Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.9 LAccepted-Finance | ₹9.9 L | L-1 | Accepted-Finance L-1 |
| 2 | L-2₹10.7 LRejected-Finance U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | ₹10.7 L | L-2 | Rejected-Finance L-2 |
| 3 | L-3₹11.5 LRejected-Finance | ₹11.5 L | L-3 | Rejected-Finance L-3 |
| 4 | L-4₹12.8 LRejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | ₹12.8 L | L-4 | Rejected-Finance L-4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹11.6 L
EMD Value
₹23,300
Closing Date
27 Mar 2026, 9:00 amClosed
EE(Elect.)/NZ
EE(Elect.)/NZ Division
Provision of AC, CCTV, Online UPS, water cooler and allied works at Community Hall, near Mange Ram Kothi for Ayushman Arogya Mandir in ward no. 2 Bankner, Narela Zone.
2026_MCD_272180_1
EE/Elect/NZ/2025-26/TC/56
Open Tender
Electrical Works
120 days
Narela Zone
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹23,300
9 Apr 2026
19 Mar 2026
27 Mar 2026
19 Mar 2026
27 Mar 2026
19 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C | 66 | Point | 1,064 | ₹70,224 |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | 26 | Point | 1,704 | ₹44,304 |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 96 | Meter | 311 | ₹29,856 |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X 4 sq. mm + 1 X 4 sq. mm earth wire | 63 | Meter | 373 | ₹23,499 |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X 6 sq. mm + 1 X 6 sq. mm earth wire | 46 | Meter | 482 | ₹22,172 |
| 6 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
(a) 1.5 TR with 5 Star BEE Rating | 3 | Each | 43,539 | ₹1,30,617 |
| 7 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. | 3 | Each | 807 | ₹2,421 |
| 8 | S/I/T/C of stand for split AC | 3 | Each | 788 | ₹2,364 |
| 9 | S/I/T/C of copper pipe for split AC | 30 | Metre | 838 | ₹25,140 |
| 10 | S/I/T/C of drain pipe | 30 | Metre | 106 | ₹3,180 |
stage.html
html • 0.05 MB
techsummary_317481.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tendernotice_2.pdf
PDF • 22.00 MB
BOQ_317481.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid