CE/D/Erode
Chief Engineer/Distribution/ Erode Region, Erode
Construction of control room building with electrification and providing plinth foundation for various structures etc for establishment of new Kodumanal 33/11 KV SS with 8MVA power transformer at Punjaipaalathozhu at Erode EDC,Erode
2025_EB_629108_1
CE/D/ED/Spec.No.12/2025-2026
Open Tender
Civil Works
Works
365 days
Erode
As per BQR Conditions
2 documents required · 2 mandatory
₹0
₹2.0 L
Yes
27 Jan 2026
5 Dec 2025
23 Dec 2025
8 Dec 2025
22 Dec 2025
16 Dec 2025
9 Dec 2025 - 15 Dec 2025
Schedule I -Civil
GST Amount (Total GST Amount @18%)
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
Clearing Juliflora jungles with uprooting and disposed away from the site as per the direction of site engineer including cost of all labour, lead, lift, etc., complete
Cutting , filling and levelling of earth soil in open excavation of hard stiff clay, stiff black cotton hard red earth, shales, muram, gravel, stoney earth and earth mixed with small size boulders and depositing the excavated earth 100m lead including intial lead of 10m and lift of 2m complete as directed by the Engineer in charge
Supply and filling a gravel soil by collection, stacking and spreading in the yard area with compacted by power roller including cost of all materials, lead, lift, labour, etc., complete as per the direction of site engineer.
Earth work excavating and depositing on bank with initial lead of 10 m & initial lift of 2m in Hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders including all labour charges, lead, lift, T&Ps etc., complete as directed by the Engineer in charge.
Earth work excavating and depositing on bank with initial lead of 10 m & initial lift of 2m in soft disintegrated rock, lateritie soft rock or Kankar not requring blasting including all labour charges, lead, lift, T&Ps etc., complete as directed by the Engineer in charge.
Earth work excavating and depositing on bank with initial lead of 10 m & initial lift of 2m in medium and dense medium rock not requiring blasting for foundation including all labour charges, lead, lift, T&Ps etc., complete as directed by the Engineer in charge.
Providing Anti termite pre construction treatment using emulsifiable concentrate of required percentage as suggested by the manufacture and specification as per 6313 part II - 1971 around Excavated Area, Plinth, Foundation and Basement in four stages as directed by the Engineer at Site including cost of all materials, lead,lift etc., complete.
Supplying and filling M sand (Approved quarry) well watered and consolidated in foundation and basement in layers complying with standard specification,including cost of all materials, all labour charges, lead, lift, T&Ps etc., complete as directed by the Engineer in charge.
Providing Plain Cement Concrete in 1:3:6 for basement foundation using OPC 53 grade cement (DALMIA/ ULTRATECH/RAMCO) ,M sand , 40mm HBG metal including cost of cement, all materials, labour charges, curing, all leads, lifts, as per standard specification etc., complete as directed by the Engineer in charge.
Providing Plain Cement Concrete in 1:2:4 using OPC 53 grade cement (DALMIA/ ULTRATECH/RAMCO) of 12 to 20mm metal for support plinth structures without formwork including cost of all materials, labour lead, lift, etc., complete as directed by the Engineer in charge.
Providing Plain Cement Concrete in 1:2:4 using OPC 53 grade cement (DALMIA/ ULTRATECH/RAMCO) of 12 to 20mm metal (machine crushed) for plinth support structures with formwork including cost of all materials, labour lead, lift, etc., complete as directed by the Engineer in charge.
Providing Reinforced cement concrete (RCC) 1:2:4 using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for raft foundation including cost of all materials,water charges,shuttering charges, labour lead, lift, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for Culvert/Transformer plinth and other structures including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for Column upto basement with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for Column above basement with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for Grade beam with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for Plinth beam with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for Lintel with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½ :3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for Sunshade and Loft with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½ :3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for Roof beam with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for Roof slab 130 mm thick with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for Precast cover slab with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Providing Wet mix macadam (WMM) mix using 40mm HBS machine crushed metal for formation of road including cost of all labour, materials, lead, lift, curing, etc., complete as directed by the Engineer in charge.
Providing Reinforced cement concrete (RCC) in 1:1½:3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal for formation of Road including cost of cement, all materials, side shuttering, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc.,complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.)
Brick work in CM 1:5 using IInd class chamber burnt bricks (230x110x75mm),OPC 53 grade cement (DALMIA/ULTRATECH/RAMCO),M sand for basement including cost of all materials, scaffolding, labour charges, curing, lead, lift, T&P, etc., complete as directed by the Engineer in charge.
Brick work in CM 1:5 using IInd class chamber burnt bricks (230x110x75mm),OPC 53 grade cement (DALMIA/ULTRATECH/RAMCO),M sand for super structure and other structures including cost of all materials, scaffolding, labour charges, curing, lead, lift, T&P, etc., complete as directed by the Engineer in charge.
Supplying and filling of Gravel in the basement filling, labour for filling, watering and consolidation, including cost of all materials, lead, lifts, labour, etc., complete as directed by the Engineer in charge.
Providing steel reinforcement for RCC works using Fe 550 TMT bars (TATA/SAIL/JSW/VIZAG) having for all RCC works including cutting, bending, binding, tying and placing in position including cost of steel, galvanized binding wire, lead, lift and etc., complete as directed by the Engineer in charge .
Supply and fixing of 90lbs rails in transformer plinth including cost of material , transport charges,fixing charges,lead,lift, etc., complete as directed by the Engineer in charge.
Random rubble masonry in CM1:6 for foundation, basement and compound wall including cost of all materials ,scaffolding,lead,lift,etc,complete as directed by the Engineer in charge.
Providing projected border of 7.50cm width on top of parapet wall in CM 1:3 mix 12mm thick including cost of all material labour, lead, lift, curing etc., complete as directed by the Engineer in charge .
Providing projected border of 20cm. width for plinth beam in CM. 1:3 20mm thick including cost of all materials, labour, lead, lift, etc., complete as directed by the Engineer in charge .
Plastering in CM 1:5, 12mm thick using OPC 53 grade cement (DALMIA/ ULTRATECH / RAMCO), P sand approved quarry for all wall surfaces,etc., including cost of all materials, scaffolding charges, Labour charges, curing, lead, lift, T&P etc., complete as directed by the Engineer in charge.
Plastering in CM 1:3, 12mm thick using OPC 53 grade cement (DALMIA/ ULTRATECH / RAMCO) , P sand for ceiling, beams, sunshade ,lofts,Plinth structure,cable duct,cuilvert, etc.,including cost of cement, all materials,curing, labour, lead and lift etc., complete as directed by the Engineer in charge.
Providing P.C.C. 1:2:4 using OPC 53 grade cement (DALMIA/ ULTRATECH/RAMCO),M sand ,6mm to 10mm HBG metal (Approved quarry) by placing with Weld mesh 10 x 10 cm 10 Gauge over the roof slab , including cost of all materials, labour charges, curing, T&P, lead, lift etc., complete as directed by the Engineer in charge.
Supply,fabrication and Labour charges for fixing of various sizes of GI angles to the required length for supporting the cable in the cable duct in correct position including labour charges,cutting ,painting with two coat enamel paint over with one coat primer,lead,lift,etc., complete as per the drawing and std.specification.
Supplying and fixing in position of MS grill gate including cost of all materials, lead, lift, etc. as per type design drawing with proper locking arrangements as directed by the engineer at site including cost of painting with two coats of enamel paint over with one coat of red oxide primer in complete as directed by the Engineer in charge.
Supplying and laying UPVC pipe 100 mm outer dia (Schedule 40) ISI make including cost of UPVC pipe, labour for cutting laying fixing etc., in complete as directed by the Engineer in charge.
Provision of one Load of Msand at the substation including cost of Material and transport charges etc (One load)in complete as directed by the Engineer in charge.
Provision of Sand drum for the each power transformer cost of Material and transport charges etc
Supplying and filling of stone chips 12 mm to 20 mm HBG metal with required thickness all lead and lift including and all other T&P etc., complete as directed by the Engineer in charge.
Supplying and filling of stone dust with required thickness all lead and lift including and all other T&P etc., complete as directed by the Engineer in charge.
Supply and laying of PVC pipe 40mm dia of 10kgs/cm2 (FINOLEX/ ASTRAL/ SUPREME) approved make and quality with ISI monogram including cost of all materials, all specials such as Tees, Elbow, shoes, Special clamps, bends and screws, gratings etc., making holes in masonry/concrete, restoring the disturbed area to original condition, making water tight jointing with no leakage, labour, scaffolding, lead, lift etc., complete as directed by the Engineer in charge.
Providing and fixing sanitary fitting consisting of Neycer / parryware of European Water Closet with "P" or "S" Trap with Double Flapped Seat and Seat Cover with Brass Hinges and 10 litre capacity PVC Low Level Flusing Tank with all internal fittings including cost of all material, labour, lead, lift, etc, complete as directed by the Engineer in charge.
Providing and fixing sanitary fitting consisting of Neycer / parryware of Oriya patten Water Closet 45cm wit
h P/S trap connecting with PVC ventilating shaft and Y bend complete, including cost of all material, labour, lead, lift, etc, complete as directed by the Engineer in charge.
Interior colour washing with two coats using ready mixed Weather Proof Emulsion (First quality - Asian paint ultima or its equivalent) of approved quality over a coat of exterior emulsion water based primer in surfaces and with two coats of wall putty ,including clean removal of dirt, cost of all materials, scaffolding, labour, lead, lift etc.,complete as directed by the Engineer in charge.
White washing two coats with White cement approved quality over a primary coat for ceiling, exposed surfaces of wall, beam, slab, sunshade,lofts, lintel, etc., including cost of all materials, lead, lift, etc.,complete as directed by the Engineer in charge.
Exterior colour washing with two coats using ready mixed Weather Proof Emulsion (First quality - Asian paint ultima or its equivalent) of approved quality over a coat of exterior emulsion water based primer in surfaces ,including clean removal of dirt, cost of all materials, scaffolding, labour, lead, lift etc.,complete as directed by the Engineer in charge.
Supplying and fixing 40mm dia Heavy Gate valve (LEADER/ZOLOTO) of approved quality including cost of all materials, labour charges for fixing, lead, lift etc.,complete as directed by the Engineer in charge.
Supplying and fixing 32mm dia Heavy Gate valve (LEADER/ZOLOTO) of approved quality including cost of all materials, labour charges for fixing, lead, lift etc.,complete as directed by the Engineer in charge.
Supplying and fixing 20mm dia Heavy Gate valve (LEADER/ZOLOTO) of approved quality including cost of all materials, labour charges for fixing, lead, lift etc., complete as directed by the Engineer in charge.
Labour charges for writing Name Board/Slogans over the plastered surface wall including cost of paint & all materials, labour, lead, lift, etc., complete as directed by the Engineer in charge.
Supplying and fixing of two side polished 30mm tk.cuddapah slab for cupboard etc., including cost of all materials, labour, lead, lift, etc., complete as directed by the Engineer in charge.
Providing inspection chamber for sufficient intervels throughout the line 0.45x0.45m. Size and 0.6x0.6m size to a depth as below with proper gradient of the sewerline and BW. in CM 1:5 with CI. cover at top and bottom foundation PCC 1:3:6 using 40mm metal plastering with CM1:3 12mm thick and all lead, lift etc.complete as directed by the Engineer in charge.
Supplying and laying PVC pipe 110 mm outer dia 6kg/ cm2 ISI make for laying the sewer line including cost of pvc pipe coupling labour for cutting, laying, fixing and tightening etc including earth work excavation and refilling trench etc., complete as directed by the Engineer in charge.
Supplying and filling 20mm HBS metal for dispersion trench per standard specification including cost of all materials, lead lift etc. complete as directed by the Engineer in charge.
Supplying and fixing of 110mm dia PVC pipe, cowl for ventilating shaft., to a height of 10' length with proper B.W. with C.M.1:5mix plastering 12mm thick including cost of all materials, lead, lift etc. complete as directed by the Engineer in charge.
Flooring with available sizes of approved quality,design & colour (Johnson or equivalent make) of non-slippery ceramic tiles laid in cement mortar 1:3 -20mm thick including pointing with same coloured cement using 0.4kg/sqm, finishing the joints, including cost of all materials, labour, lead, lift, etc. complete as directed by the Engineer in charge.
Providing floor finish with Double Charged Vitrified tiles of approved size, make(Kajaria/Johnson or its equivalent), colour and pattern over 10mm thick Cement mortar 1:3 for bedding and pointing same coloured cement in all floors , including cutting chase in walls wherever required, cost of all materials labour charges lead, lift, curing T&P etc., complete as directed by the Engineer in charge.
Dadooding walls with approved quality of glazed tiles, size and design (Kajaria/Johnson or its equivalent), laid in cement mortar 1:2 -10mm thick including pointing with same coloured cement using 0.4kg/sqm, finishing the joint sand pointing flush with the tile surface , including cost of all materials, labour, lead, lift, etc. complete as directed by the Engineer in charge.
Flooring with approved acid proof tiles over cement mortor 1:3 20mm thick in floor including pointing with white cement finishing the joints flush pointing the surface etc complete as directed by the Engineer in charge.
Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (UPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced alround with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.The Door should be got approved from the Executive Engineer before use on work including all cost of materials,hydraulic closer,lead,lift,transport and etc.,complete as directed by the Engineer in charge.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work including cost of all materials , lead, lift , etc. complete as directed by the Engineer in charge.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 8mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (blackcolour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned. Radiations pin headed or Pin headed/Fluted/Figured glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon pac
king all round the frames.The ventilator should be got approved from the Executive Engineer befoe use on work and as per specications .complete as directed by the Engineer in charge.
Supplying and fixing of wash basin of size 550 x 400 mm of approved quality neycer / parrys ISI including cost of wash basin with pedastal cock fixing using rag bolt and nut 15mm dia pvc connecting hose and outlet using 50mm dia pvc waste water pipe for outlet cp angle valve with all accessories including cost of all materials, labour, lead, lift, etc., complete as directed by the Engineer in charge.
Supplying and fixing of 15mm high quality brass Chromium plated screw down bib cock (Heavy Type) such as leader, zeolite and zenith of any other approved quality cost of all materials, labour, lead, lift, etc., complete as directed by the Engineer in charge.
Supplying and fixing in position sun control polyester flim, reflective type 75 microns thick, gareware or equivalent including the cost of all materials, labour, lead, lift, T&P etc. complete as directed by the Engineer in charge.
Supplying and Providing PVC 4 layer tank (SINTEX/ ASHIRVAD/SUPREME) 1000Lit of approved quality and make including necessary inlet, outlet, over flow and drain line fixing accessories / fitting, cost of all materials, labour charges for fixing, lead, lift etc., complete as directed by the Engineer in charge.
Supplying and fixing Digital wall clock 1 No, floor mat- 4 Nos., water bucket with mug in large and small sizes each - 2 sets for toilet room of approved make and quality including the cost of all materials, leads, lifts etc., complete as directed by the Engineer in charge.
Supplying and fixing 100 x 50mm Stainless steel floor trap in bath room including cost of all lead,lift, etc., complete as directed by the Engineer in charge.
Supplying and fixing 110mm dia PVC.Bend including cost of materials, labour lead lift, etc. complete as directed by the Engineer in charge.
Supplying and fixing 110mm dia PVC TEE including cost of materials, labour lead lift, etc. complete as directed by the Engineer in charge.
Supply and erection of 20 mm PVC Tap for earth pits including cost of materials, labour lead lift, etc. complete as directed by the Engineer in charge
Charges for geophysical survey for invetigation of borewell point at various location in the SS site
Drilling bore well of 150mm dia 6” in all soils, hard rock etc., including transporting of machineries with equipments and all necessary T & P’s labour etc.,complete as per specification -Upto 0- 100 Mts
Drilling bore well of 150mm dia 6” in all soils, hard rock etc., including transporting of machineries with equipments and all necessary T & P’s labouretc.,complete as per specification -Upto 100-300Mts
Supply and erection of 180mm (7”) dia rigid PVC casing pipe, having 6kg/cm² including cost all materials,lead, lift, re-boring the holes to required depth etc., complete with cover at the top of the bore well.
Supplying and erection of 3HP Submergible TEXMO AQUA 100mm or its equivalent motor pump set of required Stage of approved quality and make as per ISI specification , including cost of all materials, lifts, labour charges and including transportation charges, required accessories, assembling charges, erection charges etc., but excluding cost of cables.complete as directed by the Engineer in charge.
Supplying and fixing of 3 phase panel board (L&T or its equivalent) with Automatic electronic starter of star - Delta connection to suit bore submergible pumpset of 5 HP of approved quality and make as directed by the Engineer at site including cost of starter, leads, lifts, labour charges and fixing charges, transportation charges and testing charges. etc. complete as directed by the Engineer in charge.
Supply and erection of 50 mm dia UPVC pipe for borewell having ISI mark of Schedule 80 Finolex/Supreme/Ashirvad pipes as per IS 4985 2000 and handling high pressure schedule 80 and as per site standard specifications and site requrement for in and outside of the bore well including cost of all materials, labour, lead,lift etc., complete as directed by the Engineer in charge.
Supply and erection of 40 mm dia UPVC pipe for borewell having ISI mark of Schedule 80 Finolex/Supreme/Ashirvad pipes as per IS 4985 2000 and handling high pressure schedule 80 and as per site standard specifications and site requrement for in and outside of the bore well including cost of all materials, labour, lead,lift etc., complete as directed by the Engineer in charge.
Supply and erection of 32 mm dia UPVC pipe for borewell having ISI mark of Schedule 80 Finolex/Supreme/Ashirvad pipes as per IS 4985 2000 and handling high pressure schedule 80 and as per site standard specifications and site requrement for in and outside of the bore well including cost of all materials, labour, lead,lift etc., complete as directed by the Engineer in charge.
Supplying and fixing of non return value (LEADER/ZOLOTO) of 50/40/32mm dia and required specials such as GI pipes, Unions, and bends etc., of approved quality and make as directed by the Engineer incharge at including cost of all NRV, leads, lifts, labour charges etc., complete as directed by the Engineer in charge.
Supply,fabrication and Labour charges for fixing of various sizes of MS Channels/Angles to the required length for supporting in correct position including labour charges,cutting ,painting with two coat enamel paint over with one coat primer,lead,lift,etc., complete as per the drawing and std.specification.
Supplying and laying of 4 Core 6 sq.mm PVC armoured cable of FINOLEX/RR/CRI ISI make suitable for submergible motor and approved quality for borewell including cost of all cables, copper wire/ropes for binding, leads, lifts, transportation charges, etc, complete as directed by the Engineer in charge.
Supplying and fixing of horizontal type 4 Way Triple Pole neutral MCB Distribution board in sheet steel enclosure distribution board with double door (metal) with RCCB-1No,40A FP Isolator (MCB), as incoming and 12 Nos 6A - 32A single pole MCB as out going in flush with wall and making good of the concelled portion with earth connection. The 40AFP ,RCCB and MCBs should be with ISI mark (Legrand /(L&T) make including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge.
Wiring with 3 x 2.5 sqmm (36/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling for lights, fan and buzzers with PVC accessories in wall with heavy metal switch box and 5A modular switches with continuous earthing for providing 2.5 Sq.mm multistrand PVC wire of PVC light point / Fan point with 5amps switch, ceiling rose, cable, pipe, etc., The wiring should be Finolex or its equivalent make and Switch box/Switches should be Legrand/MK/equivalent with ISI mark including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge. For light and Fan points
Wiring with 3 x 2.5 sqmm (36/0.3) PVC insulated SC unsheathed copper conductor of cable 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flu
sh with wall Metal switch box with 5A 3 pin modular type non interlocking CS plug with continuous earthing for providing 2.5 Sq.mm multistrand PVC wire for making good of concealed portion with suitable color for concealed PVC plug point cable, pipe, etc., The wiring should be Finolex or its equivalent make and switch box should be Legrand/MK/Schneider make with ISI mark including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge.
Supply and fixing of 20W 4 Feet LED Fitting of Higher end (Philips/ Havells or equivalent make) as approved by the engineer incharge at site with MS round blocks on wall or ceiling with PVC unsheathed copper lead from terminals to the fittings including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge.
Wiring with 3 x 4 sqmm (56/0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with Metal switch box with 16A 3 pin Modular type non interlocking CS plug with continuous earthing for providing 4 Sq.mm multistand PVC wire for making good of concealed portion with suitable color for concealed PVC plug point . The wiring should be Finolex or its equivalent make and switch box should be Legrand/MK/Schneider make with ISI mark including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge.
Supplying and fixing of 23 cm angular holder with EI fancy shade glass with 9 W LED bulb including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge.
Supply and fixing of 1400mm (56") AC ceiling fan confirming to ISS 374 /1979 (Bajaj / Crompton / Usha/Orient) complete with stepped electronic square modular type regulator with required down rod on the existing clamp including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge.
Supplying and fixing of 4'40W twin street light (Philips / Havells /equivalent make) fluorescent fitting complete with choke and condenser with 32mm dia GI pipe (Class 'B') with 1 No 32mm GI bend complete on the existing post wall with 16A aerial fuse unit of MS plate with PVC unsheathed FRLS copper leads MS clamps and aluminium painting with fluorescent tubes in complete as directed by the Engineer in charge.
Supplying and fixing of 375mm (15') sweep heavy duty AC Exhaust fan with MS/Fibre louvers shutters arrangements of approved ISI quality complete with necessary wall opening and making good of the wall in complete as directed by the Engineer in charge.
Earthing as per PWD standard with an earth electrode of 2M class B GI pipe of dia not less than 32mm complete with neceesary masonry work including cost of all materials, labour, lead, lift, etc., complete as directed by the Engineer in charge.
Supplying and fixing of best approved quality of Brass Chromium plated towel rod of size 90cm and soap tray size 150x150mm in bath room including cost of all materials, lead, lift, etc., complete.
Supplying and run of 4 of 6 Sqmm (84/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade with necessary reels in suitable PVC rigid pipe concealed in wall and ceiling with continuous earthing for providing 6 Sq.mm multistand PVC wire .The cable/wiring should be Finolex /RR or equivalent make with ISI mark including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge.
Supplying, fabricating and placing in position of M.S 12mm square bar windows including cost of painting with two coats of enamel paint over with one coat of red oxide primer and including cost of all materials, labour charges, lead, lift etc complete as directed by the department engineer at site.
Assembling of various plinth templates for providing concrete including transporting from one plinth to another, alingning fixing to corrrect level and dismatling the templete after concreting including cost of labour, cost of template, lead, lift, etc., complete.
Supply and fabrication of grouting bolt including cutting, bending, threading, 1200 mm length with galvanized and providing 2 Nos nuts with washer etc and fixing them in plinth including cost of materials labour,lead ,lift,etc, complete as per standard specification.
Supply and laying of PVC pipe 32mm dia of 10kgs/cm2 (FINOLEX/ ASTRAL/ SUPREME) approved make and quality with ISI monogram including cost of all materials, all specials such as Tees, Elbow, shoes, Special clamps, bends and screws, gratings etc., making holes in masonry/concrete, restoring the disturbed area to original condition, making water tight jointing with no leakage, labour, scaffolding, lead, lift etc., complete as directed by the Engineer in charge.
Supply of furnitures manufacture including cost of all materials, labour,lead and lift etc., complete as directed by the Enginer at site -S Type chair with nylon seated
Supply of furnitures manufacture including cost of all materials, labour,lead and lift etc., complete as directed by the Enginer at site.- Steel side rack open type
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.92 MB
BOQ_752302.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .