Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
6 Oct 2026, 6:00 pm
The Director
ICAR-NBSSLUP, Nagpur
Repairing of Existing Research Building
2026_DARE_924329_1
16-47/works/2023
Open Tender
Civil Works
Works
ICAR-NBSSLUP
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹1 L
Yes
15 Sept 2026
15 Sept 2026
8 Oct 2026
15 Sept 2026
6 Oct 2026
15 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1Repairing of Existing Research Building at ICAR-NBSS&LUP, Nagpur | ||||||
| 1.01 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. | 236.13 | cum | - | - | 18% |
| 1.02 | Waterproofing treatment to terrace by using chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge, followed by average 112mm thick brick bat coba covered with 40mm thick IPS.
The procedure includes filling of cracks on the RCC slab with high performance polyurethane (liquid applied) membrane. Clean the entire surface thoroughly and over this prepared surface, apply a primer coat of high performance polyurethane (liquid applied) membrane as approved by Engineer in charge. Apply the primer by roller. Extend the coating to parapet walls including the top of parapet. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge on surface. Ensure that pinholes are touched up properly. While the second coat of high performance polyurethane (liquid applied) membrane is wet and tacky, sprinkle coarse sand over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 15 mm thk protective coat of CM in 1:4 over the surface and allow to set and cure. Provide and lay 112 mm thk BB coba in average thickness in cement mortar 1:5 with one pouch of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents - which is based on special cements, aldehyde based polymers, shrinkage compensating agents and selected sands having high abrasion resistance as approved by Engineer in charge per 50 Kg bag of cement and finishing with 40 mm thick IPS layer in M-20 CC by mixing one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents per 50 Kg bag of cement, including all leads, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatment with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. The liquid membrane should have a track record of atleast 4 years in India & Gulf region and have atleast an 4 year track record in PWD. Single Component, Liquid Applied, chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane should have following minimum properties: 1) Water Permeability (DIN 1048): Nil as per DIN 1048 @ 7 bar of Hydrostatic Pressure. 2) Moisture Permeability: < 0.4 g/m2/day 3) Accelerated Weathering (IS 101): 2000 hrs No cracking or blister formation 4) Adhesion to concrete (ASTM D 1000): >21 Kg/cm2 (Concrete Fails) 5) Tensile Strength: > 2.0 MPa (ASTM D412) 6) Should not be water soluble or water dilutable 7) Shore A Hardness: 40 ± 5 (ASTM D2240) 8) Elongation at Break: > 900 % (ASTM D412) 9) Solids: > 95 % 10) No micro-bubble formation or blistering should take place during the curing of thick films. | 897 | sqm | - | - | 18% |
| 1.03 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. | 1,040.65 | sqm | - | - | 18% |
| 1.04 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes.ASTM D - 1785 & ASTM D 2466 All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. | 439.2 | running meter | - | - | 18% |
| 1.05 | Providing & Applying chemical for cleaning the exposed steel structure, TMT bars, etc. of structure by grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal also removing loose particles, of the area by water jet, (using other mechanical / manual means) and apply on prepared surface of as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturer's specification ( using other manual / mechinical means) after that Providing and applying high abrasive resistant, self curing, UV resistant,impermeable ,high strength, non shrink, Poly Ironite Ceramic Cementatious (PICC) repair mortar resurfacing on concrete surface of thickness up to 10 mm including breaking honey comb area, (using manual/mechanical means) , clean the concrete surface with special chemical clonon with pressure water jet for removing of algae fungi, apply bond coat Kelox water misible epoxy before PICC application with all leads and lifts, Material, Machinery, labour, scaffolding, etc. complete as per specification and as directed by engineer-in-charge. | 8.64 | sqm | - | - | 18% |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_972672.xls
BOQ • 0.39 MB
LayoutPlanUpload.pdf
Additional Documents • 0.78 MB
Checklist.pdf
Additional Documents • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .