Lt Col Priyanka Tak GE I AF Shillong
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
REPAIR TO PACKAGE TYPE AC, SPLIT AC, COOLING
2023_MES_612501_4
8043/23/SHL
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE I AF SHILLONG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE I AF SHILLONG
₹24,000
Yes
19 Jan 2024
28 Nov 2023
3 Jan 2024
28 Nov 2023
1 Jan 2024
28 Nov 2023
Amount
Repair/maint of Split/Tower type Air Conditioners including disconnecting electrical connections, storing refrigerant gas in compressor of outdoor unit, splitting indoor and outdoor units, checking for faults and worn out parts/components, removing all accumulated dust and dirt of indoor and outdoor units, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling indoor and outdoor units, re-installing both indoor and outdoor units at respective locations (old or new locations as directed), re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required or connecting with service valves in outdoor unit and in indoor unit with threaded cast copper alloy sockets , making electrical connections, testing and commissioning complete all as directed for the following capacity Air Conditioners :- Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, thermal insulation, felts, lead metal balancing of blower fans, lugs, thimbles, sockets, and other minor materials shall be deemed to be inclusive in quoted rate. (b) leakage testing with nitrogen shall be deemed to be inclusive in quoted rate. (c) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against these items
(a) Split type Airconditioner 1.5 TR capacity of any make
(b) Split/Tower type Airconditioner 2.0 TR capacity of any make
(c) Split/Tower type Airconditioner 3.0 TR capacity of any make
Repair/maint of Package type Air Conditioners 16.5 TR including disconnecting electrical connections, storing refrigerant gas in compressor of outdoor unit, splitting indoor and outdoor units, checking for faults and worn out parts/components, removing all accumulated dust and dirt of indoor and outdoor units, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling indoor and outdoor units, re-installing both indoor and outdoor units at respective locations (old or new locations as directed), re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required or connecting with service valves in outdoor unit and in indoor unit with threaded cast copper alloy sockets , making electrical connections, testing and commissioning complete all as directed. Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, felts, lugs, thimbles, sockets and other minor materials shall be deemed to be inclusive in quoted rate. (b) leakage testing with nitrogen shall be deemed to be inclusive in quoted rate. (c) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against these items
Repair/maint of Deep freezers including disconnecting electrical connections, checking for faults and worn out parts/components, removing all accumulated dust and dirt, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassemblingdeep freezer, re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required or connecting with service valves with threaded cast copper alloy sockets , making electrical connections, testing and commissioning complete all as directed for the following capacity Deep Freezers :- Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, felts, lugs, thimbles, sockets and other minor materials shall be deemed to be inclusive in quoted rate. (b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against these items
(a) Deep Frezer of 200 Litre capacity of any make
(b) Deep Frezer of 400/425 Litre capacity of any make
Repair/maint of refrigerators including disconnecting electrical connections, checking for faults and worn out parts/components, removing all accumulated dust and dirt, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling refrigerators, re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required, making electrical connections, testing and commissioning complete all as directed for the following capacity Refrigerators :- Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, lugs, thimbles other minor materials shall be deemed to be inclusive in quoted rate. (b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against this item
(a) Refrigerators of 180 Litre to 310 Litre capacity of any make
Supply only following spare parts/components of ACs, Deep freezers, Refrigerators, Package type AC Units, refrigerant Gas for all these equipments/appliances complete all as directed :- Notes : (a) Genuine spare parts/components and refrigerant gas as originally fitted/filled in ACs, Deep freezers, Refrigerators, Package type AC Units shall only be provided during repairs/replacement. (b) These genuine spare parts/components and refrigerant gas shall be procured through OEM/their authorised distributers or dealers/service frenchise/service stations (Authosised to deal in genuine spare parts/components
Control circuit (PCB) for 1.5 TR capacity Split/Tower type AC, operating on 50 Hz electric supply of current rating, humidity control rating, operating temperature range and impedence as per Technical parameter of existing PCB installed by OEM in AC.
Control circuit (PCB) for 2.0 TR capacity Split/Tower type AC, operating on 50 Hz electric supply of current rating, humidity control rating, operating temperature range and impedence as per Technical parameter of existing PCB installed by OEM in AC.
Control circuit (PCB) for 3.0 TR capacity Split/Tower type AC, operating on 50 Hz electric supply of current rating, humidity control rating, operating temperature range and impedence as per Technical parameter of existing PCB installed by OEM in AC.
Remote circuit unit with remote controller cord, nylon fastner, tapping screw for 1.5 TR capacity Split/Tower AC as per Technical parameter of existing Remote circuit unit installed by OEM in AC.
Remote circuit unit with remote controller cord, nylon fastner, tapping screw for 2.0 TR capacity Split/Tower AC as per Technical parameter of existing Remote circuit unit installed by OEM in AC.
Copper tube of size 3/8 inch outer dia, 0.8mm thick ISI marked for Air conditioners.
Copper tube of size 5/8 inch outer dia, 1.0mm thick ISI marked for Air conditioners.
Standard strainer & capillary tube of compressor for 1.5 TR Split/Tower type A/C as per Technical parameter of existing strainer & capillary tube installed by OEM in AC.
Standard strainer & capillary tube of compressor for 2.0 TR Split/Tower type A/C as per Technical parameter of existing strainer & capillary tube installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 1.5 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 2.0 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 3.0 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 5.5 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC.
Hermatically sealed, uncut rotary type compressor for 200 Ltr capacity Deep Freezer as per Technical parameter of existing compressor installed by OEM in Deep Freezer.
Hermatically sealed, uncut rotary type compressor for 400/425 Ltr capacity Deep Freezer as per Technical parameter of existing compressor installed by OEM in Deep Freezer.
Hermatically sealed, uncut rotary type compressor for 180/195 Ltr capacity Refrigerator as per Technical parameter of existing compressor installed by OEM in refrigerator.
Hermatically sealed, uncut rotary type compressor for 310 Ltr capacity Refrigerator as per Technical parameter of existing compressor installed by OEM in refrigerator.
Referigent gas R-22.
Referigent gas R-407c.
Referigent gas R-134a.
Referigent gas R-32.
LCD/LED display unit for Split type AC of 1.0TR/1.5 TR/2.0 TR capacity.
Air equalizer for Split type AC of 1.5 TR/2.0 TR capacity.
Air equalizer for Split type AC of 3.0 TR capacity.
Swing motor of indoor unit of Split type AC 1.5/2.0 TR capacity as per Technical parameter of existing motor installed by OEM in ACs.
Indoor fan motor of Split type AC 1.5 to 3.0 TR capacity as per Technical parameter of existing motor installed by OEM in ACs.
Outdoor fan motor for 1.5 to 2.0 TR Capacity Split type AC as per Technical parameter of existing outdoor fan motor installed by OEM in ACs.
Outdoor fan motor for 3.0 TR Capacity Split type AC as per Technical parameter of existing outdoor fan motor installed by OEM in ACs.
Outdoor fan motor for 5.5 TR Capacity as per Technical parameter of existing outdoor fan motor installed by OEM in ACs.
Service Valve suitable for 5/8 inch outer dia copper tubing.
Service Valve suitable for 1/2 inch outer dia copper tubing.
Service Valve suitable for 3/8 inch outer dia copper tubing.
Service Valve suitable for 1/4 inch outer dia copper tubing.
Condensor Coil for outdoor unit of split AC 1.5 TR capacity as per Technical parameter of existing Condensor Coil installed by OEM in ACs. .
Condensor Coil for outdoor unit of split AC 2.0 TR capacity as per Technical parameter of existing Condensor Coil installed by OEM in ACs. .
Condensor Coil for outdoor unit of split AC 3.0 TR capacity as per Technical parameter of existing Condensor Coil installed by OEM in ACs. .
Overload protection relay for deep freezer of capacity 200 Ltr as per Technical parameter of relay installed by OEM in deep freezer .
Overload protection relay for deep freezer of capacity 400/500 Ltr as per Technical parameter of relay installed by OEM in deep freezer .
Cooling fan unit for deep freezer of capacity 200 Ltr as per Technical parameter of cooling fan unit installed by OEM in deep freezer.
Cooling fan unit for deep freezer of capacity 400/425 Ltr as per Technical parameter of cooling fan unit installed by OEM in deep freezer.
Thermostate switch for referigerator 180 to 310 ltrs capacity of reputed make.
Compressor relay for refrigerators of any capacity.
Bimetal thermostate for refrigerator for nofrost system
Thermal fuse for refrigerator for nofrost system
Timer for Refrigerator for nofrost system
LP/HP Switch for indoor unit of package type AC 16.5 TR capacity as per Technical parameter of existing LP/HP switch installed by OEM in ACs.
Contactor for 3 phase AC as per Technical parameter of existing Contactor installed by OEM in ACs.
Remote unit for 16.5 TR AC as per Technical parameter of existing remote unit installed by OEM in ACs.
Temperature sensor for 16.5 TR AC as per Technical parameter of existing temperature sensor installed by OEM in ACs.
Dryer for 16.5 TR AC as per Technical parameter of existing dryer installed by OEM in ACs.
Capacitor 40/50 mfd for AC as per Technical parameter of existing capacitor installed by OEM in ACs.
Capacitor 3/3.15/4 mfd for AC as per Technical parameter of existing capacitor installed by OEM in ACs.
Door rubber kit for refrigerators of any capacity.
Belt size 28A for blower motor package type AC.
Voltage stabilizer for AC's, Metal body with digital display, wall mounted, working voltage 160-285V (input) 200-240V (output), over and under voltage protection, auto start, low & high cut off complete all as specified and directed. Make : Microtek/ V-Guard
Supply and fix 4 sqmm 4 core FRLSH Cable with copper conductor PVC round sheathed (flexible) industrial cable, 1100 Volt complete all as specified. Make: Havells (ISI Marked) / Finolex (ISI Marked)/ RR Cable (ISI Marked)/ Polycab(ISI Marked) Note: Contractor shall produced original GST purchase voucher to the Engineer-In-Charge for future reference.
Supply and fix 2.5 sqmm 3 core FRLSH Cable with copper conductor PVC round sheathed (flexible) industrial cable, 1100 Volt complete all as specified. Make: Havells (ISI Marked) / Finolex (ISI Marked)/ RR Cable (ISI Marked)/ Polycab(ISI Marked) Note: Contractor shall produced original GST purchase voucher to the Engineer-In-Charge for future reference.
M/s Gupta Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .