Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC A P NIMGAON DAKU TAL KARJAT DIST AHMEDNAGAR | KARJAT | AHMEDNAGAR | MAHARASHTRA | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹35.4 L+₹43,216.50 (1.24%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹38.6 L+₹3.6 L (10.4%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹39.2 L+₹4.2 L (12.1%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹42.4 L+₹7.4 L (21.2%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Prvision of certain sanctioned works at KK Ranges in the area of AGE B/R II under GE (N) Ahmednagar
2022_MES_510763_1
8598 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹80,000
Yes
5 Apr 2022
26 Feb 2022
25 Mar 2022
26 Feb 2022
23 Mar 2022
11 Mar 2022
60 days
Amount
Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement mortar plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.
Raking out joints/ pointing from stone walls, random rubble or polygonal rubble uncoursed or brought up to courses in cement mortar or cement lime mortar including existing paint/ cement base paint etc incl scrubing, washing the surface with water before plastering etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings etc complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge.
Excavation in trences n.exc 1.5m wide and n.exc 1.5m in depth for foundation soft/disintegrated rock and getting out etc complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore or gauge of broken stone n.exc 63mm, deposited spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge.
M&L for moorum filling in floors or paving laid in layers n.exc. 15cm thick spread levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling including spreading levelling, watering and well ramming in layers n.exc 25cm in disintegrated rock .layers n.exc 25cm etc complete all as specified and directed by Engineer-in-Charge.
Removing excavated disintegrated rock material n.exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation /mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate, 75mm thick in sub base for floor etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) type B-0 using 20mm graded stone aggregate , 40mm thick in floor finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
S&F Second class hardwood Plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or brads sectional area exc 13 but n exc 25 sqcm etc complete all as specified and directed by Engineer-in-Charge.
Rough finished wooden form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed by Engineer-in-Charge.
Rough finished wooden form work to sides of pillars, posts, struts, piers, columns and Stanchions etc complete all as specified and directed by Engineer-in-Charge.
Rough finished wooden Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge.
Rough finished Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) etc complete all as specified and directed by Engineer-in-Charge.
Rough finished Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-20 Design mix using graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-20 Design mix using graded stone aggregate as in Columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-20 Design mix using graded stone aggregate as in roof slabs, slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-20 Design mix using graded stone aggregate as in Chajjas etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-20 Design mix using graded stone aggregate as inBeams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-20 Design mix using graded stone aggregate as in Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; etc complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No 27 (here-in-before) but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge.
M & L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in surface channels and drain etc complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C-1 using 20mm graded mechanically crushed stone aggregates as in cills, steps, bands, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating including form work etc complete all as specified and directed by Engineer-in-Charge.
M & L for filleting in any position and to any shape, Section of fillet exc. 25 but n exc. 50Sqcm in cement and sand mortar (1:3) including all mitres, stops, etc complete all as specified and directed by Engineer-in-Charge.
S&F Steel ventilator with top hung shutter incl hinges, steel peg stay etc complete all as specified and directed by Engineer-in-Charge. Notes: 1. Guard bar shall be measured and paid separetly as S&F. 2. M&L for glazing shall be measured and paid separetly.
S&F for steel windows with side hung double shutters incl projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge. Notes: 1. Guard bar shall be measured and paid separetly as S&F. 2. M&L for glazing shall be measured and paid separetly.
Supply and fix 35mm thick second class hard wood plain framed factory made panelled shutters, two panel with lock rail and panel of 9mm BWP commercial ply. The size of rail and style as per IS 1003 (Part I) kiln seasoned and chemically pressured treated. etc complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel angle iron 50x50x6mm thick in chowkat of doors complete welding, fixing in position including hold fast of FI 25x3 mm and 300 mm long conforming to Fe 410-0 or Fe 310-0 etc complete all as specified and directed by Engineer-in-Charge.
M&L for 3.00 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge.
M&L for 2 mm mesh, Wire netting of galvanised steel wire 0.71 mm dia fixed with tinned tacks of wire staples etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy and fixed 300mm long etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix mild steel butt hinges medium weight cold rolled of size 100mm etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium anodised barrel tower bolt of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium anodised handles of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for coloured glazed ceramic tiles digitally printed premium series of size 300x450mm , 8-10 mm thick as approved by GE as in dado/skirting or on vertical surfaces, over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat grey cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Anti skid ceramic coloured tiles to match dado tiles makes as specified in PS,7-8 mm thick as approved by GE (square / rectangular) area of each tile 400x400mm, as in floor etc laid over and including screed bed 15 mm thick in cement and sand mortar (1:6) set and jointed with neat grey cemnet slurry and pointed with white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge.
M & L for 15 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-In-Charge.
M & L for 20 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and directed by Engineer-In-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stop cock cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge.
S&F fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing tubular towel rail, brass chromium plated 20 mm dia `D' type, 60 cm long between flanges including a pair of brackets etc complete all as specified and directed by Engineer-in-Charge.
M&L for cast iron floor trap with grating 75mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B1 using graded stone aggregate including removing old traps etc complete all as specified and directed by Engineer-in-Charge.
M&L for Grating doom 100mm dia of PTMT (Minimum weight 25gms) etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix wash hand basin vitreous China, ovel shape counter sunk/ counter top model of size 630x450 mm , CP waste coupling, 32 CP bottle trap and connecting to stop valve and nahani trap etc complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China urinals, Half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement and sand mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement and sand mortar (1:4); fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 32mm dia powder coated chromium plated curtain rods incl brackets etc complete all as specified and directed by Engineer-in-Charge.
S&F rotational molded polyethylene water storage tanks double layered (cylindrical vertical with closed top) of 500 litres capacity, triple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe, tank nipple and connected etc complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge.
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete Type C1 1:3:6 (20mm graded stone aggregate) set in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new steel surfaces of any description exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement and sand mortar (1:6) on any type of face of brick work or concrete surfaces and finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement and sand mortar (1:4) on any type of faces of brick work or concrete surfaces and finished even and smooth without using extra cement with WPC mixed at 2% of weight of cement used etc complete all as specified and directed by Engineer-in-Charge.
M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto course in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) pipes, single socketed, in any length, with rubber rings 75mm dia etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) pipe 75 mm bore single socketed in any length with rubber ring fixed to wall with approved solvent/adhesive etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing water proofing treatment on roofs, as per manufecturer's instructions and as specified after taking down/out as existing at site :- (a) Cleaning the newly plastered surfaces with wire brushes and applying a coat of bituminous primer @ 0.30 ltrs/sqmts and allow to dry. (b) Applying and laying torch APP polymer modified bituminous membrance 3 mm thick with non woven polyster matt as reinforced weighing not less than 3 kg/sqmts by thermofusion process as per manufacturers specification including applying one coat of aluminium paint. Make : Super Thermolay of STP / Equivalent in Dr Fixit, FosRoc. Note : (i) Work has to be carried out strictly by the authonticated applicator of the manufacturer and as per manufacturers specification as approved by GE. (ii) Certificate from manufacturer shall be submitted by the contractor.
Material and labour for rendering, 15 mm thick on stone/brick / concrete surfaces in cement and sand mortar (1:4) surfaces finished even and smooth without using extra cement, including WPC @ 3% of weight of cement etc complete all as specified and directed by Engineer-in-Charge.
M&L for prepainted Galvalume aluminium Zinc coating GI based corrugated steel sheeting Red colour 0.50 mm thick having tensile strength of 550 Mpa as in roof covering/Cladding fixed to the wall roof fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No 70 but plain sheets
S&F 10 user conventional On site RCC Hume pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, con-nection etc complete all as specified and directed by Engineer-in-Charge.
S&F 30 user conventional On site RCC Hume pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete glossy finish interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with gray cement and pigment laid over and including 30mm thick sand cushion etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick in Cement and sand mortar (1:4) over concrete surfaces finished even and smooth including water proofing compound as per manufacturers instructions etc complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid separetly as supply only.
M&L for 300 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars including cutting in to existing manhole and necessary making good of disturbed portion etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and appying three coats of white wash on wall etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and appying three coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface of walls and applying two coats of cement paint external surfaces etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparing New steel and iron work of any description and girth, not otherwise described, and treated with tar or coal tarblack paint etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new wood and wood based material of any description exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparing new plastered surfaces of wall and applying two coats of OBD over a 2mm thick layer of putty surface finished with roller finish on plastered surfaces of wall incl preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old plastered surface of wall and applying one coat of white lime wash etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old plastered surface of ceiling and applying one coat of white lime wash etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old plastered surface of wall and applying one coat of cement base paint etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old steel Surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directedMake of FRLSH Cable.Havells/Polycab/Finolex. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
All as per Item No 88 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board etc complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination two in one, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination 5 Amp / 16Amp, five in one, 5 / 15 Amp 230V AC etc complete all as specified and directed by Engineer-in-Charge
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs 8 way SPN, 415 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement double door Sheet metal enclosures factory made DBs 4 way SPN, 415 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge. Make Pholips Model Name Astra linne or equivalent make mentioned in list of makes in Appendix `C'
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 10 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge
Supply and fix exhaust fan,steel body AC Single phase,230 V of size 300 m sweep with ,blades and frame and louvers 450 mm sweep heavy duty etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specifiedand directed by Engineer-in-Charge Make -Havell's Cat Part: (ENDURAPEARLSL25W MP) ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent makes mentined in list of makes in Appendix `C'
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLSH stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-ChargeMake of FRLSH Cable.Havells/Polycab/Finolex Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :-
(a) LT cable10 Sqmm, 2 core.
Supply &lay HDPE pipe 40 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply and fix exhaust fan,steel body AC Single phase,230 V of size 300 mm sweep with ,blades and frame and louvers 300 mm sweep heavy duty etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing BLDC ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by Engineer-in-Charge.
Cutting cast iron / ductile iron pipes upto 80/50/25 mm dia for taking out branch connection up to 25 mm dia GI Pipe including inserting new CI/GI tee etc complete all as specified and as directed by Engineer-in-Charge including Exc & earth work
Supply and fix GI pipes, medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors etc for the 25 bore pipe complete all a s specified and as directed. Make:- Tata/Swastik/suryaprakash/Jindal
Material and labour in repairs gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for up to 25 mm bore GI pipe etc complete all as specified and directed by Engineer-in-Charge.
S& F in repairs high pressure brass valve with PVC ball suitale for fixing to GI pipe of 15 mm dia etc complete all as specified and directed by Engineer-in-Charge.
Avinash B Kullal
M/s IBEX Engineers and Contractors
M/s. A P INFRA
OM SAI ASSOCIATES
M/s AG PATHAN
MS. G.A. CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .