The Director, ICAR-IIHR, Hesaraghatta, Bangalore.
ICAR-INDIAN INSTITUTE OF HORTICULTURAL RESEARCH HESSARAGHATTA LAKE POST, BANGALORE-560 089
Construction of Laboratory Building with water supply system and electrical installation at CHES, Bhubaneswar
2022_DARE_694110_1
5-51/2022-23/SP/Cons of lab building
Open Tender
Civil Works
Works
60 days
CHES Bhubaneswar Odissa
Please refer Tender documents
3 documents required · 3 mandatory
₹0
₹44,000
Yes
25 Jul 2022
10 Jun 2022
2 Jul 2022
10 Jun 2022
30 Jun 2022
10 Jun 2022
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all kind of soil. (item code : 2.8.1)
Col : 10nos x 1.20m x 1.20m x 1.80m
Wall : 2 x 12.90m x 1.00m x 1.00m
2 x 5.40m x 1.00m x 1.00m
2 x 6.00m x 1.00m x 1.00m
1 x 1.20m x 1.20m x 1.50m
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (item code:2.27)
Col: 13nos x 1.20m x 1.20m x 0.30m
Wall : 2 x 12.90m x 1.00m x 0.15m
2 x 5.70m x 1.00m x 0.15m
2 x 6.00m x 1.00m x 0.15m
Under floor : 12.30m x 5.40mx 0.8m
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (item code:4.1.8)
13nos x 1.20m x 1.20m x 0.15m
2 x 12.90m x 1.00m x 0.08m
2 x 5.70m x 1.00m x 0.08
2 x 6.00m x 0.08m x 0.08
12.30m x 5.40m x 0.10m
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) (item code:4.1.3)
12.3m x 5.40m x 0.08m
5.00m x 2.00m x 0.08m
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).(Item code: 5.1.3)
13nos x 1.20m x 1.20m x 0.10m
10nos x 0.50m x 0.50m x 0.30m
3 x 0.30m x 0.20m x 0.20m
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).(Item code:5.2.2)
3 x 0.25m x 0.25m x 5.70m
10nos x 0.40m x 0.25m x 5.70m
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).(Item code:5.3)
P.Bend: 2 x 12.90m x 0.25m x 0.25m
4 x 5.70m x 0.25m x 0.25m
Lintel beam : 2 x 12.9m x 0.25m x 0.15m
2 x 5.70m x 0.25m x 0.15m
Roof beam : 2 x 12.20m x 0.25m x 0.20m
4 x 5.70m x 0.25m x 0.20m
Chajja : 8 x 2.00m x 0.60m x 0.10m
3.00m x 2.00m x 0.10m
Roof : 12.90m x 6.00m x 0.10m
Working platform : 18.00m x 0.60m x 0.10m
2 x 6.00m x 0.25m x 0.15m
6.00m x 0.25m x 0.20m
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.(Item code:5.9.1)
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform (item code:5.9.3)
Centering and shuttering including strutting, propping etc. and removal of form for :Shelves (Cast in situ) (item code:5.9.4)
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers (item code:5.9.5)
PL : 2 x 12.90m x 0.50m
LB : 2 x 12.90m x 0.30m
RB : 2 x 12.90m x 0.40m
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Hot rolled deformed bars.(Item code:5.22.4)
0.90 x 2.67 = 2.403 1.20 x 6.77 = 8.124 1.00 x 18.08 = 18.08 28.607 qtl
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) (item code:6.1.2)
2 x 12.90m x 0.40m x 0.30m
2 x 12.90m x 0.25m x 1.00m
2 x 6.00m x 0.40m x 0.30m
2 x 6.00m x 025m x 1.00
2 x 6.00m x 1.00m x 0.25m
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:6 (1 cement : 6 coarse sand) (item code:6.32.2)
2 x 12.30m x 3.20m x 0.25m
2 x 5.4m x 3.20m x 0.25m
(-) Deduction for 'D' & 'W'
D : 1 x 1.80m x 2.10m x 0.25m (-)0.945
W : 8 x 2.00m x 1.20m x 0.25m (-)4.80
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement :3 coarse sand) (item code :6.13.1)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (item code:6.15)
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (item code:9.20.2)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (item code:10.2)
Door : 1 x 6.00m = 6.00m 2 x 5.70m = 11.40m 1 x 5.40m= 5.40m 22.80m @ 4.5 kg/m
Window : 7 x 6.40m = 44.80 m 44.80 @ 3 kg/m
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding (item code:9.48.1)
7 x 2.00m x 1.20m = 16.80m2 16.80 m2 @24.80 kg/m2
12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) (item code:13.1.1.)
Chajja : 8 x 1.80m x 1.50m
20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand).(Item code:13.3.1)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (item code: 13.26)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (item code:13.47.1)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (item code:13.48.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (item code:13.62.1)
2 x 8 x 1.80m x 1.50m
2 .04m x 1.50m x 2.10m
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron (item code:21.1.1.3)
7 x 2.00m x 1.20m = 16.80m2 16.80 m2 @ 5.7 kg/m2
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (item code:21.1.2.3)
7 x 2.00m x 1.20m = 16.80m2 16.80 m2 @ 5.7 kg/m2
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) (item code:21.3.2)
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) (item code:22.14.1)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (item code:11.41.2)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (Item code:11.56.1)
SANITARY INSTALLATION
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes (item code:18.9.1)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes (item code:18.9.3)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.50 mm nominal outer dia Pipes (item code:18.9.6)
Providing and fixing brass made gate valve with CI wheel of approved quality ISI marked . 25mm nominal bore.
Providing and fixing brass made gate valve with CI wheel of approved quality ISI marked . 50mm nominal bore.
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm (item code:17.11.2)
Providing and fixing long body brass made with ss coat bib cock of approved brand (Jaguar/Kohler etc.)
Providing and fixing 2000 litre capacity PVC tank of approved brand (Syntax or equivalent) on cemented platform with required delivery/suction system wiring etc. all complete.
ELECTRICAL INSTALLATION
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size (50 sq.mm) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying of 50 sq.mmPVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade as required.
Supplying and fixing of following ways (4 + 12) surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 5 pin 15/16 A modular socket outlet and 2 nos. 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 nos. 5 pin 5/6 A modular socket outlet and 3 nos. 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 1 no. 5 pin 15/16 A modular socket outlet and 1 no.25A modular AC starter, connections etc. as required.
Supplying,installation,testing,Commissioning of inverter based split AC fitted with rotary compressor with nominal cooling capacity ( 5star rating) unit(1.5TR) both outdoor compessor unit and indoor cooling unit inside roomns with necessary accessories such as brass flare nut,screw PVC and other taps and making all arrangements for lifting the units up to the terrace, making hole, cutting the wall etcs. complete as required.( Make-Hitachi, Carrier ,Voltas)
Supplying,installation,testing,Commissioning of inverter based split AC fitted with rotary compressor with nominal cooling capacity ( 5star rating) unit(2TR) both outdoor compessor unit and indoor cooling unit inside roomns with necessary accessories such as brass flare nut,screw PVC and other taps and making all arrangements for lifting the units up to the terrace, making hole, cutting the wall etcs. complete as required.( Make-Hitachi, Carrier ,Voltas)
Supplying and installation, testing and commissioning of following voltage stabilizer(4KVA) having range 130-300 volt with high voltage/ low voltage over load auto tripping arrangement and 3 minutes delay starting and connection with 3 core flexible heavy duty copper conducter cable of required length etc. complete as required.(Make-V-guard,EL power,opto).
Supplying and installation, testing and commissioning of following voltage stabilizer(5KVA) having range 130-300 volt with high voltage/ low voltage over load auto tripping arrangement and 3 minutes delay starting and connection with 3 core flexible heavy duty copper conducter cable of required length etc. complete as required.(Make-V-guard,EL power,opto).
Supplying and fixing of 63A 4pole MCB as required.
Supplying and fixing of 32A C type SP MCB as required.
Supplying and fixing of 25A C type SP MCB as required.
Supplying and fixing of 16A C type SP MCB as required.
Supplying and fixing of 20W LED batten light as required.
Supplying and fixing of 18W LED surface panel light(Sqare type) as required.
Supplying and fixing of 78W high speed ceiling fan(48'') with good star rating as required.
Supplying and fixing of 45W street light with GI bracket clamp and other accessories as required.
Supplying and fixing of modular regulator as required.
Supplying and fixing of modular 5/6A 5 pin socket as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including GI wire accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .