Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.9 LAccepted-AOC | 1 | Accepted-AOC Lowest Amount Quoted by MICRO TECH ENGINEERING Rs.789500.00 | |
| 2 | 2₹7.9 L+₹500 (0.06%)Rejected-Finance | 2 | Rejected-Finance Lowest Amount Quoted by MICRO TECH ENGINEERING Rs.789500.00 | |
| 3 | 3₹8.7 L+₹84,595 (10.7%)Rejected-Finance NO 5A SENTHIL ANDAVAR STREET DHANALAKSHMI COLONY EXTN VADAPALANI CHENNAI 600026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | 3 | Rejected-Finance Lowest Amount Quoted by MICRO TECH ENGINEERING Rs.789500.00 |
| Sl No | Description | Qty | Unit | NS ASSOCIATES L2 | MICRO TECH ENGINEERING L1 | Sba Infratech Services Private Limited L3 |
|---|---|---|---|---|---|---|
| 1.00 | Providing and fixing of Digitally Printed Retro Reflectorized Overhead Gantry Informatory sign Board made of cube corner Micro Prismatic grade sheeting conforming to Type XI standards of IRC67 - 2012 and ASTMD4956 – 09, specification and fixed over 2mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50mm x 50mm x 6mm. The Vertical support post for the installation of overhead sign Gantry shall be made of 300NB (Nominal Bore) MS Pipe with 12mm thick with a ground clearance of 6 meters along with 80NB (Nominal Bore) MS Pipe with 4mm thick and 40NB (Nominal Bore) MS Pipe with 3.20mm thick support posts. MS Base plate of size 1200mm x 1200mm x 25mm and MS Top plate of size 900mm x 1650mm x 16mm to be used to hold the sign board at the top and bottom respectively. MS Stiffener plates 8mm thick of sizes 420x420, 682x420, 288x288, 288x927 & 44x130 are to be used. Anchor bolts of dimension 25mm dia and 1000mm length are to be used as fixtures. The approved direction information should be digitally printed and should have 70% of the co-efficient of Retro-reflection values against the values as mentioned in Table 6.9 of IRC67 – 2012. The Latex printer used for digital printing should use inks with low VOC emissions and have green guard, eco logo certificates as per UL 2801 standards. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance and a certified copy of three years Outdoor exposure report shall be obtained as per IRC 67-2012 (As per MoRT&H specification No.801).Cantilever sign shall be installed at the site as per the approved structural and foundation drawing provided in the tender document and including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete. of size 12.00 m X 1.40 m | 1 | No | 7,90,000 ₹7,90,000 | 7,89,500 ₹7,89,500 Lowest | 8,74,095 ₹8,74,095 |
Tender Value
₹9.5 L
EMD Value
₹9,500
Closing Date
10 Sept 2025, 3:00 pmClosed
Executive Officer Thondamuthur Town Panchayat
Thondamuthur Town Panchayat, Thondamuthur, Coimbatore.
Providing and fixing of Digitally Printed Retro Reflectorized Overhead Gantry Informatory sign Board Mutthamizh Arignar Kalaignar M. Karunanidhi Centenary Celebration Commercial Complex at Ward no.07 in Thondamuthur Town Panchayat.
2025_DTP_600727_1
309-2/2025
Open Tender
Civil Works - Others
Works
365 days
Thondamuthur Town Panchayat
Class V and Above
2 documents required · 2 mandatory
₹0
₹9,500
30 Sept 2025
4 Sept 2025
10 Sept 2025
4 Sept 2025
10 Sept 2025
4 Sept 2025
Amount
Providing and fixing of Digitally Printed Retro Reflectorized Overhead Gantry Informatory sign Board made of cube corner Micro Prismatic grade sheeting conforming to Type XI standards of IRC67 - 2012 and ASTMD4956 – 09, specification and fixed over 2mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50mm x 50mm x 6mm. The Vertical support post for the installation of overhead sign Gantry shall be made of 300NB (Nominal Bore) MS Pipe with 12mm thick with a ground clearance of 6 meters along with 80NB (Nominal Bore) MS Pipe with 4mm thick and 40NB (Nominal Bore) MS Pipe with 3.20mm thick support posts. MS Base plate of size 1200mm x 1200mm x 25mm and MS Top plate of size 900mm x 1650mm x 16mm to be used to hold the sign board at the top and bottom respectively. MS Stiffener plates 8mm thick of sizes 420x420, 682x420, 288x288, 288x927 & 44x130 are to be used. Anchor bolts of dimension 25mm dia and 1000mm length are to be used as fixtures. The approved direction information should be digitally printed and should have 70% of the co-efficient of Retro-reflection values against the values as mentioned in Table 6.9 of IRC67 – 2012. The Latex printer used for digital printing should use inks with low VOC emissions and have green guard, eco logo certificates as per UL 2801 standards. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance and a certified copy of three years Outdoor exposure report shall be obtained as per IRC 67-2012 (As per MoRT&H specification No.801).Cantilever sign shall be installed at the site as per the approved structural and foundation drawing provided in the tender document and including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete. of size 12.00 m X 1.40 m
NS ASSOCIATES (BID ID -1454896)
Sba Infratech Services Private Limited (BID ID -1453206)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .