Loading…
Loading…
Tender Value
₹52.0 L
EMD Value
₹1.0 L
Closing Date
31 Aug 2026, 2:30 pm7d left
CENTRE DIRECTOR
Homi Bhabha Centre for Science Education V. N. Purav Marg, Mankhurd, Mumbai 400 088.
Roofing Shed Work on Main Building Canteen Terrace and NIUS TV Room Terrace at Homi Bhabha Centre for Science Education
2026_DAE_921452_1
HBC/PUR/PUBLIC TENDER 43/2026-27
Open Tender
Civil Works
Works
150 days
HBCSE-MANKHURD, MUMBAI
As per tender documents
5 documents required · 5 mandatory
₹0
₹1.0 L
Homi Bhabha Centre for Science Education
10 Aug 2026
10 Aug 2026
1 Sept 2026
10 Aug 2026
31 Aug 2026
19 Aug 2026
18 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Designing , drawing, providing, fabricating and erecting Mild Steel work in Roof trusses and framework: Designing, drawing, providing, fabricating and erecting at site of work the tubular hot finished steel structure (shed) as per approved design, drawing and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of breaking the brick bat coba till mother slab for bottom plate fixing, steel tubular trusses, tubular columns purlins, tie runners, Stainless Steel foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive epoxy primer and two coats of epoxy painting of approved quality and shade etc. complete. Tentative Mild Steel (MS) section sizes to be used for roofing work (as per design approved by EIC):-
a) Trusses: MS square/ rectangular pipes (75 X 75 X 2.6mm) of hot finished welded type tube member of size as per site requirement.
b) Vertical columns: MS square pipes (100 X 100 X 3mm) of hot finished welded type tube size as per site requirement. Column spacing should be at equidistant @ approx. 7.00m c/c 3 nos. of columns to support truss, (2 at both ends and 1 at centre)
c) Purlins: MS square/ rectangular pipe (50 X 50 X 2.6mm) of hot finished welded type tube, spacing @ approx. 1.20m c/c.
e) Foundation Plate: To be fixed over mother slab (after chipping of top brick bat coba layer) having plate size as per site requirement but min.12 mm thick, including chemical grouting over plates.
f) Stainless Steel foundation bolts: Bullet fastener of M/s. Hilti or approved equivalent make of size 150x12 mm.
i) Painting: Painting over new MS structure with one coat of zinc chromate primer and one to two coats of epoxy of approved make.
NOTE: 1. The truss design to be submitted by the contractor should be as per IS specifications and considering the live load, dead load, solar panel load (wherever instructed by EIC) and wind pressure on the structure, complete. (Drawing should be signed by any reputed structural designer.) 2. MS framework and roofing is required to be done over all terrace areas including the area over mumty room, water tanks and lift machine room, with proper gutters and down take pipe drain system. | 17 | MT | - | - |
| 2 | Roofing colour coating HI profile PIR sheet: Supply of Sandwich PIR Roof Panels of following specifications: JSW Pre-painted Galvalume (PPGL) metal sheets
Panel Thickness: 50 mm
Panel Type: Sandwich PIR Roof Panel
Colour: Off White
Top Skin: 0.50 mm TCT PPGL Sheet – Trapezoidal Profile
Bottom Skin: 0.30 mm TCT PPGL Sheet – Baby Rib Profile
Steel Make: JSW Colour Coated PPGL Sheet
Core Material: PIR (Polyisocyanurate) Foam
Core Density: 40 ± 2 kg/m³
Fire Rating: Class B
Panel Length: Custom Made to Order
Foaming Chemicals: Polyol, Isocyanate (ISO), Pentane & Catalyst AND Installation of Sandwich PIR Roofing System including unloading, handling, lifting, positioning, alignment and installation of 50mm Thick Sandwich PIR Roof Panels over the completed MS structural framework. The scope includes laying of panels in the approved orientation, maintaining proper end and side laps, fixing with self-drilling epoxy coated fasteners complete with EPDM washers, stitching of panel joints, installation of ridge caps, end caps, side flashings, corner flashings, apron flashings, eave flashings, stitching screws, closure profiles, foam fillers, butyl sealant tape, silicone sealant, and all necessary accessories to ensure a weatherproof and leak-proof roofing system. Final handover of the completed roofing system in accordance with approved drawings and standard engineering installation practices etc. complete as directed by EIC. | 1,320 | Sqm | - | - |
| 3Providing and Fixing of PVC Gutters: Supply & Installation of PVC Rainwater Gutter System comprising uPVC Gutters, Gutter Brackets/Clamps, Joint Connectors, End Caps, Outlet Nozzles, Sealant, and all necessary fixing accessories required for complete installation. The scope includes cutting, alignment, joining, fixing, and installation of the gutter system with the required slope for efficient rainwater collection and discharge, complete in all respects as per approved drawings and standard installation practices. | |||||
| 3.1 | PVC pipe of 150mm dia | 150 | Rmt | - | - |
| 3.2 | PVC pipe of 100mm dia | 50 | Rmt | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
BOQ_968330.xls
BOQ • 0.33 MB
Tender.pdf
Tender Documents • 0.80 MB
Addendum1.pdf
PDF • 1.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].