Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | ₹1.3 Cr | L1 | Accepted-AOC QUOTED AMOUNT LOWEST |
| 2 | L2₹1.4 Cr+₹12.7 L (10.2%)Rejected-Finance | ₹1.4 Cr+₹12.7 L (10.2%) | L2 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 3 | L3₹1.4 Cr+₹17.6 L (14.1%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹1.4 Cr+₹17.6 L (14.1%) | L3 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 4 | L4₹1.5 Cr+₹20.8 L (16.6%)Rejected-Finance A 212B GALI NO 1 SHAKARPUR | DELHI | EAST DELHI | DELHI | 110092 | ₹1.5 Cr+₹20.8 L (16.6%) | L4 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 5 | L5₹1.5 Cr+₹27.1 L (21.6%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹1.5 Cr+₹27.1 L (21.6%) | L5 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
31 Jan 2022, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT-10
ADDN ALTN AND UPGRADATION OF 06 X BLDGS P-01 TO P-06 AT RRRC UNDER GE CENTRAL DELHI CANTT-10
2021_MES_490474_2
CWE/D-38/2021-22
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt
As per Tender NIT
7 documents required · 7 mandatory
₹1,000
GE CENTRAL DELHI CANTT
₹2.2 L
Yes
22 Feb 2022
11 Jan 2022
1 Feb 2022
11 Jan 2022
31 Jan 2022
18 Jan 2022
Amount
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc., all as directed.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc complete all as specified and directed
M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement with using water proofing compound up to height of two storey bldg ,including scaffolding complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concrete surfaces of walls finished even and smooth without using extra cement up to height of two storey bldg, including scaffolding complete all as specified and directed.
M & L for 10 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement incl scafolding etc up to 10 m, complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat putty up to 10 m height including scaffolding complete all as specifed as direted by Engr-in-charge.
M&L for preparation of newly plastered surfaces and applying two coats of Oil bound distemper over one coat of wall putty on newly plastered surface over a coat of primer upto 6m height including scaffolding.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash upto 6m height including scaffolding complete.
M&L for complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat of white washing upto 6m height including scaffolding complete all as specified and directed.
M&L for complete removal exising teratment from old surface of ceiling by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat of white washing upto 6m height including scaffolding complete all as specified and directed.
complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat of oil bond distemper over one coat of putty upto 6m height including scaffolding complete all as specified and directed.
M&L for complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat of cement based paint up to hieght of two storey ,including scaffolding complete all as specified and directed.
Dismantling of wall and ceiling board fibre pulp AC boards etc any thickness including cover fillets including fixture as necessary at site including frame work
S&F 6mm thick plywood grade BWR type BB of (5 Nos of ply) fixed with screws to timber frame work
M&L second class hard wood timber scantling plain fillets, square, rectangular or triangular in section clear swan, sectional area exc 13 sqcm & not exc 25 sqcm, secured with nails or brads complete all as specified.
M&L second class hard wood beading plain fillets, square, rectangular or triangular in section clear swan, sectional area exc 3 sqcm & n. exc 6 sqcm, secured with nails or brads complete all as specified.
Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame)
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame)
Taking down shutters of any discription exceeding 1 sqm each and not exceeding 2 sqm each
Taking down shutters of any discription n.exc 1 sqm each complete all as specified.
Refixing shutters in same opening of any discription exceeding 1 sqm each and not exceeding 2 sqm each
M&L II nd class hard wood Plain solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with iglue pinned at joints, supplied and fixed all as specified and directed.
M&L Mild steel frame work as in door chowkhats with angle iron welded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size, and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges paid sep) all as spd including cutting of brick wall and PCC 1:2:4 type 'B0' for fixing chowkat.
M&L for 35 mm thick 2nd class hard wood skelton shutter, open rebated and prepared to receive glass/guage etc. edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing etc size of member as specified in SSR Part I Section 8 clause 8.24(a) and fixed to chowkat, complete all as specified.
M & L for 35 mm thick factory made 2nd class hardwood plain, framed, panelled shutters (two panels), with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per IS:1003 (Part-I) kiln seasoned and chemically pressure treated
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.including making good all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer
M & L for preparing of old wooden surface and applying one coats of synthetic enamel paint complete all as specified.
M&L for one coat of synthetic enamel paint on old steel surfaces of any description, not otherwise described over 10cm width or girth after preparation complete.
S & F 100 mm butt hinges, heavy weight, cold rolled mild steel, and fixed, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt extruded section 200 mm long and fixed with MS screws.
S&F 200 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws.
S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut.
S&F 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar all as directed.
S&F two legged aluminium floor door stopper with rubber shoe 140mm long complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed.
Material and labour for welding in repairs not exc 2.5 cm in length complete all as directed
S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified
S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed.
M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed.
M&L for Non - skid Ceramiccolour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed.
M&L for machine cut polished Machine cut kota stone 12-15mm thick as in risers of steps,skirting, dado and pillar fixed with neat cement slurry over backing coat of 10mm thick in CM (1:3) including rubbing and polishing complete all as specified.
M&L for machine cut polished Machine cut kota stone 18-20mm thick as in floor fixed with neat cement slurry over 15mm thick scrred bed in CM (1:4) including rubbing and polishing complete all as specified.
M&L for 18 -20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
M&L for 18-20mm thick Granite (of any type) work (vertical portion) for wall lining 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
S&F Chequered cement concrete tiles with grey cement and pigment 30cm X30cm X22mm thick set jointed and pointed in neat cement slurry in floors and including 75mm thick cement concrete type D-2 1:4:8 and incl 15mm thick screed bed in CM 1:6 all as specified and directed.
Dismantling of corrugated steel sheet (corrugated or semi corrugated ) fixed in roof including ridge complete all as specified and directed.
S&F for .63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc complete all as specified and directed.
All as per item No above here-in-before but fixed in ridges complete all as specified and directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
M&L for roof treatment as per the description below including dismantling/taking down existing roof treatment complete:- a) preparation of roof surfaces by removing all loose material /dust extra for carrying out water proofing treatment. b) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm of prepared surfaces. c) Laying APP (Atatic Polypropylene) modified five layered membrane 3 mm thick and weighing not less than 4 Kg/Sqm with centre core 160 GSM/ Sqm ; core reinforced and laid with 75 mm side overlap and 150 mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm and apply two coat of silver shield bitumestic aluminum paint all as specified
M & L for PCC 40 mm thk type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in roof complete all as specified and directed.
M&L providing PCC 1:2:4 Type B-0 12.5 mm graded agg. In precast copings incl slightly rounded chemered angles and throating including necessary form work complete.
Demolition of concrete and pavings n.exc 15 cm thickness (below or above ground level)
M&L for cement concrete 40mm thick type B-0, 1:2:4 (using 12.5 mm graded aggregate) as in floor and making even and smooth using extra cement complete all as specified and directed
S&F 38 mm wide and 3mm thick glass dividing strips inserted in position, conform to design complete all as specified and as directed.
M&L for cement concrete 75mm thick type C-2 1:3:6 (40mm graded aggregate)as in plinth protection and paths laid in alternative panel.
Demolition of reinforced cement concrete in any position all as specified and as directed by Engineer -in-Charge.
M&L 50mm thick sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 up to height 10 m complete all as specified and directed.
S & F in repair Aluminium drapery Rod 25mm dia Powder Coated including wooden side caps, brackets complete all as specified and directed.
S&F 2.5mm dia plain mild steel wire, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for conceled water tubing etc cutting exceeding 10cm girth but not exc. 20 cm all as directed.
S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified
S&Fin repairs stop valve, concealed, fancy type , chromium plated brass, screwed down, high pressure screwed both ends for iron pipe or for unions, 15mm bore with long shank and cup complete all as directed.
S&Fin repairs shower rose, chromium plated brass, fancy type, 100x100 mm, with or without swivel , any size, including fixing to steel pipe or union, complete all as directed.
Material and labour for rotational moulded polyethylene water storage tanks white colour 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description.
Taking down carefully copper/aluminium point wiring from wooden battan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:-
(a) One light /fan point/Socket on Independent board controlled by one, one way switch .
(b) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
(c) One light point controlled by two Nos two way switches
All as per item No.2 herein before but with 4 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 77 & 78 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing/caping to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
M & L Submain wiring with two run single core 1.5 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in and including new PVC conduit ISI marked conealed alongwith one run of 1.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 1.5 sqmm cable and one run of PVC conduit shall be measured as one RM.
M & L Submain wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in and including new PVC conduit ISI marked concealed alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in and including new PVC conduit ISI marked concealed alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
M&L switch Piano flush type 5 Amp SP one wayall as specified and directed by Engr in Charge.
M&L switch piano flush type 15 Amp SP one way all as specified and directed by Engr in Charge.
M&L socket outlet 5 pin 5 Amp flush type all as specified and directed by Engr in Charge.
M&L socket outlet 2 in 1,3 pin 5/15 Amps all as specified and directed by Engr in Charge. Make:-
M&L ceiling rose 3 phase PVC polycorbonate,isolated body.
S & F electronic fan regulator 5 step 360 degree rotation connecting complete all as specified
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp, 240 Volts all as specified and directed.
Disconnecting elect connection and taking down of ceiling fan / Exaust fan/fresh air fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge.
M&L angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete.
Supply and fix LED batten luminaire surface mounted 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 12 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥80 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
M&L switch Piano flush type 5 Amp SP two way all as specified and directed by Engr in Charge.
Supply and Fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
S & F wall mounting air circulator fans AC single phase 230/240V, 1440 RPM of size 600 mm sweep(24"), 180 Watt , aluminium alloy three blade , double ball bearing 90 oscillation , sturdy close-mesh guard beautiful designed, powerful heavy duty motor, air delivery 270 m/Min, mounting on wall complete all as specified and directed by Engr-in-charge. Make:- almorard or equivalent as per approved make list.
Supply and fixing ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, ISI mark, rated Air delivery >220 cum/min, service value > 6 AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length including 2 mtr long down rod duly amde off mild steel, complete all as directed
S&F surface /ceiling mounted, round LED down light fitting 10/12 watts with die cast aluminium housing and system wattage of 12W, including connecting up with PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S & F Sturdy LED bollard with excellent lightoutput through its PMMA window ensuring maximam illumination aspect in surrounding with 10 Watt IP-65 having pole height 0.6 Mtr incl cement work etc all as specified and directed by Engr-in-charge.
S & F 10/ 12 watts LED bulkhead fitting, PVC body including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply & fix fresh Air fan 250mm sweep with louvers including connecting with suitable size of copper conductor from ceiling rose to fan and making hole of suitable size and matching with the existing coloure of wall complete all as specified and directed.
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base all as specified and directed.
S & F water heater storage type Geyser vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection having adjustable knob for temperature control and inner tank should be glass line coated tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity , should be glass line coated capacity 50 ltrs having heating element 1.5 KW and not less than 5 star ratingh suitable for 230 Volt , 50 Hz electric supply complete all as specified and directed.
M&L for earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed.
M & L DB SPN 8 way with 100 Amp rate bus bar double door
M&L MCB SPN 40 Amp "C " curve .
S&F MCB SP 6-32 Amps 240 volts curve 'C' series 10 KA 50 HZ complete all as specified and directed.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. complete all as specified and directed by Engineer in charge.
S&F XLPE duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 3.5 core duly fixed on PVC saddle and spacer complete all as specified and directed
M&L MCCB 125 Amps, 4P, 415 volts 16 KA 50 HZ with thermal magnetic setting all as specified and directed by Engr -in Charge.
M/S SHRINARAYAN MEENA
The new hut furnitures
VED PRAKASH ARORA
imran construction company
Simran construction Company
Bidder Name
The new hut furnitures
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .