| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-Finance | ₹2.4 L | L1 | Accepted-Finance Bidder is L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Bidder is not L1 Bidder |
| 3 | Rejected-Technical WARD NO22 127 GHARAULI KALA KAMARI MATA MANDIR GALI NIGAHI WAIDHAN M P | WAIDHAN | SINGRAULI | MADHYA PRADESH | - | - | Rejected-Technical Bidder is not L1 Bidder |
| 4 | Rejected-Technical 00 BHADAR TIKARMAFI BAZAR SULTANPUR UTTAR PRADESH 227413 | AMETHI | UTTAR PRADESH | 227413 | - | - | Rejected-Technical Bidder is not L1 Bidder |
| 5 | Rejected-Technical 0 BHAGYODAY BUILDING BANK MORE DHANSAR ROAD DHANBAD JHARKHAND 826001 UDYAM JH 04 0034614 | DHANBAD | JHARKHAND | 826001 | - | - | Rejected-Technical Bidder is not L1 Bidder |
| Sl No | Description | Qty | Unit | BHASKAR ENTERPRISES L2 | SHREYA ELECTRICAL L1 | M/s. Dev Enterprises L5 | PRABHA ENTERPRISES L3 | ITAUHA BROTHERS AND GROUP L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing, installation and testing of slim, compact, auminum die cast edge LED 2*2 panel. Recess mounted square fixture with opel diffuser and separate electronic driver. 36/40 Watt LED 6500 K (Ceiling outcut {583*583 MM} +-1MM) | 13 | Nos. | 1,410 ₹18,330 | 1,550 ₹20,150 | 1,800 ₹23,400 | 1,600 ₹20,800 | 2,800 ₹36,400 |
| 2.00 | Providing, installation and testing of slimmestrecess com surface round / square LED panel for installation in recess. 20 Watt LED 6000 K | 210 | Nos. | 750 ₹1.6 L | 707.2 ₹1.5 L | 900 ₹1.9 L | 850 ₹1.8 L | 719 ₹1.5 L |
| 3.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group -C) | 35 | points | 780 ₹27,300 | 450 ₹15,750 | 500 ₹17,500 | 330 ₹11,550 | 179 ₹6,265 |
| 4.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 28 | Mtr. | 185 ₹5,180 | 150 ₹4,200 | 150 ₹4,200 | 130 ₹3,640 | 189 ₹5,292 |
| 5.00 | Supplying and fixing of following wayssingle pole and netutal, sheet steel, MCB distribution board 240 Volts, on surface/ recesstinned copper bus bar, neutral bus bar, earth bar, din bar intrconnection, powder painted including earhing eyc. as required .(But without MCB/RCCB/Isolator) 6 Way. Double door | 4 | No | 1,250 ₹5,000 | 802 ₹3,208 | 1,500 ₹6,000 | 1,600 ₹6,400 | 1,289 ₹5,156 |
| 6.00 | Supplying and fixing 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole | 26 | Nos. | 143 ₹3,718 | 190 ₹4,940 | 180 ₹4,680 | 120 ₹3,120 | 1,310 ₹34,060 |
| 7.00 | Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole | 4 | Nos. | 300 ₹1,200 | 954 ₹3,816 | 1,200 ₹4,800 | 400 ₹1,600 | 1,389 ₹5,556 |
| 8.00 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A | 1 | Nos. | 705 ₹705 | 1,004.5 ₹1,004.50 | 1,200 ₹1,200 | 7,500 ₹7,500 | 1,450 ₹1,450 |
| 9.00 | Total impact of GST for the purpose of CTC | 1 | Nos | 39,407.94 ₹39,407.94 | 36,284.49 ₹36,284.49 | 45,140.4 ₹45,140.40 | 41,959.8 ₹41,959.80 | 44,130.42 ₹44,130.42 |
Tender Value
₹3.6 L
EMD Value
₹4,600
Closing Date
19 Jun 2025, 11:00 amClosed
STAFF OFFICER ENM
CENTRAL WORKSHOP JAYANT PO JAYANT DIST SINGRAULI, M.P. 486890
Rearrangement of ceiling mounted LED light fittings of Officers Club, Ladies Lounge, Indira Bhawan and Workers Club at CWS Colony, Jayant.
2025_NCL_336962_1
NCL/CWS/ENM/Tender/25-26/08 DTD 03.06.2025
Open Tender
Electrical and Maintenance Works
10 days
CWS COLONY JAYANT
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,600
11 Feb 2026
5 Jun 2025
20 Jun 2025
5 Jun 2025
19 Jun 2025
5 Jun 2025
5 Jun 2025 - 12 Jun 2025
Amount
Providing, installation and testing of slim, compact, auminum die cast edge LED 2*2 panel. Recess mounted square fixture with opel diffuser and separate electronic driver. 36/40 Watt LED 6500 K (Ceiling outcut {583*583 MM} +-1MM)
Providing, installation and testing of slimmestrecess com surface round / square LED panel for installation in recess. 20 Watt LED 6000 K
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group -C)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following wayssingle pole and netutal, sheet steel, MCB distribution board 240 Volts, on surface/ recesstinned copper bus bar, neutral bus bar, earth bar, din bar intrconnection, powder painted including earhing eyc. as required .(But without MCB/RCCB/Isolator) 6 Way. Double door
Supplying and fixing 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A
Total impact of GST for the purpose of CTC
BHASKAR ENTERPRISES (BID ID -1161497)
PRABHA ENTERPRISES (BID ID -1161750)
ITAUHA BROTHERS AND GROUP (BID ID -1161634)
M/s. Dev Enterprises (BID ID -1161620)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid