Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.5 LAccepted-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIR PORT ROAD JAMMU INDEX NO D 04 ADGNJ | JAMMU | JAMMU AND KASHMIR | 180001 | L1 | Accepted-AOC AOC carried out on 16 Jan 26 | |
| 2 | L2₹70.5 L+₹11.0 L (18.5%)Rejected-Finance H NO 352 SECTOR 1 CHANNI HIMMAT JAMMU J K 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | GENESIS INDIA L2 | M/S ARUN ANAND L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster on bricks or stone wall/ decayed surfaces of concrete from roof projectiokn or RCC Chajjas etc. including racking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. | 1,550 | Sqm | 13 ₹20,150 | 10 ₹15,500 Lowest |
| 2.00 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cm 1:6 finished even and smooth (with out using extra cement) incl taking down cement plaster on brick wall etc. and racking out joints hacking for key complete all as specified and as directed. | 550 | Sqm | 215 ₹1,18,250 | 200 ₹1,10,000 Lowest |
| 3.00 | M&L Rendering 15 mm thick on fair faces of brick/concrete surfaces in cement plaster 1:4, using water proofing compound mix as per manufacturer detail, finished even and smooth without using extra cement, complete all as specified and as directed. | 750 | Sqm | 215 ₹1,61,250 Lowest | 230 ₹1,72,500 |
| 4.00 | M&L Rendering 5 mm thick on concrete surfaces in CM 1:3 finished on even and smooth without using extra cement as in ceiling, Chajja etc. complete all as specified and as directed. | 250 | Sqm | 215 ₹53,750 Lowest | 230 ₹57,500 |
| 5.00 | Taking down cement plaster and decayed concrete of any description, upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with liquid water proofing admixture or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick cement mortar 1:3, surface finished even and smooth without using extra cement using liquid water proofing admixtureas per manufacturer,s instructions , complete all as specified and as directed.
Note : Liquid water proofing admixture shall be measured & paid seprately. | 100 | Sqm | 550 ₹55,000 | 330 ₹33,000 Lowest |
| 6.00 | Supply only Integral water proofing compound liquid complete all as specified and as directed. | 40 | Ltr | 90 ₹3,600 | 67 ₹2,680 Lowest |
| 7.00 | M&L for glass fibre reinforced modified cementitious coating system before the final coat of a two component polymer modified cementations water proofing slurry mortar i.e liquid polymer component and a cement based powder with graded aggregates and additives.
Base coat: Styrene – Butadiene Latex based liquid used for water proofing.
Consumption base coat: 0.3 kg/m2
Reinforcement: Glass fiber
Second and Third coat: Two component polymer modified cementitions water proofing slurry mortar.
Consumption top coat: 3 kg/m2
System requirements: density: 2.00 kg/ltr;
compressive strength: 0.5 N/mm2.
• Wall penetration through the RCC slab must be sealed using a one component, non-sag, cementations mortar designed for patching and repairing concrete and other cement surfaces.
• Intersection of base slab with wall must be provided with a 50 mm fillet using styrene butadiene latex based liquid (modified motor polymer) used for water proofing with a bonding coat of styrene butadiene latex based liquid (modified cement slurry) used for water proofing upto 5ft.
• All depressions, unevenness, surface honeycombing shall be repaired using styrene butadiene latex based liquid (modified motor polymer) used for water proofing with a bonding coat of styrene butadiene latex based liquid (modified cement slurry) used for water proofing.
Including cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc | 60 | Sqm | 1,313 ₹78,780 | 600 ₹36,000 Lowest |
| 8.00 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with water proofing compound tobe finished even and smooth without using extra cement complete all as specified and as directed. | 60 | Sqm | 215 ₹12,900 Lowest | 230 ₹13,800 |
| 9.00 | S&F 20mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in as spout pipes to pour out rsidual water out from the treated area complete all as specified and as directed. | 10 | RM | 450 ₹4,500 | 250 ₹2,500 Lowest |
| 10.00 | M&L for hard core, of broken bricks broken to gauge n exc 63mm for laying sub base of thickness 150mm complete all as specified and as directed. | 5.2 | Cum | 1,450 ₹7,540 | 750 ₹3,900 Lowest |
Tender Value
₹80.7 L
EMD Value
₹2.5 L
Closing Date
4 Dec 2025, 6:00 pmClosed
Col Amit Bhardwaj
HQ CWE Jammu PIN-900172
SPECIAL REPAIR INCLUDING SEEPAGE LEAKAGE OF TOILET BATHROOM LINES OF BLDG NO-750 to 215 TRANSIT CAMP OF BD BARI MIL STN UNDER GE KALUCHAK
2025_MES_738591_1
CWE/JP-57/2025-26
Open Tender
Civil Works
Works
270 days
GE Kaluchak
As per tender docus
9 documents required · 9 mandatory
₹1,000
GE Kaluchak
₹2.5 L
Yes
16 Jan 2026
6 Nov 2025
6 Dec 2025
6 Nov 2025
4 Dec 2025
27 Nov 2025
6 Nov 2025 - 9 Nov 2025
Amount
Taking down cement plaster on bricks or stone wall/ decayed surfaces of concrete from roof projectiokn or RCC Chajjas etc. including racking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cm 1:6 finished even and smooth (with out using extra cement) incl taking down cement plaster on brick wall etc. and racking out joints hacking for key complete all as specified and as directed.
M&L Rendering 15 mm thick on fair faces of brick/concrete surfaces in cement plaster 1:4, using water proofing compound mix as per manufacturer detail, finished even and smooth without using extra cement, complete all as specified and as directed.
M&L Rendering 5 mm thick on concrete surfaces in CM 1:3 finished on even and smooth without using extra cement as in ceiling, Chajja etc. complete all as specified and as directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with liquid water proofing admixture or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick cement mortar 1:3, surface finished even and smooth without using extra cement using liquid water proofing admixtureas per manufacturer,s instructions , complete all as specified and as directed. Note : Liquid water proofing admixture shall be measured & paid seprately.
Supply only Integral water proofing compound liquid complete all as specified and as directed.
M&L for glass fibre reinforced modified cementitious coating system before the final coat of a two component polymer modified cementations water proofing slurry mortar i.e liquid polymer component and a cement based powder with graded aggregates and additives. Base coat: Styrene – Butadiene Latex based liquid used for water proofing. Consumption base coat: 0.3 kg/m2 Reinforcement: Glass fiber Second and Third coat: Two component polymer modified cementitions water proofing slurry mortar. Consumption top coat: 3 kg/m2 System requirements: density: 2.00 kg/ltr; compressive strength: 0.5 N/mm2. • Wall penetration through the RCC slab must be sealed using a one component, non-sag, cementations mortar designed for patching and repairing concrete and other cement surfaces. • Intersection of base slab with wall must be provided with a 50 mm fillet using styrene butadiene latex based liquid (modified motor polymer) used for water proofing with a bonding coat of styrene butadiene latex based liquid (modified cement slurry) used for water proofing upto 5ft. • All depressions, unevenness, surface honeycombing shall be repaired using styrene butadiene latex based liquid (modified motor polymer) used for water proofing with a bonding coat of styrene butadiene latex based liquid (modified cement slurry) used for water proofing. Including cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with water proofing compound tobe finished even and smooth without using extra cement complete all as specified and as directed.
S&F 20mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in as spout pipes to pour out rsidual water out from the treated area complete all as specified and as directed.
M&L for hard core, of broken bricks broken to gauge n exc 63mm for laying sub base of thickness 150mm complete all as specified and as directed.
M&L Cement concrete type D-2 1:4:8 (40mm graded crushed stone aggregate) in foundations, filling and mass concrete in sub base complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B1 with 20mm graded aggregate for laying floor tiles complete all as specified and as directed.
M&L for non skid coloured Ceramic tiles 8 to 10 mm thick in light shade (square/ rectangular) polished, area of each tiles exc 0.11 sqm but not exceeding 0.18 sqm, in floors/Skirting etc. set, jointed and pointed with tile adhesive anti slip white @1.2kg/sqm thickness upto 8 to 10mm (or equivalent) and epoxy material for sealing of tile joints with Epoxy tile grout(or equivalent) to the floor of toilets and bathroom complete all as specified and as directed.
Demolition of cement concrete in and paving (un reinforced) exc. 15 cm. thickness, below or above ground level, including removal of waste from defence land and dumping at a place as specified by civil authorities complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Material and labour for preparation of newly plastered wall surface and applying two coat of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1ratio as per manufacture's instruction and all coats incl primer to be applied with fully automatic airlessspray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed Make: Berger Paints Weathercoat Long Life Flexo / Nerolac Paints excel Total / Asian Paint Apex Ultima Notes for smart periodicals item no 1 to 4: (a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed (b) The contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator before quoting the bids and submit the same alongwith tender & other Documents as mentioned in NIT. (c) Cost of scaffolding at any height shall be included in thequoted rate. (d) Preparation of plastered or unplastered surface or removal of existing treatment by scrapping of walls, chajjas, ceilings, fins, fascias, parapets etc shall be done by using mechanial sander with internal dust extraction system for clean environment certified by the manufacturer. After the prepartion of surface written approval shall be obtained from GE before applying primer and further treatment/coats. Bldg wise stage passing register shall be maintained. e) Finishes ie cement based paint, acrylic water based exterior grade primer, premium acrylic smooth exterior emulsion etc to walls, ceiling, chajjas, fins, fascias, parapets etc shall be applied using airless spray technology and capable of operating single spray gun with a suitable hose length. the spray machine should be of are putted manufacturer with pro-guard technology and capability of tracking pressure as well as paint and primer usage. (f) This equipment shall be certified by approved manufacturer. (g) The accessories for applying the finishes shall be spray in hard to reach areas and penetration of finishes on the surface so as to achieve uniform application and quality surface finish.
Material and labour for complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of external wall/Chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ceiling by filling cracks by Berger Bison Putty / crack fill paste of Berger Paints or equivalent make and make good smoothen surface by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1ratio as per manufacture's instruction and all coats incl primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed. Allow 6-8 hrs to dry the surface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directed
Complete removal of existing roof treatment or roof tile and removing from site to a place outside defence land as specified by civil authorities and clean the surface of roof with water and remove dust complete all as specified and as directed.
M&L for a one component liquid ,solvent free ,cold applied , water-proofing membrane that is highly elastic and UV resistant with 10 years Warranty .ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties: 1.UV resistant ,prevent yellowing and weathering 2.Highly elastic upto 350% and crack bridging 3.Excellent adhesion on porous and non-porous substrates 4. Tensile Strength >10 N/mm2 with GeoTextile fleece 5. Soler Reflective Index (SRI) more then 109-111 ASTM E1980-11 System: First coat:Providing and applying primer over the prepared surface with a liquid water proofing primer specifically designed for use on roofs. Coverage: 0.2kg/m2(with 50% dilution of water) Reinforcement: Geotextile 40 gsm Second coat: Liquid water proofing compound designed to protect roof from water damage. Consumption: 0.5 kg/m2. Third coat: A one component liquid, solvent free, cold applied, water proofing membrane that is highly elastic and UV resistant. Consumption : 0.8 kg/m2. System buildup-1.5kg/sqm with geotextile of 40gsm For accessible roof, tiles with screed/ adhesive may be fixed thereafter.
Providing cement concrete type B-0 1:2:4 (using 12.5 mm graded stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges finished even and smooth without using extra cement . complete all as specified and as directed.
Demolition of brick work or stone masonary built in cement mortar including all quoins , arches, pillar etc but excluding ashlars facing dressed stone work and pre-cast concrete article complete all as specified and as directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6 complete all as specified and as directed.
Brick work with sub class ‘B’ bricks ,straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6 complete , but except bricks , i.e using serviceable bricks obtained from demolition complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) exceeding 1.5 sqm & not exceeding 4 sqm each complete all as specified and as directed.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling and fixing in opening complete all as specified and as directed.
Factory made solid panel PVC door/cup board shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement or stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, suippling and fixing in the frame at site as per specification in SSR Part-I. complete all as specified and as directed.
Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and as directed. Note : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified and as directed.
Pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, keys , hinges lock, lock strike plate etc.made out of 1.25mm thick MS sheet including one shop coat of red oxide zinc chrome primer etc complete all as specified and as directed.
PCC 1:3:6 type C - 1 (using 20 mm graded crushed stone aggregate) as in back filling of chowkats and bed blocks for hold fasts etc complete all as specified and directed.
M&L 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with both face is covered with deco rative face veneer with lipping/frame to match complete all as specified and as directed.
2nd Class hard wood 35mm thick factory made glazed and skelton shutters open rebated and prepared to receive glass , gauze,etc (without sash bars) edges of framing plain , chamfered or rounded. Fitted with cut and mitred beads for securing wiremesh supplied and fitted to chowkats complete all as specified and as directed.
S&F Butt Hinges medium weight cold rolled mild steel of size 100 mm complete all as specified and as directed.
S&F 150 mm size mild aluminium handles cast type anodised complete all as specified and as directed.
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with 2nd class soft wooden beadings complete all as specified and as directed.
S&F 3mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 sqm each. complete all as specified and as directed.
75 mm thick PCC 1:3:6 type C-1, (using 20mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement incl necessary joints complete all as specified and as directed.
Dismantling floor, hearth or wall tiling ,including kotastone, terrazzo topping on walls including cement mortar , bedding (including backing) removing serviceable tiles and rubbish off the premises complete all as specified and as directed.
M&L Non - skid coloured ceramic tiles 7 to 8mm thick joint less (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors laid over and including 15 mm thick screed bed or bedding layer of cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles complete all as specified and as directed.
Glazed ceramic coloured tiles of size 450X 300X 7mm thick as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
M&L for non skid coloured Ceramic tiles 7 to 8 mm thick in light shade (square/ rectangular) polished, area of each tiles exc 0.18 sqm but not exceeding 0.38 sqm, in floors/Skerting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm screed bed or beading layer in CM 1:4 complete all as specified and as directed.
Demolition of reinforced cement concrete ( reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Flat Formwork for rough finished surface of concrete slabs ,shelves slabs etc complete all as specified and as directed.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and as directed.
Reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) for slabs for shelves and similar works complete all as specified and as directed.
Mild steel TMT round bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and as directed..
M&L providing precast cement concrete Reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) for landings cover slab (for man hole) and similar works complete all as specified and as directed.
S&F Plain sheeting 0.56mm thick Aluminium alloy 31000 H4 in stepped flushing on Crumpal joint (measured as the minimum rectangal from which the pieces can be cut) complete all as specified and as directed.
Dismantling water tanksexc 500 ltr but n exc 1000 ltr capacity complete all as specified and as directed.
Rotational moulded polyethlene water storage tanks , triple layered, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of Capacity 1000 litres including over flow , drain out pipe and all accessories complete all as specified and as directed.
Supply and fixing in repair 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe minimum weight 210 gms complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning, threading for prefixing or removal complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections including cleaning, threading for prefixing or removal complete all as specified and as directed.
S&F Steel tubing medium grade galvanised of 20mm bore with all fitting and fixed complete to walls and ceiling or laid in floors. complete all as specified and as directed.
S&F Steel tubing medium grade galvanised of 15 mm bore with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed.
Refixing old galvanised steel tubing of 20 mm bore and connections in new or old position with all fittings fixed complete to walls , ceiling, or laid in floors etc. complete all as specified and as directed.
Refixing old galvanised steel tubing of 15 mm bore and connections in new or old position with all fittings fixed complete to walls , ceiling, or laid in floors etc. complete all as specified and as directed.
Vitreous china squatting pan 'Orissa' pattern long pan size 580 x440 mm white with integral foot rests (excluding cistern and flush pipe), fixed in repair, complete all as specified and as directed.
Vitreous china wash down water closet pan (pedestal pattern) white complete including P or S trap, seat cover and fixing of flushing cistern, brackets, flushing pipe etc fixed in repairs complete all as specified and as directed.
S& F in repair Low level flushing cidtern PVC valveles ,syphonic action type flushing cistern white with inlet valve,float and handle including 32 mm flushing pipe bracket etc complete all as specified and as directed.
Stop cock/ angle valve 15 mm cast cooper alloy of screwed down high pressure with crutch or butter fly handle , screwed with ends for iron pipe or unions fixed in repairs. complete all as specified and as directed.
PVC connections 15mm dia & 600mm long with PTMT nuts complete all as specified and as directed.
PVC connections 15mm dia & 450 mm long with PTMT nuts complete all as specified and as directed.
Stop valve 15mm dia cast copper alloy chromium plated fancy type with long shank and cup (concealed type) srewed both ends for iron pipe or for union and fixed in repair complete all as specified and as directed.
Shower rose of C.P. swival joint of size 125mm for fixing 15mm pipe including fixing to steel pipe or union fixed in repairs complete all as specified and as directed.
Bib taps 15mm dia cast copper alloy fancy type chromium plated, screwed down for iron pipe or for brass ferrule fixed in repair complete all as specified and as directed.
Tubular towel rail, brass chromium plated, 20 mm dia, D type, 60 cm long between Hangs, complete all as specified and as directed.
Dismantling cast iron or reinforced concrete drain pipes of 100mm bore, fixed with walls and taking out of trenches, if required complete all as specified and as directed.
PVC (SWR) floor trap , plain with grating including jointing with solvent cement of 75mm outlet dia complete all as specified and as directed.
PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall including fixing clamps complete all as specified and as directed.
PVC (SWR) bends any radius 110mm bore complete all as specified and as directed.
PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to wall including fixing clamps complete all as specified and as directed.
PVC (SWR) bends any radius 75mm bore complete all as specified and as directed.
PVC(SWR) junction single (single 'T') equal or unequal 110mm bore with access to door complete all as specified and as directed.
PVC(SWR) junction single (single 'T') equal or unequal 75 mm bore with access to door complete all as specified and as directed.
20mm dia ss steel drapery rods in one length per door/window, fancy type (engraved rods), designed & coloured as approved by GE providing with two nos of Bracket powder coated for holding curtain rod and Fiber fancy dome type or wall to wall complete all as specified and as directed.
Preparation of new plaster surfaces of ceiling and applying three coats of white wash on ceiling, complete all as specified and as directed.
Preparation of old plastered or un plastered surface including brooming down or steel wire brushing, scraping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spots, and applying one coat of white wash on ceiling complete all as specified and as directed.
Preparation of new plaster surfaces of walls and applying two coats of oil emulsion distemper over a coat of chalk whiting complete all as specified and as directed.
Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Preparation of old distempered surfaces and applying one coat of oil emulsion distemper on walls complete all as specified and as directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape for cooler stand, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to complete all as specified and as directed.
Taking out carefully copper/aluminium point wiring,Light,fan,socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/floors complete all as specified and as directed.
Taking down distribution boards/wooden board/Metal Clad ,switch fuse units,steel enclosures for MCB of any type and removing from site complete all as specified and as directed.
Taking down existing unserviceable submain wiring any size and making good the disturbed surface complete all as specified and as directed..
Supply, installation, testing, and commissioning of point wiring for one light/fan/bell point controlled by a one-way switch, using 1.5 sqmm FRLS PVC insulated, sheathed, single-core multi-stranded copper conductor cable (1100V grade), drawn through rigid non-metallic PVC concealed conduit (medium grade) of suitable diameter, including 1.5 sqmm FRLS copper earth wire connected to the earth dolly. Wiring shall be terminated in pressed steel sunken boxes with a minimum wall thickness of 1.22 mm (up to 200x300 mm) or 1.63 mm (for larger sizes), complete with 3mm thick Bakelite sheet cover for mounting accessories. Work includes cutting chases, fixing conduits, restoring surfaces with 1:3 cement mortar, and ensuring proper testing on completion, complete all as specified and as directed.
All as per ser item No 90 hereinbefore but for one 3 pin socket outlet 5 Amp Same complete all as specified and as directed.
All as per ser item No 90 hereinbefore but for one 3 pin socket outlet 5 Amp independent complete all as specified and as directed.
All as per Item no 90 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4 sqmm continuous PVC insulated sheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire complete all as specified and as directed.
All as per item No 90above but One light point controlled by two way switch complete all as specified and as directed.
Supply and fix modular type switch, one way 6 Amps , 1 module complete all as specified and as directed.
Supply and fix modular type switch, Two way 6 Amps , 1 module complete all as specified and as directed.
Supply and fix modular type switch, one way 16 Amps, 1 module complete all as specified and as directed.
Supply and fix modular type socket 5 pin, 6 Amps 2 module complete all as specified and as directed.
Supply and fix modular type socket 5 pin, 6 A/16 Amps 2 module complete all as specified and as directed.
Supply and fix in replacement of Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
Supply and fix in replacement Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings , complete all as specified and as directed.
Supply and fix in replacement LED lamp,6500K,900lm in white colour of 10 Watt base cap B-22 with poly carbonate difusser and aluminium heat sink , complete all as specified and as directed.
Electronic fan regulator stepped type,two module with five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fan complete all as specified and as directed.
Supply and fixing LED light fitting 1x20 watt, 220 volts AC decorative box type with driver, holder including LED tube linght connecting up with three core flexible copper conductor cable suitable size from ceiing rose and taking down existing unserviceable luminaire complete all as specified and as directed.
S&F in replacement of LED tube light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC , 6500K colour temprature decorative type with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Taking down carefully the ceiling fan or exhaust fan from its existing position including disconnection of electric connections, lowering and handing over for rewinding as directed at site. After rewinding, reinstallation of the same in position including reconnection, complete greasing of bearings and replacement of bearings if found defective, and testing on load to ensure proper functioning, complete all as specified and as directed. Note: taking down old unserviceable ceiling fan of any type/size from existing location and depositing in MES store, complete all as specified & directed by Engr-in-charge.
Supply, hanging and testing of 1200mm sweep, 230 volts, AC ceiling fans, BEE rated energy efficient ceiling fan conforming to IS:374-2019, having 3 blades alongwith copper wound stator (capacitor start) with minimum air delivery 210 cubic metre per minute, power consumption not more than 50 watt, top speed minimum 370 RPM or higher, speed control by 5 step electronic regulator including capacitor, down rod, canopy, making connection with three core flexiable copper cable of 1.50 Sqmm upto ceiling rose & taking down old unserviceable ceiling fan of any type/size from existing location and depositing in MES store, complete all as specified and as directed.
Exhaust Fan, 300mm(12") sweep, single phase, 230 volts 50 Hz AC,1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site complete all as specified and as directed.
Supply and fix Integral LED Security light luminaire 60W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 including GI 40mm mounting bracket 1.5 metre in length fixed on wall/pole with necessary MS clamps,nuts and bolts and making connection with PVC copper flexible cable 1.5sqmm complete all as specified and as directed.
Supply, installation and testing of water heater storage type (Geyser), single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 50 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, inner tank coating of ferro glass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners - 04 Nos, hot & cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safe plug with all protection features as per OEM design and standard design and standard, complete all as specified and as directed.
Cutting existing steel tubing 15 mm bore for alterations or additions (Each cut measured) complete all as specified and as directed.
Screwing existing steel tubing 15mm for alterations or additions. complete all as specified and as directed.
S & F Tubes medium grade galvanized 15 mm dia with fittings such as socket, bend and fixed complete to walls and ceilings complete all as specified and as directed.
S&F Stop valve/angle valve 15 mm cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of four unions and fixed. complete all as specified and as directed.
S&F Bib tap 15mm chromium plated cast copper alloy with crutch or butterfly screwed down for iron pipe and fixed complete all as specified and as directed.
S&F in replacement of sheet metal steel plug & socket DB SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, surface mounting type complete with one MCB SP, 20 Amps, 10 kA complete all as specified and as directed.
Supply and fix in replacement of Factory made flush shutter type sheet metal enclosures, double door, for MCCB DB load link, Vertical, triple pole and neutral, 6 way IP-43, Suitable for MCCB up to 160A as incommer. complete all as specified and as directed.
Supply and fix in replacement of Thermal magnetic release MCCB 4 pole 415 volt rapturing capacity 16 KA of size 125 amp complete all as specified and as directed.
Supply and fix in replacement of Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 12 ways, complete all as specified and as directed.
Supply and fix in replacement of Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 4 ways, complete all as specified and as directed.
Supply and fix in replacement of MCB SP-06 to 32 Amp, 240 volts complete all as specified and as directed.
Supply and fix in replacement of MCB SPN-32 Amp, 240 volts 50Hz AC supply, complete all as specified and as directed.
Material and labour for sub-main wiring with two runs of single core 10 sqmm PVC insulated (unsheathed) multi-strand copper conductor FRLS cable for phase and neutral, and one run of single core 10 sqmm PVC insulated (unsheathed) multi-strand copper conductor FRLS cable for continuous earth, drawn through and including medium grade 25mm dia ISI marked concealed PVC conduit, complete with conduit fittings and accessories. Work includes cutting chases, pinning in, making good to facing and pointing with cement mortar (1:3), restoring disturbed surfaces, and taking down old unserviceable sub-main wiring, complete all as specified and as directed.
Supply, installation, testing, and commissioning of sub-main wiring using two single-core 4 sqmm FRLS PVC insulated (unsheathed), multi-strand copper conductor cables, along with one single-core 4 sqmm FRLS PVC insulated (unsheathed), solid copper conductor cable as continuous earth wire, drawn through and including ISI-marked 25mm dia concealed PVC conduit (medium grade), complete with all necessary fittings and accessories. The work includes cutting chases, fixing conduits, pinning, restoring surfaces with 1:3 cement mortar, and making good any disturbed areas. It also includes taking down and removing old unserviceable sub-main wiring, complete all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete all as specified and as directed.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT Feeder Pillar Box cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 250 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
MCCB 200 Amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos(Incomer) complete all as specified and as directed.
MCCB 125 Amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 04 Nos (outgoing) (2 Spare) complete all as specified and as directed.
Digital Volt meter .Make Schneider Cat No DM3210 complete all as specified and as directed.
Digital Ammeter meter .Make Schneider Cat No DM3110
Indicator lamp RYB :01 Set, C&S
CT'S 200/5 01 Set Make Legrand
Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and as directed.
Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metres wide and not exceeding1.5 metres in depth and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer complete all as specified and as directed.
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and as directed.
Well burnt old size class 'B' bricks of nominal size 230X115X75 mm abutting each other for cable protection, complete all as specified and as directed.
S & F Steel pipe glavanized grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable including clams with bolts nuts and wasers complete all as specified and as directed.
M&L for cutting/boring/drilling rod/hard standing to a width of 0.2 M and depth not exceeding 1 mtr for laying of GI pipe line for cable protection and making good to match with the existing surface complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 x 6 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete complete all as specified and as directed.
Dismantling and taking out rusted/corroded pipe GI/CPVC of size 20/25/40/50mm bore complete all as specified and as directed.
M & L for replacement of tubing GI "MG" with all fittings laid in floor or trenches including taking out old UNSV pipe of size 50 mm dia complete all as specified and as directed.
M & L for replacement of tubing GI "MG" with all fittings laid in floor or trenches including taking out old UNSV pipe of size 25 mm dia complete all as specified and as directed.
M & L for replacement of gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of size 50 mm bore complete all as specified and as directed.
M & L for replacement of gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm bore complete all as specified and as directed.
Cutting existing 80/100/150 mm GI pipe and inserting GI Tee of size 100x100x50 mm for tapping including necessary earth work and making flange for connection of new 50 mm of GI pipe including complete all as specified and as directed.
Excavation in trenches, n. exc1.5 m wide and n. exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sq m on plan and n. exc1.5 m in depth and getting out in soft / loose soil complete all as specified and as directed.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5m above from the starting point complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed.
GENESIS INDIA (BID ID -3489120)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
tender57_merged.pdf
Tender Documents • 1.90 MB
BOQ_827011.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .