Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC SHOP NO 11 18 CITY CENTRE 930 931 SYNAGOGUE STREET PUNE 01 | L1 | Accepted-AOC lowest | |
| 2 | L2₹33.4 L+₹1.1 L (3.29%)Rejected-Finance | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹33.6 L+₹1.3 L (3.98%)Rejected-Finance 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹35.3 L+₹3.0 L (9.22%)Rejected-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L4 | Rejected-Finance RATE HIGH |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE South Pune
NO 1 GEN BHAGAT MARG PUNE 411040
8581 MAINT REPLACEMENT REPAIR OF INTERNAL SWITCHGEAR SUBMAIN WIRING UPS OT LIGHT CALLING SYSTEM ELECTRICAL PROTECTIVE SYSTEM FITTING WIRINGS GEYSER AND CERTAIN MISC WORK IN HOSPITAL AREA OF AICTS UNDER AGE EM I OF GE SOUTH PUNE
2024_MES_664671_1
8581 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE South Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹80,000
Yes
28 Oct 2024
8 Jul 2024
16 Sept 2024
8 Jul 2024
13 Sept 2024
3 Aug 2024
Amount
Taking down carefully exising unserviceable aluminium point wiring including all fittings like light point, fan point, socket, switches, ceiling rose, pendent, regulators etc removing material to store and making good the disturbed surfaces of walls, floors, ceilings etc to match with the existing complete all as specified and as directed.
M&L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel flush box , concealed in wall and making good disturbed surfaces of walls & matching the as per existing surface) with laminated modular cover plate with frame for fix modular switch, socket regulator etc, concealed in wall including with FRLS 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following:- (a) One light point/fan point /Exhaust fan point controlled by one switch
(b) One socket outlet 5 Amps controlled by one switch on the same board.
(c) One socket outlet 5 Amps controlled by one switch on independent board.
(d) One bell / buzzer controlled by one bell push
All as per item No.2 above but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sq mm PVC insulated multi-stranded copper conductor cable as continuous earth wire complete all as specified and directed
M & L for Point wiring using approved colour coding as per IS, with multi-stranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI flush box / PVC surface boxes with earth dolly duly as per site requirement, covered with modular white cover plate with frame suitable for modular switches of including PVC insulated multi-stranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following:- (a) One light point/fan point /Exhaust Fan point controlled by one switch
(b) One socket outlet 5 Amps controlled by one switch on the same board.
(c) One bell point controlled by one bell push
(e) Socket outlet point 5 Amps controlled by one switch on independent board.
All as per item No.4 above but with 2.5 Sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sq mm PVC insulated multi stranded copper conductor cable as continuous earth wire complete all as specified and directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 4 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 1x4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty concealed PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-One meter length of conduit and 3 runs of 4 sq mm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 1x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty concealed PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-One meter length of conduit and 3 runs of 6 sq mm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 4 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 1x4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including PVC casing caping heavy duty of suitable size of white / ivory colour and its accessories ISI marked fixed to wall / ceiling etc and connected to common earth dolly including includidng making good the disturbed surfaces walls / ceilings by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-One meter length of PVC casing caping and 3 runs of 4 sq mm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 1x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including PVC casing caping heavy duty of suitable size of white / ivory colour and its accessories ISI marked fixed to wall / ceiling etc and connected to common earth dolly including includidng making good the disturbed surfaces walls / ceilings by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-One meter length of PVC casing caping and 3 runs of 6 sq mm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 2x4 Sqmm nominal cross sectional area, two core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty concealed PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-One meter length of conduit, 4 runs of 6 sq mm and 2 runs of 4 Sqmm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS with stranded copper conductor of size with 10 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 2x6 Sqmm nominal cross sectional area, two core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty concealed PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-One meter length of conduit, 4 runs of 10 sq mm and 2 runs of 6 Sqmm stranded copper conductor cable shall be measured as one unit length.
S & F for Modular Switch one way, 6 Amp, 240 volts 1 module, complete all as specified and directed.
S & F for Modular Switch one way, 16 Amp, 240 volts 1 module, complete all as specified and directed.
S&F in repairs modular Socket outlet multipurpose having provision for 3 pin 6 Amp and 2 pin 6 Amp, 2 module piano flush type, complete all as specified and directed.
S&F in repairs Modular Switch Socket outlet multipurpose having provision for 3 pin 16 Amps and 2 pin 6 Amp, 2 module, complete all as specified and directed.
S & F modular step type fan regulator 120 watt 2 module complete all as specified and as directed.
S & F modular bell push 6 Amps, 1 module, complete all as specified and directed.
S & F in repairs Ding Dong electric bell AC, 240 Volts single pole, complete all as specified and directed
S & F in repairs switch bell push button type 5 Amp single pole complete all as specified and as directed.
S & F in repairs switch socket combination outlet flush type multipurpose with or without gang box 2 in 1, 3 pin 6/16 Amp, 230 Volts, complete all as specified and directed
S & F in repairs switch socket combination outlet flush type multipurpose with or without gang box 2 in 1, 6 Amp, 230 Volts, complete all as specified and directed
S&F lamp holder insulated body with back plate for batten fittings with and incluidng 9 watts LED bulb 5 star rated, complete all as specified and directed.
S&F ceiling rose surface bakelite, two to three terminals complete all as specified and as directed.
S & F Switch piano flush type, single pole, one way, and 6 Amp, complete all as specified and directed.
S&F in repairs Switch piano flush type, single pole, one way, and 6 Amp, complete all as specified and directed.
S&F in repairs Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type, complete all as specified and directed.
S&F in replacement of universal socket outlet flush type 5 pin, 6/16 Amps fixed and connect in existing board, complete all as specified and directed.
Supply & fix in repairs PVC connections pipe with brass hexagonal adapters both side, suitable for 15mm dia pipe having length 45 / 60cm suitable for cold / Hot water as per site requirement complete all as specified and as directed
S&F electronic step type fan regulator / Mini switch type dimmer 120 / 280 Watt capacity including connecting up complete all as specified and as directed
S&F in replacement recess mounting LED down light fitting 6/8 Watts, natural white / worm white complete as per existing size and type including repairs / making good the POP / Gypsum ceiling with good finish to match as existing with suitable fixing arrangement connection including taking down of old unserviceable ceiling fitting any type, complete all as specified and directed.
S&F in replacement recess mounting LED down light fitting 10/12 Watts, natural white / worm white complete as per existing size and type including repairs / making good the POP / Gypsum ceiling with good finish to match as existing with suitable fixing arrangement connection including taking down of old unserviceable ceiling fitting any type, complete all as specified and directed.
S&F in replacement recess mounting LED down light fitting 18/20 Watts, natural white / worm white complete as per existing size and type including repairs / making good the POP / Gypsum ceiling with good finish to match as existing with suitable fixing arrangement connection including taking down of old unserviceable ceiling fitting any type, complete all as specified and directed.
S&F in replacement recess mounting LED down light fitting 24 Watts, natural white / worm white complete as per existing size and type including repairs / making good the POP / Gypsum ceiling with good finish to match as existing with suitable fixing arrangement connection including taking down of old unserviceable ceiling fitting any type, complete all as specified and directed.
S&F in repair LED flood lights fitting 20 watts natural / worm white /RGB / GR highly efficient with integral type mid power made of pressure die cast aluminium housing with toughened glass and IP-66 protection, including taking down of old unserviceable light fitting any type, complete all as specified and directed.
S&F in repair LED flood lights fitting 50 watts natural / worm white /RGB / GR highly efficient with integral type mid power made of pressure die cast aluminium housing with toughened glass and IP-66 protection, including taking down of old unserviceable light fitting any type, complete all as specified and directed.
M & L for LED panel Recess mounted -2'x2' - 34/ 36 watts light fitting natural white / worm white complete with heat exchanger unit complete including cutting hole of required size in POP / false ceiling and making good disturbed surfaces as per existing including taking down of old unserviceable ceiling fitting any type, complete all as specified and directed.
M & L for LED panel Recess mounted -1'x1' - 18 watts light fitting natural white/ worm white complete with heat exchanger unit complete including cutting hole of required size in POP/false ceiling making good disturbed surfaces as per existing including taking down of old unserviceable ceiling fitting any type, complete all as specified and directed.
M & L for LED panel Recess mounted -4'x1" - 45 watts light fitting natural white/ worm white complete with heat exchanger unit complete including cutting hole of required size in POP/false ceiling making good disturbed surfaces as per existing including taking down of old unserviceable ceiling fitting any type, complete all as specified and directed.
S&F in repairs LED strip light 6 Watts, 12 Volts, natural white / worm light with driver complete all as directed
S&F in replacement driver suitable for LED panel Recess mounted -2'x2' - 36 watts lights of existing make, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement driver suitable for LED panel recess mounted light 10 to 24 watts of existing make, complete all as specified and as directed by Engr-in-Charge.
S & F in repairs surface mounted rounded panel light, 18 Watts, natural white / worm light including with driver complete all as specified and directed.
S&F in repairs of wall mounting fancy light fitting with polycarbonate cover complete with all accessories (connector block, lamp holders etc.) with and including 9 Watts LED lamp including taking down of old unserviceable fittings of any type complete all as specified and directed
Supply and fix in repairs LED tube light fitting natural white / worm white complete with all fitting and accessories, 1X20 watts pre-wired with high efficiency electronic driver, PVC body glare free, smooth light distribution complete including taking down of old unserviceable fittings of any type complete all as specified and directed. Make- Havells / Wipro/Philips /Crompton
S&F in repairs LED tube light fitting 20 watts with aluminium extrusion housing, natural white / worm white complete with all fitting and accessories, pre-wired with high efficiency electronic driver, PVC body glare free, smooth light distribution complete including taking down of old unserviceable fittings of any type complete all as specified and directed. Make- Havells / Wipro/Philips /Crompton
S&F in repairs wall light fittings including with all accessories 3 Watts including taking down of old unserviceable fittings of any type complete all as specified and directed. Make- Havells / Wipro/Philips /Crompton
S&F in repairs LED tube rod 10 Watts single / double side wire connection including taking down of old unserviceable tube rod complete all as specified and directed
S&F in repairs LED tube rod 18 Watts single / double side wire connection including taking down of old unserviceable tube rod complete all as specified and directed
S&F in repairs LED lamp, 9 Watts, PL LED pin type, including taking down of lod unserviceable lamps complete all as specfied and directed.
Supply only for replacement of unserviceable Multi-core round PVC cables of size 1.5 Sqmm, single core, FRLSH, insulated multi-stranded copper conductor for working voltage 1100 volts Sqmm complete all as specified and directed
Supply only for replacement of unserviceable Multi-core round PVC cables of size 2.5 Sqmm, single core, FRLSH, insulated multi-stranded copper conductor for working voltage 1100 volts Sqmm complete all as specified and directed
Supply only for replacement of unserviceable Multi-core round PVC cables of size 4 Sqmm, single core, FRLSH, insulated multi-stranded copper conductor for working voltage 1100 volts Sqmm complete all as specified and directed
Supply only for replacement of unserviceable Multi-core round PVC cables of size 6 Sqmm, single core, FRLSH, insulated multi-stranded copper conductor for working voltage 1100 volts Sqmm complete all as specified and directed
S& F in replacement of PVC modular gang box 3M size plain vertical/ horizontal including PVC modular frame fixing modular / flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S& F in replacement of PVC modular gang box 6M size plain vertical/ horizontal including PVC modular frame fixing modular / flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S& F in replacement of PVC modular gang box 8M size plain vertical/ horizontal including PVC modular frame fixing modular / flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S& F in replacement of PVC modular gang box 12M size plain vertical/ horizontal including PVC modular frame fixing modular / flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S& F in replacement of PVC modular gang box 16M size plain vertical/ horizontal including PVC modular frame fixing modular / flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S& F in replacement of PVC modular gang box 18M size plain vertical/ horizontal including PVC modular frame fixing modular / flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S&F in replacement of PVC gang box of 6"x8" size plain vertical / horizontal for fixing flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S&F in replacement of PVC gang box of 6"x12" size plain vertical / horizontal for fixing flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S&F in replacement of PVC gang box of 8"x12" size plain vertical / horizontal for fixing flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S&F in replacement of PVC gang box of 4"x6" size plain vertical / horizontal for fixing flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S&F in replacement of PVC gang box of 4"x4" size plain vertical / horizontal for fixing flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S&F in replacement of PVC gang box of 4"x9" size plain vertical / horizontal for fixing flush switch socket regulator complete all as specified and directed. Make :- Pressfit or equivalent make as approved
S&F in replacement two feet long down rod suitable for 1200/1400 sweep ceiling fans, made out of GI pipe medium grade, 15mm dia with fan clamps including drilling cutting threding etc complete all as directed.
S&F in replacement three feet long down rod suitable for 1200/1400 sweep ceiling fans, made out of GI pipe medium grade, 15mm dia with fan clamps including drilling cutting threding etc complete all as directed.
S&F in replacement four feet long down rod suitable for 1200/1400 sweep ceiling fans, made out of GI pipe medium grade, 15mm dia with fan clamps including drilling cutting threding etc complete all as directed.
S& F in replacement of heavy duty PVC casing caping strip of 2.0 m length each of 25x16mm size including with accessories elbow, tee, feeting screw etc. complete all as specified and directed
S& F in replacement of heavy duty PVC casing caping strip of 2.0 m length each of 32x16mm size including with accessories elbow, tee, feeting screw etc. complete all as specified and directed
Repair / maintenance of internal light fitting by deploying skilled labour i.e 01 skilled Electrician and o1 Helper to attend the complaints of “No light/ceiling fan/ exhaust fan/ geysers/ security light/ ceiling and wall light /Cable fault of any size & type / earth leakage/ short circuit / neutral break mains / substations / internal circuits of existing system of main building / block” and making continuous electric supply including carrying out minor repairs etc as required at site to make the system functional including replacing fuse wire, copper thimbles, glands, etc complete all as specified and all as directed by Engr-in-charge. Note: (i). Attending of one number complaint and make it functional, shall be measured as one job. (ii) Spare parts like switch, socket, regulator, driver, lamp holder, connection wire, capacitor etc. replaced against above mentioned item will be measured & paid for separately under respective items of BOQ as “Supply only”. (iii) The contractor's representative i.e 01 skilled Electrician and o1 Helper will report to concerned JE E/M at 0900 hrs to 1700 hrs daily to collect the list of complaints and will submit the completion report on following day before 0900hrs to concern JE E/M.
(iv) The contractor is responsible to rectify the electric defects/ faults and make the services functional within 24 hours from the time the list of electric defects/ faults is handed over to him / his rep by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the stipulated time limit, an amount of Rs 100/- per such electric defects/ faults per day will be recovered from the contractor’s dues i.e through RAR / Final Bill. (v) The contractor shall maintain proper record of repair / maintenance in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maintenance record register to Engineer-in-charge for inspection every Monday or as and when asked for.
Taking down geysers 25 /35 / 50 litres capacity, carrying to workshop for repairing, servicing, cleaning etc, replacement of unserviceable thermostat or heating element or indicator lamp and thermal cut out (As required) including fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixed the geysers on its original location after making functional, complete all as directed. Note:- Heating element, thermostate inner tank, valve etc shall be measured and paid separately as supply only under respective items of BOQ.
Supply only heating element 2 KW, 230 volt round/ triangular in shape ISI marked, complete all as directed.
Supply only 15mm size pressure release valve, ISI marked, suitable for 25 litres capacity geysers, complete all as directed.
Supply only 25 litres capacity inner tank including necessary welding breazing and filling up the existing glass wool in between geyser tank and outer cover, complete all as directed
Supply only 50 litres capacity inner tank including necessary welding breazing and filling up the existing glass wool in between geyser tank and outer cover, complete all as directed
Supply only heating element 1.5 KW, 230 volt round/ triangular in shape ISI marked, complete all as directed.
Supply only thermostat ISI marked complete suitable for any capacity of geyser, complete all as directed.
S&F in replacement of 10 Sqmm size, one twin core cable flat or circular, 1100 Volts grade, heavy duty service line cable PVC insulated, stranded aluminium conductor, twin core cable, served with inner sheathing of PVC tape and overall PVC sheathed as in service connections including taking down of old unserviceable cable of any type complete all as specified and directed
S&F in replacement of 6 Sqmm size, one twin core cable flat or circular, 1100 Volts grade, heavy duty service line cable PVC insulated, stranded aluminium conductor, twin core cable, served with inner sheathing of PVC tape and overall PVC sheathed as in service connections including taking down of old unserviceable cable of any type complete all as specified and directed
S&F in replacement of 4 Sqmm size, one twin core cable flat or circular, 1100 Volts grade, heavy duty service line cable PVC insulated, stranded aluminium conductor, twin core cable, served with inner sheathing of PVC tape and overall PVC sheathed as in service connections including taking down of old unserviceable cable of any type complete all as specified and directed
Supply and fixing in replacement PVC fresh air exhaust fan 300mm sweep with lovers Make: Bajaj /cromptan /Havells, complete all as directed.
Supply and fixing in replacement PVC fresh air exhaust fan 250mm sweep with lovers Make: Bajaj /cromptan /Havells, complete all as directed.
Supply and fixing in replacement PVC fresh air exhaust fan 200mm sweep with lovers Make: Bajaj /cromptan /Havells, complete all as directed.
Supply and fixing in replacement PVC fresh air exhaust fan 150mm sweep with lovers Make: Bajaj /cromptan /Havells, complete all as directed.
Supply & fix in replacement 16 Amps plug top, 3 pin, 220 volts complete all as specified and as directed
Supply & fix in replacement 6 Amps plug top, 3 pin, 220 volts complete all as specified and as directed
Supply only self adhesive PVC electrical insulation tape, each roll of 7.0 m length of superior quality complete all as specified and directed
Taking down carefully ceiling fan of 1200mm/1400mm sweep, exhaust fan 300mm to 450mm sweep and wall mounded bracket fan 300/450mm sweep from their position complete for servicing such as removing dust and dirt from fan motor, washing blades with detergent powder including greasing to bearings, checking & replacing worn out screws with spring washers, rubber befit washers of fan blades, fan motor body, spilt pin / screw of fan, down rod / check nuts as required for different makes of ceiling / exhaust fans and make fans smooth and satisfactory working and re-fixing ceiling fan / exhaust fan after doing necessary servicing to their position connecting to electric system including with suitable size of cable and testing, complete all as specified & directed. Note:- Spare parts like, bearing, capacitor split pin, gun metal bush, shaft, canopy etc. shall be measured and paid separately as “Supply only” under respective items of BOQ.
Supply only ball bearing 6202/6203 in replacement suitable for AC ceiling fan of 1200/1400 mm sweep / exhaust fan / air circulation fan of any make, complete all as specified & directed
Supply only capacitor 4/5 mfd, 230 volts, AC, 50 Hz, complete all as specified & directed.
Supply only capacitor 2.5 mfd, 230 volts, AC, 50 Hz, complete all as specified & directed.
Supply only Zebra fastener of size 12x100 mm complete all as specified and as directed
Supply only split pin including with hook, rubber, nut & bolt suitable for ceiling fan / exhaust fan of any sweep and make complete all as directed
Supply only shaft of approved quality suitable for ceiling / exhaust fan of any sweep and make complete all as directed
Supply only self lubricating bush of gun metal suitable for ceiling / exhaust of any sweep and make complete all as directed
Supply only fan canopy suitable for ceiling of any sweep and make complete all as directed
Supply only fan blade (set of 3 ) suitable for 1200 /1400 mm ceiling fan, complete all as specified and directed.
S&F in repairs 3 way conductor terminal, bakelite complete all as directed by Engr-in-charge.
Material & labour for preparation of old painted surfaces of ceiling fan, exhaust fan & wall mounting fan by scrubbing, cleaning with sand paper / wire brushing etc making good surfaces and applying synthetic enameled paint of first quality by using spray gun machine in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint, complete all as specified & directed.
Material & labour for preparation of old painted surfaces of geysers of any type by scrubbing, cleaning with sand paper / wire brushing etc making good surfaces and applying synthetic enameled paint of first quality by using spray gun machine in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint, complete all as specified & directed.
Material and labour for rewinding of AC ceiling fan, 230 volts, 50 Hz, 1200mm / 1400 mm sweep of any make with appropriate gauge super enameled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed
Material and labour for rewinding of AC exhaust fan, 230 volts, 50 Hz, 350/400 mm sweep of any make with appropriate gauge super enameled copper winding wire including allied insulation material such as air drying insulation varnish, cotton tapes, lathered film paper, spacers, sleeves etc re-assembling at its position after repair, testing and commissioning, complete all as specified & directed
M&L for comprehensive preventive and periodical maintenance & checking of serviceability of on line UPS installed in various switch rooms / Wards / Dept at MH AICTS as per manufacturer's recommendation in safe and efficient manner by using latest technique & expert consultancy by regularly examining and adjusting the mechanical & electrical driving equipment with including S&F of new spare parts in replacement of defective spare parts / items as required for smooth functioning of UPS and as and when required by employing 01 skilled technician having qualification of ITI or diploma in electrical / Electronic Engineering having adequate experience including Sunday and holiday complete all as specified and entire satisfaction of Engineer-in-charge:- (i) 20 KVA UPS -06 Nos. (ii) 30 KVA UPS-01 Nos.
M&L for comprehensive preventive and periodical maintenance & checking of serviceability of on line UPS installed in various switch rooms / Wards / Dept at MH AICTS as per manufacturer's recommendation in safe and efficient manner by using latest technique & expert consultancy by regularly examining and adjusting the mechanical & electrical driving equipment with including S&F of new spare parts in replacement of defective spare parts / items as required for smooth functioning of UPS and as and when required by employing 01 skilled technician having qualification of ITI or diploma in electrical / Electronic Engineering having adequate experience including Sunday and holiday complete all as specified and entire satisfaction of Engineer-in-charge:- (i) 15 KVA UPS - 06 Nos.
M&L for comprehensive preventive and periodical maintenance & checking of serviceability of on line UPS installed in various switch rooms / Wards / Dept at MH AICTS as per manufacturer's recommendation in safe and efficient manner by using latest technique & expert consultancy by regularly examining and adjusting the mechanical & electrical driving equipment with including S&F of new spare parts in replacement of defective spare parts / items as required for smooth functioning of UPS and as and when required by employing 01 skilled technician having qualification of ITI or diploma in electrical / Electronic Engineering having adequate experience including Sunday and holiday complete all as specified and entire satisfaction of Engineer-in-charge:- (i) 125 KVA UPS - 01 No. (ii) 220 KVA UPS - 01 No.
Notes for item nos. 104, 105 & 106:- (i) ) The cost of all new spare parts which are required for smooth functioning of UPSs, in replacement of old existing defective /unserviceable spare parts /items will be deemed to be included in unit quoted rates. (ii) Cost of any item and extra manpower required for to make the system functional will be deemed to be included in unit quoted rates by the contractor. (iii) The contractor shall attend the urgent complaints of UPS on receipt call at any time round the clock including Sunday and Holiday and the cost of the same will be deemed to be included in unit quoted rates by the contractor. The penalty for non-attending the complaints of UPS up to six hrs shall be @ Rs. Rs.1000.00 per day per complaint. (iv) Maintenance / repair as enumerated above shall be under taken by the manufacturer or their authorized dealer/ rep. (v) The dust cleaning shall be carried out of each UPS in a week. (vi) All electric connections shall be checked regularly for looseness / tightening the same. (vii) Fortnightly periodical maintenance shall be carried out in rotation apart from breakdown for each UPS and record of same to be maintained duly signed by contractor and MES rep. (viii) In case of major defect found in UPS, time being stand by UPS, up to rating 30 KVA will be provided by contractor at his own cost and the rental cost / cost of the same will be deemed to be included in unit quoted rates by the contractor. (ix) Rate quoted by contractor for this item does not include the cost of replacement of battery and panel fan.
S&F in replacement IP-43 protection metal door Vertical TPN DB rated busbar, pan assembly etc. with and including interconnection links, blanking plates, cable ties, identification labels TPN 4 way, 12 modules with provision to mount 125 Amps, MCCB 4 pole as incomer and SP / TP MCB as out going and concealed / fixed on wall / board as required at site including all cutting holes in or through walls, making good to disturbed walls / ceiling surfaces as per existing / by applying two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing, complete all as specified and directed.
Supply and fix in replacement of UPS panel fan of suitable capacity as per existing complete all as directed by Engr-in-charge.
S & F in replacement of 12 volt, 26 AH, SMF battery complete as directed by Engineer-in-charge. Make- Exide/Amaron or equivalent make as approved
S & F in replacement of 12 volt, 42 AH, SMF battery complete as directed by Engineer-in-charge. Make- Exide/Amaron or equivalent make as approved
S & F in replacement of 12 volt, 65 AH, SMF battery complete as directed by Engineer-in-charge. Make- Exide/Amaron or equivalent make as approved
S&F in replacement IP-43 protection metal door Vertical TPN DB rated busbar, pan assembly etc. with and including interconnection links, blanking plates, cable ties, identification labels TPN 8 way, 24 modules with provision to mount 125 Amps, MCCB 4 pole as incomer and SP / TP MCB as out going and concealed / fixed on wall / board as required at site including all cutting holes in or through walls, making good to disturbed walls / ceiling surfaces as per existing / by applying two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing, complete all as specified and directed.
S&F in replacement, IP-43, MCB DB TPN 4 way, double door with bus bars 415 Volts, and concealed / fixed on wall / board as required at site including all cutting holes in or through walls including making good the disturbed surfaces of walls, ceiling etc including two coats of white / colour washing / distempering etc. (as applicable) to the disturbed surfaces to match the existing complete all as specified and directed
S&F in replacement of sheet metal enclosures for SPN DB's 240 volts, factory made double door flush type, IP-42 protection and all as per IS-8623, made from sheet metal 4 way, 200 amps rated bus bar to be fixed with wall including with all accessories complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures for SPN DB's 240 volts, factory made double door flush type, IP-42 protection and all as per IS-8623, made from sheet metal 8 way, 200 amps rated bus bar to be fixed with wall including with all accessories complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosures for SPN DB's 240 volts, factory made double door flush type, IP-42 protection and all as per IS-8623, made from sheet metal 12 way, 200 amps rated bus bar to be fixed with wall including with all accessories complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket with and including one single pole MCB 20 Amps 240 volts including taking down of old unserviceable enclosure complete all as specified and as directed
S&F in replacement MCCB 4 pole 200 Amp, Icu = 16 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos. and proper size of lugs, nuts bolts and washers for proper connections including with MS enclosure of suitable size, complete all as specified and directed.
S&F in replacement MCCB 4 pole 100 Amp, Icu = 16 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos. and proper size of lugs, nuts bolts and washers for proper connections including with MS enclosure of suitable size, complete all as specified and directed.
S&F in repairs cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade from socket / switch to geyser, complete all as specified and as directed.
S&F in repairs flat twin 4 Sqmm with alumanium conductor multi strand black cable as per IS 694-1990, complete all as specified and as directed.
S&F in replacement MCB, SP, 6-32 Amps,10 KA, 'C' series, complete all as specified and directed
S&F in replacement MCB SPN 40 to 63 Amps,10KA, 240V, 'C' series, complete all as specified and directed.
S&F in replacement MCB SPN 6 to 32 Amps,10KA, 240V, 'C' series, complete all as specified and directed.
S&F in replacement MCB TPN 40 to 63 Amps,10KA, 415V, 'C' series, complete all as specified and directed.
S&F in replacement MCCB, 125 Amps 4 pole, 16 KA, 415 Volt, with thermal release, complete all as specified and directed.
S&F new fan motor assembly in replacement of burnt out or unserviceable fan motor assembly complete including with double bearing, copper winding with metal plate top & bottom side suitable for 1200mm sweep in any existing make complete all as specified and as directed by Engr-in-Charge.
M&L for comprehensive preventive and periodical maintenance of OT lights (10 Nos.) installed at OT complex of main bldg of MH AICTS manufacture recommendation, in reliable, safe and efficient manner by using latest techniques & consultancy by regularly examining and adjusting the mechanical & electrical driving equipment with and including S&F of new spare parts in replacement of defective spare parts / items as required for smooth functioning of OT light and as and when required by employing 01 skilled technician having qualification of ITI or diploma in Electrical/ Electronic Engineering having adequate experience including Sunday and holiday complete all as specified and entire satisfaction of Engineer-in-charge.
Notes for item nos. 127:- (i) ) The cost of all new spare parts which are required for smooth functioning of OT lights, in replacement of old existing defective /unserviceable spare parts /items will be deemed to be included in unit quoted rates. (ii) The cost of transportation of OT lights (to and from), skilled manpower & other necessary equipments required for smooth functioning of OT lights shall be arranged / brought by the contractor to complete the job at site only, will be deemed to be included in unit quoted rates. (iii) The contractor shall attend the urgent complaints of OT lights on receipt call at any time round the clock including Sunday and Holiday and the cost of the same will be deemed to be included in unit quoted rates by the contractor. The penalty for non-attending the complaints of OT lights up to six hrs shall be @ Rs. Rs.1000.00 per day per complaint. (iv) Rate quote by contractor for this item does not include replacement of supply unit cluster board, BRL projected lamp and display unit.
S&F in replacement of sterilizable handle suitable for OT Lights of Dr. Mach/ Hospedia makes and testing for its smooth functioning state complete all as directed by Engr-in-charge. Make- Dr. Mach or equivalent as approved
S&F in replacement of cluster board suitable for OT Light of Dr. Mach/ Hospedia makes and testing for its smooth functioning state complete all as directed by Engr-in-charge. Make- Dr. Mach or equivalent as approved.
S&F in replacement of BRL Projection lamp, 12 Volts capacity suitable for OT Lights of Dr. Mach / Hospedia makes and testing for its smooth functioning state complete all as directed by Engr-in-charge. Make- Dr. Mach or equivalent as approved.
S&F in replacement of transformer 0-230V, 0-12 Volts / 500 Va suitable for OT Lights of Dr. Mach/ Hospedia makes and testing for its functioning state complete all as directed by Engr-in-charge. Make- Dr. Mach or equivalent as approved.
S&F in replacement of power supply unit suitable for OT Light of Dr. Mach/ Hospedia makes and testing for its smooth functioning state complete all as directed by Engr-in-charge. Make- Dr. Mach or equivalent as approved.
S&F in replacement of display unit suitable for OT Light of Dr. Mach/ Hospedia makes and testing for its smooth functioning state complete all as directed by Engr-in-charge. Make- Dr. Mach or equivalent as approved.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4 mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) Unit rates includes the cost of 7.50 m GI pipe for protection of 4mm dia GI earth wire for each earthing.
TULAJA ENTERPRISES (BID ID -3089473)
RELIABLE ENTERPRISES (BID ID -3083819)
R R Associates (BID ID -3093604)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .