Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAdmitted-Finance | ₹13.9 L | L1 | Admitted-Finance |
| 2 | L2₹15.4 L+₹1.5 L (10.5%)Admitted-Finance | ₹15.4 L+₹1.5 L (10.5%) | L2 | Admitted-Finance |
| 3 | L2₹15.4 L+₹1.5 L (10.5%)Admitted-Finance | ₹15.4 L+₹1.5 L (10.5%) | L2 | Admitted-Finance |
| 4 | L3₹15.5 L+₹1.6 L (11.6%)Admitted-Finance | ₹15.5 L+₹1.6 L (11.6%) | L3 | Admitted-Finance |
| 5 | L4₹15.6 L+₹1.7 L (12.3%)Admitted-Finance | ₹15.6 L+₹1.7 L (12.3%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | The Trikuta Engineer L8 | M/S R. V ENTERPRISES L2 | M/S TRANS TECH ENGINEERS L3 | M/S SWASTIC ELECTRICAL CONTRACTOR AND SUPPLIERS L2 | JASMEET SINGH L1 | M/S DAYAL BUILD TECH L7 | M/S RATHER CONSTRUCTIONS AND TRADERS L4 | M/S APR CONSTRUCTIONS L5 | M/S NEW TRIKUTA TECHNOCRATES L9 | M/s MAHASHAKTI ELECTRICAL WORKS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Augmentation of 11/0.433kV, 400 KVA to 630 KVA , 3-phase Distribution Substation | |||||||||||||
| 1.01 | Supply, Installation & commissioning of 11/0.433 KV, 630 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Copper Wound) alongwith LV Cable Box having detachable Alumnium Gland plate including Transportation (As per latest amendments and IS) Note: Dismantling and Write Back of dismantled 400 KVA Distribution Transformer and allied material to Divisional store at Miran Sahib which includes labour and mechanical carriage charges involved . | 1 | No | 14,00,000 ₹14,00,000 | 12,85,000 ₹12,85,000 | 11,53,800 ₹11,53,800 Lowest | 12,85,000 ₹12,85,000 | 13,36,000 ₹13,36,000 | 13,50,000 ₹13,50,000 | 13,00,000 ₹13,00,000 | 12,00,000 ₹12,00,000 | 14,25,000 ₹14,25,000 | 12,87,000 ₹12,87,000 |
| 1.02 | Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface. | 2 | No | 20,000 ₹40,000 | 14,000 ₹28,000 | 20,000 ₹40,000 | 14,000 ₹28,000 | 11,000 ₹22,000 Lowest | 15,000 ₹30,000 | 15,000 ₹30,000 | 19,000 ₹38,000 | 18,000 ₹36,000 | 19,000 ₹38,000 |
| 1.03 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 1 | Set | 7,000 ₹7,000 | 7,500 ₹7,500 | 12,000 ₹12,000 | 7,500 ₹7,500 | 3,000 ₹3,000 Lowest | 6,500 ₹6,500 | 7,000 ₹7,000 | 6,000 ₹6,000 | 4,000 ₹4,000 | 7,000 ₹7,000 |
| 1.04 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type | 1 | Set | 12,000 ₹12,000 | 10,500 ₹10,500 | 14,000 ₹14,000 | 10,500 ₹10,500 | 3,000 ₹3,000 Lowest | 6,000 ₹6,000 | 9,000 ₹9,000 | 10,000 ₹10,000 | 10,000 ₹10,000 | 9,000 ₹9,000 |
| 1.05 | Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | 7,000 ₹7,000 | 6,500 ₹6,500 | 8,500 ₹8,500 | 6,500 ₹6,500 | 3,000 ₹3,000 Lowest | 7,500 ₹7,500 | 4,000 ₹4,000 | 6,000 ₹6,000 | 4,200 ₹4,200 | 6,000 ₹6,000 |
| 1.06 | Providing & Fixing of Single Phase PVC Cable 630 mm² ,1.1K V Grade, PVC Insulated Stranded Un-Armoured FRLS type alongwith Al. Thimbles for 630 mm² Cable termination with four colored PVC Tapings to distinguish the LT Phases and the Neutral. (2 Ckt) | 88 | Mtr | 1,000 ₹88,000 | 750 ₹66,000 | 1,159.09 ₹1,02,000 | 750 ₹66,000 | 100 ₹8,800 Lowest | 1,250 ₹1,10,000 | 800 ₹70,400 | 1,100 ₹96,800 | 1,200 ₹1,05,600 | 1,250 ₹1,10,000 |
| 1.07 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | 3 | No | 3,000 ₹9,000 | 3,500 ₹10,500 | 5,000 ₹15,000 | 3,500 ₹10,500 | 300 ₹900 Lowest | 2,000 ₹6,000 | 3,000 ₹9,000 | 3,000 ₹9,000 | 1,500 ₹4,500 | 3,500 ₹10,500 |
| 1.08 | Providing & Fixing of LT Distribution Box with 2No 630Amp Triple Pole MCCB for incomer with adjustable overload release of (80-100%) & switch fuse unit for Out Going 2No Ckts. including Busbar arrangements for Phases & Neutral of EC Grade Aluminium,PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc. | 1 | No | 1,00,000 ₹1,00,000 | 60,000 ₹60,000 | 95,000 ₹95,000 | 60,000 ₹60,000 | 5,000 ₹5,000 Lowest | 1,00,000 ₹1,00,000 | 70,000 ₹70,000 | 1,20,000 ₹1,20,000 | 1,25,000 ₹1,25,000 | 1,05,000 ₹1,05,000 |
| 1.09 | Construction of Concrete-Cement (1:2:4) Platform (8x8x3) & 3feet below ground level ) for 630 KVA SubStation along with the mesh fencing (with two coats of metal oxide & Al. Paint) around the Periphery. (complete Job) | 1 | No | 75,000 ₹75,000 | 60,000 ₹60,000 | 1,05,000 ₹1,05,000 | 60,000 ₹60,000 | 10,000 ₹10,000 Lowest | 65,000 ₹65,000 | 60,000 ₹60,000 | 75,000 ₹75,000 | 70,000 ₹70,000 | 95,000 ₹95,000 |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
26 May 2026, 4:00 pmClosed
Executive Engineer Electric Division-II JPDCL
Executive Engineer Electric Division-II JPDCL
Rate contract for Augmentation of 400 KVA to 630 KVA Distribution Substations at different locations within the jurisdiction of Electric Division-II Jammu on turnkey basis during the Financial Year 2026-27
2026_PDD_309516_1
e NIT 18 of 2026-27
Open Tender
Electrical Works
Turn-key
45 days
Jammu
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
Executive Engineer Electric Division-II JPDCL
₹48,000
11 Jun 2026
8 May 2026
27 May 2026
8 May 2026
26 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Augmentation of 11/0.433kV, 400 KVA to 630 KVA , 3-phase Distribution Substation | |||||
| 1.01 | Supply, Installation & commissioning of 11/0.433 KV, 630 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Copper Wound) alongwith LV Cable Box having detachable Alumnium Gland plate including Transportation (As per latest amendments and IS) Note: Dismantling and Write Back of dismantled 400 KVA Distribution Transformer and allied material to Divisional store at Miran Sahib which includes labour and mechanical carriage charges involved . | 1 | No | - | - |
| 1.02 | Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface. | 2 | No | - | - |
| 1.03 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 1 | Set | - | - |
| 1.04 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type | 1 | Set | - | - |
| 1.05 | Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | - | - |
| 1.06 | Providing & Fixing of Single Phase PVC Cable 630 mm² ,1.1K V Grade, PVC Insulated Stranded Un-Armoured FRLS type alongwith Al. Thimbles for 630 mm² Cable termination with four colored PVC Tapings to distinguish the LT Phases and the Neutral. (2 Ckt) | 88 | Mtr | - | - |
| 1.07 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | 3 | No | - | - |
| 1.08 | Providing & Fixing of LT Distribution Box with 2No 630Amp Triple Pole MCCB for incomer with adjustable overload release of (80-100%) & switch fuse unit for Out Going 2No Ckts. including Busbar arrangements for Phases & Neutral of EC Grade Aluminium,PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc. | 1 | No | - | - |
| 1.09 | Construction of Concrete-Cement (1:2:4) Platform (8x8x3) & 3feet below ground level ) for 630 KVA SubStation along with the mesh fencing (with two coats of metal oxide & Al. Paint) around the Periphery. (complete Job) | 1 | No | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
sbd18.pdf
Tender Documents • 1.16 MB
BOQ_1001981.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .