Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC FOUND LOWEST | |
| 2 | L2₹31.7 L+₹43,729 (1.40%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹32.8 L+₹1.6 L (5.01%)Rejected-AOC H NO 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500015 | HYDERABAD | TELANGANA | 500015 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹32.8 L+₹1.6 L (5.12%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹33.3 L+₹2.0 L (6.54%)Rejected-AOC 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹36.6 L
EMD Value
₹73,200
Closing Date
21 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI MAHAVIR SINGH, IDSE, GE (SOUTH)
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABD
ADDITION / ALTERNATION TO OTM BLDG No T-15 ,T-15A AND T-16 OF EME RECORDS UNDER GE (S) SECUNDERABAD OF GE (S) SECUNDERABAD
2021_MES_489241_2
GE (S)/SEC/TOKEN - 40 OF 2021 - 22
Open Tender
Civil Works
Item Rate
240 days
Secunderabad
For Enlisted contractors class D and above category a (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹73,200
Yes
18 Jun 2022
2 Feb 2022
23 Feb 2022
2 Feb 2022
21 Feb 2022
9 Feb 2022
3 Feb 2022 - 6 Feb 2022
90 days
Amount
Dismantling of single layer mangalore pattern or similar tiles roofing including ridges complete all as specified and as directed.
Dismantling the battens of any size for tiles including tiling fillets spaced exc 15cm c/c complete all as specified and as directed.
Dismantling timber scantling 40 sq cm and over in any position complete all as specified and as directed.
Material and labour for second class hardwood in scantlings clean sawn timber and fixed complete all as specified and as directed.
Material and labour for treating with two coats of creosote oil on new wooden and wood based materials of any description and girth not otherwise described complete all as specified and directed.
Material and labour for treating with one coat of creosote oil on old wooden and wood based materials of any description and girth not otherwise described complete all as specified and directed.
Supply and fix Rolled Mild Steel sections confirming to Fe 410-W(Gde-E- 250) quality-A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as specified and directed.
Supply and fix Pre painted galvalume aluminum zinc coating , GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fix Pre- painted galvalume aluminum zinc coating, GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortar complete all as specified and as directed.
Material and labour for brickwork with fly ash bricks,old size , straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
Material and labour for brickwork with fly ash bricks,old size , straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Material and labour for plain cement concrete 1:2:4 , type B1 (using 20 mm gradded stone aggregate) as in coping complete all as specified and directed.
Taking down cement plaster on brick or stone walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Material and labour for 15 mm thick rendering in CM 1:6 on brick or stone masonry surface including finished even and smooth without using extra cement.complete all as specified and directed.
Material and labour for 15 mm thick rendering in CM (1:4) with water proofing compound on fair faces of brick work or cement concrete surfaces including finish the surface smooth and even complete all as specified and directed . (Note: Water Proofing compound shall be measured and paid for separately).
Supply only integral water proofing compound complete all as specified and directed .
Material and labour for applying two coats of synthetic enamel over a coat of red oxide , zinc chrome primer on new steel surface exc 10 cm width or girth including preperation complete all as specified and directed.
Material and labour for applying two coats of oil bound distemper over a coat of primer and 3 mm thick wall care putty including prepartion of new wall surfaces complete all as specified and directed.
Material and labour for complete removal of existing wall treatment and applying two coats of oil bound distemper over a coat of primer and 3 mm thick wall care putty including preperation complete all as specified and directed.
Material and labour for complete removal of existing treatment including washing/ scrubbing down and applying two coats of cement base paint over a coat of primer on external wall surface complete all as specified and directed.
Material and labour for applying two coats of cement based paint over a coat of primer on new plastered surfaces of wall including preparation complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) not exceeding 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) exceeding 1.5 Sqm and n.exc. 4.00 sqm each complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate ) as in bed blocks etc complete all as specified and directed.
Supply and fix mild steel flat iron as in wind ties for roof, hold fast etc.complete all as specified and directed .
Material and labour for 2nd class hard wood plain, solid, straight chowkats and frames, wrought framed rebated and solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Supply and fix 2 nd class hard wood 35mm thick factory made plain framed, panelled shutter (two panels) with lock rail and pannel of 12mm veneered particle board with comercial veneering on both faces . The size of rail and stile as per IS -1003 (part-I) . Kiln seasond and chemically pressure treated complete all as specified and directed.
Supply and fix 35 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); fitted to chowkats complete all as specified and directed.
Supply and fix steel window with side hung double shutters in single frame . One side shutter to receive glass with glazing bars and to receive gauze on other side shutters including projection type hinges with steel handle on both side shutters and steel peg stay etc .complete all as specified and directed.
Supply and fix mild steel framed work such as grill, gratings, etc with ends of bars shouldered and/or riveted or forged in to spikes, framed guard bars, barred iron doors , ladders , framed balusters and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
Supply and fix steel Ventilators with top hung shutters including hinges , steel peg stay etc. complete all as specified and directed .
Supply and fix 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed .
Supply and fix 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed .
Supply and fix aluminium anodised sliding door bolt with hasp & staple (bolt type) length 300mm complete all as specified and directed.
Suuply and fix 100 mm long mild steel butt hinge , medium weight , cold rolled complete all as specified and directed .
Supply and fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply and fix 3mm thick sheet glass ordinary quality and glazing with oil putty or with wooden beads n.exc 0.50 Sqm each pane in square panels complete all as specified and directed.
Supply and fix 4mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
Material and labour for two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces exceeding 10 CM width or girth complete all as specified and directed.
Dismantaling stone slabs and tiles of any description or thickness in floor ,aprons , laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving n exc 15 cm thickness below and above ground level.complete all as specified and directed.
Material and labour for 75 mm thick plain cement concrete 1:3:6 type C-2 ( using 40 mm graded stone aggregate) , laid in alternate bays not exe. 2.00 Sqm area each with 6mm wide joints filled with mastic filling, including finish the surface even and smooth without using extra cement, as in plinth protection, complete all as specified and as directed.
Material and labour for 75 mm thick plain cement concrete 1:4:8, type D2 ( using 40 mm graded aggregate ) as in sub base of floor complete all as specified and as directed.
Material and labour for 20-25mm thick Machine cut kota stone slab flooring laid over 20 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Material and labour for 20-25mm thick Machine cut kota stone slab laid over 15mm thick rendering in CM 1:4 as in skirting/ dados etc including rubbing and polishing complete all as specified and directed.
Material and labour for Chequered cement concrete tiles 30cm x 30cm x 25 mm thick laid over 20 mm thick screed bed in CM 1:6 including set & jointed with white cement & pigment and pointed in colour / white cement to match the shade of tile complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre /pulp/ insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets complete all as specified and as directed.
Supply and fix GI frame work for seamless ceiling suspension system with perimeter channel 0.55 mm thick having web of 27 mm and flange of 30 mm on one end and 20 mm on other end fixed to walls with the help of nylon sleeves and screws at 610 mm C/C ,intermidiate channel 0.90 mm thick having web of 45 mm and flange of 15 mm on each side suspended from ceiling @ 1200 mm C/C with GI angle 25X10X0.55 mm to be fixed to soffit with GI Cleat and steel suspension fastener , connecting member 0.55 mm thick having knurled web of 51.5 mm and flange of 26 mm on both ends to be connected @ spacing of 450mm including hangers 6 mm dia GI ( upto 1200 mm length ) adjusting level fixed to roof structures complete all as per manufacturer's instructions .
Supply and fix Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions with applying two coats of oil bound distemper over a coat of primer on ceiling surface including preperation complete all as specified and as directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified & directed by Engg in Charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M & L for Point wiring in Concealed conduit in wall with 1.5 Sq mm copper conductor single core PVC insulated cable FRLS type 1100 V grade multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified for: one light point controlled by one, one way switch 5A, SP
All as per item 53 above but for one ceiling / exhaust fan point controlled by one, one way switch
All as per item 53 above but for one bell point controlled by one bell push
All as per item 53 above but for one 2/3 pin 5 Amps socket outlet point controlled by one switch on the same board.
All as per item 53 above but for one 3 Pin 5 Amps switch socket Independt board
All as per item No 53 here-in-before but using 4 Sq mm single core copper conductor cable multistranded PVC insulated FRLS 1100 Volts grade for 6/16 Amps switch socket combination point including running of 4.00 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S & F in repair Switch piano type single pole one way flush type 5 Amps capacity 230 volts.
Supply and fix in repair switch socket combination flush type multipurpose 2/3 pin 5 Amps, 230 Volts complete all as specified.
Supply and fix in repair socket outlet flush type multipurpose 2/3 pin 5 amps, 230 volts all as specified.
Supply and fix in repair switch socket combination flush type multipurpose 5 in 1, 5/16 Amps, 230 Volts complete all as specified.
S&F in repair Bell push one way flush type 5 Amps capacity 230 volts.
S&F Ceiling fan regulator step type AC 240 volts suitable for 1200/1400 mm sweep.
S & F in repair ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
S&F in repair wall mounted box type fitting suitable for LED of 18/22 watt extruded aluminium heat sink provided for efficent heat dissipation including LED lamp complete all as specified and directed by Engr-in-Charge.
Supply and in repair fix 9/10 W LED batten along with integrated driver complete all as specified and directed by Engr-in-Charge.
S&F in repair lamp holder insulated body surface bakelite including LED lamp of 7 watt with back plate suitable for angle/batten fittings fixed with PVC round blocks all specified.
S&F bell ding dong working on 230 volts AC supply.
S & F in repair Vertical type TPN DB 4 way double door with 200 Amps rated bus bar 415 volts AC 3 phase 50 Hz suitable for and including 100 Amps TPN 25 KA as incomer and 12 outgoing SP MCB's with fixed magnetic setting with locking arrangement complete all as specified and directed.
S & F in repair Sheet metal enclusure MCB DB SPN 8 way double door with 200A rated bus bar 240V double door with flush type locking system complete all as specified.
S & F in repair MCB SP 6 to 32 Amps 240 volts for fixing in MCB DB's all as specified.
S & F in repair MCB SPN 40 Amps 240 volts for fixing in MCB DB's all as specified.
M & L in repair / replacement for Submain wiring with two single core 6 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up two one of 6 Sq mm copper conductor multistranded PVC insulated FRLS cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
M & L in repair / replacement for Submain wiring with two single core 10 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up two one of 6 Sq mm copper conductor multistranded PVC insulated FRLS cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom of required length with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate).
Disconnecting and removing ceiling fan of 1200/1400 mm sweep from any height bringing down, dismantling, cleaning internally and externally, thoroughly examine, rewinding, repainting it white, replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan.
SAMBASIVA RAO
M/S C MALLIAH & SONS
LAKSHMI ENGINEERS
ATUL ENTERPRISES
K LAKSHMAN SINGH AND CO
M/S DIVIJA BUILDERS
Sri Associates
SAI RUPA CONSTRUCTIONS
BEEGEE DESIGN SYSTEMS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .