| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance BU 02 SFS FLATS OUTER RING ROAD PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical A 99 SECTOR 4 AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | - | - | Rejected-Technical NOT Qualified |
| 3 | Rejected-Technical BHUBANESWAR ORISSA 751020 | KHORDHA | ODISHA | 751020 | - | - | Rejected-Technical Not Qualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT Qualified |
| Sl No | Description | Qty | Unit | PNEUMATIC ENGINEERS PVT LTD. L1 |
|---|---|---|---|---|
| 1.00COST OF HVAC SYSTEMS - VRF - PARADIP PORT AUTHORITY HOSPITAL - EMERGENCY BLOCK | ||||
| 2.00Supply Part of Equipments | ||||
| 2.01 | Supply of City Multi inverter technology based minimum 14 HP Capacity VRF Systems -(5th Geneartion ) with scroll Compressor, Cooling only mode along with inter connection y-Branch for Module of each outdoor unit, Electrical/Electronic control systems, R410A/407C refrigerant, all complete as per scope of work. Temperature will be 24±4 degree celcius, RH 70% ±5%.
Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea | 1 | Nos | 6,00,000 ₹6,00,000 Lowest |
| 2.02Supply of VRF 4-Way Cassette type unit of minimum capacity as given below, with necessary items like expansion valve, cooling coil, filter section, blower, inbuilt with drain pump, etc. in all respect suitable for 24±4 degree celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea | ||||
| 2.03 | Nominal Capacity - 1.06 TR | 2 | Nos | 35,000 ₹70,000 Lowest |
| 2.04 | Nominal Capacity - 2 TR | 2 | Nos | 38,000 ₹76,000 Lowest |
| 2.05 | Nominal Capacity - 3.2 TR | 1 | Nos | 40,000 ₹40,000 Lowest |
| 2.06Supply of VRF Hi-Static Ductable split type unit of minimum Capacity as given below, with necessary items like expansion valve, cooling coil, filter section, blower etc. in all respect suitable for 24±4 degree Celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea | ||||
| 2.07 | Nominal Capacity - 0.8 TR | 2 | Nos | 30,000 ₹60,000 Lowest |
| 2.08 | Nominal Capacity - 0.6 TR | 3 | Nos | 25,000 ₹75,000 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
23 Jun 2022, 5:00 pmClosed
DR. PRAHALLAD PANDA,CMO,PPA HOSPITAL
DR. PRAHALLAD PANDA,CMO,PPA HOSPITAL
Supply, Installation, Commissioning and Comprehensive Maintenance (for 5 years) of HVAC System, and UVGI in Airborne Respiratory Infection Isolation Ward, Emergency Department, and Operation Theatre in PPA Hospital, Paradip Port on Turn-Key Basis
2022_MoS_692802_1
Medical/330/HVACMUVGI/21/671
Open Tender
Electrical Works
Works
120 days
Paradip
Refer Tender Document and e-TCN
3 documents required · 3 mandatory
₹3,000
Yes
As per Tender Document and e-TCN
₹2.2 L
Yes
8 Jul 2022
3 Jun 2022
24 Jun 2022
3 Jun 2022
23 Jun 2022
3 Jun 2022
3 Jun 2022 - 13 Jun 2022
Amount
COST OF HVAC SYSTEMS - VRF - PARADIP PORT AUTHORITY HOSPITAL - EMERGENCY BLOCK
Supply Part of Equipments
Supply of City Multi inverter technology based minimum 14 HP Capacity VRF Systems -(5th Geneartion ) with scroll Compressor, Cooling only mode along with inter connection y-Branch for Module of each outdoor unit, Electrical/Electronic control systems, R410A/407C refrigerant, all complete as per scope of work. Temperature will be 24±4 degree celcius, RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea
Supply of VRF 4-Way Cassette type unit of minimum capacity as given below, with necessary items like expansion valve, cooling coil, filter section, blower, inbuilt with drain pump, etc. in all respect suitable for 24±4 degree celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea
Nominal Capacity - 1.06 TR
Nominal Capacity - 2 TR
Nominal Capacity - 3.2 TR
Supply of VRF Hi-Static Ductable split type unit of minimum Capacity as given below, with necessary items like expansion valve, cooling coil, filter section, blower etc. in all respect suitable for 24±4 degree Celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea
Nominal Capacity - 0.8 TR
Nominal Capacity - 0.6 TR
Installation Part
Installation , testing and commissioning of minimum 14 HP Capacity VRF System as at "Point No 2.01" above
Installation , testing and commissioning VRF 4-Way Cassette type unit as at "Point No 2.02" above with minimum capacity as given below:
Nominal Capacity - 1.06 TR
Nominal Capacity - 2 TR
Nominal Capacity - 3.2 TR
Installation, testing and commissioning VRF Hi-Static Ductable split type unit as at "Point No 2.06" above with minimum Capacity as given below:
Nominal Capacity - 0.8 TR
Nominal Capacity - 0.6 TR
Supply, Installation,testing and commissioning of Suction and liquid line of 18/20 Gauge copper piping with 13mm /19 mm thik Nitril rubber Insulation-Class O Grade , with all respect for complete commissioning of systems. Copper Pipe. Make: Reputed
Supply , Installation,testing and commissioning of 2 core X 1.5 Sqmm Electrical communication cabling with conduit pipe, and clamps etc. all complete. Make : Reputed
Supply, installation and commissionig of PVC Drain water pipe with Insulation and required ancillary items, all complete. Make : Reputed
Refrigerant R410a/407C Gas for Commissioning of the VRF Systems
Transportation, loading, unloading of Machines and Materials
HVAC SYSTEMS - VRF - PARADIP PORT AUTHORITY HOSPITAL - O T BLOCK
Supply Part of Equipments
Supply of City Multi inverter technology based minimum 14 HP Capacity VRF Systems -(5th Geneartion ) with scroll Compressor, Cooling only mode along with inter connection y-Branch for Module of each outdoor unit, Electrical/Electronic control systems, R410A/407C refrigerant, all complete as per scope of work. Temperature will be 24±4 degree celcius, RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea
Supply of VRF 4-Way Cassette type unit of minimum capacity - 1.06 TR with necessary items like expansion valve, cooling coil , filter section, blower, inbuilt with drain pump, etc. in all respect suitable for 24±4 degree celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea
Supply of VRF Hi-Static Ductable type unit of minimum Capacity 4.6 TR with necessary items like expansion valve , cooling coil , filter section , blower etc in all respect. Temperature will be 24±4 degree celcius, RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea
Installation Part
Installation , testing and commissioning of minimum 14 HP Capacity VRF System as at "Point No 3.02" above
Installation , testing and commissioning VRF 4-Way Cassette type unit of minimum-1.06 TR capacity as at "Point No 3.03" above
Installation, testing and commissioning VRF Hi-Static Ductable type unit of minimum Capacity 4.6 TR as at "Point No 3.04" above
Supply, Installation,testing and commissioning of Suction and liquid line of 18/20 Gauge copper piping with 13mm /19 mm thik Nitril rubber Insulation-Class O Grade, with all respect for complete commissioning of systems. Copper Pipe Make: Reputed
Supply , Installation,testing and commissioning of 2 core X 1.5 Sqmm Electrical communication cabling with conduit pipe, and clamps etc. all complete.
Supply , installation and commissionig of PVC Drain water pipe with Insulation and required ancillary items, all complete. Make : Reputed
Refrigerant R410a/407C Gas for Commissioning of the VRF Systems
Supply and installation of AISI 316 grade 22 Gauge thickness Stainless steel Ducting with supporting items like Thread rod , Perforated channel, Fastner, nut-bolt etc, all complete, as required in all respect. Make: Reputed
Supply and installation of 13 mm thick Nitril rubber O class insulation added self Alluminium foil face with all types of ancillary items. Make : Reputed
Transportation, loading, unloading of Machines and Materials
PPA COVID WARD INFRASTRUCTURE BOQ
WALL Antibacterial homogenous 1mm wall vinyl covering along with Smooth putty and primer on the wall .
Anti bactrial anti static FLOOR of 2mm Homogenous antibacterial vinyl with welding on the edges, Copper stripping to be done and proper earthing to be done.: The 2 mm homogeneous material incorporates homogenousity throughout its full thickness and should carry warranty of 5yrs after laying. The product should comply with EN 649. The product is non-reactive to residual indentation with a value ≤ 0,02 mm (EN 433) The flooring complies with the EN 649 (34-43) offering a group P-wear rating suitable for heavy duty traffic areas and Bfl-s1 fire resistance. The product is non-emissive of volatile organic compounds with < 10 Micro Gm(TVOC after 28 Days ISO -16000-6 ). The material should be laid after doing self levelling with self levelling compound.
Self Levelling - Floor.
Clean room doors: Manully operated Clean room Single leaf Hinge door (1200mm wide 2100mm height) complete with double toughned glass vision window in leaf. Made of SS-304 With Gasket and drop seal. Make : Metaflex
Clean room doors: Manully operated Clean room Single leaf Hinge door (900 mm wide 2100mm height) complete with double toughned glass vision window in leaf. Made of SS-304 With Gasket and drop seal. Make : Metaflex
Clean room doors: Manully operated Clean room Double leaf Hinge door (1500mm wide 2100mm height) complete with double toughned glass vision window in leaf. Made of SS-304 With Gasket and drop seal.
Clean Room LED Light for Isolation ward Make: Philips
CEILING For Isolation Wards : 6MM Calcium silicate greed ceiling with antibacterial paint of Jutton/Sika/ESDDE or equivelant
HVAC SYSTEMS - VRF - PARADIP PORT AUTHORITY HOSPITAL - COVID WARD
Supply Part of Equipments
Supply of City Multi inverter technology based following Capacity VRF Systems -(5th Geneartion ) with scroll Compressor, Cooling only mode along with inter connection y-Branch for Module of each outdoor unit, Electrical/Electronic control systems, R410A/407C refrigerant, all complete as per scope of work. Temperature will be 24±4 degree celcius, RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea
Nominal Capacity - 14 HP
Nominal Capacity - 20 HP
Supply of VRF 4-Way Cassette type unit of minimum capacity as given below, with necessary items like expansion valve, cooling coil, filter section, blower, inbuilt with drain pump, etc. in all respect suitable for 24±4 degree celcius temperature and RH 70% ±5%. Make: Daikin/Thosiba/O-General/Mitsubishi/Hitachi/Panasonic/Johnson Controls/Midea
Nominal Capacity - 0.8 TR
Nominal Capacity - 2 TR
Nominal Capacity - 2.5 TR
Installation Part
Installation , testing and commissioning of VRF System as at "Point No 5.02" above with minimum capacity as given below:
Nominal Capacity - 14 HP
Nominal Capacity - 20 HP
Installation , testing and commissioning VRF 4-Way Cassette type unit as at "Point No 5.05" above with minimum capacity as given below:
Nominal Capacity - 1.5 TR
Nominal Capacity - 2 TR
Nominal Capacity - 2.5 TR
Supply, Installation,testing and commissioning of Suction and liquid line of 18/20 Gauge copper piping with 13mm /19 mm thik Nitril rubber Insulation-Class O Grade, with all respect for complete commissioning of systems. Make: Reputed
Supply, Installation, testing and commissioning of 2 core X 1.5 Sqmm Electrical communication cabling with conduit pipe, and clamps etc. all complete. Make : Reputed
Supply, installation and commissionig of PVC Drain water pipe with Insulation and required ancillary items, all complete. Make : Reputed
Supply and installation of AISI 316 grade 22 Gauge thickness Stainless steel Ducting with supporting items like Thread rod, Perforated channel, Fastner, nut-bolt etc, all complete, as required in all respect. Make: Reputed
Supply and installation of 13 mm thick Nitril rubber O class insulation added self Alluminium foil face with all types of ancillary items. Make : Reputed
Supply and installation of Alluminium powder coated Diffuser/Grill for Return Air with damper with all tyeps of ancillary items .
Supply, Installation, testing and commissioning of 3 stage Filter (10 micron Pre-Filter, 5 micron Fine Filter and 0.03 Micron Hepa Filter) fitted cabinet type Axial Flow exhaust fan with Centrifugal Backward/forward Curve blower, Fan as of below-mentioned capacity for Negative pressure Zone. [Fan design & Static Pressure may be change as per the site condition or Filter may be installed in ducting as required]
250 CFM (Static pressure 85 mm)
200 CFM (Static pressure 85 mm)
100 CFM (Static pressure as 15 mm)
Supply, installation of Fire retardant Flexible Canvas Connection for Exhaust Fan Mouth connection with required ancillary itmes
Supply, Installation, testing and commissioning of Fresh air fan, the Fan will be made by Single stage Filter (10 micron Pre- Filter), cabinet type Axial Flow type, Centrifugal Backward/forward Curve blower, Ceilling suspended type, Fan capacity is 300 CFM 30 MM Static pressure for possitive pressure Zone. The system will be comfortable with UVGI inside the fan to kill the bacteria growth.
Refrigerant R410a/407/C Gas for Commissioning of the VRF Systems
Transportation, loading, unloading of Machines and Materials
Comprehensive Annual Maintenance Contract of entire HVAC System (for the HVAC System of Air Borne Respiratory Infection Isolation Ward, Emergency Block, and OT Block) for Five Years
For 1st Year
For 2nd Year
For 3rd Year
For 4th Year
For 5th Year
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .