Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.4 L+₹1.2 L (3.32%)Rejected-Finance JOTANKUR TEGHORIJOTEVIRAM PURBA MEDINIPUR | MEDINIPUR EAST | WEST BENGAL | 721627 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹39.8 L+₹4.5 L (12.9%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹48.1 L+₹12.9 L (36.5%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹49.3 L+₹14.1 L (39.9%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
23 Dec 2021, 6:00 pmClosed
GE Kapurthala
Garrison Engineer
Special Repair to OR Md Accn Block No P-38 (Qtr No 01 to 12) at New Mil Stn, Special Repair in Bldg No T-151 at New Mil Stn and Special Repair of Bldg No P-12 (OTM) Single JCO living accn and salvage stores at New Mil Stn under GE Kapurthala
2021_MES_490932_1
GE KPT-65/2021-22
Open Tender
Civil Works
Item Rate
270 days
Kapurthala
As per tender documents
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹99,000
Yes
19 May 2022
27 Nov 2021
25 Dec 2021
27 Nov 2021
23 Dec 2021
4 Dec 2021
Amount
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
M/L for glazed ceramic coloured tiles in vertical surface 300 x200 x 7mm thick set and jointed in neat cement slurry pointed in white or colour cement to match the colour,with 10 mm thick cement screed bed (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06sqm but n.exc 0.11 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbishing and polishing complete including 20mm thick screed bed in CM 1:6 all as specified.
M&L PCC type B-0 (1:2:4) (12.5mm stone graded aggregate), 40mm thick as for receiving top finishing layer of ceramic tiles for sunken portion finished even and smooth etc complete all as specified and directed.
M&L for granite for cooking platform 20mm thick machine cut, bedded and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types including 15mm thick bedding layer in CM 1:6. complete all as specified and as directed by Engr-in-Charge.
Demolition of brick / block masonry built in CM including all quoins, arches, pillars etc and clearing off the premises complete all as specified and directed by Engineer-in-charge.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge.
Use and waste of formwork to chajjas and similar items including edges rough finished complete all as specified and directed by Engineer-in-charge.
M&L for TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending hooking etc & binding with mild steel binding steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-charge.
M&L for TMT bars 5mm dia and over cut to length bent to shape required, including cranking, bending hooking etc & binding with mild steel binding steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-charge.
M & L RCC 1 : 2 : 4, Type B-1 using 20 mm graded stone aggregate as in beams, lintels complete all as specified and directed by Engineer - in - Charge.
Dismantling mild steel work as in roof purlin complete all as specified and as directed by Engr-in-Charge.
Dismantling asbestos cement sheet in roof covering complete all as specified and as directed by Engr-in-Charge.
M&L mild steel rolled section Fe 410-W (Gde-E-250) Quality A as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates complete all as specified and as directed by Engr-in-Charge.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /clading to wall and two corrugated side overlap fixed with self taping screws as specified.
M&L RCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in chajjas etc. complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster on brick work or concrete surfaces incl racking out joints complete all as specified and directed by Engineer-in-charge.
M & L rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick Rendering in CM 1:4 on brick work or concrete surfaces finished even and smooth etc complete all as specified and directed by Engineer-in-charge.
M&L for 5mm thick rendering in CM 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in Ceiling etc complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and applying one coat of Birla white putty to obtain the true line to achieve smooth surface and applying two coats white wash on ceiling complete all as specified and directed by Engr-in-Charge
M&L for preparation of new plastered surfaces of walls and applying one coat of Birla white putty to obtain the true line to achieve smooth surface and applying two coats of oil bound distermper complete all as specified and directed by Engr-in-Charge
M&L for preparation of new plastered surfaces of walls and applying three coats of whitewash complete all as specified and directed by Engr-in-Charge
M & L applying two coats of cement base paint on newly plastered or unplastered wall surface over a coat of cement primer including preparation of surfaces, complete all as specified and directed by Engineer-in-charge.
M & L applying two coats of cement base paint on old plastered or unplastered wall surface including preparation of surfaces, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old plastered surfaces of ceiling and applying two coats of whitewash complete all as specified and directed by Engr-in-Charge
M&L for preparation of old plastered surfaces of walls and applying one coats of oil bound distermper complete all as specified and directed by Engr-in-Charge
Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed by Engineer-in-charge.
M&L 75mm thick PCC 1:3:6 type C2 as in plinth protection finishing the surface even and smooth with out using extra cement complete all as specified and directed by Engineer-in-charge.
M&L PCC (1:4:8) type D2 using 40mm graded aggregate 100mm thick as in sub base complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete 1:5:10 Type E-2 using 40mm graded aggregate as in sub base complete all as specified and directed by Eng-in-charge.
M&L for cement concrete 1:2:4 Type B-0 using (12.50mm graded aggregate), 25mm thick for receiving top finishing layer of ceramic tiles finished even and smooth without using extra cement complete all as specified and directed by Eng-in-charge.
M&L for cement concrete 1:2:4 Type B-0 using (20mm graded aggregate), 75mm thick for flooring finished even and smooth without using extra cement complete all as specified and directed by Eng-in-charge.
Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area not exc 1.50 sqm each complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area exc 1.50 sqm but n. exc. 4sqm each complete all as specified and directed by Engineer-in-charge.
S&F solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and directed by Engineer-in-charge.
S &F factory made solid Panel PVC moulded door shutter, 30mm thick (style) consisiting of frame made out of MS tubes for top and bottom rails. M.S. frame shall covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail, bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawing including fittings complete all as specified and directed by Engineer-in-charge.
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x 60mm complete all as specified and directed by Engineer-in-charge.
M&L PCC 1:3:6 type C2 as in filling of chowkhats complete all as specified and directed by Engineer-in-charge.
S&F factory made 2nd class, hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to received glass, gauge, etc ( without sash bars) edges of framing plain, chambered or rounded, fitted with cut and mitred beads for securing glass , etc but difided into squares with plain chamfered or rounded mirted and rebated sash bars any numbers sizes of members of shutters as specified and directed by Engineer-in -Charge
S&F PVC cupboard frame of size 75mm x 40mm with wall thickness of 5mm made out of extruded 5mm thick Plain/Printed/Prelam PVC sheet reinforced with 15mm x 15mm M.S. square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners and jointed with 2 nos. of 150mm long brackets of 10mm x 10mm M S square tubes. The door frame shall be fixed to the wall using 65/100mm long MS screws through the frame by using PVC fasteners complete all as specified and directed by Engineer-in-charge.
S&F factory made PVC cupboard shutter flush type of 25mm thickness consisting of panel of hollow PVC profile of 12mm x12mm inserted all around the hollow profile section and insert one 10mm x 10mm MS tube in the centre of this section and lipped with 10mm thick(5mm x 2) and 12mm wide on stiles and rails using solvent cement the inner panel shall be laminated with 5 mm thick termite proof waterprrof and fire retardent printed PVC sheet using solvent cement on both sides of panel complete all as specified and directed by Engineer-in-charge.
S &F factory made 2nd class hard wood Plain, framed, panelled shutters 35 mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge.
S&F alumunium hinges for PVC door shutter, size of hinges in 100mm complete all as specified and directed by Engineer-in-charge.
S&F Aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt in 200mm complete all as specified and directed by Engineer-in-charge.
S&F extruded aluminium alloys handles frabicated type anodized of size 150mm long complete all as specified and directed by Engineer-in-charge.
S&F 300mm long mild steel sliding door bolt plate type stove enamelled black and bright bolt not less than 12mm dia including a minimum of 6 nos of nuts and bolts all as specified.
S&F mild steel barrel tower bolt, stove enamelled black, with bright bolt of 150mm size complete all as specified and directed by Engineer-in-charge.
S&F mild steel pressed handle , oval type stove enamelled black of size 125mm complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new wooden surface exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint over red oxide primer all as specified and directed by Engineer-in-Charge.
S & F steel window 1.25mm thick Box type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises of glass pane glazed Skelton shutter and wire mesh glazed Skelton shutter of ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter: (a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Glass, wire mesh and painting shall be measured and paid separately under appropriate item (ii) Irrespective of whatever shown on drgs, MS gills shall be of 12mm dia MS square bar complete all as specified and directed by Engineer-in-charge.
S&F 4.00mm thick plain glass in squares n exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed by Engineer-in-charge.
Supply and fix steel ventilators fixed type with glazing bars etc complete all as specified and directed by EIC.
S&F 4.00mm thick figured glass, pinhead type in squares n exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed by Engineer-in-charge.
S&F for stainless steel wire cloth 0.56mm nominal dia of wire and avarage width of aperture 1.00mm and fixed with tinned tacks/screws with bolts incl leaping wooden complete all as specified and directed by Engineer-in-charge.
M&L for framed work such as grills gratings etc with ends of bars shouldered and or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings framed work of water tanks and similar work complete all as specified and directed by Engineer-in-charge.
S&F in repairs of size 300mm MS ordinary rat rail rod pattern helical springs including roller and roller plate complete all as speicified
Taking down GI tubing & connection 15mm dia laid in floor / trenches or fixed to walls complete all as directed by Engineer-in-Charge.
S&F GI tubing 15mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
Taking down GI tubing & connection 20mm dia laid in floor / trenches or fixed to walls complete all as directed by Engineer-in-Charge.
S&F GI tubing 20mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F in repairs 15 mm bore CP bib taps fancy type cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs 15mm dia stop valve, CP cast copper alloy with crutch or butterfly handle. Screwed down high pressure, screwed both ends for iron pipe and fixed complete all as directed by Engineer-in-charge.
Supply and fix in repairs vitreous china squatting pan Orissa pattern wash down water closet of size 580x440 mm, white, with integral foot rests complete fixed in repairs with P or S trap, PVC flushing cistern low level of Make 10 ltrs capacity including brackets for flush tank, PVC flush pipe and all necessary fittings etc complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Nahani trap with grating and diameter of outlet 100mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-charge.
S&F in repairs fancy type chromium plated stop valves with long shank and cup (concealed type) cast copper alloy screweddown high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore fof size 15mm complete all as specified and directed by Engineer-in-charge.
Supply and fix for vitreous china ware wash basin white, flat back size 550 X 400mm including 15mm dia pillar tap chromium plated, CP waste coupling, waste fittings, union and waste pipe 32mm dia or required length and all necessary inlet, out let connections complete all as specified and directed by Engineer-in-charge.
S&F in repairs shower rose of chromium plated any colour or fixing with 15mm pipe (minimum weight 40gm) complete all as specified and directed by Engineer-in-charge.
S&F shelf of PTMT fixed with and including chromium plated brass screws and wooden plastic cleats(min. weight 300gm) complete all as specified and directed by Engineer-in-charge.
S&F in repair anodised aluminium alloy curtain rail chromium plated with fixing brackets, stops, roller etc as specified and directed complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) in ground floor n.exc 15 cm thick below or above ground level complete all as specified and directed by Engineer-in-charge.
M&L for applying evenly a tack coat of industrial bitumen 85.25 @ 1.20 Kg/sqm including cleaning surfaces complete all as speciified and as directed by Engineer-in-Charge.
M&L for rendering 10mm thick CM(1:3) on concrete surfaces even and smooth with WPC complete all as specified and directed by Engineer-in-charge.
Cutting chases pinning in brick/stone/blocks masonary in making good to facings where required and pointing in CM (1:3) to ends or eges of steps, cills, sun shades, shelves, lintel etc and cutting chases for concealed water tubing or etc and making good, complete all as specified and directed by Engineer-in-charge.
S& F in repairs Ball valves 20mm high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210 gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by Engineer-in-charge.
Dismantling of brick tiles or terracing tiles laid bedded and pointed in cement mortar in single layer on roofs complete all as specified and directed by Engineer-in-charge.
Demolition of mud in roof any thickness including plastering & leeping removed complete all as specified and directed by Engineer-in-charge.
Material and labour for 40 mm thick Cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in PCC padding over roof slab complete all complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by Engr-in-Charge.
Preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer confirming to IS :3384-1965 @ 0.40kg/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymericweighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers laid with torching application to the surface over a coat of hot blown bitumen 85/25 @1.20 Kg/Sqm complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:3 with jointing and pointing in cement mortar (1:3) mixed with 5% crude oil by weight of cement complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:3 with jointing and pointing in cement mortar (1:3) mixed with 5% crude oil by weight of cement but except brick tiles complete all as specified and directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes including all fittings as specified and directed.
S&F 110 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as directed by Engineer-in-Charge.
S&F 75 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as directed by Engineer-in-Charge.
M&L in repairs for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches and fixed in floors complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC(SWR) floor trap with grating and diameter of outlet 75mm including jointing to waste pipe fixed with solvent cement complete all as specified and directed.
S&F 75 mm PVC (SWR) bend complete all as directed by Engineer-in-Charge.
S&F 110 mm PVC (SWR) bend complete all as directed by Engineer-in-Charge.
S&F 110mm PVC (SWR) junction single,(single T) equal or unequal complete all as directed by Engineer-in-Charge.
S&F 110mm PVC (SWR) junction single,(double T) equal or unequal complete all as directed by Engineer-in-Charge.
S&F 20mm dia aluminium chromium plated tubular towel rails,D type,60cm long between flanges, complete all as specified and directed by Engineer-in-charge.
Demolition and breaking up 200mm bore dia drain pipe (salt glazed ware, AC or reinforced cement concrete) set in CM complete all as specified and as directed by Engr-in-Charge.
Material & Labour for for salt-glazed stoneware drain pipes 200mm dia (internal diameter of pipe) Grade "A" laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge.
M&L for concrete bed to drain pipes 200mm bore in cement concrete (1:3:6) type D-2 (using 20mm graded stone aggregate) including packing under and haunching against sides of pipe after they are laid and tested complete all as specified and directed.
Excavation in trenches n. exc 1.5 m wide & n.exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and as directed by Engr-in-Charge. (Note : Also for laying of cables and getting out including trimming of sides)
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n.exc. 50 m and depositing where directed at a level n exc.1.5m as in soil complete all as specified and as directed by Engr-in-Charge.
Dismantiling water tank PVC 500 Ltrs and removing from site complete all as specified and directed by Engineer-in-charge.
S&F rotational moulded polythelene water storage tanks cylindircal water tank for hoisted and fixed in postion of 500 ltrs capcity including fittings and as directed by Engr-in-Charge
Dismantiling water tank PVC 1000 Ltrs and removing from site complete all as specified and directed by Engineer-in-charge.
S&F rotational moulded polythelene water storage tanks 1000ltrs capacity with threaded lid white colour hoisted and fixed in postion incl fittings and as directed by Engr-in-Charge
S&F gunmetal globe and gate valve with iron wheel screwed both and for iron pipe 20mm bore size fixed in repairs complete all as specified and directed by Engineer-in-charge.
S& F in repairs Ball valves 20mm high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210 gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by Engineer-in-charge.
Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge
Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FR) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :-
(a) One light point controlled by one, one way switch
(b) One fan point controlled by one, one way switch
(c) One socket outlet 3 Pin, 5 Amp on independent board
(d) One socket outlet 3 Pin, 5 Amp on same board.
(e) One bell point controlled by one bell push
(f) One light point controlled by two 2 -way switches
M&L for point wiring with 4.00 Sq mm single core multi-stranded copper conductor PVC (FR) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.50 Sq mm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on Independent board.
M&L for point wiring with 6.00 Sq mm single core multi-stranded copper conductor PVC (FR) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 6 Sq mm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on Independent board.
S&F switch piano flush type single pole one way 5 Amp (ISI Marked) Make - SSK/Anchor/Cona
S&F switch piano flush type single pole one way 6 Amp (ISI Marked) Make - SSK/Anchor/Cona
S&F switch piano flush type single pole one way 15 Amp (ISI Marked) Make - SSK/Anchor/Cona
S&F Bell push flush type single pole one way 5 Amp (ISI Marked) Make - SSK/Anchor/Cona
S&F socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) Make - SSK/Anchor/Cona
S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) Make - SSK/Anchor/Cona
S&F switch piano flush type single pole two way 5 Amp.Make - SSK/Anchor/Cona
M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) Make - SSK/Anchor/Cona
M&L for bell multi music type, AC 230 Volts, single pole (ISI Marked)
Taking down old unserviceable flourescent tube light fitting 36/40 watt fluorescent tube light fittings direct to walls or roof as ordered and disconnecting electrically with the electrical system and all materials required for the same. The rates also include making good the same to match with the existing surface.
Supply, installation, testing and commissioning of 20 watt 4 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed Make Polycab Cat part No PCGLB AX 2060 or equivalent in Philips/Bajaj/C&S electric/Surya
Taking down old unserviceable sub main wiring 6/ 4.00 Sqmm 1100 volts grade two runs of single core PVC insulated, unsheathed copper condutor, including taking down casing capping/PVC conduit.
Taking down unserviceable MCB’s and supply & fix following type/rating MCB’s including necessary connection as under:-
(a) S & F of MCB, 10 to 32 Amp, SP, 240 Volt Make - Legrand/Schneider-Acti 9/Siemens-Betagard
(b) S&F of MCB, 25 to 32 to Amp, SPN, 240 Volt Make - Legrand/Schneider-Acti 9/Siemens-Betagard
(c) S&F of MCB, 6 to 10 to Amp, SPN, 240 Volt Make - Legrand/Schneider-Acti 9/Siemens-Betagard
Taking down old unserviceable sub main wiring 6/ 4.00 Sqmm 1100 volts grade two runs of single core PVC insulated, unsheathed copper condutor, including taking down casing capping/PVC conduit.
M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Three run of 6.00 Sqmm cable and one run of PVC Conduit shall be measured & paid as one unit.)
Taking down old unserviceable lamp holder and S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.including LED lamp 09 Watt..
Taking down old Ceiling fan and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
Taking down old unserviceable bulkhead fitting & supply & fix bulkhead fitting decorative ceiling/wall mounted BULK HEAD with engineering plastic housing and top frame with opal PMMA diffuser suitable for 1 X 06 watt LED Blub including 1 No of 06 watt LED of cat part No CG80IB6WLED of C&S electric or equivalent in model of Philips or Bajaj complete all as specified and directed by Engineer-in-Charge,
Taking down old unsv DB and supply and fixing factory made sheet metal enclosure double door distribution board class IP-43 with 200 Amp rated copper bus bar 240 volts 8 way single pole and neutral link complete all as directed by Engineer-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.
(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.
(iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.
(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Taking down old unserviceable regulator & supply & fix electronic type fan regulator stepped type on existing phenolic laminated sheet etc. suitable for ceiling fan.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric cable (heavy duty) 1100 volts grade with standard aaluminium conductor of size 25 Sqmm 3.5 core
Supply, install, testing and commissioning of LT panel size 800 mm x 600 mm x 150 mm enclosures cubical weather and vermin proof totally enclosed made out of 1.6 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front openable and PVC acrulic glass cover suitable size for checking of meter reading without opening door with locking arrangement incl inner shutters for mounting switch gear etc, suitable arrangement for fixing of electrical meter and SPN 40 to 63 Amp including pre wiring from Bus bar to Meter and Meter to MCB SPN (for pre wiring use 6.00 Sqmm Single core copper cable and suitable size of lugs for connecting from Busbar to meter and meter to MCB SPN)including bottom gland plate with sufficient numbers of circular cable entry holes, including prewired complete as per drawing with masonary work for fixing in wall duly powder coated with comprising of the following :-
INCOMING :-
(i) MCCB 63 Amps FP, 415 Volt 25 KA adjustable thermal & fixed magnetic setting Ics = 100% = 01 No of Make : Havells/C&S electric/Legrand/Siemens.
(ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three.
(iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos
(iii) Aluminium bus bar 200 Amps capacity with bus bar supports, DMC/SMC insulators of CPRI approved of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos.
OUT GOING
(i) MCB 32 Amp,415 Volt,10 KA, Single pole and neutral -04 No Make : Legrand/Siemens/Schnedier
(ii) S&F single phase electronic energy meter with LCD display of rating 5-30 Amp class 1.0, 240V 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire complete all as specified and directed by Engr-in-Charge.Make-HPL - 04 Nos
Taking down old unsv GI pipe & Supply and fixing 50 mm dia GI tubing light grade complete with all fittings (ISI Marked) lain in trenches/fixed complete to wall and ceiling or laid in floors as specified.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with length of bricks perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge.
M/s S B Construction Company
KAMAL AGGARWAL
Motorway Constructions
Gurjit const co
COSMO BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .