Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹51.4 L+₹2.2 L (4.55%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
15 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
ADDN/ ALTN/ IMPROVEMENT TO CAMERO MT AT AFCAO AND PROVN OF ALUMINIUM DOORS AT STILT AREA
2023_MES_618982_3
GE/SP/ TOKEN-54/2023-24
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹91,000
Yes
22 Dec 2023
24 Nov 2023
18 Dec 2023
24 Nov 2023
15 Dec 2023
2 Dec 2023
Amount
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed by Engr In Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed by Engr In Charge.
M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engr In Charge.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc and removing the debries outside the MOD land complete all as specified and as directed by Engr -in - Charge.
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M&L rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth with using extra cement complete all as specified and directed by Engr In Charge.
M & L rendering 10mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement complete all as specified and directed by Engr In Charge.
M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 3mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper with 3mm thick elastomeric wall care putty on walls, including repairing of pot holes and cracks with putty, take it plaster where it required complete all as specified and directed by Engr-in-Charge.
M&L for preparation on new or previously untreated wall surfaces and applying two coat of exterior Apex/weather coat over a coat of primer any tint (colour as approved by GE) over putty including preparation of surface of wall, band/chajja/balcony up to four storey height building complete all as specified and dircted by Engineer in charge.
M&L for preparation on old plastered or unplatered surfaces of walls and applying two coat of exterior Apex/weather coat over a coat of primer any tint (colour as approved by GE) over putty including preparation of surface of wall, band/chajja/balcony up to four storey height building complete all as specified and dircted by Engineer in charge.
M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling upto four stories complete and all as specified and directed by engr-in -charge.
M & L preparation of old plastered surface and applying two coats of white wash on ceiling complete and all as specified and directed by engr-in -charge.
M&L Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide/ zinc chromate complete all as specified and directed by Engr In Charge.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
M&L two coats of synthetic enamel paint including prepration of old wooden surfaces complete all as specified and directed by Engr In Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr In Charge.
S & F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; cooler stand, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engr In Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr In Charge.
All as per item No 19 above. But not exc 1.5 Sqm .
Providing and fixing factory made uPVC white colour sliding window three track made of extruded profile with wall thickness of 2.3mm (+/- 0.2mm). Window profile with hollow section with multi chamber, frame(88mmx52mm). sash (42mmx67mm). sliding mesh sase (42mmx567mm) sliding inlock (One vertical length in between two shutters) (45.5mmx28mm)Glazing bead (24.5mmx16mm) will be mitered cut and fusion welded to all corners & required wiremesh cloths, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware EPDM gasket + -0.2 mm thick galvanised steel frame (28mmx21.5mrn) sliding sash (30mmx18mm) 'sliding mesh sase (26mmx10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fastners. Hardware: [ touch lock of zinc alloyed (while powder coated) Corner strikers: Cyilnder. steelless steel wire cloths 0.36 mm nominal dia of wireand average dia of wire and average of widht of apreature 1.4mm and required accessories andglass) . The unit rate quoated by contractor includes cost of glass and includes all other connected accessories and making good with which is required in PCC/RCC/plaster. Net opening will be measured for payment purpose (A) Area exc. 2.00 sqm each complete all as specificed and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification complete all as specified and directed by Engr In Charge.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face complete all as specified and directed by Engr In Charge.
S&F 150mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete and specified and directed by engr-in -charge.
S&F 150mm long aluminium handle cast type polished bright complete and specified and directed by engr-in -charge.
S&F 100 mm long butt hinges medium weight, stenless steel, and fixed complete and specified and directed by engr-in -charge.
S & F in repair aluminium extruded section door closer hydraulically operated designation No-03, universal type, suitable for door shutters of 851 to 1000mm width and of weight of 61 to 80 Kg complete all as specified and directed by Engr In Charge.
S & F in repair 140mm long floor door stopper of Almn alloy body and tongue with hard drawn steel spring complete all as specified and directed by Engr In Charge.
M&L for guiniting work to RCC work in coloumn, chajjas, balconies, slabs, landings etc by removing loose, concrete, incl removing rust with short blasting and cleaning of surface with wire brush and applying epoxy treatment to rusted reinforcement and including S&F welded wire mess fabric or wire not less than 95x95x3mm adhesive plaster grade for concrete admixture and providing guniting pressure 2.00/2.50 Kg/Sq cm with admixture 1 part of cement and 3.50 part of sand and thickness 50mm average and making the surface even and smooth including necessary formwork and 10mm thick with CM 1:4 plaster over repaired surface with WPC complete all as specified and directed by Engr-in-Charge.
Demolition reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas, RCC Jali and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-Charge.
M & L for reinforced cement concrete M-25 using 20mm graded stone aggregate as in chajjas and the like complete all as specified and directed by Engr-In-Charge.
M&L RCC M-25 using 20 mm graded aggregate as in slab, shelves,washing/repair bay etc complete all as specified and directed by Engr-In-Charge.
M & L formwork to chullah hoods, chajjas, slab, trough and similar items including edges finished rough surfaces of concrete complete all as specified and directed by Engr-In-Charge.
S& F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia complete all as specified.
All as per item No 35 above but 6 to 8mm dia, as in stirrups, spacers and binders complete all as specified and directed by Engr In Charge.
Supply only liquid water proofing compound only complete all as specified and directed by Engr In Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.complete all as specified and directed by Engr In Charge.
M&L 100 mm thick cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes including demolition complete all as specified and directed by Engr In Charge.
M&L Glazed ceramic coloured tiles in vertical surface 300X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 complete all as specified and directed by Engr In Charge.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not xceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) & complete all as specified and directed by Engr In Charge.
All as per above item No-41 but as on vertical surface of wall such as skirting incl 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and directed by Engr In Charge.
M&L Vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor including vertical surface of wall such as skirting incl 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and as directed by Engr-In-Charge.
M&L for exterior (out door) wall tiles 350mX250mmX7 to 8mm or 350X 450X 7mm to 8mm thick on vertical surface, jointed in neat cement slurry and pointed in white or colour cement to match with tiles incl back plaster 10 mm thick in cm 1:4 with WPC complete all as specified and directed by Engr In Charge.
M&L for Chequered cement concrete coloured tiles (300 X300) 20-25mm thick confirming to IS -1237 (rubber moulded) in floor setc, set, jointed & pointed with cement slurry 15mm thick bedding layer of cement sand mortar (1:6) complete all as specified and directed by Engr In Charge.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
S&F precast machine pressed PCC interlocking paver block of 80 mm thickness, M-40 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved and including dismentling complete all as specified and directed by Engineer-in-Charge.
Taking out of APP modified water proofing membrane including mud puska complete on roof surface and surface properly cleaned by wire brush removing outside from MoD land complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. (e) Including 10mm thick rendering with 1:4 using WPC. (f) Painting with two coats of water proofing paint with aluminium finish. Note:- This treatement shall be done by the approved authorized applicators and guarantte of treatement shall be for 10 years.
M&L PCC 1:2:4 type B1 using 20mm graded aggregate mixed with water proofing compound as per manufacturer instructions laid as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement up to four stories complete all as specified.
M&L for cement concrete tiles 20cmX20CMX20MM thick wth grey cement and no pigment machine pressed; set jointed and pointed in neat cement slurry in floors and cut and polished completed all as specified and directed by Engr-In-Charge.
M & L 20 mm thick screed bed or bedding layer of cement mortar (1:4), for laying of cement tiles on roof complete all as specified and directed by Engr In Charge.
M&L for Providing, cement concrete type B-1 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, padding, rounded or chamfered on edges without using extra cement complete all as specified and directed by Engr In Charge.
Taking down steel tubing or removing from site of 15mm bore pipe all as specified and directed by Engineer-in-charge.
All as above item No 54 but 20mm bore.
S&F for 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
All as per item No 56 bove but 20mm bore
Dismantling water tanks exc 500 but not exc 1000 ltrs capasity and removing to store complete all as specified and directed by Engr In Charge.
S&F Rotational moulded polyethylene 1000 Ltr water storage tanks triple layers as per IS (cylindrical vertical with closed top) hoisted and fixed in position including necessary fittings complete all as specified and as directed by Engr-in-Charge.
S &F for 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe orr brass errule and fixed complete all as specified and directed by Engr In Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engr In Charge.
S&F for 75 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as percomplete all as complete all as specified and directed by Engr In Charge.
S&F for 110 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as per complete all as specified and directed by Engr In Charge.
S&F for PVC SWR bends 110 mm complete all as specified and directed by Engr In Charge.
S&F PVC SWR bends 75 mm complete all as specified and directed by Engr In Charge.
S&F for PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed by Engr In Charge.
All as per item No 66 above. But 75 mm dia..
S&F for PVC SWR Junction piece 75 mm provided with access door equal or unequal complete all as specified and directed by Engr In Charge.
S&F for 110 mm PVC SWR Junction single (Single T) provided with access door complete all as specified and directed by Engr In Charge.
S&F for PVC SWR vent cowl of size 110 mm complete all as specified and directed by Engr In Charge.
S&F for PVC SWR vent cowl of size 75 mm complete all as specified and directed by Engr In Charge.
S&F in repair vitreous china squatting pan “orrisa” pattern of size 580mmx440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) incl provision of cement concrete bedding, ‘P’ trap 100mm dia connection to trap , anti-syphonage complete all as specified and directed by Engineer-in-charge.
Supplying and fixing in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified.
S&F in repair PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia complete all as specified and directed by Engr In Charge.
S&F in repairs10 ltr capacity PVC flushing cistern coloured with accessories Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete and specified and directed by engr-in -charge.
S & F in repairs for 125mm dia Steelness steel grating doom with waste hole for waste pipe ( minimum weight 40 gram) complete all as specified and directed by Engr In Charge.
S&F in repair gun metal globe balve ot gate valve with mild steel iron wheel head, screwed both ends for iron pipe & fifed for 20 mm bore complete all as specified and directed by Engr In Charge.
S/F in repairs 15 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated with long shank and cup (concealed type)all as per specified and directed by Engr-in-Charge.
S & F in repairs 15mm CP bib tap fancy type copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe etc complete all as specified and directed by Engr In Charge.
M&L in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engr In Charge.
M & L in repairs for 15 mm dia Fancy type Chromium plated Angle valves, cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr In Charge.
S&F in repairs CP tubular Towel rail , 20 mm dia, D Type 600mm long between flanges brass chromium plated with screws and cleats, (Minimum weight 190 gms) complete all as specified and directed by Engr In Charge.
S&F in repairs soap dish, Stainless steel approximate size 160x160x90mm fixed to plugs with chromium plated brass screws etc complete all as specified and directed by Engr In Charge.
S&F of glass shelf consisting of 5.5 mm thick sheets glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engr In Charge.
S&F 15mm dia PVC Connection 450 mm long with nuts complete all as specified and directed by Engr In Charge.
S&F in repairs vitreous china wash hand basin of size 550mm x 400mm white, flat back including angle iron brackets with two coats of synthetic enamel paints including PVC waste pipe of 32mm dia of suitable length, CP fancy type pillar cock copper alloy swen neck, PVC connection of 15mm dia & 450mm long with PTMT nuts, and 32mm dia brass waste fitting complete all as specified.
Dismantling AC corrugated or semi corrugated sheets in roof covering (steel/AC/PVC any type) complete all as specified and as directed by Engr-in-Charge.
S&F pre painted galvalume aluminium zinc coating GI based corrugated/plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws as specification complete all as specified and directed by Engr In Charge.
S&F steel/work in tubular truses, purlins, rafters, struts, vertical members and similar work including special shape washers complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 grade St-240 complete all as specified and as directed by Engr-in-Charge.
M & L for 75 mm thick PCC 1:3:6 type C2 as in Plinth Protection using 40 mm stone aggregate including making joints & filling with sand bitumen mastic as per including dismentling complete all as specified and directed by Engr In Charge.
M & L 100 mm thick Cement concrete type B1 1:2:4 (20mm graded aggregate) and finished the surface even and smooth without using extra cement as in Floors and pavings, including making joints & filling with sand bitumen masticetc including dismentling all as specified and as directed.
M &l for removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 15km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed by Engineer-in-Charge.
M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls and including dismentling complete all as specified and directed by Engr-in-Charge.
M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete all as specified and as directed
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make of "'Ramco, Charminar/Armstrong'' at any height including dismantling complete all as specified and as directed by Engr-In-Charge.
S&F Modular partition workstation with 45mm thick with per-laminated top of 25mm thick as per color approved with metal powder coated legs, . Workstation having glass/fabric/white board prating on the top of the table, with three mobile pedestal, keyboard and CPU trolley. Overall size for per seat 2400x600x1200mm.(two seaters) In each workstation, 02 Nos power socket (5/15 AMPS) required for extension of PC/UPS connectivity complete. Model No ESC/WS/009. Make Royal Koas or equivalent.
S&F Modular partition workstation with 45mm thick with per-laminated top of 25mm thick as per color approved with metal powder coated legs, . Workstation having glass/fabric/white board prating on the top of the table, with three mobile pedestal, keyboard and CPU trolley. Overall size for per seat 1200x600x1200mm.(single seaters) In each workstation, 02 Nos power socket (5/15 AMPS) required for extension of PC/UPS connectivity complete. Model No ESC/WS/009. Make Royal Koas.
S & F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal aginst wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screw, pointing around urinal back in cement, fixing brackets, waste pipe with coupling, gratting and Union for discharge pipe.
M&L for providing PCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in manhole covers set in cement mortar 1:6 including necessary form works and moulds all as specified and directed by Engr-In-Charge.
M & L for anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engr-in- Charge.
M & L for anti termite treatment treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engr-in- Charge.
S&F steel rolling shutters thickness of lath 2.0mm with out ball bearing , as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer and erected in position , indicated complete :Push pull OR ManuaL type
S&F of Stainless Steel 304 series board of size 5'x3' written both side . Board Frame made of SS 304 series 16 gauge 25mm wide. The board shall be sheathed with 5mm thick ACP Sheet with reflective tape of blue color high intensity plastic (HIP) 3M on both side , letter shall be written in white color the size is 4" ht, as approved by Engr-in-Charge including necessory vertical SS post 304 series 50mm dia height of 7.5 ft and top mouth closed with SS cap including excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and nacessory Cement concrete in foundations, filling and mass concrete type C2 1:3:6 (40mm graded aggregate) complete all as specified and directed .
M&L for forming fair finishes drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/ stopped ends etc complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 (using 40mm graded agg) as in foudation filling and mass concrete as specified and directed by Engr-In-Charge.
M&L for PCC 1;2:4 type B-1 (using 20 mm greded crushed agg) as in coping, benching including weathering slightly rounded or chamfered angles as directed including necessary from work and finishing the exposed surfaces completed all as spcified and as directed.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power) complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling terminated in flush metal box alongwith outer cover plate for mounting modular switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size for one light/fan/bell point controlled by one switch. (a) one light point controlled by one SP switch
All as per item No-109 above but one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per item No-109 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No-109 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 109 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
S&F switch piano, flush type single pole, one way, 15 Amps, 240 volts all as specified and directed at site.
S&F socket outlet 5 pin 5 Amps all as specified and directed at site.
S&F socket 16 Amps, 2 in 1, flush type all as specified and directed at site.
Supply and fixing ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED lights fitting 1x 20W 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Taking down wall mounting fan of any size dismantling blades and removing fan and blades to and deposit to MES store
S&F wall mounting fan 450 mm sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
S&F Exhaust fan steel body AC single 300 mm sweep 230 Volt, 1400 RPM with louver including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to and deposit to MES store
Fixing only exhaust fan (M.D. supply) and connecting up including provision of cable from ceiling rose/connector to fan
S&F ceiling fan heavy duty 1200 mm sweep, 230 Volt including necessary fixing arrangement for proper fixing/hanging as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core comlete all as specified and as directed by Engineer-in-Charge.
M & L for submain wiring with two run of single core 6.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified. Note:- - 3 Runs of 6.0 Sqmm single core including one runs of PVC conduit shall be measured as one unit length.
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified. Note:- - 3 Runs of 4.0 Sqmm single core including one runs of PVC conduit shall be measured as one unit length.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. complete With all accessories all as specified and directed by engineer-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core
Supply and fixing 415V, 10KA, C curve TPN 16 to 32 Amp MCB current carrying capacity in DB complete with connection testing with commissioning complete all as specified and directed by Engr-in-charge.
Excavating in trenches, nexc 1.5m wide and n.exc 1.5m depth for fdn etc or for laying of pipe, foundation for poles, laying cable etc shafts n.exc 10 sqm on plan in any type of soil/rock complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge.
Removing excavated materials n.exc 50M and deposting where directed at a level n.exc 1.5M above the starting point complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning of cable provide with a layer of sand 8cm before laying the cable and 15cm depth after punning down and streching the cable complete all as specified and directed by Engr-in-charge.
S&L well burnt sub class B bricks old size as mechincal proteciton to underground cable laying across the cable complete all as specified and directed by Engr-in-charge.
S&F aluminium powder coated any colour (minimum thickness of powder coating 50 micron) for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
S&F powder coated aluminium door shutters, (minimum thickness of powder coating 50 micron) aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, powder coated aluminum snap beading screws etc. complete all as specified
S&F in repair aluminium deco grills confirming to DG-104 grade all as specified and directed by Engr-In-Charge.
S & F in repair aluminium extruded section door closer hydraulically operated designation No-03, universal type, suitable for door shutters of 851 to 1000mm width and of weight of 61 to 80 Kg complete all as s&d by Engr In Charge.
S & F in repair 140mm long floor door stopper of Almn alloy body and tongue with hard drawn steel spring complete all as specified and directed by Engr In Charge.
S&F Modular partition workstation with 45mm thick with per-laminated top of 25mm thick as per color approved with metal powder coated legs, . Workstation having glass/fabric/white board prating on the top of the table, with three mobile pedestal, keyboard and CPU trolley. Overall size for per seat 1200x600x1200mm.(single seaters) In each workstation. Model No ESC/WS/011 make Royal Koas and equivalent.
shakti construction
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .