| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹26.3 L+₹41,962.10 (1.62%)Rejected-Finance | L2 | Rejected-Finance Awarded being 2nd Lowest Bidder | |
| 3 | L3₹27.9 L+₹2.0 L (7.72%)Rejected-Finance KOTHI NO 766 PHASE III MODEL TOWN BATHINDA PB | L3 | Rejected-Finance Awarded being 3rd Lowest Bidder | |
| 4 | L4₹29.3 L+₹3.4 L (13.1%)Rejected-Finance | L4 | Rejected-Finance Awarded being 4th Lowest Bidder | |
| 5 | L5₹31.4 L+₹5.5 L (21.2%)Rejected-Finance | L5 | Rejected-Finance Awarded being 5th Lowest Bidder |
Tender Value
₹46.6 L
EMD Value
₹93,200
Closing Date
15 Apr 2024, 6:00 pmClosed
Major S K Yadav GE(S) BATHINDA
GE(S) Bathinda Bathinda Mil Stn
GE(S) BTD TOKEN NO 89 OF 2023-24 PROVISION OF CERTAIN SPECIAL REPAIR AND MINOR WORKS UNDER AGE BR II AND AGE EM IV UNDER GE (SOUTH) BATHINDA AT BATHINDA MILITARY STATION
2024_MES_646921_1
GE(S)/BTD/TOKEN NO 89 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE(S) Bathinda
Class D
category a(i)
11 documents required · 11 mandatory
₹500
GE(S) Bathinda
₹93,200
Yes
28 May 2024
18 Mar 2024
17 Apr 2024
18 Mar 2024
15 Apr 2024
1 Apr 2024
Amount
Demantling of PCC (unrienforced) concrete of any description and in any positon otherwise specifically provided for and disposal off cebris, where directed complete all as specified and directe.
Pumping out water from the static water tank of any capacity and removal of water and mud from the base of SWT including solid material etc upto 50 mtrs distance complete all as specified and directe.
Use & waste of formwork to circular on plan with rough finished surfaces of concrete complete all as specified and directe.
S&F MS TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directe.
M&L for RCC M-30 design mix (using 20mm graded stone aggregate) as in Beams/bands on static tank wall and like complete all as specified and directe.
M&L for RCC M-30 design mix (using 20mm graded stone aggregate) as in static tank wall, retaining wall and basement and like of any thickness above top of footing complete all as specified and directe.
Taking down cement plaster including raking out joint hacking for key scrubing down with water etc complete all as specified and directe.
M&L for rendering 10mm thick in CM (1:4) on fair faces of brick work or cement concrete surfaces of wall including finishing the surface even and smoot without using extra cement including mixed with liquid watr pfoofing material @ 200ml per bag of cement complete all as specified and directe. NOTE : Supply only water proofing material shall be measured and paid separately.
Supply only water proofing material as per manufacturer's instruction complete all as specified and directe.
M&L for two coats of cement base paint on new plastered wall surfaces after applying a coat of alkali resistant primer including preparation of surfaces complete all as specified and directe.
M&L for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as in foundation filling, sub base and mass concrete including fnnishing the surface even and rough and including demolition of existing PCC and removing the debris not exceeding 50 metre etc complete all as specified and directe.
M&L for 100mm thick PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in hardstanding, plinth including finishing the surface even and smooth without using extra cement and including demolition of existing PCC and removing debris not exc 50mtr etc complete all as specified and directe.
M&L for Brick work sub class 'B' bricks, old size, straight or curved on plan exeeding 6 metre mean radious built in CM (1:6), including demolition of old brickwork of any type complete all as specified and directe.
S&F strutural steel work as in MS joist, chanel, angle, or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as directed conforming to Fe 290 Gde E-165 complete all as specified and directe.
Expanded metal, n.exc 4 Kg per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members incl dismantling of mild steel work of any description incl metal wire fabric of any thickness of mess fixed with steel frame weight n.exc 4 Kg per Sqm mild steel work etc complete all as specified and directe.
M&L for painting to new steel surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide or zinc chromium primer incl preparation of surfaces complete all as specified and directe.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410-W (Gde-E- 250) quality-A complete all as specified and as direcetd.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directe.
S&F tee Grid frame work made of GI sheet 0.30mm thick, bottom portion painted with cellular nitro painting consisting angle cleats of size 25mm wide 1.6m thick with flag fixed to RCC ceiling with door fasterner or wrapping the suspending wire around the existing wooden/steel/purlin/rafter for suspending grid frame work of size 605mm x 605mm c/c on main Tee and fixed to T-grid as per manufacturer's instructions. The section of main Tee 37mm x 24mm x 0.60mm and perimeter angle 24mm x 24mm x 0.50mm thick shall be fixed to wall with GI screws 40mm long and 450mm c/c along the perimeter of wall all as per manufacturer's instructions complete all as specified and directe.
M&L 12mm thick perforted particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber framework or with staples on snap grid, fixed in existing ceiling flat or sloping complete all as specified and directed
Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars etc., complete all as specified and directed.
Material and labour for 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces and finishing even & smooth but without using extra cement & with using integral water proofing compound complete all as specified and directed.
Dismantling of brick tiles or tertacing tiles single layer on roof & disposal of retrieved material up to distance n.exc 100m where directed, complete all as specified and directe.
Dismantling of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof disposal off rubbish upto a distance n.exc 100m where directed) complete all as specified and directe.
M&L screed bed or bedding layer of mortar 1:4 of 15mm thick as on roof surfaces parapet or vertical beam surface (horizental or vertical) of finish even and smooth witout using extra cement. Note using only course sand (Toka sand) in screed bed/plastering complete all as specified and directe.
Preparation of Roof / wall concrete/plastered surfaces & applied a coat of cold bituminous primer over cleaned surface @ 0.40 Kg/Sam followed by APP modified five layer polymeric membrane 3mm thick, minimum wt 3.50 Kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150 gms/Sam) manufactured by M/S STP Ltd/IWL India Ltd or its equivalent, laid as per the manufacturers instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required complete all as specified and directed.
M & L for cement concrete tiles 25cm x 25cm x 20 to 22 mm thick, m a c h i n e pressed; set jointed and pointed in neat cement slurry over and including 15mm thick screed in CM (1:4) with and including mixing of liquid water proofing compound as per manufacture specifications, as in roof and floor tiles complete all as specified and directed.
Surface excavation n.exc 30cm depth & average 15 cm deep & getting cut in soft/loose soil complete all as specified and directe.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directe.
M&L 25mm Sand filling under floors or in foundations including watering and consolidation complete all as specified and directe.
S&F Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directe.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directe.
Taking down old unserviceable rolling shutter of any size upto 25 Sqm area incl hood cover complete with all accessories and making good disturbed surfaces with CM 1:4 complete all as specified and directe.
S&F Steel rolling shutter without ball bearing as specified including top cover and 1 mm thick lath anchoring rod hasp and staple and gear operated type with bevel gear box and crank handle and one shop coat of primer erected in position as indicated complete gear operated type with bevel gear box and crank handle complete all as specified and directe.
S & F ball bearing suitable for new rolling shutters complete all as specified and directe.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directe.
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directe.
Rendering 15mm thick in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directe.
Carefully chipping, removing existing loose/ damaged concrete with plaster from Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade, making the edges straight and even and cleaning it by wire brush and then by air blower complete all as specified and directe.
Cleaning all existing reinforcement bars in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturer’s instructions, complete all as specified and directe. Note :- Mode of measurement : per sqm of breaking area of concrete only.
Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturer's instructions but min 0.4 kg/Sqm approx) in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 complete all as specified and directe. Note :- Mode of measurement: per sqm of application area of concrete.
Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and as directed by Engineer-in-charge. Make: Sika - SikaDur 32 LP/ Fosroc - Nitobond SBR (EP)/ Pidilite Dr Fixit Super Latex (EP) or equivalent make approved by E-in-Cs Br.
Rebuilding the section of structural damaged RCC/PCC elements of Roof, Ceiling, Chajja, Fascia, Fins, Drops repair to spalling concrete to its original size and shape in layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79 complete all as specified and directe.
PCC (1:3:6) type C-2 (using 40mm graded agg) 75mm thick as in plinth protection complete all as specified and directe.
M&L preparation of surfaces and applying two coat of white wash on prepared surfaces of wall etc complete all as specified and directe.
M&L preparation of surfaces and applying two coat of white wash on newly plastered surfaces of wall etc complete all as specified and directe.
M & L for preparation of undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint, complete all as specified and directe.
M&L Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directe.
M/L Providing, cement concrete in roof kerbs or mud stops, coving at juction of wall and chajja, parapet and wall rounded or chamfered on edges Type B-1 1:2:4 ( 20 mm graded aggregates) complete all as specified and directe.
M&L for 55mm avg thick PCC Padding in 1:2:4 20 mm garded aggreegate in roof slab finishing the surfaces evenand fair complete all as specified and directe.
Taking Down Chowkhats or Frame with Shutttter ( with out taking out shutter from the frame ) exc 1.50 sqm not exceeding 4.0 sqm each as doors , windows aaa& ventilators etc and removal from site complete all as specified and directe.
Supply and fixing Pressed steel frames of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified and directed.
M & L for PCC 1:3:6 type C1 (20mm graded stone aggregates) as in filling back of pressed steel door frames/chowkats and for fixing hold fasts, etc., complete all as specified and directed.
S&F 2nd class HW 35mm thick facotry made panelled shutters with lock rail and panel of 9 mm bwp commercial ply of 12 mm veneered particle board with commercial veneering on both faces . The size of rail and stylr as per IS-1003 (pt-I) klin seasoned and chemically pressure treated complete all as specified and directed.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 300 mm complete all as specified and directed.
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm complete all as specified and directed.
S & F 150 mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
M&L for preparation of old untreated or new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint on wooden surfaces complete all as specified and directed.
INTERNAL ELECTRIFICATION
Taking down carefully to existing serviceable copper point wiring (light,fan, socket or power) complete including fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, callbells etc removing materials to E/M store for keeping in safe custody and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
M & L for Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed.
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified and directed.
All as per Srl No. 63(here-in-befor) but for each additional light point on the same switch circuit complete all as specified and directed.
One Socket outlet three pin, 6 Amp, on the same board, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed.
One Socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed.
One Socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified and directed.
One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified and directed.
One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and directed.
Note for serial item No 61.00 to 69: 1. Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. 2. GI boxes shall be fixed flush in position with cement mortar (1:4) complete all as directed.
S&F Switch modular type single pole, one way, 6 Amp, one module complete all as specified and directed.
S&F Switch modular type single pole one way, 16 Amp, one module complete all as specified and directed.
S&F Socket outlet modular type, multipurpose, 3 pin, single pole one way, 6 Amp, two module, shutter type complete all as specified and directed.
S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6/16 Amp, two module, shutter type complete all as specified and directed.
S&F Socket outlet modular type multipurpose 3 pin, 2 in 1 single pole one way 6/16 Amp, two module, shutter type complete all as specified and directed.
S&F Fan regulator, modular type, 5 step, high speed, two module complete all as specified and directed.
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, 1.2 m 3000/6500K, efficacy not less than 90 lumen/watt, extruded Aluminium/ polycarbonate, PC diffusor and integrated inbuilt driver complete complete including making connection complete all as specified and directed.
S&F in repair rigid non metallic PVC conduit medium grade 20 mm nominal dia, 'ISI marked' inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddles, pipe hooks etc for telephone socket, complete all as specified and directed.
S&F in repair rigid non metallic PVC conduit medium grade 25 mm nominal dia, 'ISI marked' inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddles, pipe hooks etc for telephone socket, complete all as specified and directed.
S&F MCB 6-32 Amp 240V SP 10 KA ‘B’ series complete all as specified and directed.
S&F MCB 20-32 Amp 240V SPN 10 KA ‘C’ series complete all as specified and directed.
S&F RCBO for EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION 415 V 40-63A AC type 10kA Four pole 30mA ISI marked complete all as specified and directed.
S&F in replacement sheet metal encloser double door 4 way TPN 415V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
S&F in replacement sheet metal encloser double door 12 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
Dismantling and taking down carefully MCB distributing boxes including MCBs/isolators of any type and model complete all as specified and directed
S & F in replacement sub main two single core PVC copper conductor unsheathed wire multi standed 6.0sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, bend etc and including 6.0sqmm sopper conductor single core wire connected by common earth including 20mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed. (Note:- Two lengths of 6.0sqmm cable and one lenth of 6.0sqmm earth cable along with 20mm dia concealed PVC conduit, medium grade, ISI marked will be measured as one running length)
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S&F non metallic corrugated flexible PVC conduit medium grade 20 mm nominal size, 'ISI marked' inclusive of all fittings and all fixing accessories complete all as specified and directed.
Supplying and fixing in replacement 1100volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6sqmm complete all as specified and directed.
Supplying and fixing wall mounted LED batten fitting complete with one LED tubelight 1x20 watt, 6000K, 4 ft complete with decorative LED lighting fixture with extruded polycarbonate enviroment frindly, energy efficient complete with all light fittings connection complete all as specified and directed.
Supplying and fixing angle lamp holder polycarbonate type with back plate complete all as specified and directed.
Supplying and fixing LED 7W lamp base B-22 complete all as specified and directed.
Dismentaling of unserviceable earthing complete all as specified and directed.
Taking down serviceable/unserviceable ceiling fans 1200/1400mm sweep 230 V, AC, single phase from quarters, dismantling the ceilling fan and taking out complete rewinding (if unserviceable) the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws etc, refixing the repaired fan to respective qtrs complete all as specified and directed.
S & F ceiling fan 1200mm sweep, 5 star BLDC, minimum speed 350 RPM, min air delivery 210 CMM with service value 6.00 BEE corrosion resistant high performance with powder-coated set of 3 bldes, 100% copper motor, with set of 2 canopy, 1 down rod, 1 shackle assembly, 1 fan regulator capacitve type and accessories complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sqmm nominal cross section in service connections complete all as specified and directed.
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable.
S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 & IK 08 protection including fixing with suitable bolt and nuts complete with making connection complete all as specified and directed.
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
BALAJI CONSTRUCTIONS
M/S KARTIK BUILDERS
AABIA CONSTRUCTION
M/s Kamal Constructions
Ajay Enterprises
M/s HANS BROTHERS
SHARDA ENTERPRIES
Aman Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .