Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC 0001 000 KACHARI ROAD RAMAIPATTI MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | UTTAR PRADESH | 231001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.2 L+₹2.7 L (7.16%)Rejected-Finance 2 GA 29 HOUSING BOARD MANU MARG ALWAR 301001 | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance Being L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to incomplete/incorrect documents |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
12 Jan 2022, 6:00 pmClosed
GE Alwar
GE Alwar
CONVERSION OF TUBE LIGHT FITTING INTO LED FITTING AND OTHER SANCTIONED WORKS UNDER GE ALWAR
2021_MES_495716_1
8049/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹92,000
Yes
19 Feb 2022
17 Dec 2021
14 Jan 2022
17 Dec 2021
12 Jan 2022
30 Dec 2021
17 Dec 2021 - 29 Dec 2021
Amount
Taking down carefully tube light fitting, making good the disturbed surfaces of walls/ceilings and S&F decorative ultra slim liner, elegent and sleek designed LED T-5 Batten lighting fixture with extruded aluminium housing with frosted PMMA/PC diffuser, environmental friendly, energy efficient suitable for 20W with LED tube of model NAKSHATRA/20W and connecting up complete all as specified and directed. C&S Cat Part No LTTB4F20WLED/W or equivalent of Syska/Havell's/Crompton Greaves. Note : (a) Make shall be engraved on the body of the LED tube (permanent in nature). (b) Purchase date and warranty period shall also be permanently marked on the LED tube.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2KW capacity 25 Litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, Connection piece etc. including necessary fixing arrangement with 4 Nos of Anchor bolt of size 10mm dia 150mm long with washers complete all as specified and directed. Make :- Bajaj / Crompton Greaves / Usha Lexus / Venus / Racold.
M&L for sub main wiring with four runs of 4 sqmm (nominal area) size main cable & one run of 2.5 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cable, drawn through & including suitable size of heavy duty PVC conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete. Note:- 04 runs of 4 sqmm size, 01 run of 2.5 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose. Make of conduit : Finolex/Atlas/Kalinga/ Supreme/Bajaj Make of cable :Havells/RPG Cables/Polycab/ Plaza/Finolex/KEI
S&F metal clad plug and socket board SP&N enclousure with 2 Pole and earth metal plug and socket complete with 20 Amp MCB SP 'C' cureve complete all as specified.
M&L galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings.
S&F 15 mm bore bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F MCB Single Pole 240 Volts, 10 KA, ‘C’ Curve, 25 Amps complete all as specified. Make :- Legrand/L&T (Hagar) / Siemens (Beta Guard)
Dismantling and taking down old unserserviceable ACSR Conductor of any size from LT Poles and removing from site complete all as specified and directed..
Dismantling and taking down old unserserviceable GI Earth continuity wire, cradles etc of any size from LT Poles and removing from site complete all as specified and directed.
Dismantling and taking down old unserviceable cross -arms, bracing support clamps and back plates etc from LT Pole any size, complete all as specified and directed.
Dismantling and taking down old unserserviceable insulator any type and size from LT Poles and removing from site complete all as directed.
Excavation in trenches n. exc. 1.5Mtr width n.exc 1.5 Mtr in depth for laying of cables & foundation of poles, stay assembly and getting out soft/loose soil.
Returning filling in incl spreading levelling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified & directed by Engr-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified& directed by Engr-in-Charge.
S&F SMC street pole mounted juction box in PVC of Make Sintex made out of one piece totally enclosed,weather proof,frount openable ,water proof, having aluminium bus bars 100 Amp single phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300x200x100 mm fixing on pole with MS flat 25x3mm clamp including nut bolts front openable all as specified and directed by Engineer-in-Charge.
Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 Core cable laid in trenches/ducts/fixed on poles/walls/passing through pipe under road crossing/paths/drain /culverts etc all as specified and directed. Note : Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for separately.
Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core cable laid in trenches/ducts/fixed on poles/walls/passing through pipe under road crossing/paths/drain /culverts etc all as specified and directed. Note : Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for separately.
Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core cable laid in trenches/ducts/fixed on poles/walls/passing through pipe under road crossing/paths/drain /culverts etc all as specified and directed. Note : Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for separately.
Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core cable laid in trenches/ducts/fixed on poles/walls/passing through pipe under road crossing/paths/drain /culverts etc all as specified and directed. Note : Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for separately.
Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core cable laid in trenches/ducts/fixed on poles/walls/passing through pipe under road crossing/paths/drain /culverts etc all as specified and directed. Note : Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for separately.
Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core cable laid in trenches/ducts /fixed on poles/walls/ passing through pipe under road crossing/paths/ drain /culverts etc all as specified and directed. Note : Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for separately.
M&L for sand cushioning to PVC under ground cable 23cm thick (one layer of 8cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) and washed sand and punning to provide a required cover complete all as specified and directed. Note :- thickness after punning shall be considered for payment.
M&L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
M&L Galvanized steel tubing 100 mm bore light grade, ISI marked for protection of under ground cable on poles laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mm x 3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note : Excavation and earth work shall be measured & paid separately under respective items.
M&L Galvanized steel tubing 80mm bore light grade, ISI marked for protection of under ground cable on poles laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mm x 3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note : Excavation and earth work shall be measured & paid separately under respective items.
M&L Galvanized steel tubing 50mm bore light grade, ISI marked for protection of under ground cable on poles laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mm x 3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note : Excavation and earth work shall be measured & paid separately under respective items.
M&L Galvanized steel tubing 40mm bore light grade, ISI marked for protection of under ground cable on poles laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mm x 3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note : Excavation and earth work shall be measured & paid separately under respective items.
M&L for trenchless boring in any strata of soil across road, pavement, hardstanding etc by using modern ultra sound technology upto a depth as directed but not less than 0.60 mtr below GL/ road, pavement, hardstanding etc level for laying of LT cable under road, pavement, hardstanding etc without damaging existing under ground materials including provision of HDPE pipe of 80mm dia of 0.4mpa working pressure complete all as directed.
Supply, installing, testing and commissioning, factory made and tested Bus bar chamber outdoor type of size 60x45x45cm, made out of 3.15mm thick CRCA MS sheet and 50mmx50mmx8mm thick angle iron frame work, IP-65 class protection, powder coated finish over one coat of red oxide primer front & rear openable type, with locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys for each side opening} consisting of 04 Nos insulated copper bus bars 200 Amps rating on porcelain insulators. Bus bar chambers shall be mounted/fixed in ground/floor using 04 Nos angle iron of size 50mmx 50mm x 8mm welded/fixed to Bus bar chamber of height as directed including making post holes in ground and embedding angle iron in PCC 1:2:4 type B-1 complete all as specified and as directed. The Bus bar chamber shall following:- (a) MCCB 100 Amps four pole rupturing capacity 25 KA., 415 V AC , 50 Hz confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In adjustable short circuit setting 6 – 10 x In - 01 No. (b) Indicating lamps-01 set of three Notes (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed. (b) All the out going cable shall also be glanded and socketed. (c) Cost of glanding/socketing etc are deemed to be included in the unit rate of Bus bar chamber.
Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK) of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminium bus bars 1000 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x8mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & rear opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:- INCOMING (a) Aluminium bus bar of rating 1000 Amps for four pole incl PVC heat shrink sleeves (RYB &N) : 01 Set (b) MCCB four pole 250 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8-1.0 x In and adjustable short circuit setting 6-10 x In and rupturing capacity 36 KA at 415 V AC, 50 Hz complete - 01 No
Cont... OUTCOMING (a) MCCB four pole 100 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 04 Nos. (b) MCCB four pole 63 Amp confirming to IEC 60947-2 & IS – 13947-3 fixed type and rupturing capacity 16 KA at 415 V AC , 50 Hz complete - 01 Nos. (c ) MCCB four pole 40 Amp confirming to IEC 60947-2 & IS – 13947-3 fixed type and rupturing capacity 16 KA at 415 V AC , 50 Hz complete - 02 Nos. Control System (a) Amp meter (0-400A) analog type 96mm Square dial –01 No. (b) Volt meter (0-500V) analog type 96mm Square dial – 01 No (c) Three way rotary switch for volt meter/ammeter – 02 Nos (d) CT of ratio 400/5 – 01 Set of Three (e) Indication lamps R,Y,B ( LED type) with toggle switch - 01 Set.
Contd......... Notes (a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar. (b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed. (c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates.
S&F 2.5Sqm PVC insulated copper conductor three core including steel conduit fixed on pole (PCC/Steel Tubular) from street light box to street light fitting with clump nuts and bolts etc as directed by Engineer-in-Charge.
M&L for earthing complete as per electric plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 60x60cmx6.3mm thick burried directly in ground ( earth pit not less thanb 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised strip 32 x 6 mm earth lead by means of bolts, nuts, check nuts and wathers of GI or steel . Earthing strip shall be protected by galvanised iron pipe 40 mm bore light grade and connected to continous earth lead on pole/test point, Watering pipe shall be 20 mm bore GI medium grade. The unit rate quoted for earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover complete all as specified and directed.
B.S Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .