Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L1 | Accepted-AOC AOC | |
| 2 | L2₹33.5 L+₹1.5 L (4.85%)Rejected-Finance | L2 | Rejected-Finance Highest | |
| 3 | L3₹35.8 L+₹3.9 L (12.1%)Rejected-Finance 12 53 CHOPASNI HOUSING BOARD JODHPUR 342008 | JODHPUR | RAJASTHAN | 342008 | L3 | Rejected-Finance Highest | |
| 4 | L4₹38.6 L+₹6.7 L (20.9%)Rejected-Finance V PO RAIKO KI DHANI NAWAJI KA PANA BHURTIYA DISTT BARMER RAJ PIN 344001 | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance Highest |
Tender Value
₹36.8 L
EMD Value
₹73,580
Closing Date
1 Dec 2023, 6:00 pmClosed
GE ARMY BAERMER
Military Engineer Services, Jalipa Military Station, Garrison Engineer (Army), Barmer, PIN 344001
REPAIR AND MAINT OF INTERNAL WIRING EARTHINGS LIGHTENING PROTECTION SYSTEM SUMMER APLLIANCES AND OTHER ALLIED WORKS AT POCKET B JASAI MIL STN UNDER GE ARMY BARMER
2023_MES_626676_1
8732/E8
Open Tender
Civil Works
Item Rate
240 days
GE ARMY BAERMER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY BARMER
₹73,580
12 Jan 2024
3 Nov 2023
6 Dec 2023
3 Nov 2023
1 Dec 2023
17 Nov 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring using approved colour coding as per IS (Red, Black and Green) suitable for flame proof (FLP) with 1.5 sqmm nominal cross sectional area, multi standerd flame retrdant low smoke (FRLS) insulated unsheathed copper conductor cable 1100V grade IS-694 marked TAC and FIA approved in and including surface mounted with saddles rual plug and fixing screws etc heavy duty electric resistance welded (ERW) stove enameld steel conducts ISI marked as per IS:9537 (Pt-1) 1980 of suitable size with all flame proof conduit accessories such as bends, elbows tees etc certified by CMRI dhanbad as suitable for flame proof areas and sealad with teflon tape on all conduits accessories and also sectional area multi stranderd flame retarant low smoke (FRLS) insulated, unsheathed copper conductor cable of size 1.5 sqmm 1100V grade IS-694 marked TAC and FIA approved as earth continiuty conductor connected to common earth complete all as specified and directed . for the followings: (a) One light/ Exhaust Fan point controlled by one MCB provided in main DB. Note:- Switch/MCB to be measured and paid for separately. All points shall be provided in main DB installed inside/out side the building or all as specified and directed at site.
M&L point wiring with 1.5 Sqmm (nominal area), FRLS cable 1100 Volts grade, PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including including PVC Surface Boxes of suitable module with top cover sheet fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed .
All as per srl item No 03 above but one 5 Amps 3/5 pin socket outlet on the same board with other switch.
All as per srl item No 03 above but one 5 Amps 3/5 pin socket outlet on independent board.
All as per srl item No 03 above but wiring with 2.5 sqmm copper cables with 2.5 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on independent board.
S&F in replacement switch piano, flush button, 5/6 Amps single pole, one way, 230 Volts complete all as specified and directed .
S&F in replacement socket outlet, 3/5 pin, 5 Amps, flush type complete all as specified and directed .
S&F in replacement switch socket outlet, 3/5 pin, 5 Amps, flush type complete all as specified and directed .
S&F in replacement Switch socket outlet multi-purpose 3pin, 15 Amp and 3 pin, 5 Amps controlled by one switch complete all as specified and directed .
S&F in replacement Ceiling rose complete all as specified and directed .
S&F in replacement Bell push,flush type,5 Amp complete all as specified and directed .
S&F in replacement Socket 5/6A & 15/16A - 2/3 pin combined 2 module complete all as specified and directed .
S&F in replacement modular type fan regulator 120 Watts, 2 module, complete all as specified and directed .
S&F in replacement modular type bell push switch, 1 module, complete all as specified and directed .
S&F in replacement Buzzer ,Ding Dong AC,230 volts,single pole complete all as specified and directed.
S&F in replacement stepped type electronic fan regulator flush type 220 Volts, Single Modulecomplete all as specified and directed.
S&F in replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F in replacement Switch flame proof rotary type with termination box in LM6, 16A, double pole 250V complete all as specified and directed.
S&F in replacement Switch flame proof rotary type with termination box in LM6, 25A, double pole 250V complete all as specified and directed.
S&F in replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specified and directed.
Supply and Fixing flame proof bulk head fittings with CMRI certified LED flame proof bulk head wellglass lumaniers of 40 Watts,diecast aluminium housing having safety class IP-65 with and including connections with suitable FRLS cable drawn through suitable size metalic conduits and hanging arrangements etc complete all as specified and directed. Make:- CG cat part No-FWL 1315-40-CDL (GLAZE PRO) or techno commercial equivalent model make of Wipro/Philips/Sudhir
Supply and fix in replacement LED Tube Rod ( integrated Driver),3000K or 5700K colour temp, 4 feet long of 18/20 watt in existing tube light fitting complete all as specified and directed. Make - Crompton/ Havells/ Wipro
S&F in replacement Lamp holder insulated body with black plate suitable for batten fitting complete all as specified and directed . Make - Crompton/ Havells/ Wipro/Bajaj.
S&F in replacement LED 25 Watt street light fitting with IP-66, Dust and water resistant, secondary lenses etc. for bldg security complete with light grade GI brackets, Nuts, bolts complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and length for wall mounting as specified and directed. Make - Crompton/ Havells/ Wipro
M&L Sub main wiring with 6 sqmm (Nominal area) FRLS cable 1100 Volts grade, with two runs of single core cable PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point complete including taking down old unsv submain wiring all as specified and directed. (Note :- Two runs cables and one run of earth wire incl PVC casing caping will be measured as one length.)
All as per srl item No 26 above but with 4 sqmm cables and 4 Sqmm earth continuity conductor. complete all as specified and directed .
Material and labour for sub main wiring 4.0 sqmm copper cable drawn through flame proof conduits complete with 4.0 sqmm single core multistranded copper conductor 1100V grade IS-694 marked TAC and FIA approved in and including surface mounted with saddles rual plug and fixing screws etc heavy duty electric resistance welded (ERW) stove enameld steel conducts ISI marked as per IS:9537 (Pt-1) 1980 of suitable size with all flame proof conduit accessories such as bends, elbows tees etc certified by CMRI dhanbad as suitable for flame proof areas and sealad with teflon tape on all conduits accessories PVC insulated, and unsheathed cable 1100 volts grade on sunk cast iron terminal boxes with 4.0 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly with and including necessary connection to MCB/Flame proof switch/Flame proof light fittings/Flame proof Sockets etc including taking down old unsv submain wiring with steel conduit all as specified and directed. Note:- 2 runs of 4.0 sqmm and 1 run of 4.0 sqmm cable for earth continuity and conduit shall be measured as 1 RM.
All as per srl item No 28 above but 2 runs of 2.5 sqmm and 1 run of 2.5 sqmm cable for earth continuity complete all as specified and directed
S&F in replacement Factory made board double door distribution in sheet steel enclosure with 200 Amps rated bus bar SPN, 4 way 240 Volts suitable for fixing MCBs complete all as specified and directed.
All as per srl item No. 30 above but SPN, 8 way, 240 Volts.complete all as specified and directed .
All as per srl item No. 30 above but TPN, 4 way, 415 Volts. complete all as specified and directed .
S&F MCB, SP 'C' Curve, 240 Volts, 6 to 32 Amps.complete all as specified and directed . Make : Indoasian /C&S /Legrand
S&F MCB, SPN 'C' Curve, 240 Volts, 16 Amps.complete all as specified and directed . Make : Indoasian /C&S /Legrand
S&F MCB, SPN 'C' Curve, 240 Volts, 32 Amps.complete all as specified and directed . Make : Indoasian /C&S /Legrand
S&F MCB, SPN 'C' Curve, 240 Volts, 40 Amps.complete all as specified and directed . Make : Indoasian /C&S /Legrand
S&F MCB, SPN 'C' Curve, 240 Volts, 20 Amps.complete all as specified and directed . Make : Indoasian /C&S /Legrand
S&F MCB, SPN 'C' Curve, 240 Volts, 25 Amps.complete all as specified and directed . Make : Indoasian /C&S /Legrand
S&F MCB TPN 'C' Curve 63 Amps. 415 Volts complete all as specified and directed Make : Indoasian /C&S /Legrand
Taking down ceiling fan/Wall Mounting Fan, any size and sweep from its position and transport to workshop for servicing, dismantling for servicing including removal of bearing,bushes,condenser, connector, flexible cord, split pin etc if required removing old grease and refill fresh, lubricating bushes along with new washers, cleaning and washing fan blades, fan body etc with soap solution after repairing, re-assemble the same and transporting from workshop to any location in Jasai and fixing to position/location directed, connecting to electric system, testing etc complete all as specified and directed . Note : -(i) Replacement of parts/rewinding shall be measured and paid separately (ii) Quoted rate is deemed to be inclusive of transporting fan from any location in Army Area to MES store & taking down unserviceable/ defective parts. (iii) Item such as bearings, gun metal bushes, capacitor, shaft etc required for replacement shall be measured and paid separately as supply only.
All as per srl item No 40 above but for Exhaust fan of any size and make.
Spray painting of ceiling fan, fan blades, down rod, canopy etc with a coat of Ist quality synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the fan numbers etc with black paint complete all as specified and directed.
Supply only fan blades (set of three) of any make / type of ceiling fan of size 1200mm sweep complete all as specified and directed.
Supply only fan blades (set of three) of any make / type of ceiling fan of size 1400 mm sweep complete all as specified and directed .
Supply only U clamp complete with nut bolt washer, split pin and rubber weal etc complete all as specified and directed .
M&L for Cutting and taking out old burnout winding of any sweep ceiling fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and directed .
M&L Cutting and taking out old burnout winding of 230/250 mm sweep exhaust fan / wall fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and directed .
All as per srl item No 47 above but for 300 mm sweep.
All as per srl item No 47 above but for 380/450 mm sweep.
M&L Spray painting of exhaust fan of any size and make with a coat of Ist quality synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the fan numbers etc with black paint complete all as specified and directed.
Supply only ball bearing suitable for ceiling fan / exhaust fan of any sweep complete all as specified and directed .
Supply only gun metal bush suitable for ceiling fan of any sweep complete all as specified and directed .
Supply only gun metal bush suitable for exhaust fan of any sweep complete all as specified and directed .
Supply only capacitor 2.5 MFD suitable for ceiling fan of any sweep complete all as specified and directed.
Supply only capacitor 4 MFD suitable for exhaust fan / wall mounting fan of any sweep complete all as specified and directed.
Supply only for replacement metallic bottom plate of ceiling fan of any sweep complete all as specified and directed.
S&F in replacement 250 mm sweep Exhaust fan (plastic body) minimum three star rating with accessories complete all as specified and directed .
S&F in replacement 300 mm sweep Exhaust fan metallic body minimum three star rating with accessories complete all as specified and directed .
Dismantling and taking down carefully the existing unserviceable geysers of any storage capacity, any make, any model fixed in any position by disconnecting from electric connection and water inlet, out let connection and vent pipes etc from site (inside or outside bldgs) and transporting the same to MES E/M Office Jasai Store Yard for carrying out repair work such as over hauling / brazing welding etc and painting with one coat white colour synthetic enamel paint and re-fixing in same position including making good disturbed surface after complete repair work and reconnection of inlet, outlet pipe and vent pipe including testing complete all as specified and directed. Note : - (i) Replacement of parts shall be measured and paid separately (ii) Quoted rate is deemed to be inclusive of replacement of 4 Nos foundation bolts,nuts,washers of suitable size.
S&F in replacement of thermostat switch 240 volts AC suitable for geysers of any make/model and capacity (ISI Marked) complete all as specified and directed.
S&F in replacement of heating element of 1500 watt for geysers including nuts, bolts, gasket etc complete all as specified and directed.
S&F in replacement of bottom cover of 25 ltrs capacity geyser of any make / model duly painted to match with the existing surface complete all as specified and directed.
S&F in replacement of copper tank of 25 ltrs capacity geyser ISI marked manufactured out of cold rolled pressure electro type copper sheet of appropriate thickness double tapped brazing / welded internally copper tinned and hydraulically tested including nuts, bolts, washers, etc complete all as specified and directed.
S&F in replacement of brass chromium plated flexible connection pipe (length not less than 30 cm and not exceeding 50cm) with coupling nuts with washers suitable for 15 mm bore pipe complete all as specified and directed.
S&F in replacement of PVC (heavy duty) flexible pipe connection of 15 mm bore 450 mm long with two Nos brass coupling suitable for cold water complete all as specified and directed.
S&F in replacement of cable connection of geyser by PVC round insulated / sheathed copper cable of size 03 core 40/0076 and making necessary condition.
S&F in replacement 3 pin plug top of capacity 15 Amp AC 240 Volts 50 Hz.complete all as specified and directed .
S&F in replacement sheet metal enclosures comprising two pin and earth plug socket, MCB SP 20 Amps (C-curve-10 KA) complete all as specified and directed.
S&F in replacement of 15mm bore brass non return valve (ISI Marked) vertical / Horizontal type and fixed to GI pipe fittings complete all as specified and directed.
S&F in replacement of GI tubing 15mm bore medium grade (ISI Marked) with all GI fitting and fixed complete to walls and ceiling or laid in floor for inlet and outlet water connection to existing O/H tank complete all as specified and directed.
S&F in replacement of GI tubing 20mm bore medium grade (ISI Marked) with all GI fitting and fixed complete to walls and ceiling or laid in floor for inlet and outlet water connection to existing O/H tank complete all as specified and directed.
S&F in replacement of Gun metal gate valve with iron wheel head, screwed both ends for iron pipe of size 15mm bore complete all as specified and directed.
Supplying and fixing in repair 1100 Volts grade heavy duty cable PVC insulated aluminium conductor cable solid stranded, served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core cable flat or circular in section of cross sectional area 6 Sqmm 2 core complete all as specified and directed.
All as per srl item No. 73 above but size of 10 Sqmm 2 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation, laying of cable etc.n exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated soil to a distance 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed .
Supply and filling dry clean sand (tibba sand) in trenches for cushioning of underground cable and punning for cushioning to cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
M&L 40 to 50mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and not less than 60 cm in length, laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cable protection complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core including taking out old unserviceable cable complete all as specified and directed.
All as per srl item No 80 above but sec. area 25 sq. mm 4 core.
All as per srl item No 80 above but sec. area 50 sq. mm 3.5 core.
All as per srl item No 80 above but sec. area 70 sq. mm 3.5 core.
Taking down existing unsv earthing and M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all directed by Engineer-in-charge. NOTE :(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-( ii) Item includes the cost of GI pipe up to 7.5m for protection of earth wire.(iii) Item includes cost of lead wire up to 7.5 m.
Taking Down/Dismantling of U/S Air Termination any type complete all as specified and directed.
Supply and fixing Air termination single pointed copper rod 12 mm dia and 300 mm long .
Supply and fixing Air termination single pointed aluminium rod 12 mm dia and 300 mm long.
Taking Down/Dismantling of U/S Test point terminal block complete all as specified and directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw complete all as specified and directed.
Taking down/Removing of unserviceable strip any type complete all as specified and directed.
Supply and fixing Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed .
Supply and fixing Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Taking up/Dismantling of U/S Earthings any type complete all as specified and directed.
M&L for Earthing complete using copper plate 60×60cm ×3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to 20x3 mm copper strip thick by means of bolt nuts check nuts and washers of copper all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal, salt, funnel complete all as specified and directed.
M&L for Earth continuity conductor fixed to wall or recess or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and directed .
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm ×60 cm × 6mm thick and 32x6 mm GI strip as earthing lead buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal, salt, funnel, complete all as specified and directed.
M & L for bore well earthing by drilling bore with bore machine for lightening protection system using GI pipe heavy duty 50 mm dia as earth electrode driven up to a depth of 50 meters below ground level, duly made holes at 20 cm intervals, along the length of GI pipe and providing the charcoal salt mixture incl GI pipe 150 mm dia light grade as protection upto a depth of 12 meters and GI strip of 32x6 mm so as to acheive desired earth results. Testing and commissioning complete all as specified and directed. (Earth strip of size 32x6mm upto a length of 7.5m is deemed to incl in this item rate).
M&L for Earth continuity conductor fixed to wall or recess or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed .
Taking up/ Dismantling of U/S Earth Continuity conductor any type complete all as specified and directed.
Material and labour for disconnection and testing of desert cooler from existing locations for fault finding & connecting back after reparing/ servicing. Note :- Spare parts required for replacement during reparing/ servicing shall be measured and paid separately as "Supply & Fix"
Material and labour for transportation & deposition of desert cooler any type to MES Yard on the directions of Engineer in charge as per the technical and as well as site requirement (where there is no feasibilty to get the repairs done at site/ existing location) for testing /Fault finding and transporting back to site from MES Yard after repairing/servicing if necessary & as directed by Engineer-in-Charge. Note :- T&P/ vehicle required to carryout the repair work shall be arranged by contractor at their own cost & the cost deemed to be inclusive in the quoted rate.
Material and labour for rewinding desert Cooler fan motor 3 speed,1400 RPM of capacity 1/5 HP with super enameled copper wire of appropriate size including replacement of bush, shaft and capacitor 4 MFD,240 volts complete all as specified and directed. Note : Cost of provision of new brush, shaft and capacitors in replacement is deemed to be inclusive in the quoted rate of this item.
Material and labour for replacement of capacitor for fan motor of 4 MFD, 230/250 V suitable for desert cooler fan motor complete all as specified and directed
Material and labour for any size patch repair work to Unserviceable corroded portion of body of Desert Cooler with 18 to 24 gauge (as per existing sheet) PGI sheet including necessary welding and painting with two coat of synthetic enamel spray paint over one coat of red oxide primer (the new surfaces should specified & match with existing surface) including leakage testing complete all as specified and directed.
Material and labour for dis-connection,taking down ,transportation & deposition of air curtain any type and size to MES Yard incluiding testing /Fault finding at MES Yard and transporting, installing and connecting back to site from MES Yard after repairing/servicing, rewinding of air curtain fan motor with super enameled copper wire of appropriate size including replacement of bush, shaft and capacitor of suitable size, 240 volts complete all as specified and directed. Note :- T&P/ vehicle required to carryout the repair work shall be arranged by contractor at their own cost & the cost deemed to be inclusive in the quoted rate.
Material and Labour for replacement of bottom water tank of desert cooler of any size fabricated out of 18 gauge PGI sheet incl nuts bolts and washers etc complete all as specified & directed.
Material and labour for replacement of side supporting columns to be fabricated out of 18 gauge PGI sheet of any size incl necessary nut, bolts etc complete all as specified & directed.
Material and Labour for replacement of side cover with louvers of desert cooler of any size fabricated with thickness out of 0.8 mm PGI sheet incl nuts bolts and washers etc complete all as specified & directed.
Material and Labour for replacement of top head of desert cooler of any size fabricated with thickness out of 18 gauge PGI sheet incl nuts bolts and washers etc complete all as specified and directed
Material and labour for preparation of old painted steel surfaces of Desert cooler up to 5000 cfm and applying a coat of synthetic enamel spray paint & two coats of anti corrosive black paint inside the Body water tank & side grills etc and writing of MES/SM NO using synthetic enamel paint etc complete all as specified and directed.
S&F in replacement Desert Cooler fan motor capacity 1/7 HP three speed comprising of copper wound coils with 1400 RPM single phase with mounting ring and other connected items complete all as specified and directed. Make: Crompton/Havells/Khaitan/Bajaj.
S&F in replacement submersible pump 18 watt of discharge 6 LPM at head 2.5 Mtr 220-240 Volts AC supply, single phase, etc complete all as specified and directed. Make: Crompton/Havells/Khaitan/Bajaj.
S&F in replacement Wood / wool chips pad for Desert Cooler of suitable size (set of three pads) superior quality complete all as specified and directed.
S&F in replacement supporting jali of wood/wool chips pad set (set of three) made out of hard MS wire and fitted in side louvers complete all as specified and directed.
S&F in replacement PVC water distributor of 3 outlets with MS nuts & bolts complete all as specified and directed.
S&F in replacement PVC elbow suitable spliter for desert cooler complete all as specified and directed.
Material and labour for replacement of desert cooler fan blade assembly comprising of four blades of sweep 400mm made out of heavy duty PVC with bracings screw for desert cooler heavy duty etc, complete all as specified directed.
S&F in replacement PVC pipe 15 mm dia heavy duty for Desert Cooler Pump complete all as specified and directed.
S&F in replacement 3 pin plug top of capacity 5 Amp AC 240 Volts 50 Hz complete all as specified and directed.
S&F in replacement motor fixing ring, clamps, four brackets with rubber pad and eight screw (clip type) for desert cooler complete all as specified and directed.
Akarsha Enterprises
PANKAJ ENTERPRISES
M/s Malinath Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .