Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹18.7 L+₹1.9 L (11.3%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹22.3 L+₹5.5 L (32.5%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹22.7 L+₹5.9 L (34.9%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹23.6 L+₹6.8 L (40.6%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
4 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) MANKHURD
GE (NW) MANKHURD,MUMBAI-400088
COMPREHENSIVE REPAIR MAINTENANCE OF SECURITY LIGHTS, GARDEN LIGHTS AND ALLIED WORKS AT TS MAHUL AND SEWRI UNDER GE (NW) MANKHURD
2022_MES_556228_1
8176/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹52,000
Yes
15 Feb 2023
7 Oct 2022
7 Nov 2022
7 Oct 2022
4 Nov 2022
21 Oct 2022
Amount
Excavation in trenches not exc 1.5 mtr wide & n.exc 10 sqm cm on plan and not exc 1.5 mtr in depth and getting out in soft / loose soil
All as per ser item No 01 above but depth exc 1.5 m upto 3.0 m
Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil.
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point all as directed by Engr - in- Charge.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by EIC. Note : Sand after punning down will be measured
Supply and laying precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.. Make - Methab Indore Tiles or Conforming to IS Marked.
Laying only un-reinforced precast concrete cable cover class LV, type-I, flate size 250mm x 150mm x 40mm laid cable cover obtained vide Ser Item No 8 to 12 shall be reused.
Taking out old unserviceable underground cable XLPE insulated, PVC sheathed armored heavy duty aluminum conductor LT 1100 Volts grade of size 4 Core 10 Sqmm, fixed on pole, wall and laid in trenches etc after disconnecting Note - Excavation and earth work will be mesured and paid seprately.
All as per item no 8 above but of size 4 core 16 Sqmm
All as per item no 8 above but of size 3.5 core 25 Sqmm
All as per item no 8 above but of size 3.5 core 95 Sqmm
All as per item no 8 above but of size 3.5 core 240 Sqmm
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size:- 10 Sqmm x 4 core.
All as per item No 13 above but of size 4 core 16 Sqmm
All as per item No 13 above but of size 3.5 core 25 Sqmm
All as per item no 13 above but of size 3.5 core 95 Sqmm
All as per item no 13 above but of size 3.5 core 240 Sqmm
M&L for straight through joint (epoxy) suitable for 3 ½ / 4 core up to 95 Sqmm size underground cable all as specified and directed.
M&L for straight through joint (epoxy) suitable for 3 ½ /4 core 95 to 240 Sqmm size underground cable all as specified and directed.
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
S& F in replacement of GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x 5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed by Engr-in-Charge..
S&F of HDPE pipe 75 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etcall as directed by Engr-in-Charge.
Supply and fix in replacement of FRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channel including making connections all as specified and directed by Engineer –in –Charge. Make - confirm to Cat No KF 1616 G of Hensel/ National / Sintex .
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts, all For interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as directed. Make :- POLYCAB / PLAZA / KEI.
M&L for Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc taking down old unsv cable all as Directed. Make :- POLYCAB / PLAZA / KEI
Dismantling and disconnecting the electric connections and taking down the following burnt / unserviceable MCCB from panel boards of any capacity all as specified and directed by Engineer –in –Charge.
M&L in repairs MCCBs 3 Pole 250 Amps,36 KA including connecting up electrically with proper lugs glands etc all as specified and directed by Engineer –in –Charge
M&L in repairs MCCBs 3 Pole 200 Amps,36 KA including connecting up electrically with proper lugs glands etc all as specified and directed by Engineer –in –Charge
M&L in repairs MCCBs 3 Pole 100 Amps,16 KA including connecting up electrically with proper lugs glands etc all as specified and directed by Engineer –in –Charge
M&L in repairs MCBs FP 16 amp to 63 Amps,16 KA including connecting up electrically with proper lugs glands etc all as specified and directed by Engineer –in –Charge
Supply and fix 3 pole power contactor 32 A , coil voltage 230 V
M&L in repairs for 24 Hrs 240 V FM1 Quartz type daily timer switch for controlling street lights contactors all as specified and directed by Engineer –in –Charge. Make : L & T/ Indo Asian
Dismantling of PCC foundation / coping from pole not exc 1.65 below ground level for removing of pole all as specified and directed by Engineer –in –Charge
M&L for pcc 1:2:4 type B-1 using 20 mm graded stone agrregates as in pedestal of pole/ strut and in copping including necessary form work and finishing exposed faces of concrete even and smooth using extra cement all as directed by engineer in charge .
Supply and fix in replacement 8 Watt LED Bollard garden light fitting with efficient high output COB LED, pressue die cast powder coated housing with PC diffuser driver nut bolt ,washer base plate foundation 0.3 mtrx0.3 mtr x.40 mtr by PCC 1:2:4 type B-1 using 20mm grade stone aggegates of size including excavtion and earth work , provision of GI bend of size 50MM dia in the PCC for cable entry the fitting shall cvonform to cat No-CONEBL8WLED857PSYMTOPC of Havells equivalent from Philips, bajaj/CG.
Suply and fix New generation , post-top LED warm light 15/ 20 W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 40 mm dia in the PCC for cable entry the fitting with nut bolts,washer all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.
Suply and fix New generation , post-top for 360 degree indirect lights with IP 65 LED light 40W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light fitting with nut bolts,washer all as specified and directed in EIC. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
S & F in replacement of security light fitting/Building security light LED type 60 watts with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc all as directed by Engineer in charge. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
S&F in repair of building Security light fitting 35 Watt made up of pressure die cast aluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make : Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
S&F in Repairs 36 W LED recessed full lit luminaire with glare free uniform illumination with longer life and less maintainance 2x2 fitting mounted direct/indirect architectural luminaire including connecting 1.5 Sqmm white colour suitable for false ceiling fixing arrangement all as specified and directed in EIC. Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
S & F in repair/replacement of LED Driver 60 Watt Suitable for street light fitting complete all as specified and directed. Make:- Crompton or Equivalent from Havells /Bajaj
S & F in repair/replacement of LED Driver 30/35 Watts Suitable for Building security light fitting complete all as specified and directed. Make:- Crompton or Equivalent from Havells /Bajaj
S & F in repair/replacement of LED Driver 36 Watts (2'x2') Suitable for ceiling light fitting complete all as specified and directed. Make:- Crompton or Equivalent from Havells /Bajaj
Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers and LED 36/70 watt after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LED will be measured and paid separately on respective item of Sch 'A' here-in-after].
M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using comutrised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Note: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately. (ii) Cable joint will be measured and paid seperetely. (iii) Additional lenth of cable required at site for jointing will be measured and paid seperately.
M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as directed.
Supply and Fix in repairs MCCB 100 Amps 4 pole, 415 Volt IN SHEET STEEL ENCLOSURE in open construction, panel mounted 0n wall with base plate for mounting in panel, including taking down of old MCCB with enclosure and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
Supply, install, in repair/ renewal feeder piller box outdoor type, IP-54 protection CPRI approved, factory fabricated, cubical panel wall mounted, self supported, free standing type, made out of 3.15m thick CRCA sheet with locking arragement, suitable for 3 phase, 4 wire, 415 volt, 50HZ, AC supply including suitable size copper conductor control wiring and powder coating with connecting the cables with necessary cable glands, lugs etc proper arrangement for veritilation complete with and including the following accessories :- Location: NSD Sewri & TS Mahul (i) Copper bus bar Phases & Neutral for 200 Amps- 01 set (a) MCCB 4 pole 25 KA 100A - 1 Nos (b) MCB TPN 40 Amp 10 KA- 01 Nos (c) MCB SPN 32 Ampc 10 KA - 01 Nos
Supply and Fix in repairs Change Over FP 250 Amps 415 Volt IN SHEET STEEL ENCLOSURE in open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
Comprehensive AMC of three phase 60 KVA UPS 3 phase,including servicing/replacement of worn out parts like PCB, IGBT based, Diode, Capacitors,relay,cooling fan,indicators,connectors,lugs,wires,switches,fuses and to attending all breakdown calls and check all electronic component/cards,checking of rectifier/inverter logic boards,adjust battery charging current,cheking of auto transfer facility between inverter and bypass & bypass to UPS, verification/setting/ rectification of LCD mimics alarms,indications, UPS &battery changover test. Location: RUKMANI Bldg Mahul
Comprehensive AMC of 30 KVA 3 phase,415 V Servo voltage stabilizer (6 Nos) including replacing of all components releted with AVR following:- (a) I.C. Electronic control card (b) Control Transformer (c) R.C. Network (d) Main big gear (e) Toggle switch (f) Indication Lamp (g) Voltmeter (h) A.C. synchronous Motor (j) Dimmer stopper all as specified and directed by Engineer –in –Charge. Note: (i) The rate quoted shall be inclusive transportation,material and labour,including all defective spare makeas per existing,complete. (ii) Attending of fault within 8 hours of intimation to avoid disruption of receive to user technical requirement.Delay of attending of fault by more than 01 day will invite penalty charge of 1000/hr.
Supply and fix in repairs Power Capacitors of Rating 100 KVAR 415 Volt in repairs Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR with merer system conforming to IS 13340 and 13341 ISI Marked all as specified.
All as per item No 59 above but Power Capacitors of Rating 50 KVAR 415 Volt
All as per item No 59 above but Power Capacitors of Rating 25 KVAR 415 Volt
All as per item No 59 above but Power Capacitors of Rating 10 KVAR 415 Volt
All as per item No 59 above but Power Capacitors of Rating 5 KVAR 415 Volt
M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed.
Supply& fixing in repairs for mild steel work confirming to Fe-290, GdeE-165 in stairs/ladders including stringes, treads, landing, balusters, hand rails etc including applying two coat of paint over one coat of red oxide complete all as specified and directed.
M&L for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 10 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 8mm dia bars as in binders, spacers, strippus including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed.
Dismantling old PCC Pole/ Steel Pole and Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed.
Supply and fix in repairs Halogen lamp with fixture complete of capacity 500/ 1000 watt operating on 230v, single phase, AC, 50 Hz supply complete all as specified and directed. Note : A sum of Rs 17045.00 towards sch of credit shall be deducated to arrive the contract sum.
sapana enterprises
Atharva Enterprises
Radha Engineering Services
M/s Bhagirathi Electricals
Shree Ayyappa Engineering
A P ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .