Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC | ₹33.7 L Quoted ₹33.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹35.0 L+₹1.1 L (3.30%)Rejected-AOC | ₹35.0 L+₹1.1 L (3.30%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹36.7 L+₹2.9 L (8.49%)Rejected-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹36.7 L+₹2.9 L (8.49%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹38.3 L+₹4.5 L (13.2%)Rejected-AOC SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | ₹38.3 L+₹4.5 L (13.2%) | L4 | Rejected-AOC Rejected |
Tender Value
₹39.5 L
EMD Value
₹78,920
Closing Date
30 Jan 2020, 6:00 pmClosed
GE Gomantak
GE Gomantak, Vasco Goa
Addn Altn and special repairs to bldg P 24 ( Tradesman shop Battery charging room and civilian recreation hall) at NTRW Goa, Provn of POL store at INS Gomantak and Special repair to fire station bldg No P 103 at INS Gomantak under GE Gomantak
2020_MES_311686_1
8109/E8
Open Tender
Support/Maintenance Service
Works
270 days
Vasco Da Gama
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Gomantak
₹78,920
Yes
23 Nov 2021
3 Jan 2020
31 Jan 2020
3 Jan 2020
30 Jan 2020
13 Jan 2020
Amount
Taking down chowkats or frames not exc. 1.5 sq.m. each with shutters (without taking off shutters from the frames)
Taking down chowkats or frames exc. 1.5 sq.m. and n.exc 4 sqm each with shutters (without taking off shutters from the frames)
Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each and refixing in the same opening after repair work.
S&F solid PVC moulded door shutter with particle board core, 28 to 30mm thick ( stiles) with 2 raised panels designed with 2mm thick moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face complete all as specified.
S & F 2nd class hard wood plain solid straight chowkats frames wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified.
S & F 35 mm thick plain framed panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube complete all as specified.
S & F Aluminium, anodised barrel tower bolts of extruded section and fixed complete. Length of bolt 150mm
S & F Extruded anodised aluminium alloy handles, fabricated type, of 150mm long.
S & F Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed of 300mm long
S & F stainless steel Butt hinges, 100mm long, medium weight, complete all as specified.
M&L preparation of NEW wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over coat of pink primer.
M&L preparation of old wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint.
S&F powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. Note: frame shall be fixed with 08 Nos 120mm length screw with rawal plug.
Supply and fixing Aluminum powder coated deco grill make DG 104 (10 mm thick section ) with frame of section not less than 0.136 kg/rm
S&F 4mm thick sheet glass,ordinary qauality and glazing with oil putty in square n exc 0.50 sqm in each pane
S&F aluminium alloy anodised wire mesh of 0.45 mm nominal dia of wire and avg width of aperture 1.40 mm and fixed with aluminium wire staples.
Taking up or down 20mm dia steel tubing and connections,fixed to wall /floor
Taking up or down 25 mm dia steel tubing and connections, fixed to wall /floor
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in Stone, concrete block or slab /walls
Dismantling water tanks and removing to store of capacity exc 1000 & n exc 2000 ltr.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 1000 Ltrs Capacity
S & F 25 mm dia Ball brass valves, high pressure, with polythene float and fly- nut com-plete, scre-wed for iron pipe or brass ferrule.
S & F PVC valveless, syphonic action type, flushing cistern, 10 litres, low level, white, with inlet, ball valve, float and handle including brackets and connections to pipes and fixing of chain and pull, or level, if any fixed in repairs.
S & F in repairs Flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern
S & F in repairs Vitreous China wash basin, white, flat back, size 630x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets.
S & F Pillar taps, 15mm dia, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs
S & F CP stop cock/angle cock 15mm dia, fancy type with capston heads screwed both ends for iron pipe or for unions and fixed
S&F Stop valves 15 mm bore fancy type, CP with long shank & cup (conncelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions
S & F Bib taps, 15mm dia, cast copper alloy, fancy type, with capston head, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs.
S & F Swivel shower of PTMT any colour for fixing with 15mm pipe .(Minimum weight 40gms) fixed in repair.
S & F shower arm 15mm size,195mm long with bend of 45degree with flange of PTMT any colour. (Minimum weight 40gms)fixed in repair.
S & F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats .(Minimum weight 190gms)fixed in repair
S & F PVC connections 15 mm size with PTMT nuts of length 60 cm fixed in repair.
M&L Cast iron nahani trap, with steel grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
S & F in repairs vitreous China bowl urinal flat back of size 465 X 355 white with grating and union for discharge pipe fixed in repair including waste pipe complete all as directed by Engineer-in-Charge
S & F in repairs vitreous china squating pan, Orissa pattern of size 580 X 440 mm white with integral foot rests all as directed.
M & L 40 mm dia high density polyethylene pipes laid in floor/trenches/ waste pipe of wash basin/spout pipe etc. complete all as specified.
Dismantling of CI drain pipe, 100 mm dia, jointed in cement mortar and taking out of trenches all as directed by Engr-in-Charge
Dismantling of CI drain pipe, 75 mm dia, jointed in cement mortar and taking out of trenches all as directed by Engr-in-Charge
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls
Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10cm in width and setting in mortar CM 1:4,type C1 1:3:6 using 20mm graded aggregate complete
M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth protection.
Taking down cement plaster on brick or stone wall etc., including racking out joints, hacking for key, scrubbing down with water, etc complete
Material and labour rendering cement plaster 10 mm thick in CM 1:6 on fair faces of brick/concrete faces (internal walls) finished even and smooth without using extra cement.
Material & Labour for rendering in CM 1 : 4 (10+5)=15mm thickness on brick/cement/stone surfaces and finishes the surface even and smooth with out using extra cement including mixing with liquid WPC on top 5mm thick only (Note :- Water proofing compound shall be measured and paid separately)
M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) as in ceiling surfaces
Material & Labour two coats of acrylic emulsion extenior paint (anti fungal painting-APEX or Equivalent) over a coat of acrylic amulsion primer including preparation of new concrete/plastered surface of any description all as specified and directed by Engr-in-Charge.
Material & Labour one coats of acrylic emulsion extenior paint (anti fungal painting-APEX or Equivalent) including preparation of old treated concrete/plastered surface of any description all as specified and directed by Engr-in-Charge.
Material & Labour for providing two coats of oil-bound distemper over a coat of alkali-resistant primer on new plastered surfaces including necessary preparation to surfaces complete all as specified and as directed
M&L applying three coats of white wash on new Ceiling surface including preparation of surface.
M&L applying two coats of white wash on old Ceiling surface including preparation of surface.
Material and labour for preparation of new surface of wall and applying two coat of white wash, complete all as specified and as directed by Engineer-in-Charge
Material and labour for preparation of old surface of wall and applying two coat of white wash, complete all as specified and as directed by Engineer-in-Charge
Demolition Cement concrete (unreforced) in ground floors and pavings n exc 15cm thickness (below or above ground level)
Material & Labour for 25 mm thick PCC type B-0, 1:2:4 (12.5 mm graded aggregate) as in levelling course in floors
M & L screed bed or bedding layer or mortar 20mm thick for laying floor finishes in CM (1:4).
M & L 20 -22 mm thick kota stone, machin cut kota stone slab flooring over cement screed base laid in CM, and jointed in neat cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete (mirror polished).
M & L Kota stone slab 15-18mm thick in riser of steps, skirting, dado and pillar, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete (mirror polished).
M & L Granite (of any type) work 15-20mm (table rubbed and polished)in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises.
M & L Glazed ceramic tiles in vertical surface 300x200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tiles.
M & L Rendering a backing coat of 10mm thick in CM 1:4 to receive skirting/backing coats of tiles.
M & L Non-skid coloured ceramic tiles 7 to 8 mm thick area of each tiles exc 0.6 sqm but n exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match.over 15mm thick screed bed in CM 1:4.
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished even & smooth (without using extracement) mixed with WPC 200ml per bag of cement or as per manufacturer's instruction. (WPC shall be measured and paid for separately)
Removing of APP treatment from roof surface cleaning of roof tops including removing the existing treatment by brooming down with steel wire brushing scrapping down with steel scrapper and roughening the existing surfaces to receive plaster and Supply & Laying water proofing treatment using 4mm thick APP modified membrane consisting five layer membrane with features as specified, weighing not less than 4.5 kg per Sqnm laid over a coat of cold applied bituminous primer @ 0.20 Kg per sqm by torching the membrane including sealing the over lap while torching with 100mm on length side and 100mm wide side as per manufactorer instuctions including joints and changes in direction the curved with cement mortar 1:3 mixed with SBR Latex @ 200 Ml/bag of cment cured well before laying of membrance all as per manufacturer instructions and to the satisfaction of Engineer -in-charge including two coats of bituminous aluminium paint. Note (i) irrespective of lap the net covered area will only be measured for payment (ii) The quoted rate is deemed to beinclusive of primer, APP membrane & SBR Latex.
Supply only integral liquid water proofing compound of approved make (ISI marked) for addition in cement mortar/concrete
Material & Labour for providing two coats of oil-bound distemper over a coat of alkali-resistand primer on old plastered surfaces including necessary preparation of surfaces complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F 1.25 mm thick lath steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type
Removing building material/debris to a distance beyond 1.5 Km and spreading in layers
Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) orinsulation boards/slabs/blankets, any thickness, including cover fillets
S&F Anodised aluminium snap grid frame work for false ceiling all as specified size of grid 605x605mm.
Supply & fixing 10 mm thick PVC insulation panels in ceiling board with EPS of net to 1mm printed PVC sheet suitably placed in false ceiling grid all as per specification and drawing
Material & Labour vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm light shade, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Taking up or down steel tubing and connection, including cleaning for re-fixing or removal to store 15 mm dia bore all as specified and directed by Engr-in-Charge
Supplying and laying of 15 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engr-in-Charge
S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm
S&F 75 mm bore PVC (SWR) bends any radius
S&F 75 mm PVC (SWR) junction double, (double T), equal or unequal
Demolition of cement concrete (reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level).
Material & Labour for RCC type B-1, 1:2:4 (using 20 mm graded aggregate) set in cement mortar 1:4 as in landings, cover slabs (for drains, man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces
Material & Labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. Complete.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock all as specified and as directed
M&L for Cement concrete (1:4:8) type D2 as in foundations, filling and mass concrete all as specified and as directed.
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar
Use & waste of formwork to sides of pilars,posts, struts, piers, columns and stanchions, rough finished surfacdes of concrete all as specified
Use and waster formwork to sides and soffits of roof beams, beam haunchings, girders, bressummers, including supports, overhangs, etc. also splays between floors and beams, etc.
Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for TMT bars 8 to 10mm dia in strrups cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
M&L for RCC M-25 (Design Mix) using (20mm graded stone aggregate) as in foundations footing, plinth beams, bases for columns and basement slab, under reamed piles and mass concrete complete all as specified.
M&L for RCC M-25 (Design Mix) using (20mm graded stone aggregate) as in columns, pillars, posts & struts complete all as specified.
M&L for RCC M-25 (Design Mix) using (20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L for RCC M-25(Design Mix) using (20mm graded stone aggregate) as in slab supported on walls, beams and columns (Horizontal or sloping) complete all as specified.
Returning, filling in , including, spreading, levelling, watering and well ramming in layers not exc 25cm thick soil complete all as specified and directed
Removing excavated materials (soft/dis integrated rockl) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
S&F for mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, ladders, railings and similar work complete conforming to Fe-290 Gde E-165 complete all as specified
S&F Roof trusses Fe 410-W(Gde-E- 250) quality-A (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel, or flat sec) incl distance pieces cleats et
M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering as directed by Engr in Charge.
M & L Hard core of gauge n exc 63 mm of broken stone aggregate, deposited,spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface as in plinth protection/ under floor as directed by Engr in Charge.
M & L 100mm thick Cement concrete type B2 ( 1:2:4) using 40 mm graded aggregate as in floor finish the surface even and smooth as specified and directed
Glass dividing stirps 38mm wide and 3mm thick .as directed by Engr in Charge.
S&F aluminium alloy anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick of make M/S Kiran Netting or equivalent as approved by GE.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for appling two coat of Anti corrosive paint over a coat of primer on new steel surfaces of any position not otherwise described over 10 cm width or girth including preparation of surfaces all as directed .
M & L for two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces all as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and makinggood disturbed surfaces of walls, floors, etc.
M&L for point wiring complete with 1100 volts grade PVC insulated and unsheathed multistranded 1.5 Sqmm FRLS single core copper conductor cable drawn through and including PVC conduit concealed in wall with all accessories, & sunken pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, regulator etc including 1.5 Sqmm PVC insulated and unsheathed mutistranded copper conductor cable as earth continuity wire all as specified for one light, fan, socket outlet etc and making good disturbed surface of walls and floors to match with existing surfaces.
All as per serial item No 116 here-in-before but one 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per item No 116 here-in-before but one 6 pin socket outlet 15 Amps independent with cables 4 sqmm size copper PVC insulated cable multistranded and 2.5 sqmm cable conductor for earth wire.
Supply & Fixing switch piano flush button single pole one way 05 Amps .
Supply and fixing switch socket combination 2 in 1, 3/5 pin 5 Amp flush type universal.
Supply and fixing switch socket combination 2 in 1, 3/5 pin 15 Amp flush type universal.
Supply & Fixing stepped type electronic fan regulater flush type 300 watt on existing phenolic laminated sheet etc including removal of old.
Taking down carefully existing ceiling fan of any sweep & make, complete with down rod and opening greasing, oiling including replacement of nut bolt, washer, rubber bush, pin replacement of PVC flexible wire not less thaln 1 mtr from the ceiling rose to fan complete all as directed.
S & F Wall mounted fan of sweep 400mm,RPM 2200,Air delivery 100 CMM complete.
Taking down carefully existing exhaust fan of any sweep & make, with lowers and refixing at new location complete all as directed by Engr-in-Charge
Supply and fixing 25W 4ft long LED batten light fitting with 2.5 KV voltage surge protection ,PF >0.9 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size .Make Bajaj: Product Code 830258(4FT 25W CDL IVORA) or Equivalent in Philips/Havells
S & Fixing Submain wiring with 10 sqmm 2 Runs of single core multi stranded PVC in related unsheathed cable 1100 Volts with copper conductor drawn in and inncluding 25 mm dia in non metallic rigid concealed conduit with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 10 sqmm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to Existing main switch board \ Distribution Board and testing on completion including Taking down old submain wiring and type of conduct complete all as directed.
S & Fixing Submain wiring with 6 sqmm 2 Runs of single core multi stranded PVC in related unsheathed cable 1100 Volts with copper conductor drawn in and inncluding 25 mm dia in non metallic rigid concealed conduit with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 6 sqmm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to Existing main switch board \ Distribution Board and testing on completion including Taking down old submain wiring and type of conduct complete all as directed.
Supply and fixing sheet metal enclosure (DB) TPN ,4 way ,415 V,double door for MCBs with IP 54- IK 09 complete.
Supply and fix sheet metal enclosure (DB) SPN,16 way ,240 V double door for MCB's with IP 54- IK 09 complete.
Supply and fix sheet metal enclosure (DB) SPN,8 way ,240 V double door for MCB's with IP 54- IK 09 complete.
Supply and fix MCB 4 pole, 63 Amp, 415 Volts, 'C' series 10 KA.
Supply and fix MCB, single pole & Neutral, 40-63 Amp, 240 Volts, 'C' Curve 10KA.
Supply and fix MCB, single pole, 6-32 Amp, 240 Volts, 'C' Curve 10KA.
Material and labour for earthing complete with GI steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including necessary earth work and excavation of in any type of strata, chamber in PCC 1:2:4 type B-2 with CI cover, GI tubing 20 mm dia for watering and 15mm dia GI tubing for protection of wire etc all as per electrical plate No.3 of SSR part I including connecting to electrical equipments and testing on completion.
M & L for fine river sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as directed and specified. Note:- Thickness after punning shall be measured for payment
Supply and laying PCC cable cover class LV type 1 flat size 250mm x 150mm x 40mm.
Supply and fixing GI tubing (light grade) with all fittings,laid in trenches, or fixed along with walls /poles,bore of pipe 50mm.
Supply and fixing GI tubing (light grade) with all fittings,laid in trenches, or fixed along with walls /poles,bore of pipe 40mm for cable protection.
S & F LED Bldg Security Street light 30W ,IP 65 with 10KV surge protection including suitable size of GI pipe 1.2 m long bent to required shape,clamps,nut ,bolts and making electrical connection to the fitting with Suitable size of service wire .
Supply ,laying & testing XLPE insulated PVC sheathed heavy duty LT electric cable 1100 volts grade galvanised steel strip armoured with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core, IS-7098 Part-I including centre gland, lugs,jointing materials etc llaid in trenches/road crossing/on pole or wall etc .all as specified and directed.
Supply ,laying & testing XLPE insulated PVC sheathed heavy duty LT electric cable 1100 volts grade galvanised steel strip armoured with stranded aluminium conductor cross sectional area 10 sqmm 2 core,IS-7098 Part-I including centre gland, lugs,jointing materials etc llaid in trenches/road crossing/on pole or wall etc .all as specified and directed.
M & L for Cement concrete M-15 (Nominal mix)(1:2:4) using 20mm graded crushed stone aggregates in PCC block complete all as speciifed.
M & L for one point wiring with 1.5 sqmm PVC insulated un-sheathed cable with stranded copper conductor FR-LSH confirming to IS : 694 of size 1.5 Sq mm single core, including one No 1.5 Sq single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn through and incl concealed stove enamelled steel conduit of 20mm dia size including all accessories etc as required of suitable dia for one light / exhaust fan point controlled by one flame proof switch complete as directed.
Supply and Fixing of flame proof 2X16/20 watt LED tube light fitting with IP65 protection complete with all accessories ,internally pre-wired including conecting up with suitable size twin core FRLS copper conductor as directed . Make: Crompton/Bajaj/Sudhir/Havells
S & F Flame proof exhaust fans AC single phase 230/240 V of size 305 mm sweep,1440 RPM with louvers all as specified.
Supply and Fixing of flame proof rotory switch in LM-6 enclosed in and including aluminium body enclosure with threaded cover with toggal action switch operated by a shrouded knob single pole, 10 Amps with double entries through way suitable for 20mm dia ERW threaded rigid steel conduit and 01 No MS plug of 20 mm dia . Make- SUDHIR Cat part No RI/A/146-3 (or) equivalent Make- BALIGA/FCG Power
Supply & Fixing sheet metal enclosues(DB) for MCB's, 8 way ,single pole & neutral ,240 volt,double door with IP-54 complete.
Supply & Fixing SPN MCB,AC, 'C' curve , 230 V, 16 -25 Amp.
Supply & Fixing SP MCB,AC, 'C' curve , 230 V,2-4 Amp.
Supply and Fixing two run of single core PVC insulated cable with multistranded copper conductor of size 2.5 Sqmm & including one run of 2.5 Sqmm PVC insulated multistranded copper cunductor as a earth wire from earth doly to sub main board including ERW stove enameled steel conduit of suitable dia with all accessaries required and conecting up complete all as directed by Engineer-in-Charge. (Note:- Two run of PVC cables and one run of conduit & Earth wire shall measured as one length.)
Supply and Fixing of flexible metalic hose conduit from junction box to tube light fitting not less than 500mm long of size M20/3/4" conduit M x M / FM x M / F 500mm Make- SUDHIR Cat part No MH/145 or equivalent in BALIGA/FCG Power
Supply and Fixing of 90 degree flameproof bend Make- SUDHIR Cat part No BN/C/165 (or) equivalent in BALIGA/FCG Power
Supply and Fixing of flameproof Union (MXF) Make- SUDHIR Cat part No ACC/2C/2019 (or) equivalent in BALIGA/FCG Power
Air termination single pointed aluminium rod 12mm dia and 300mm long complete fixed with 40mm dia,1.5mtr long GI pipe light grade incl providing flat iron clamps,nuts & bolts,embedding the GI pipe in PCC M-10 block (nominal mix) of size 30x30x40cm and connecting complete . Note:- GI pipe,PCC will be measured and paid separately.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm,drilled and screwed including three Nos 8mm dia 25mm long hex head screw all as specified and directed by Engr-in-Charge.
M & L for Aluminium Strip 25 X 3mm with saddle and fixing screws and clamps for supporting on GI pipe etc for roof conductors and down conductors above ground all as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mm×600mm× 6mm buried directly in ground earth pit not less than 2.25mtr below normal ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including GI strip 32x6mm earth lead by means of 2 nos bolts, nuts,check nuts and washers of galvanised iron upto test point including 20mm dia medium grade GI pipe of suitable length as watering pipe with funnel and wire mesh including excavation and earth work in any type of soil, PCC pit in PCC (1:2:4) type B1 using 20mm grade stone aggregate angle iron frame work with RCC 1:2:4 cover 40mm thick reinforced with 8mm dia deformed bars @ 150mm C/C both ways and handlecomplete all as shown in electrical plate No 3 of SSR (Part-I) and testing on completion.
M & L for GI strip 32x6 mm buried in ground as earth continuity conductor for loop earthing all as directed.
M&L for point wiring complete with 1100 volts grade PVC insulated and unsheathed multistranded 1.5 Sqmm FRLS single core copper conductor cable drawn through and including PVC casing and casing (surface) ISI marked with all accessories, & sunken pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, regulator etc including 1.5 Sqmm PVC insulated and unsheathed mutistranded copper conductor cable as earth continuity wire all as specified for one light, fan, socket outlet etc and making good disturbed surface of walls and floors to match with existing surfaces.
Taking down carefully existing ceiling fan from any height of any sweep & make with down rod and refixing the same by replacing the existing short length downrod with 750mm long new down rod with suitable shackle clamp complete incl replacement of PVC flexible wire not less than 1.5 mtr length from the ceiling rose to fan complete all as directed by Engr-in-charge.Note: Item rate quoted includes the cost of taking down existing ceiling fan, new downrod 750mm long with shackle clamp & connecting cable /wire refixing.
S & F Ceiling Fan 1200 mm sweep air delivery 220cmm complete
Supply & fixing Recess mounting LED fittings 36 watts including suitable electronic driver (having Surge Protection), system Luminous Efficacy (lm/w)≥ 100, Colour temp(CCT) 4000k, suitable for 600 mm x 600 mm modular/POP/Gypsum ceiling, luminaire with white acrylic flat light dissipator, 230V, high quality indoor batten with aluminium extrusion and all accessories internally prewised and including connecting up with twin copper twisted flexible conductor cable of suitable size. Make Havells cat part No VENUSNEO1-10V2X2PLR34WLED857MOD and driver code LEDDRIVER36V24WS or equivalent in : Philips/Bajaj/C&S/Crompton
S & Fixing Submain wiring with 10 sqmm 4 Runs of single core multi stranded PVC insulated unsheathed cable 1100 Volts with copper conductor drawn in and including suitable size non metallic rigid (PVC) concealed conduit with all accessories such as tees, elbows, junction box Reducers etc as required along with 2 Run of 6 sqmm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to main switch board \ Distribution Board and testing on completion including Taking down old submain wiring any type of conductor complete all as directed.
S & Fixing Submain wiring with 4 sqmm 2 Runs of single core multi stranded PVC insulated unsheathed cable 1100 Volts with copper conductor drawn in and including 25 mm wide in non metallic rigid conduit with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 2.5 sqmm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to Existing main switch board \ Distribution Board and testing on completion including Taking down old submain wiring any type of conductor complete all as directed.
Supply and fixing sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 16 Amps, 240 Volts complete.
Supply and fixing flush type sheet metal enclosure DB, VTPN, 6 way, 415 volts, IP 54 ,double door with 250 amp rated copper bus bar for each phase,2 No neutral bar ,2 No earth bar including provision for 160 Amps MCCB as incomer and SP/TP MCB's as outgoing complete all as directed by Engr-in-Charge.
Supply and fixing MCB 4 pole, 40 Amp, 415 Volts, 'C' series 10 KA.
Supply and fixing MCB tripple pole and neutral, 63 Amp, 415 Volts, 'C' series 10 KA.
Supply and fixing MCB tripple pole and neutral, 40 Amp, 415 Volts, 'C' series 10 KA.
Supply and fixing MCB, Triple pole , 40 Amp, 415 Volts, 'C' series 10 KA.
Taking out LT XLPE cable of any size from trenches and re-laying/refixing the same at different location complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling rose, surface bakelite 65 x 50mm two to three terminals
Taking up/removing of old Existing LT Panel from Varndah of P24 Bldg by cutting 04 Nos Legs of LT Panel made out of Equal angle 35x35mm of 5mm thickness complete all as directed by Engineer-in-charge.
CVs CONSTRUCTIONS
M/S jvsr constructions
Tara Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .