Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical PLOT NO 1884 5128 NEAR DAV SCHOOL NAYAPALLI BBSR 751012 NAYAPALLI NAYAPALLI NAYAPALLI KHURDA KHORDHA ODISHA 751012 | KHORDHA | ODISHA | 751012 | Accepted-Technical As per attached data sheet |
| 2 | Accepted-Technical AT BARIMAL PO HATIBARI PS SUKINDA DIST JAJPUR PIN 755018 | JAJAPUR | ODISHA | 755018 | Accepted-Technical As per attached data sheet |
| 3 | Accepted-Technical | Accepted-Technical As per attached data sheet |
| 4 | Accepted-Technical | Accepted-Technical As per attached data sheet |
| 5 | Accepted-Technical AT WARD NO 28 PO BHOI NAGAR PS SAHEED NAGAR DIST KHURDHA | KHURDHA | ODISHA | Accepted-Technical As per attached data sheet |
Tender Value
₹2.6 Cr
EMD Value
₹2.6 L
Closing Date
2 Mar 2026, 5:00 pmClosed
Director of Physical Plants
OUAT CAMPUS, SIRIPUR, BHUBANESWAR
Construction of 60 seated Boys Hostel along with furnishing at OUAT Bhubaneswar Composite construction portion only
2026_OUAT_126120_1
05/2025-26
Open Tender
Civil Works - Buildings
Percentage
365 days
Bhubaneswar
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
DPP, OUAT
₹2.6 L
Yes
28 Apr 2026
16 Feb 2026
7 Mar 2026
16 Feb 2026
2 Mar 2026
16 Feb 2026
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as g (AR, P-158/37)
Approach road
Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge
Ground floor
Approach road
Rcc drain with coverslab
Compound wall
Construction of granular sub-base by providing Gr.-VI material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller.
Approach road
Sand filling in foundation and plinth including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights).
Ground floor
Approach road
Rcc drain with coverslab
Compound wall
Filling area with excavated earth materials including labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge.
Ground floor
Compound wall
Conveyance of excavated earth materials by mechanical means including 5km lead complete including all labour, materials & royality etc. complete as per direction of EIC.
Ground floor
Rcc drain with coverslab
Providing & laying plain cement concrete (1:3:6) using 4cm size metal etc. complete including all labour, materials & royality etc. complete as per direction of EIC.
Ground floor
Rcc drain with coverslab
Compound wall
Providing & laying plain cement concrete M/15 using 4cm and down size chips etc. complete including all labour, materials & royality …….etc. complete as per direction of EIC.
Approach road
Providing of 60 mm thick factory made cement concrete interlocking paver block of M-30 grade and approved make,varity colour and size made by block making machine with strong vibratory compection of approved design and shape ,laid in required colour and pattern over 50mm thick compected bed of coarse sand ,filling the joints with fine sand etc,all T&P etc complete as per direction of Engineer- in-charge.
Approach road
Providing lifting, hoisting and laying R.C.C. of M-20 Grade to base of columns and footing, columns, beams, plinth band, lintels, chajja, shaft, fins, roof slabs, balconies, stair cases, parapets, window sills, lofts, railing, jally, copping or in places as shown in the drawing for all floors with 20mm and down graded size black hard crusher broken ships of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth (if required providing plaster with cement mortar (1:4) wherever necessary without any extra cost) including rigid smooth centering and shuttering, scafolding, watering (excluding reinforcement bars) and curing for required period including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge.
Ground floor
a)Base Footing
(b) Column in s/s
(c) Plinth beam
(d) Lintel band
(e) Chajja( at lintel level & window sill level )
(f) Shelves
(g) Stair case
(h) Roof Beam
(i) Roof slab
First floor
(a) Column in s/s
(b) Lintel band
(c) Chajja( at lintel level & window sill level )
(d) Shelves
(e) Stair case
(f) Roof Beam
(g) Roof slab
Head room
(a) Column in s/s
(b) Lintel band
(c) Chajja( at lintel level & window sill level )
(d) Roof Beam
(e) Roof slab
Rcc drain with coverslab
A) Drain bed
B) Wall
C) Cover slab
Compound wall
A)Base Footing
B)Plinth beam
C)Column in Super Structure
D)Coping
Supplying,Cutting,straightening of steel HYSD (Fe- 500) conforming to (IS- 1786) with bending, binding, cranking, hooking, welding or jointing if necessary & tying the grills and placing in position as required for the Rod work in all floors and & for providing fan hooks hosting lowering ,& laying steels including cost conveyance ,taxes & royalties of all materials and binding wires of 18 to 20 gauge & cost of all labour T&P required for the work etc. Complete in all respect as per the direction of Engineer in charges ( payment will be made on weight of MS rod or tor steel only basing on the co- efficient of MS rod or tor steel bars approved by SAIL/ TATA/ competent authority and (No separate payment will be made towards the cost of binding wires over lapping, wastage, coupling, welded, joints , spacer bars, ,chairs stays, hangers and annealed steel wires or other methods for binding and placing etc.)
Ground floor
First floor
Head room
Rcc drain with coverslab
Compound wall
Fly ash brick masonary of size 25mmX12mmX8mm and crushing strength not less than 75 kg/cm2 in C.M.(1:6) in F&P including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge.
Ground floor
Compound wall
Fly ash brick masonary of size 25cmx12cmx8cm and crushing strength not less than 75 kg/cm2 in C.M.(1:6) in Super structure including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge.
Ground floor
First floor
Head room
Compound wall
Fly ash brick masonary of size 25cmx12cmx8cm and crushing strength not less than 75 kg/cm2 in C.M.(1:4) in Super structure including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge.
Ground floor
First floor
Supplying of M.S. Grill made out of structural steel, flats, plates, bars confirming to IS for windows, ventilators etc. as per drawing and design, fixed to walls with clamps including priming 1 coat with all kdamages in walls and floors etc. including cost of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc.as per the direction of the Engineer in Charge.
Ground floor
First floor
Head room
Compound wall
Supplying fitting, fixing of 125 mm x65mm ( after moulding ) well blend beautiful WPC ( Wood plastic composite choukath in door opening area tha wall surface of WPC Chaukaths 150mm anchor fastner screw cutting the holes filling the cutting holes in cement concrete (1:2:4) etc all complete.
Ground floor
First floor
Providing and fitting, fixing of 32 mm thick flush door shutters conforming to IS 2002 (Part-1) decorative type, core block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both face of shutters inclussive of 4 nos of stainless steel Butt Hinges (100mm x 60mm x 2.5mm) 40mm stainless steel screws. Cylindrical Look(Godrej-9843), Tower Bolts SS 10mm X 300mm (Bathroom)(Godrej 3264), PVC Door Buffer with SS Screw, teak wood lipping around the edges & paste with 1.5mm thick lam8inate on both side of the flush door, etc., including the cost of all materials, hardware fittings, cost of all labour, convence, loading, unloading, T&P, etc , complete as per the direction of Engineer-in charge.
Ground floor
First floor
Supplying fitting fixing of Un-plasticcide Poly Vinyl Chloride(UPVC) (FENESTA/NCL VEKA LTD.) Slidin Door Series duly Manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mm 2.5mm capable of mounting single galazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm perfabricated & welded through fusion welding the window frame shall be with 6mm thick clear thougherned glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistance and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTMD 638-14, EN-477-95 and other applicable codes and standards.
Ground floor
Supplying fitting fixing of Un-plasticcide Poly Vinyl Chloride(UPVC) (FENESTA/NCL VEKA LTD.) Three Track-Three Panel slidind window-60 Series duly Manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mm 2.5mm capable of mounting single galazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm perfabricated & welded through fusion welding the window frame shall be with 6mm thick clear thougherned glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistance and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTMD 638-14, EN-477-95 and other applicable codes and standards.
Ground floor
First floor
Supplying fitting fixing of Un-plasticcide Poly Vinyl Chloride(UPVC) (FENESTA/NCL VEKA LTD.) Ventilator Series duly Manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mm 2.5mm capable of mounting single galazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm perfabricated & welded through fusion welding the window frame shall be with 6mm thick clear thougherned glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistance and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTMD 638-14, EN-477-95 and other applicable codes and standards.
Ground floor
First floor
Providing 6 mm thick cement plaster in cm (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, sundries, tols and plants etc. complete as per the driection of the Engineer in Charge.
Ground floor
First floor
Head room
Compound wall
Providing 12mm thick cement plaster in cm (1:6) on the rough surface/ plumbed surface of masonry racking out of joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge.
Ground floor
First floor
Head room
Compound wall
Providing 16mm thick cement plaster in cm (1:6) on the rough surface of masonry walls for all floors including racking and joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge.
Ground floor
First floor
Head room
Compound wall
Providing 12mm thick cement plaster in cm (1:4) on the rough surface of masonry walls for all floors including racking and joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge.
Ground floor
First floor
Supplying, fitting and fixing Kota Stone ( AboveTo 0.1 Sqm ) in floors of approved make laid on 20mm thick C.M (1:4) & filling joints with white cement of approved quality including cost of all materials complete as per the driection of the Engineer in Charge.
Ground floor
Supplying, fitting and fixing Kota Stone Dado on 12 mm thick bed of cement mortar (1:3) jointed with neat cement slury mixed with pigment to match the shades of the tiles including all taxes etc complete.
Ground floor
Supplying and fixing of precast kerb stone of size 600mmx300mmmx150mm of m/30 grade of approve make etc complete as per direction of Engineer- in-charge.
Approach road
Supplying, fitting and fixing GraniteSlab (0.4 to 1.00 Sqm ) in floors of approved make laid on 20mm thick C.M (1:4) & filling joints with white cement of approved quality including cost of all materials complete as per the driection of the Engineer in Charge.
Ground floor
First floor
Supplying & fixing of vitrified tiles on 20 mm thick bed of cement mortar (1:4) jointed with neat cement slury mixed with pigment to match the shades of the tiles including all taxes etc complete.
Ground floor
First floor
Supplying & fixing of vitrified tiles Dado on 12 mm thick bed of cement mortar (1:3) jointed with neat cement slury mixed with pigment to match the shades of the tiles including all taxes etc complete.
Ground floor
First floor
Supplying, fitting and fixing Chequered tile flooring in floors of approved make laid on 20mm thick C.M (1:4) & filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 10 sq.mt.)
Ground floor
Supplying fitting fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balstrade of size 32mmx32mmx2mm @0.90mtr C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification, buffing, pollishing etc with cost, conveyance taxex of all materials, labour, T&P etc. required for the complete in all respect.
Ground floor
First floor
Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.
Ground floor
First floor
Wall painting TWOcoats with plastic emulsion paint over a coat of wall primer of any approved shade including cost of all charges etc..
Ground floor
First floor
Head room
Finishing wall surface with two coats of weather coat over a coat of cement priming including cost and conveyance of all materials, labour T&P, hire charges of machine, all taxes etc all completes in all respects as per the direction of Engineer charges.
Ground floor
First floor
Head room
Approach road
Compound wall
Painting two coats of synthetic enamel paint over including cost and conveyance of all materials, labour T&P, hire charges of machine, all taxes etc all completes in all respects as per the direction of Engineer charges.
Ground floor
First floor
Head room
Providing enamel painting two coats over a coat of primer including all cost, conveyance,royalty & taxes etc.compete of all materials to work site as per specification approved by the department & direction of Engg-in-charge.
Compound wall
Providing fitting and fixing of 100mm dia rain water pipe including all hardware fittings etc complete .
First floor
Head room
Providing cow catcher made out 100mm GI pipe (50x5)mm M.S flat (150x200x100)mm M.S joist including welding lying fitting and fixing and placing over the drain wall
Rcc drain with coverslab
Providing 25mm thick Grading Concrete in C.M(1:2:2) with on new roof slab including cost of materials , labour, T&P all comp.
Ground floor
First floor
Head room
Providing Antitermite treatments as per ISI specification including making holes 3'0" C/C both ways injecting chemical with water in propertion(1:20) or any approved propertion by the EIC & treatment to choukath sides & wall junction. Cost & conveyance of all materials, labours, T&P etc complete. as per direction of EIC.
Ground floor
ELECTRICAL PART Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
GROUP-A
GROUP-B
GROUP-C
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & coverincluding supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole+E-DP plug & socket DB with 32A DP MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge.. . Make-Legrand/ Siemens/Schneider
Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole+E-4P plug & socket DB with 32A 4P MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge.Make-Legrand/ Siemens/Schneider
Supplying and fixing 63 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole+E-4P plug & socket DB with 63A 4P MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge.Make-Legrand/ Siemens/Schneider
Sub-Head II (Light fitting Fixture & Fan) Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)
Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of not more than 25W and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years.
Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 36W (595X595X70MM)and system lumens output not less than 4680 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years.
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
BDBS,DB,AC DB,FLOOR PANELS,MCBS Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years
Supplying and fixing 20 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..
Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 4P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 3 years.
Supplying and fixing 25Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years.
Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years.
(Earthing) INSTALLATION Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years
Supplying,installation,testing & commissioning of materials and installation of Copper earth plate 600mmx600mmx3.15mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
CABLING AND END TERMINATION MAIN AREA Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
3.5core x 95 sq mm
4core x 16 sq mm
4 core x 6 sq mm (for small power)
3.5core x 35 sq mm
3.5core x 50 sq mm
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
4 core x16sq mm
3.5 core x35 sq mm
3.5 core x95 sq mm
Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
50 mm dia
PANELS MAIN PANEL S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for EQ. circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. BUILDING VRF AC)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.
In commer - 01 no 125A 4P MCCB 25kA, with ROM & S. Link. withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) (Icu=100%Ics)with shunt trip.
In commer-2-01 number of 100A 4P Icu=100%Ics,36kA LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) (DG 125 KVA INCOMMER)
In commer-2- 01 no of 100A 4P onload changeover switch (20 KVA DG 01 NO)(Make-C&S/LK(L&T)/Siemens/Schneider)
Busbar- 04 numbers of 250Amps, Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
Out going- 06 nos 63A 4P MCB 10kA,C series,415V for power BDB. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9
Out going- 06 nos 63A 2P MCB 10kA,C ,240V series for power BDB. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9
Out going- 02 numbers of 125A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)
SERVICE PANEL S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for EQ. circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. BUILDING LIFT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.
In commer- 01 numbers of 63 Amps 4P MCCB. Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 (Icu=100% Isc) with shunt trip & axulary for BMS & mechnical inter locking for one incommer source to other.
Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
Out going- 04 nos 32A rating,10KA breaking capacity,C series, 2P MCB UPS Light load for each floor.Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9
Out going- 03 nos 32A rating,10KA breaking capacity,C series, 4P MCB OT/ICU POWER/OT MACHINE OR Bed head panel.Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of 0-100Amps Ammeter Digital type & CTS.(DIGITAL)
(iii) 01 set of 0-500 voltmeter Digital type.(DIGITAL)
NB- This panel should have proper earth by suitable rated copper flat.
CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
Subhead- 1 (Lan System) Data Networking System:-Supply and laying of 4 pair Cat6 U/UTP Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco / Legrand / Panduit
Supply and Installation of Cat6 I/O with Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Tyco / Legrand / Panduit I/O Single
Supply and installation of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Tyco / Legrand / Panduit
Supply and installation of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Tyco / Legrand / Panduit. 1mtr Lenghth
2mtrs Length
Supply and installation of Dual band 802.11ax WiFi6 Dual Band Access Point. Complying PoE+ for power, with inbuilt on premise virtual controller as well cloud based controlling and administration of WiFi systems All hardware should supplied with necessary mounting brackets and IN power cord with 3 years of comprehensive onsite warranty. Make: Cisco/Digisol/Netgear
Supply and installation of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco/Digisol/Netgear
Supply and laying of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Tyco / Legrand / Digisol
Supply and installation of 24 Port Rack mount Draw Type Loaded LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 24 SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,ADAPTER, SM, SIMPLEX SC, PC TYPE ,Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core and PIGTAIL, SM (OS2), SIMPLEX SC, PC TYPE, 2M, LSZH ,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db ,LSZH Jacket-Reduced Toxic Gasses Emitted During Combustion , 100% Factory Tested , Low Insertion Loss and Return Loss.Make: Tyco / Legrand / Digisol
Supply and installation of 6 Port Rack mount Draw Type Loaded LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 6 SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,ADAPTER, SM, SIMPLEX SC, PC TYPE ,Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core and PIGTAIL, SM (OS2), SIMPLEX SC, PC TYPE, 2M, LSZH ,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db ,LSZH Jacket-Reduced Toxic Gasses Emitted During Combustion , 100% Factory Tested , Low Insertion Loss and Return Loss. Make: Tyco / Legrand / Digisol
Supply and installation of OFC PATCHCORD, SM (OS2), DUPLEX LC-SC, PC TYPE, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Tyco / Legrand / Digisol
Supply and installation of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make: Valrack/Rittal/ APW
Supply , Installation, testing , commissioning of 1 KVA online UPS ( Make: APC/Numeric/Vertiv)
IP CCTV Surveillance System:Suppy and installation of 5 megapixel base Dome camera support video compression H.26+/H.265(HEVC)/H.264+/H.264/MJPEG, built-in intelligent analytics-region Entran, Region Exiting, Advance Motion Detection, Tamper Detection, Line Crossing, Loitering, Object left, Object removed. People counting-Count the number of people entering or exiting, up to 4 detection areas for regional people counting. Built-in Microphone. IP67 and IK10 compliant 120dB super WDR, IR Distance of upto 50mtr Make- Honeywell 20 series/pelco/axis
FIRE FIGHTING Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) . a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 . b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325. c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d)Suitable cement concrete foundation duly plastered and with anti vibration pads. Make-wilo/kirloskar/Grundfoss 450 lpm at 35 m Head
Supplying, laying, testing & commissioning of PVC outer sheath, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray / Hume pipe / in trenches / on walls / floor etc. as required. For cables laid out door the rate shall exclude earth excavation providing brick and sand protection, refilling and compacting the earth. 16 sq.mm 4 Core Aluminium Cable (For Booster Pump)
G.I. Earthing strips of 50mm x 6mm thick, strip shall be run on floor / ceiling / walls, from the equipment to the nearest Earth pit with neccessory accessories as required. ( Earth pit shall be executed by other agencies).
Supplying, installing, testing and commissioning 0 to 16 Kg/ cm2 ON/OFF digital pressure switch in delivery line of pump along with control wiring for auto starting and auto stopping of hydrant /sprinkler and jockey pumps.Make-Make-Indfoss/grundfoss/Danfoss
Providing & fixing dial type (150 mm dia) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-15 Kg/cm2.Make-H.guru/G.Guru
Providing, fixing, testing & commissioning of C.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washers complete . [PN -1.6 rating (16kg/cm2)]. Make-Audco/Zoloto/Kirloskar/Leader
100 mm dia
Providing, fixing, testing & commissioning of flanged end 'y'strainer made from MS body with bottom and top removable flanges with nuts, bolts etc having filteration area at least 6 times the cross sectional area of the pipe. Make-Audco/Zoloto/Kirloskar/Leader
100 mm dia
Providing, fixing, testing & commissioning of C.I. dual plated Non-return valve [PN 1.6 Rating (16kg/cm2] complete 2 nos. matching flanges, rubber insertion, with nuts, bolts and washers etc of following sizes . Make-Audco/Zoloto/Kirloskar/Leader
100 mm dia
INTERNAL HYDRANT SYSTEM Fixing, testing and commissioning of heavy class MS pipe, IS : 1239 marked with all necessary fittings like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc. welded or screwed joints as required including fixing the pipe.Make- Tata/Zindal/Sail
25 mm dia
80 mm dia
100 mm dia
Providing, fixing, testing & commissioning of single headed ISI marked oblique pattern hydrant/ landing valves with 80mm dia flanged inlet & 63 mm dia instantaneous type female outlet complete with stainless steel cap and GI chain twist release type plug and all accessories as per IS : 5290 -1983 (Type 'A') including fixing with anchor fasteners and flanged tapping .Make-Newage/Safex/Omex/Minimax.
Providing, fixing, testing & commissioning of 63 mm dia 15 m long non-percolating flexible hose (RRL- type B) as per IS : 636. Type "B" with Stainless Steel male & female instantaneous type coupling (IS 903) bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire.Make-KARTAR, Safex, Fireshield,Safe Guard
Providing, fixing, testing & commissioning of Standard Stainless Steel short size branch pipe with nozzle of 20 mm nominal bore outlet as per IS:903 suitable to fit with standard instantaneous type 63mm dia coupling ISI marked (IS:903) complete.Make-Newage/Safex/Omex/Minimax.
Standard Fireman's Axe with heavy insulated handle.
Providing, fixing, testing & commissioning of Weather proof standard fire hose cabinet (750 mm x 600 mm x 300 mm deep) made of 16 SWG powder coated M.S. sheet having single or double opening glazed.Make-Newage/Safex/Omex/Minimax.
Providing, fixing, testing & commissioning of Wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 30 Mtr. length x 20 mm dia heavy duty high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 6.5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe (heavy class) connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall by means of 120 mm x 100 mm long fasteners, bolts and nuts including painting.Make-Newage/Safex/Omex/Minimax.
Supply, installation, testing and commissioning of Fire Brigade inlet connection with provision for two male instantaneous coupling fabricated out of 100 mm dia. approved make heavy class MS pipe with non-return valve, Butterfly valve for fire fighting system including making connection by providing necessary piping & fittings to the fire storage tank, fire fighting wet riser, sprinkler system painting the same with 3 coats of enamel paint over a coat of Zinc Chromate primer all complete as per drawings, specifications. Make-Audco/Zoloto/Kirloskar/Leader
a) Two way
EXTINGUISHER Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire
Capacity 4.5 kg
Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire
Capacity 6 kg
Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets.
SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj
Illumination Glow light for Exit Indication with Battery Back-up. Make-Prolite/Bajaj
AUTOMATIC FIRE ALARM SYSTEM Manual Fire AlarmSystem-:Supply, installation, testing and commissioning of Conventional type Main Fire Alarm Control Panel (FACP), the panel shall be conventional type fire detection and alarm system with capacity of 2 zone complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character display complete accessories.Make- System sensor by Honeywell/Ravel/Bosch.
Supplying, installing, testing and commissioning of conventional type Manual call point with all accessories complete. The device Make-System sensor by Honeywell/Ravel/Bosch.
Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-System sensor by Honeywell/Ravel/Bosch..
Supplying, installing, testing and commissioning of 2C x 1.5 sq. mm, Twisted Pair PVC insulated FRLS unarmored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes of Acrylic Fire stop Sealant in the opening for cables passing through fire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating.
PUBLIC ANNOUNCEMENT SYSTEM Supplying and laying of 2X1.5 sq.mm PVC insulated PVC Sheathed FRLS copper cable with 20 mm dia medium class PVC conduit surface/ recessed conduit with all accessories as per direction of Engineer-in-charge. Make-Polycab/KEI/Finolex/Havells/RR Kabel
Supplying, installing, testing and commissioning of 12 Watt wall/celling mounted speaker completed as required.Make-Honeywell/Bose/Bosch.
Supplying and drawing of speaker cable Single pair, 2-core, 1.5 sqmm
Supplying, installing, testing and commissioning 2 zone voice alarm controller with USB mp3 am/fm player included 4 zone button paging station and microphone.Make-Honeywell/Bose/Bosch.
Supplying, installing, testing and commissioning of Power mixture amplifier of 480 watt.The amplifier should be clean reliable audio for public address amplification.Line input less than 1 volt, unbalanced& line output less than 1 volt unbalanced.Make-Honeywell/Bose/Bosch.
Novec 1230 System for Electrical Panels (Linear Pnuematic Heat Detection Tube 2.5 LB capacity Novec 1230/ FK5-1-12 , DLP Assembly with automatic valve, push in connector for tube, 2.5 LB PESO / DOT approved cylinder filled with Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation. MAKE: SUPREMEX/AMEREX/FIREBOUY/ FIRE SNIPPER
Linear pneumatic heat Detection Tube with all necessary fittings & supports.( UL LISTED) MAKE: SUPREMEX/AMEREX/FIREBOUY/ FIRE SNIPPER
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational . The control Panel should have provision for integration with fire Alarm /SCAD/BMS System. MAKE: SUPREMEX/AMEREX/FIREBOUY/ FIRE SNIPPER
Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn
Supply of Roof conductor holder for parapet- Polyamide conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn
Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn
Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn
Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn
Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn
Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn
Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn
SS Screw M10X50mm,(Non OBO Item)
PVC Sleeve,41mm (NON OBO Item)
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
Internal PH works Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge (Supreme/Ashirvad/Oriplast) GF Floor 20mm dia C-PVC pipe
25mm dia C-PVC pipe
1st Floor 20mm dia C-PVC pipe
25mm dia C-PVC pipe
Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) Ground Floor 25mm UPVC ASTM Pipe
32mm UPVC ASTM Pipe
32mm UPVC ASTM Pipe (1st Floor)
32mm UPVC ASTM Pipe (2nd Floor (Terrace)
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.G. Floor
1st Floor
Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge G.Floor
1st Floor
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in charge. G. Floor
1st Floor
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge 250mm to 375mm thick wall. G. Floor
1st Floor
Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge 15mm dia CP Bib cock (FLR-CHR-5047N Jaquar make)
15 mm dia CP Long body Bib cock(Jaquar)CON-CHR-049NKN
15mm dia CP angle stop cock (FLR-CHR-5053N Jaquar make)
15mm dia CP Pillar cock (FLR-chr-5011N Jaquar make)
15mm dia CP two in one bib cock (FLR-CHR-5041N Jaquar make)
15mm dia CP Health faucet (ALD-CHR-573 Jaquar make)
15mm dia CP Sink Cock (FLR- CHR- 5347 NJaquar make)
15mm dia CP concealed stop cock Cat no - CON.CHR 089 KN
Revolving Shower with arm Jaquar Cat NO--OHS-CHR-1985 + SHA-CHR-477
25mm dia brass or gun metal fullway valve(Leader / Kriti Make)
32mm dia brass or gun metal fullway valve(Leader / KritiMake)
40mm dia brass or gun metal fullway valve(Leader / Kriti Make)
15mm dia CP flange
15mm dia CP extension piece
Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 2000 litre capacity water storage Sintex tank (3layers) in 2nd floor.
Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge . 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hindware/Somany/Cera/Kerovit)
Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.110mm dia U-PVC SWR pipes(Supreme/Ashirvad/Oriplast)
100mm dia U-PVC 'P' trap
110mm dia U-PVC Door Tee
100mm dia U-PVC Plain Bend
100mm dia U-PVC Door Bend
75mm dia U-PVC SWR Pipe.
75mm dia U-PVC Door Bend.
75mm dia U-PVC Plain Bend.
110 UPVC Offset / without end
110mm dia Vent cowl.
PVC Clamp suitable for 75mm to 110mm dia pipe
125mm dia CP grating
Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge. 580mm size Orissa pan (Parryware / Hindware make )
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C. pan) of (Parryware/Hindware/Cera/Somany/Kerovit) with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge.EWC with 'S' trap plain with seat cover (Parryware/ Hindware/ Cera/ Somany/ Kerovit)
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. Under Counter Basin (560x455) (H)10095 white
Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge Design mirror(Parryware)
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge Glass shelf 600mm long(ACN-CHR-1171N)
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mm x 600mm long CP towel rail (Jaquar) ACN-CHR-1111SM
Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN)
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder AKP-ABR-35731P(Jaquar make)
Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet)
15mm dia urinal spreader
32mm dia C.P. dome waste
Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink With sink cock with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge 600x450x250 mm SS sink(With drain board -NIRALI)
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. toilet
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge .In ground floor
toilet 1x6.85x5.40x0.10
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. G.Floor
Ground Floor
First Floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. G. Floor
Ground Floor
First Floor
Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1"-6" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.
First Floor
Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in chargeKajaria / Somany of size 600 mm x 300 mm Kajaria - Duranmorfil or equivalent make . G. Floor Qntity same as plaster item above
Ground Floor
First Floor
Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. size 60 x 60 cm Kajaria / Fogparla or equvalent to be pree approved . G.Floor
Ground Floor
First Floor
Supplying all materials, labour, T&P and fixing Granite tiles in floor on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In ground floor
Ground Floor
First Floor
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In G.F
Ground Floor
First Floor
Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.G.F.
Ground Floor
First Floor
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.G.F.
Ground Floor
First Floor
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
Louvers 18x0.60x0.60=
EXTERNAL P.H. WORK. Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm all round concrete
160mm all round concrete
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mm X760mm x460mm
---- do --- addl depth of 0.15m upto 0.90m
Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Man hole chamber Inside size 910mmx910mmx910mm
---- do --- addl depth of 0.30m upto 4.50m depth
Cost of R.C.P.C.Cover.
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class Fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Brick masonry soakway pit 1.40m dia x 2.00m deep
Sinking of 200mmx150mm dia large Tube well(1No.)
Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore.
Labour for Drilling of 200 mm dia bore 0mtr to 120mtr
Labour for Drilling of 150 mm dia bore 0mtr to 120mtr
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
Lowering of 200 mm dia GI/P.V.C/MS casing pipes 0 mtr to 30 mtrs
Cost of 200 mm dia ASTM-D-1785/89 P.V.C schedule-80 pipe
Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge. By DTH
Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department).
Supplying all materials, labour , T&P for withdraing casing pipes from the unsuccesful borewell including all necessary equipment and labour as per direction of engeer in charge
Submerssible Pump Set 1 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm.
DOL control panel
2.50 sqmm cable
32mm dia steel short piece
32 mm dia HDPE Pipe
Bore Cap
C.I.Bracket
Rope Wire
Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site.
Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1:3:6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork in cement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber.
Construction 1 nos 100 users RCC Septic tank
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
1x9.90mx4x1.50m=
- do - with addl. Depth of 1.5 m
1x9.90mx4x0.95m=
Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
In ground floor 1x9.90mx4x0.15m=
Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
In ground floor 1x9.90mx4x0.15m=
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
(In ground floor) 1x8.90mx3x0.13m=
Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
For Roof slab
For RCC wall
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floor
6 mm thick Cement Plaster(1:4) to RCC surface finished smooth including closed deep chipping & slurry treatment (per one Sq. Mtr.)
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge.
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
Construction of 20000 Liters RCC Under ground Reserver of Inside size- 4.00 X 3.00 X2.00m Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department.
-do- with Ist additional depth of 1.50 m over the initial lead and lift
UGR - 1x5.90x4.90x0.70
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
UGR - 1x5.90x4.90x0.20
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
UGR - 1x4.70x3.70x0.10
Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete.
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.
RCC floor roof, chajja etc
RCC Beam, Column, wall etc
RCC Plinth bend/ Raft
Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
Providing fitting and fixing CI/MS step iron including fixing to wall etc. complete
Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_581442.xls
BOQ • 0.67 MB
dtcn01.pdf
Tender Documents • 2.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .