Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | L1 | Accepted-AOC Technocommercially eligible L1 bidder | |
| 2 | Rejected-Technical | - | Rejected-Technical Rejected for not being L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected for not being L1 | |
| 4 | Rejected-Technical NOT SPECIFIED | - | Rejected-Technical Rejected for not being L1 | |
| 5 | Rejected-Technical AT REMUAN PO HATATOTA TALCHER DIST ANGUL PIN 759100 | ANUGUL | ODISHA | 759100 | - | Rejected-Technical Rejected for not being L1 |
Tender Value
₹8.6 L
EMD Value
₹10,800
Closing Date
6 Aug 2024, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Electrical wiring by PVC conduit for 06 nos of weighbridges near coal stock 1, 8 and LnT Chhak and a coal sampling room at railway siding 1 and 2 under Bhubaneswari OCP
2024_MCL_313322_1
GM(JA)/EnM/e-Tender /24-25/E-675/40 DTD. 24/07/24
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
TALCHER
AS PER NIT
4 documents required · 4 mandatory
₹10,800
7 Sept 2024
24 Jul 2024
8 Aug 2024
25 Jul 2024
6 Aug 2024
25 Jul 2024
25 Jul 2024 - 30 Jul 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.(2 X 2.5 sq. mm + 1 X 2.5 sq. mm )
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.(2 X 4 sq. mm + 1 X 4 sq. mm )
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.(1 X 1.5 sq. mm )
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.(4 x 6 sqmm+2 x 6 sqmm earth wire )
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or recesses with suitable size with phenolic laminated sheet cover in front including providing and fixing 5 pin 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 250 mm X 75 mm deep .
Supplying & fixing angle holder including connection etc as required.
Supplying & fixing 3 pin, 5 Amps ceiling rose on the existing junction box/wooden block including connection etc. as required.
Supplying and fixing 5 Amps piano type switch on the existing switch board including connections etc. as required.
Supplying and fixing of 5/6 Amps piano type socket on the existing switch board including connections etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 poles and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 63 Amp
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingas required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63A TP&N
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
Supply of Ceiling Fan 1200 mm
Supply of Wall Fan 400 mm
Supply of exhaust fan 450 mm
Providing & Fixing of led tube light fittings (18 Watt)
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Providing and Erection of Metal Oxide lighting arrester
Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with surge protection device 240 Volts 1 ph-N complete with connections, testing and commissioning etc. as required
Total impact of GST for the purpose of CTC
M/S MAA ELECTRICALS
M/S SIDDHI ELECTRICALS
S.N. ENTERPRISES
R K ENGINEERING
TARENI ELECTRICALS
CHITTARAJAN MAITY
M/S. S.K.ENGINEERING
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .