EXECUTIVE ENGINEER
EE, ELECTY. 400KV S/S DIVISION, SULTANPUR
Routine maintenance of Transformers/Reactors/ Isolators/Bus Bars/Jumpers etc and replacement of damaged Jumpers, Servicing of DPPs/CR Panels etc. along with other associated at 400KV S/s Division, Sultanpur
2021_UPTCL_608474_1
T.No. 04/ESDS/2021-22
Open Tender
Electrical Works
Item Wise
180 days
Sultanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹236
SE ETC Sultanpur
₹2,000
Yes
25 Aug 2021
3 Aug 2021
25 Aug 2021
3 Aug 2021
23 Aug 2021
3 Aug 2021
3 Aug 2021 - 23 Aug 2021
Amount
Maintenance/Tightening of following 3 Phase Isolators including adjustment of Arms, Earth Switch, Tightening of Bolts- Nuts, Clamps/Connectors, Jumpers etc. including Oiling and Greasing of Operating Mechanism for proper operation including replacement of damaged parts (Parts to be provided by the department).
Maintenance/Tightening of 400KV Pantograph Isolator without Earth Switch .
Maintenance/Tightening of 400KV Pantograph Isolator with one Earth Switch.
Maintenance/Tightening of 400KV Standard Isolator with two Earth Switch .
Maintenance/Tightening of 220KV Tandem Isolator.
Maintenance/Tightening of 220KV Standard Isolator with one Earth Switch.
Maintenance/Tightening of 220KV Standard Isolator with two Earth Switch.
Servicing of Control & Relay Panels/DPPs by due Cleaning of Panels from inside by Air Blower & Soft Brush to remove deposit of dust & other foreign materials.
Tightening/maintenance of following Transformers/ Reactors as per maintenance schedule and technical specification including cleaning, tightening of bolts & nuts, control cable connections etc :-
Maintenance/Tightening of 315MVA 400/220KV Transformer-I, & III, 240MVA 400/220KV ICT II as per availability of shutdown.
Maintenance/Tightening of 80MVAR Bus Reactor.
Maintenance/Tightening of 50MVAR Line Reactor installed in 400KV Sultanpur-Obra line I & II.
Maintenance/Tightening of 400KV Bus-Bar of Quad ACSR Moose Conductor bu tightening of all Bolts- Nuts, Clamps/Connectors, Jumpers etc. including minor repair work alongwith cleaning of associated Disc Insulator Strings.
Maintenance/Tightening of 220KV Bus-Bar of Twin ACSR Moose Conductor by tightening of all Bolts- Nuts, Clamps/Connectors, Jumpers etc. including minor reoair work alongwith cleaning of associated Disc Insulator Strings.
Maintenance/Tightening of Transfer Bus Twin ACSR Moose Conductor by tighening of all Bolts- Nuts, Clamps/Connectors, Jumpers etc. including minor repair work alongwith cleaning of associated Disc Insulator Strings.
Tightening of Jumpers/Clamps/Connectors/Bolts-Nuts etc. in various 400KV Bays.
Tightening of Jumpers/Clamps/Connectors/Bolts-Nuts etc. in various 220KV Bays.
ELECTRO INDIA
DEEPAK ENGINEERING
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .