Sweep and Make, complete all as specified and as directed by Engineer-in-charge. MAKE- Havells/ L&T/ Crompton Greaves
S&F in-repair of PVC fan blade suitable for pedestal fan/ wall fan of upto 450mm sweep, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Thermostat/Thermal cutoff suitable for Water Storage Geyser of range 0-90ºC as required, conforming to IS (Make as approved) complete all as specified and as directed.
S&F in-repair of Electro-plated Heating Element (as approved), suitable for Electric Geyser of 2.0 KW capacity, 240 Volts, complete all as specified and as directed. MAKE : BAJAJ/RECOLD/HAVELLS/USHA
S&F in-repair of wall fastener of size 100mm long, 8mm dia with double washers including grouting for fixing of water heater and making good the disturbed surfaces as per existing, complete all as specified and as directed.
S&F in-repair of stainless steel braided PVC connection pipe of 450mm long (02 Nos) with brass connector series for both inlet and outlet of Geyser, complete all as specified ans as directed.
S&F in repair Plug Top of 3Pin, 15/16 Amps capacity with indicator, complete all as specified and as directed. MAKE:- ANCHOR/L&T/HAVELLS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
8844TENDERDOCUMENT.pdf
Tender Documents • 0.40 MB
BOQ_833599.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid