Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L2₹31.6 L+₹5.2 L (19.8%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹34.5 L+₹8.1 L (30.6%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹35.0 L+₹8.6 L (32.4%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN THE LOWEST BIDDER |
Tender Value
₹36.7 L
EMD Value
₹73,360
Closing Date
27 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE BHOPAL
HQ CWE BHOPAL, SI LINES, BHOPAL, PIN-462001
SPL REPAIR TO MD ACCN NO P-325 (01 TO 04) AND P-326 (01 TO 04) (TYPE-II) AT CTO COLONY BAIRAGARH, BHOPAL
2020_MES_352074_1
83521
Open Tender
Civil Works
Item Rate
180 days
BHOPAL
AS PER NIT CONDITIONS
4 documents required · 4 mandatory
₹500
GE BHOPAL
₹73,360
Yes
27 Aug 2020
24 Jun 2020
3 Aug 2020
24 Jun 2020
27 Jul 2020
15 Jul 2020
60 days
Amount
Taking down chowkhats or frame with shutters n.exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed
Taking down chowkhats or frame with shutters exc 1.5 Sqm but not exc. 4.00 Sqm each (without taking off shutters from the frame) complete all as specified and directed
S&F in factory made Window ECO 4000, of double rebate openable/fixed window made of galvanised steel colour coated/powder coated (base steel as per IS 513 Of 'D' quality, galvanised as per IS 277 with zinc of 120 gms/sqm) with total thickness of coating 0.58 microns thick and back coated with alkyd backer 5-7 micron thick or powder coated with pure polyster powder up to 50-60 micron thick. Outer frame section 72 x 55 mm, center mullion section 72 x 50 mm, shutter section 47 x 20 mm, flymesh section 40 x 20 mm and the fixed glass beading section 12 x 12 mm, outer frame and mullions shall consist rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the section cut to length mitre joined with corner bracket, center millions fised with mullions cap, stay, handle, latch, 2 nos of heavy duty stainless steel pivot hinges per shutter and paneled with 5 mm thick plain float glass and S. S. mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propyelene Diamine Monomer) gaskets including fixing windows in the Concrete/Masonary wallby means of self expanding screw, including 10 mm Square bars welded to 6 x 12 mm flat at a distance 150mm C/C (Pitch) etc complete as oer direction of Engineer-in-Charge. Make: NCL Alltek and seccolor LTD or equivalent factory made as approved by CWE. Details of specification of company is also enclosed.
S & F Solid PVC door frame of size 50 mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and fixing in opening as per manufacturer instruction complete all as specified and directed.
S&F 105X60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified made out of 1.25mm thick MS Sheet complete all as specified and as directed.
S&F 125X60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc complete as specified made out of 1.25mm thick MS Sheet complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F 35 mm thick flush shutters, solid core construction, with partical board core and plywood face panels , commercial type on both side complete all as specified.
M&L for cement concrete 1:2:4 Type B-0 (using 12.5mm graded crushed stone aggregate) as in filling of door frames of pressed steel and in bed blocks and like etc complete all as specified and as directed.
S&F factory made 35 mm thick, 2nd class hardwood glazed and skeleton shutters, open rebated and preparaed to receive glass, gauze, etc. (without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitread beads for securing glass, etc; sizes of members of shutters as specified in SSR Part I, section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples fixed complete all as specified and directed..
S&F IInd class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints and fixed complete all as specified and directed.
M&L in repairs 18/19mm thick Prelaminated particle board, interior grade,prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws/nails to timber frame work including taking down old board complete all as specified and directed.
S&F 30mm Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed.
M&L for 6mm thick lipping for external teak wood on veneered particle board or block board fixed with nails complete all as specified and directed.
S&F 100mm hasp and staple, safety type, anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed
S&F 40mm dia cupboard knobs fixed with nuts, screw and washer of MS, bright finished
S&F 100 mm mild steel butt hinges medium weight,cold rolled complete all as specified and directed
S&F 150 mm Aluminium handles, cast type, anodised complete all as specified and directed
S&F 100 mm Aluminium handles, cast type, anodised complete all as specified and directed
S&F 200 mm Aluminium anodised barrel tower bolts extruded section and fixed complete all as specified and directed
S&F 150 mm Aluminium anodised barrel tower bolts extruded section and fixed complete all as specified and directed
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed
M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F in repairs 25mm dia curtain rails, mild steel, chromium plated with fixing brackets, stop rollers etc complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for granite (any type) 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, counter, shelves and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed in CM 1:4 complete all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, beams,chajjas and similar work not exceeding 200 mm thick (Horizontal/ Sloping) receive for fair finished surfaces complete all as specified and directed.
M&L for Mild steel TMT Bar 6 to 8mm dia cut to length , bent to shape to required , including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild seel wire ( annealed ) not less than 0.9mm dia or securing with clips quality confirming all as specifed and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4 Type B1 (using 20mm graded crushed stone aggregate) on as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajjas and the like complete all as specified and directed.
Demolition of cement concrete in ground floor, (unreinforced) paving nexc 15 cm thick(below or above GL) incl tiling if any complete all as specified and directed
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection, aprons, hard standing, path and like including finishing the surfaces even and smooth without using extra cement complete all as specified and directed
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling, subbase and mass concrete complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4, type B-1 (Using 20 mm graded crushed stone aggregate) for sub base of floor, complete all as specified and directed
M&L for non skid ceramic coloured tiles 7mm to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 Sqm, but not exceeding 0.18 Sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified & directed
M&L for non skid ceramic coloured tiles 7mm to 8 mm thick(square/rectangular) area of each tile exceeding 0 .11 Sqm, but not exceeding 0.18 Sqm on vertical surfaces such as skirting, dado and risers to steps etc over & including 10 mm thick rendering in CM 1:4 set & jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified & directed.
M&L for chequered cement concrete tiles glossy finish size( 20 cm x 20cm x 25mm thick set jointed and pointed in neat cement slurry with grey cement and pigment over 15mm thick screed bed in CM 1:6 complete all as specifed.
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles and rubbish off the permises complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7 mm/ 450X350X7mm thick set and jointed over and including 10 mm thick rendering even and rough in CM1:4 for backing of tiles, jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
Demolition of brick work, built in Cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with sub class ‘B’ (modular size bricks) straight or curved on plan exc 6 m mean radius, built in cm 1:6 all as specified and directed.
M&L for brick work with sub class ‘B’ (modular size bricks) straight or curved on plan any radius in half brick thick walls, built in CM 1:4 all as specified and directed.
Taking down cement plaster on brick or concrete surfaces, including raking out joint, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on brick/concrete surfaces including finishing the surfaces even and smooth (without using extra cement) complete all as specified and directed
M&L for 15mm thick rendering in CM 1:4 on brick/concrete/stone masonary surfaces including finishing the surfaces even and smooth (without using extra cement) including complete removal of entire existing treatment and washing complete all as specified and directed by Engr-In-Charge
M&L for 10mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling including finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of cement based putty complete all as specified and as directed. Note: Putty shall be measured and paid for seperately under respective item & thicknes of putty will be as per manufacturer instructions
M&L for complete removal of existing treatment from walls and applying two coats of oil bound distemper over a coat of cement based putty complete all as specified and as directed. Note: Putty shall be measured and paid seperately under respective item & thicknes of putty will be as per manufacturer instructions
M&L for applying one coat of 3mm thick white wall care putty on walls complete all as specified and directed. Make- Birla / JK putty or equivalent as approved by the GE. Note: Putty shall be measured and paid for seperately under respective item & thicknes of putty will be as per manufacturer instructions:
M&L for preparation and applying two coats of Cement base paint over a coat of primer complete all as specified and as directed.
M&L for complete removal of existing treatment from walls and applying two coats of Cement base paint, complete all as specified and as directed.
M&L for preparation of newly plastered or unplastered surface of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for complete removal of existing treatment from ceiling and applying three coats of white wash complete all as specified and as directed.
Taking down existing old roof treatment of any description , any type including removal old Tar felt, screed bed and plastering etc complete all as specified and directed.
M&L for provn of water proofing roof treatment to accessible/Non accessible RCC roof with APP modified membrane with non woven polyster reinforced wt not less than 3 Kg/Sqm of thickness not less than 3 mm having thermal; insulation with white mineral/ gravel finish on upper side of membrane uniformly embedded during manufacturing process. All as per following specifications:
Conduct ponding test for 72 hrs ,after ponding test grouting is to be done as per item no. 54 at the leakage area
After the surface is repaired with pressure grouting the slab will be tested for watertightness against before processing further treatments.
10 mm thick plaster in CM 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab.
The surface of the roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the grove shall be cut around to tuck in the treatment as pipes, chimneystacs etc. and other similar situations to ease up about corners.
Bituminous primer conforming to IS : 3384-1965 @ 0.30 Kg/Sqm to be applied an prepared surface till the surface is properly impregnated.
3 mm APP modified water proofing membrane as specified shall be laid on the primer surface by torch application method as per manufacturers instructions, The overlaps while torching shall be 100 mm in both directions (longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer.
All joints & changes in direction should be curved with cement morar 1:3 mixed with SBR latex @ 200 ml per bag of cement and cured well before laying the membrane.
A fillet of PCC (1:2:4) type B-0 of 100 mm wide and 100 mm height in rounded / triangular shape shall be provided at all junctions of vertical and horizontal surfaces and whereever there is a change of direction. The membrane should not be taken over at any steep turns and hence all corners/ junctions should be rounded.
72 hrs testing of treatment for water tightness by ponding of water.
S&F in repairs sink made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 mm x 420 mm with bowl size 410 mm x 330 mm x 160 mm including waste coupling and waste pipe complete all as specified and directed.
S&F in repairs syphonic action type PVC low level flushing cistern 10 ltrs capacity incl 32mm dia flush pipe and fixing to supply pipe including PVC connection 600 mm long 15 mm bore with brass heads & washers with connections fixed in repairs complete all as specified and directed.
S&F in repairs 15 mm bore stop cock,(angle valve) cast copper alloy, fancy type, chromium plated, screwed down, high pre-ssure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs 15 mm bore Bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrulle and fixed complete all as specified and directed.
S&F in repairs 15 mm bore stop cock, cast copper alloy, chromium plated with long shank and cut (concealed type), screwed down, screwed for iron pipe or union complete as specified and directed.
S&F in repairs brass chromium plated shower rose 125 mm in size with or without swivel joints any size incl fixing to steel pipe or union, complete all as specified and directed.
S&F in repairs vitreous china wash basin,white flat back size 550X400mm including CP waste coupling, PVC waste pipe and brackets fixing in position complete all as specified and directed
S&F in repairs 15 mm pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified & directed
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
Taking up or down 20 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 20 mm GI tube medium grade with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Taking up or down 15 mm bore GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15 mm GI tube medium grade with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F in repairs 32mm bore PVC waste pipe for WHB/ kitchen sink complete all as specified and directed.
S&F in repairs vitreous china squatting pan "Orissa Pattern" size 580mm x 440mm white with integral foot rests, including prov of cement concrete bedding and 'P' or 'S' trap as required complete all as specified and directed.
S&F in repair 100mm dia CP grating complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with excavated soil of any type including spreading,leveling, watering and well ramming in layers n exc 25 cm thick.
Removing excavated material exc 250 m and not exc 500 mtr and depositing where directed complete all as specified and directed by Engr-In-Charge.
M&L for precast cement concrete Type B1 1:2:4 (Using 20mm graded crushed stone aggregate) as in landings, cover slabs, precast man hole covers, set in CM 1:6 complete all as specified and directed.
Demolition and breaking up of 150 mm dia of drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L for 150mm bore salt glazed stone ware drain pipes laid in trenches and jointed as specified and directed.
M&L for cement concrete 1:4:8 type D2 (Using 40 mm graded crushed stone aggregate), concrete bed to drain pipes 150 mm dia including packing under, and haunching against the sides of pipes after they are laid and tested; complete all as specified.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls/ laid in trenches/floors complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls / laid in trenches/floors complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 110 mm dia all as specified and directed.
S&F in repair PVC (SWR) bends any radius 75 mm dia all as specified and directed.
S&F in repair 75mm dia PVC (SWR) floor/ Nahani trap with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) vent cowl.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for concealed point wiring for light point with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories(PVC Casing and caping to be done wherever wiring to be run on ceilings and concrete surfaces including one run of 1.5 sqmm FRLS muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface , including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note: Wiring to be done as per arroved colour code in IE rule.Rate includes chase cutting for concealed wiring Make of Cable: Polycab/ L&T/ Havells
Ditto all as per item No. 90 here-in-before but for one fan Point controlled by one way switches, with cables 1.5 sqmm complete all as specified and directed.
Ditto all as per item No. 90 here-in-before but for one bell Point controlled by one bell switches, with cables 1.5 sqmm complete all as specified and directed.
Ditto all as per item No. 90 here-in-before, but for exhaust fan point controlled by one push button on same board with other switches or independent with cable 1.5 Sqmm. complete all as specified and directed.
Ditto all as per item No. 90 here-in-before but for one light point controlled by two 2 way switches, with cables 1.5 sqmm complete all as specified and directed.
Ditto all as per item No. 90 here-in-before but for 3 pin socket outlet, 5 Amp on the same board with other switches, complete all as specified and directed.
Ditto all as per item No. 90 here-in-before, but for 3 pin 5 amp switch socket combination on independent board with other switch complete all as specified and directed.
Ditto all as per item No. 90 here-in-before but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
Ditto all as per item No. 90 here-in-before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for Sub main wiring with two single core FRLS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in non metallic rigid PVC conduit of size 25 mm dia ISI marked including PVC insulated unsheathed 2 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete.
Taking down u/s light fitting any type and S&F LED 20 W/21Watt tube light fitting (T8 type) , including LED retrofit tube 20/21 W one side connection type, 240 v, PF > 0.90, colour Temp 6500 K, System Luminous efficiency > 100Lm/W, complete with powder coated CRCA decorative patti suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make:- Bajaj (For Batten Model No. BLRB DB 118 or suitable for mounting T8 LED tube 20 watt and For LED tube Moldel No. BLRB21WCWC) or C&S cat Part No. LTDC01220WLED/WD (LED battan T8 TARA -M) or Havells (Titania LED tube with Regal batten LED) or equivalent in Philips/ Crompton as approved by GE.
S&F Polycarbonate switch piano, flush button, single pole, one way 5 Amp , 240 volts ISI marked, Make: Anchor/ Havells/Cona/ Leader (white colur)
&F Polycarbonate switch piano, flush button, single pole, two way 5 Amp , 240 volts ISI marked, Make: Anchor/ Havells/Cona/ Leader (white colur).
Supply and fixing, Polycarbonate ceiling rose, surface type, 3 terminal, 240 , ISI marked, Make: Anchor/Havells/ Cona/ Leader (white colur)
Supply and fixing Polycarbonate socket outlet 2-in-1, 5 pin 5 Amps, 240 volts, flush type Make: Anchor/Havells/ Cona/ Leader (white colur)
S&F with socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete as directed.
S&F Polycarbonate switch piano flush button single pole one way 15 Amp 240 volt ISI marked, Make: Anchor/Havells/ Cona/ Leader (white colur)
S&F, stepped type electronic fan regulator, Delux model, 100 watt, 240V, flush type. Make: Anchor/ Havells/Cona/ Leader (white colur)
S & F Lamp holder, insulated body with back plate suitable for batten/angular fittings fixed complete. Make: Anchor/Havells/ Cona/ Leader (white colur) with LED lamp of 9 watt (of make: Philips/ Bajaj/ CG)
S&F Buzzer, Ding Dong AC. 230 volts, single pole. Make: Anchor/ Havells/Cona/ Leader
S&F Polycarbonate bell push flush type, SP, 5 amp, 240V, Make: Anchor/ Havells/Cona/ Leader (white colur)
Taking down main switches/ MCB DBs of any capacity/ type including MCBs.
Supply and fixing double door MCB DB,VTPN, 4 way, 440 volts grade, with 200 amps rated bus bar with MCB as incommer and MCB as outgoing.complete fitted on wooden board first class of suitable size complete all as specified and directed by EIC : Make- Legrand/ L&T/C&S.
Supply and fixing, flush to wall, double door MCB DB, SPN 12 way, 240 volts grade, with 200 amps rated bus bar. of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete fitted on wooden board first class of suitable size complete all as specified and directed by EIC : Make- Legrand/ L&T/C&S
S&F MCB SPN 5 to 40 amps 10 KA, C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge. Make- Legrand/ L&T/C&S
S&F MCB SP 240 volts 5 to 40 Amps, 10 KA breaking capacity, 'c' curve including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge. Make- Legrand/ L&T/ C&S
S&F MCB TPN 63 Amps 10 KA including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge. Make- Legrand/ L&T/ C&S
Taking down existing u/s ceiling fans and S & F Ceiling fan of AC single phase 230/240 V of size 1200 mm sweep and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed by Engr-In - Charge. Make: Crompton/Bajaj/Havells. Note: Old ceiling fans to be deposited in AGE E/M Yard.
Taking down old unserviceable sub main wiring of any size and any discription all as directed by Engr-In-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed. Note: Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM)
Material and labour for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to end or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed.
M&L for taking down existing u/s KWH meter and S&F Single phase digital KWH meter poly carbonate body 5-30A in position by providing wooden board of first quaility, of size 250 mm x 350 mm, with making electric connection complete all as directed and specified by EIC. Note: Old existing u/s KWH meter to be deposited to AGE E/M Bairagarh.
S&F LED bulk head luminare weather proof of including 10 watt LED lamp and connecting with copper flexible two core 23/0.0076 and all necessary fittings complete. Make: Bajaj cat Part No. BIBWP10W LED (112334) or equivalent as approved by the GE.
Taking down existing u/s fitting and S&F LED 9/10 Watt tube light fitting, surface mounting fitting for mirror light with slik and light weight batton, 240 Volt, with PF >0.95, efficiency >95 , colour temp 6500K complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make:- Havells cat Part No. LHEXBQP7PN1W009 or equivalent in Philips/ Crompton/ Bajaj and C&S as approved by GE.
S&F exhaust fan 300 mm sweep complete with louvers including all civil work like cutting and making circular opening in existing wall of kitchen etc, including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make: CG or equivalent as approved by the GE.
Supply, fixing verticle storage water heater (Geyser), 240V, AC, Single phase, 50 Hz of 25 ltrs capacity, with heating element of 2.0 KW, stainless steel tank, 5 star rating, with indicator lamps for thermostat operation, with max rated pressure 8 bar, fixing to wall by means of dash fashner of min 80 mm long ( Vertical wall mounting), including S&F, connecting with cold and hot water pipe lines, heavy grade, of size 15 mm x 450 mm length with rubber washer , making complete connection and testing of geyser for its staisfactory functioning. Make of Geyser: Bajaj, Model: Shakti 25 L GPV cat No. 150747 or equivalent in Racold (Model No. Altro 2 25 V/H) / Havells.
S&F single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V, complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top, complete all as specified and as directed. Make: Legrand cat part No. 607841 or equivalent in Schneider/ L&T.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point.
Sand cushioning/ sand covering for underground cable protection complete all as specified. Note: Punned thickness shall be measured & paid.
Brick Sub Class 'B' locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified.
Supply and Laying XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 4 x16 sqmm, laid in trenches/floor or fixed on wall/pole complete all as specified. Make of cable: Havells / Polycab/ KEI
Taking out existing u/s pipe and S&F GI Tubes, 'light grade' galvanised 50 mm bore, with all fitting and laid in floors, under road, pavement or hard standing, along pole steel tubing for protection of UG cable all as specified and directed by EIC.
M&L for cutting PCC/ floor/ road and taking out cable and making good, including material as per existing after laying of pipe for cable protection all as specified and directed size of trench not more than 0.30 x 0.30 m complete all as specified and directed by EIC.
Taking up or down steel tubing and connection including cleaning for refixing or removal in store all as specified and directed of following size:-
25 mm bore
Supply, fixing & laying in repairs GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches/wall/ceiling/ floor/ all as specified and directed of following size Make: Surya Prakash / Jindal/ TATA /BST/ Swastik
25 mm bore
M&L for refixing of existing old GI tubing taking down under item 133, 68 & 70 above and connections in new or old position including cleaning internally and externally, any grade/make laid in trenches/wall/floor/ceiling including all type of new fittings i.e. sockets, Tee union elbow etc all as specified and directed of follwing size:-
25 mm bore
20 mm bore
15 mm bore
Taking out UNSV Gun metal globe & S&F Gun metal globe or gate valves, conf to IS 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position for following size:- Make: Leader/ Zoloto/ sant
25 mm bore
20 mm bore
Taking down u/s tank and Supply and fixing rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) tripple layer, ISI marked hoisting & fixed in position all as specified in SSR part-I of following capacity:- Make: Sintex (Ist Quality)/ Polywell/ Plasto
1000 ltr capacity
Taking down u/s float valve and M&L for PTMT float valve high pressure with high density plastic ball, with epoxy coated Aluminium rod screwed for iron pipe and fixed in all as specified and directed of following size:- Make- Prayag or equivalent as approved by the GE.
20 mm bore
Note for all items: All items shall be executed as specified and directed by Engr-in-charge.
S Balwinder Singh
M/s AJAY JAIN
Nakoda Constrcution Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .