Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.7 L+₹4.0 L (9.17%)Rejected-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L2 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
14 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, St.Thomas Mount,
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
SPL REPAIRS TO BLDG NO.T-935, T-936 T-938, PROVN OF GUARD ROOM WITH LIVING ACCN, PROVN OF ANTI STATIC FLLORING AND AC FOR SINGLR DET FOR SINGLE DET,PROVN OF TEA/SNACKS COUNTER FOR CADETS IN WT AREA AND PROVN OF 2023-24 AROUND FOUNTAIN WELL IN OLD S
2023_MES_593652_1
8342-SPL REPAIRS TO BLDG NO.T-935,936 and T-938
Open Tender
Civil Works
Item Rate
GE STM
As per tender documents
6 documents required · 6 mandatory
₹500
Garrison Engineer, St.Thomas Mount
₹98,000
Yes
4 Jul 2023
6 May 2023
22 Jun 2023
6 May 2023
14 Jun 2023
26 May 2023
6 May 2023 - 15 May 2023
Amount
Dismantling Asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles.
Demolition of unreinforced concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and disposed off from site all as directed.
Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for (reinforcement of cut as required to facilitate demolition).
Taking down cement plaster on brick walls, ceilings etc including raking out joints, hacking for key, scrubbing down with water, etc.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out hard/dense soil.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation for drain n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard dense soil
Excavating post holes (or similar holes) each n.exc 0.5 cum, getting out hard/ dense soil including cutting of PCC floor & removing surplus soil and debris to a distance n.exc 50m and making good surface.
M&L for providing PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in mass concrete and foundation filling
M&L for providing RCC (nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate as in column footings and plinth beams etc
M&L for providing RCC (nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate as in columns, pillar pier post etc
M&L for providing RCC (nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate as in roof beams and lintel bands etc
M&L for providing RCC (nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab
M&L for RCC (Nominal Mix) 1:2:4 Type B-1 using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed
M&L for form work to sides of concrete foundations , footings bases of columns, sides and soffits of foundation and plinth beams and similar work rough finished surfaces of concrete flat
M&L for form work to soffits of suspended slabs such as roof slabs and similar work not exceeding 200mm thick in flat rough finished surfaces of concrete
M&L for form work to sides of pillars, posts, struts, piers, columns and stanchions rough finished surface of concrete rectangular
M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming
All as per item No.20 but 5mm dia and over upto and including 10 mm dia in stirrups spaces and binders
M&L for Brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 all as specified
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4, finished even and smooth without using any extra cement.
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement
M&L Rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling, finished even and smooth without using extra cement.
M&L for 15mm thick rendering in two layers of 10mm thick and 5mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even & smooth w/o using extra cement, using water proofing compound in top layer complete all as specified and as directed. Note: LWPC shall be measured and paid separately
Complete removal of existing treatment on walls and applying two coats of cement base paint over a coat of alkali resistant priming paint on external surfaces of walls..
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant priming paint on external surfaces of walls.
Complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer with 3mm thick wall putty all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of primer with 3mm thick wall putty on internal surfaces of walls.
Preparing surfaces plastered or unplastered on new surfaces on ceiling and applying three coats of white wash
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate, as in plinth protection 75mm thick finished even and fair including necessary form work all as specified
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering
Hardcore of gauge n.exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stone or boulders
M&L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base to floor
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base to floor
M&L for cement concrete 1:4:8 type D-2 concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, bore of pipe in 110mm complete all as specified and as directed.
M&L for PCC 1:2:4, type B-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete.
M&L for PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) as in block for hold fast, filling in frames, coping or similar work and finished the surface with existing and including form work.
M&L for 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick joint free coloured tiles area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over Screed bed or bedding layer of mortar 15 mm thick in Cement mortar 1:4 for laying floor finishes.
M&L for non skid ceramic coloured joint free tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces over 15 mm thick screed bed in CM 1:4 complete all as directed.
All as per item No.44 above, but in vertical surfaces as in skirtings, incl backing coat of 10 mm thick in CM 1:3 all as specified and directed.
M&L Glazed ceramic coloured joint free tiles in vertical surface 350x 250x 7 mm/ 450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement including backing coat of 10mm thick in CM 1:3 all as specified.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20 mm thick screed bed in CM (1:4) all as directed
M&L for machine cut kota stone slab 20-25mm thick in skirting, risers of steps, dado laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 15 mm thick backing coat in CM (1:4) complete.
S&F Anodised aluminium snap grid frame work ( Size of grid 605 x 605 mm) for false ceiling all as specified
M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions.
Supply only liquid water proofing chemical
S&F Solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and directed including making good to the surfaces.
S&F Factory made PVC moulded door shutters 30mm thick made out of MS tubes of 19 gauge thickness and size 19mmx19mm for stiles and 15mmx15mm for top and bottom rails MS frame shall have a coat of steel primers. The inner panel shall consist of 25mm thick termite proof water proof and fire resistant moulded PVC rigid foam sheet in different plain, The panel to be sealed with lipping of 10mm wide PVC sheet batten(Made by stacking 5 PVC rigid foam sheet of 5mm thickness and 25mm width) on the side opposite to where hinges are fitted etc complete as per manufacturers drg and specified.
Taking down chowkats or frames with shutters (without taking off shutters from frames) n exc. 1.5 Sqm including making good disturbed surfaces.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exc. 1.5 Sqm but n. exc 4 Sqm each including making good disturbed surfaces all as specified.
M&L for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints supplied and fixed complete all as specified
S&F pressed steel frames (size 105X60mm) for doors with one rebate including necessary fixing lugs, hinges, lock strike plate etc complete all as specified
M&L for 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides
M&L for Second class hardwood 35mm thick glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze etc., with sash bars, divided into squares edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) and supplied and fitted to chowkats.
M&L for Second class hardwood 35 mm thick plain, framed, panelled shutters (any number of panels), with lock rail and panels of 9mm B.W.P commercial Ply or 12mm veneered particle board medium density, wood particle board with commercial both face veneers; supplied and fitted to chowkats. Note: The size of rail and style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated
M&L for Second class hardwood 30mm thick glazed and skeleton window/vent shutters, open rebated and prepared to receive glass, gauze etc., with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b) and supplied and fitted to chowkats.
S&F Sheet glass 4mm thick ordinary quality and glazing with 12mm square beading in squares n.exc 0.5 Sq.m in each pane.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
M&L for Preparation of new wood or wood based materials of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on ceiling/ wooden door and window surfaces
M&L for preparation of new steel surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Material and labour for preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
S & F hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
S&F framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters and similar work conforming to Fe 290 Gde E-165
S&F for Mild steel Butt hinges, medium weight 100mm size fixed with stainless steel screw all specified and directed.
S&F for Mild steel Butt hinges, medium weight 75mm size fixed with stainless steel screw all specified and directed.
Supply and Fix Aluminium anodised barrel tower bolts of extruded section 200 mm size all as specified.
S & F aluminium anodised, barrel tower bolts of extruded section and fixed 150 mm long.
S&F Aluminium anodised barrel tower bolts of extruded section 125 mm size.
S & F extruded aluminium alloy handles, fabricated type, anodised 150 mm long complete all as specified and directed.
S&F Extruded aluminium alloy handles, fabricated type, anodised 125 mm long.
S&F Aluminium alloy, anodized, 300mm sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded section & fixing blots & sliding bolts of extruded section or cast aluminium alloy & fixed with screws etc., complete all as specified
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in trenches or in floors, 75mm bore.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in trenches or in floors/walls, 110 mm bore.
S&F PVC (SWR) bend 75 mm bore.
S&F PVC (SWR) bend 110 mm bore.
S&F PVC (SWR) floor trap plain 75mm dia outlet with grating including jointing with solvent cement complete all as specified and as directed.
S&F PVC (SWR) multi floor trap with grating including jointing to solvent cement waste pipe 75 mm dia.
S&F PVC (SWR) vent cowl 110 mm
S&F Brass chromium plated 32 mm bottle traps for urinals with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed
M &L GI tubing 15mm dia medium grade galvanised with all fitting complete fixed to walls and ceiling or laid in floors
M&L GI tubing 20 mm dia medium grade galvanised with all fitting complete fixed to walls and ceiling or laid in floors
S&F in repairs 15mm bore steel tubes medium grade galvanised with all fittings / fixtures concealed to walls and ceilings or laid in floors.
S&F in repairs 20mm bore steel tubes medium grade galvanised with all fittings / fixtures concealed to walls and ceilings or laid in floors.
S&F Bib taps 15 mm bore chromium plated crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule
S&F in repairs bib cock long body with flange, fancy type chromium plated, screwed down, screwed for iron pipe, 15 mm bore or for brass ferrule and fixed all as specified
S&F Pillar taps 15 mm bore cast copper with capstan heads chromium plated screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed
S&F in repairs Pillar taps CP cast copper alloy fancy type with capstan heads, chromium plated, screwed down, high pressure with or without lettered Hot or cold with long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore.
S&F Angle cock Fancy type 15 mm bore chromium plated with long shank and cup (Concealed type) high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions
S&F in repairs Angle valves, cast copper alloy, screwed down, high pressure and fly nuts, screwed for iron pipe 15 mm bore all as specified.
S&F vitreous china wash down water closet (pedestal pattern) , white, of style and pattern as existing, complete with and including plastic seat cover, white fixed all as directed.
S&F in repair Vitreous China wash down water closet (pedestal pattern), white (excluding flushing cistern and flush pipe) incl Pedestal pan and trap, connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, seat cover etc, complete all as directed
S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, low level flushing cistern (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, if any and fixing complete
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, low level flushing cistern (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, if any and fixing complete
S&F vitreous China wash basin, white, flat back, size 550x400mm incl 32mm waste fittings, brass, chromium plated for glazed ware basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S&F in repairs vitreous China wash basin, white, flat back, size 550x400mm incl 32mm waste fittings, brass, chromium plated for glazed ware basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S&F in repairs CP Health faucet with CP connection and hook fixed with screws etc., all as specified and directed.
Supply and fix Tubular aluminium anodised towel rail, 20mm dia, D type, 60cm long between flange
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement;
PVC connections 15mm size with PTMT nuts of length 450mm
S&F low density 32mm dia bore polythene waste pipe (LDPE) of pressure rating 0.6 Kgf/Cm2.
Dismantling PVC water tanks, 1000 litres capacity & removing to store
S&F rotational moulded polyethylene water storage tanks of capacity 1000 litres (cylindrical, 3 layered, vertical with closed top) hoisted and fixed in position all as specified.
S&F rotational moulded 3 layered polyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 3 no's of 20mm size nipple (minimum weight 20mm-45gms) suitable for HDPE water tank complete all as specified.
S&F 25 mm dia Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule.
S&F 20mm bore ball brass valves high pressure, with polythene float & fly nut complete screwed for iron pipe or brass furrel and fixed.
S&F in repairs 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe.
M&L Salt-glazed stoneware drain pipes 150 mm dia laid in trenches and jointed as specified
Material and labour for PCC 1:3:6, type C2 (using 40mm grade stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 150mm bore all as specified
M&L for providing precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in manhole cover/shelves for WHBs and set in CM 1:6 and set in cement mortar 1:6
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm internal bore pipe
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in hard/dense soil
M&L for cement screed bed 20mm thick in CM 1:4 with using liquid water proofing chemicals
M&L for APP Modified prefabricated five layer water proofing membrane, not less than 3 mm thick and weighing not less than 3.80 kg/sqm reinforced with non woven polyester matt black finished over compatible primer @ 0.3 Ltrs per sqm, torching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per manufactures instructions and finally finished with a coat of bit mastic aluminium paint over a coat of blown bitumen 85/25 grade @ 1.20Kg/Sqm over the membrane. The Overlap joint shall be provided of 75mm in longitudinal direction and 100mm in transverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage. Manufacturers: STP/ IWL India Ltd / SAPL (ARGO-P) / Hydrotech Limited (Hydroflame) / TIKIDAN Note: The work shall be carried out by authorized applicators of manufacturers
M&L for chequered cement concrete tiles 30cmx30cmx 25mm thick set, jointed and pointed neat cement slurry in floor with grey cement and pigments, incl 20 mm thick screed bed CM 1: 4 all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate louvers and jallies, 45 mm thick (measured solid) incl. all moulds set in CM 1:4 including demolition
M&L for mild steel roof trusses (framed), trussed purlins, crane, gantries, rails and fastening and heavy bracket framing (beam, tee, angle, channel or flat sections) incl distance pieces, cleats etc. conforming to Fe 410-0 (Gde E-250) quality 'A' all as specified and directed
S&F mild steel work in tubular trusses, purlins, post, distance pieces including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 grade St-240.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and directed.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for mild steel flat iron for wind tie including necessary drilling holes and fixing with necessary self drilling and self tapping screws/bolts and nuts, neoprene and limpet washers complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) slab (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including edge moulding and cement screed bed 15mm thick in CM 1:4 all as directed.
M&L for Italian glass mosaic tiles of 7 to 8mm thick area of each tile exceeding 0.06Sqm but not exc. 0.11 Sqm (size of tile 300X300 mm) in dado/skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for 2mm thick PVC tiles/sheets laminated plain coloured marbled mosaic or mottled finish laid with approved rubber based adhesive in floors including necessary copper conductors etc., complete all as specified and as directed. Note:- The work shall be done through authorised applicators only.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry @ 3 Kg / Sqm complete all as specified and as directed.
Taking down carefully copper/ Aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, making good the disturbed surfaces and taken as credit all as directed.
Material and Labour for Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor drawn through and including non-metallic rigid PVC conduit PVC conduit fittings and conduit accessories concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket / electronics fan regulator / telephone socket, including provision of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for one light/fan point controlled by one way switch complete including cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10 Cm girth all as specified and as directed.
(a) One light point controlled by one switch.
(b) One Ceiling fan point controlled by one switch and one regulator.
(c) One Exhaust Fan point controlled by one Switch
(d) One 3 pin 5 amps switch socket on independent board.
(e) One 3 pin 5 amps switch socket on same board along with other switches.
All as per item No.133 above but with 4 sqmm copper conductor cable with 4 sqmm PVC copper conductor cable as earth continuity conductor for one socket outlet 15/16 amps controlled by one switch 15/16 Amps on independent board all as specified and as directed.
M&L for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 4 sqmm including one run of 4 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unsv all as specified and directed. Note:- 2 runs of cable, 1 run of earth continuity and PVC conduit shall be measured and paid as one unit.
Supply and fix in replacement of Wall mounted LED Batten with tube extruded Aluminium heat sink provided for efficient heat dissipation & integrated electronic driver of Lamp type: 22W LED life time of 30000* hours including lamp all as specified and as directed. Make: HAVELLS catalogue No ENDURALINEAR NEO BS 22WLED865SPCWH/ PHILIPS cat No B1021LED25S6500PSUGRST/ CROMPTON cat no Radiance ray plus 22W LDRR24-CDL/ HLB-03-22-CW-AL of Halonix/ Bajaj BCLAB 22W LED P
Supply and fix in replacement of Wall mounted LED Batten, Aluminium Housing & integrated electronic driver of Lamp type: 10W LED life time of 30000* hours including lamp all as specified and as directed. Make: as per HAVELLS catalogue no ENDURALINEAR NEO BS 10WLED865SPCWH/PHILIPSB1021LED10 S 6500PSUGRST/CROMPTONRETRO LED T5 LT5RT-9-CDL/ Bajaj BCLSB 10WH/ HLB-03-10-CW-AL of Halonix
S & F in replacement of Bldg Sec lights 30 W IP 66 road way luminaries with high powers LEDs as light source and electronic driver with mounting GI Pipe 40 mm dia900 mm long fixed on wall complete all as specified and directed. Make Havells cat No- ENDURAPEARLSL30WLED757SASYTOPCMP/ HALONIX cat no HLSLD-09-30CWL-R/ CROPTON cat no. LSTS-30-CDL/NL-M/ Wipro cat No.LR02-331-XXX-57-XX 30Watt.
Supply and fix MCCB Distribution board, TP&N , vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link,415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 3 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory including taking down Old DBs all as specified and directed.
Supply and fix MCCB four pole , 415 Volt, 63 Amps,16 KA , adjustable thermal & fixed magnetic setting including taking down Old MCCB complete all as specified and directed.
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link,12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
Supply & Fix MCB SP 230 volts,40 amps 'C' Curve 10 kA Capacity including taking down Old MCB complete all as directed.
Supply & Fix MCB SPN 230 volts, 40 amps 'C' Curve 10 kA Capacity including taking down Old MCB complete all as directed.
S & F Ceiling rose surface bakelite 65mm x 50 mm two to three terminals all as directed.
S & F Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed
S & F Modular switch 1 way 16A, 1 module, 240 Volts complete all as specified and directed
S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed
S & F Modular socket 6 A/ 16 A - 2/3 pin combined 2 module complete all as specified and directed
S & F Modular Fan step regulator, 100W - 1 module for ceiling Fan of 1200 mm sweep all as specified and as directed.
Supply and replacement of metal clad socket single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 230 Volts 20/32 Amps all as specified and as directed.
Taking down Old unserviceable fan ,Supply & Fix of 1200 mm sweep ceiling fan BLDC rating, energy saving model with double ball bearing 230 volts 3 blades white in colour without regulator COMPLETE WITH CANOPY, suitable DOWN ROD all as directed. Note: Old Unserviceable Fan to deposited to MES Store
Supply and fixing, ventilating (HEAVY DUTY EXHAUST FAN) fans of 300 mm sweep,1400 RPM Metallic Body ,Double Ball bearing single phase including necessary addn/altn for fixing of fans including making holes wall/windows all as per site requirement and making good the disturbed surfaces , matching with the existing wall all as specified and directed. Note: Old Unserviceable Fan to deposited to MES Store
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (surplus soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Supplying and laying burnt brick "B" class standard size for protection of cable as directed.
Supply, lay, spread in trenches river sand including spreading, levelling, punning for cushioning of cable all as directed.
Supply & Lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes all as specified and as directed. Note :- i) Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used properly wherever required while connecting cables to the panel board. ii) Earth work such excavation, refilling, etc. shall be measured separately under relevant items.
(a) 2 core 16 sqmm
(b ) 4 core 25 Sqmm
M&L for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 6 sqmm including one run of 6 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ceiling etc., and connecting to common earth dolly all as specified and directed.
S&F tubes light grade of size 40 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron/steel earth strip 25x4 by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No.3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoal dust, PCC 1:2:4 type B-1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.
Supply and install hi wall split Air conditioning 1.5 TR units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity complete all as specified and directed..
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input between 170V to 250 V with output voltage stabilized at 230 V with accuracy + 2.5% and capacity 5.0 KVA
DJ Group
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .