| 1 | L1₹10.4 LAccepted-AOC NIL | THE NILGIRIS | TAMIL NADU | 638451 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹10.9 L+₹26,445 (2.48%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹11.2 L+₹52,465 (4.92%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹11.5 L+₹82,920 (7.77%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹11.7 L+₹1.0 L (9.84%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
6 Mar 2023, 6:00 pmClosed
GE AF KALAIKUNDA
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR/ MAINTENANCE OF E/M SERVICES AND REPLACEMENT OF ELECTRICAL FITTING, REWIRING AND ALLIED WORKS AT IN CERTAIN SMQs AND OMQs AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2023_MES_581023_1
C/8827/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE AF KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹20,000
Yes
2 May 2023
14 Feb 2023
7 Mar 2023
14 Feb 2023
6 Mar 2023
28 Feb 2023
Amount
Supply and fix in repair switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and fix switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and Fix, in repair switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed.
Supply and Fix, switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and Fix in repair switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed.
Supply and Fix switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
S & F in repair ceiling roses, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F ceiling roses, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
Supply and fix in repairs,bell push, flush type, single pole, 5 Amps, complete all as specified and directed.
Supply and fix ,bell push, flush type, single pole, 5 Amps, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and fix Round highway LED light 120 watt with PDC housing, 240 v, PF > 0.90, colour Temp 6500 K,IP66, System Luminious efficacy >110Lm/W, , make: Crompton cat part No.LBH11-120-CDL/60M or equivalent of make : Bajaj/Havells.
Supply and Fix in repairs, Bell Ding Dong, AC 230 volts, single pole, complete all as specified and directed.
M&L bell ding dong type,AC, 230 volts, single pole on PVC box complete all as specified and directed (Note : Item to be measured if executed under new point wiring)
M&L in repair lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box complete all as specified and directed
M&L lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box complete all as specified and directed (Note : Item to be measured if executed under new point wiring)
S&F in repair LED bulb 9/10 watt with B22 base, 1100 lumen, 6500 K complete all as specified and directed . i.Make : Crompton cat No :LED9WDFWB or equivalent in Wipro/Philips.
S&F LED bulb 9/10 watt with B22 base, 1100 lumen, 6500 K complete all as specified and directed . Make : Crompton cat No :-LED9WDFWB.(Note : Item to be measured if executed under new point wiring)
S&F LED 20 Watt tube light fitting (T8 type) ,single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. Note 1 : Make of batten and LED tube lamp should be of same make. Note 2 : Item to be measured if executed under new point wiring
Taking down old unserviceable TPN / SPN MCB DB's incl MCB of any size and any discription complete all as specified and directed .
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts,IP-43, 100 amps rated copper busbar 4 way Double door ( Vertical DB with MCB as incomer) Confirming to IS as per IEC 61439-3 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. . Note: DB and MCCB/MCB shall be of same make.
S&F sheet metal enclosure for VT DB TPN, MCB DB TPN 4 way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 63 Amp, 25 kA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. Make Legrand cat no:507745 and MCCB, TP, 25 kA , Cat No.420043 or equivalent of make: Seimens/ Schneider/ Hager/L&T. (Note: DB and MCCB/MCB shall be of same make).
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder/ L&T/Hager. Note: DB and MCCB/MCB shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed .Make- Legrand/ Seimens/ Schinder/ L&T.
S&F in repair MCB TP 25 to 63 amps 10 KA , 'C' Curve including connection with suitable size copper lugs complete all as specified and directed Make- Legrand/ Seimens/ Schinder/L&T/ABB/Hager.
S&F in repair MCB FP/TPN 40 to 63 Amps, 10 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs complete all as specified and directed . Make- Legrand/ Seimens/ Schinder/L&T/ABB/Hager.
S & F in repair circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S&F in repair MCB SPN 6 to 32 amps 10 KA , 'C' Curve including connection with suitable size copper lugs complete all as specified and directed Make- Legrand/ Seimens/ Schinder/L&T/ABB/Hager.
Supply and fixing in repair of stepped type electronic fan regulator 100 watt flush type (mini) on the existing hylem laminated sheet etc as required complete all as specified and directed. Make: Anchor (mini) / L&T/ Havells/Hager
Supply and fixing of stepped type electronic fan regulator 100 watt flush type (delux) on the existing phenolic laminated sheet etc as required complete all as specified and directed Make: Anchor (Delux) / L&T/ Havells/Hager (Note : Item to be measured if executed under new point wiring)
S&F LED 20 Watt tube light fitting (T8 type) ,single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
S&F LED 2 X 18 Watt tube light fitting (T8 type) , including LED retrofit tube 2 x 18 W , with powder coated CRCA decorative box type batten suitable for surface mounting on wall, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting .and including taking down old unserviceable complete all as specified & directed . Note : Batten and tube shall be of same Make.
S&F LED tube lamp 18 Watt (reterofit type, T8 pattern, single/double side connection) LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete fitting to be fixed in existing or new batten/ patti including changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting including taking down old unserviceable complete.
S&F LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed.
S&F in repair LED 9/10 Watt tube light fitting intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed.
S&F in repair 18 Watt LED lamp 4 Pin type of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1800, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, ITHD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours necessary change in wiring complete all as specified and directed by EIC.
S&F in repair LED light with pressure die-cast housing along with prismatic polycarbonate diffuser and LED's with secondary optics and colour Temp 5700K ,IP-66 protection ,4KV internal surge protection of 25 watt, PF>0.95, luminaire efficacy >110 lm/ W for building security light complete all as specified and directed by Engineer in charge.including taking down old u/s.
S & F in repair LED bulkhead light with pressure die-cast housing light fittings nominal power 12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed.
S & F LED bulkhead light with pressure die-cast housing light fittings nominal power 12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLSH cable as per IS 694: 2010 (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable as per IS 694: 2010 drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete all as specified and directed. .
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 32 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 6.0 sqmm + 1 x 6.0 Sqmm earth wire) complete all as specified and directed
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping all as specified and directed,
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.complete all as specified and directed by Engr-in-charge.
M & L point wiring with 1.5 Sqmm multi stranded copper conductor 1100 V grade,as per IS 694: 2010, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including sunken in cast iron/MS/GI terminal box duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:- Note : (i) Contractor has to make the surface good after flushing the sunken box as existing without any extra cost (ii) Length or wiring 15 mtrs from switch board to be considered as one point wiring. (iii) Rate of circuit wiring from DB to switch board is included in unit rate of item.
(a) One light/fan/ call bell point controlled by one switch.
(b) One 3 pin socket outlet 5 Amps on independent board.
(c) One 3 pin socket outlet 5 Amps on same board.
All as per item No-45 here-in-before but for switch socket combination 5/15 Amps 3/6 Pin on independent board with 2.5 Sqmm (Nominal area) PVC insulated unsheathed, stranded copper conductor FRLSH cable (1100 Volts grade) complete.
M & L for power point wiring with 4.0 Sqmm multi stranded copper conductor 1100 V grade,as per IS 694: 2010, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 4.0 sqmm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, for industrial metal clad socket power point. Note : (i) Length of power point wiring from DB to industrial socket upto 20mtrs distance shall be considered as one point wiring.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electric connections all as directed specifed and directed by EIC Make : Secure (Model Saral) or eqivelent in L&T Note : Old meter to be deposite in AGE E/M store.
S&F in repair three phase, 4 wire direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V( P-N) and 400/415V (P-P), 20-100 Amp, sprint 350, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electrical connections, connecting PVC cable by providing suitable size copper lugs etc, all as directed specifed and directed by EIC Make : Secure (Model Sprint 350) or eqivelent in L&T Note : Old meter to be deposite in AGE E/M store.
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old u/s one complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T/Hager.
S&F in repairs laminated hylam sheet cover, ISI marked with CM/L no., cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed by EIC of following sizes.
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk steel terminal boxes GI/MS /pressed steel terminal bos to be concealed in wall amd including laminated hylam sheet cover min 2.8 mm thickness, ISI marked with CM/L No. flush type boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
All as per item No.52 here-in-before but for 3 pin socket outlet, 5 Amp on the same board with other switches, complete all as specified and directed.
All as per item No. 52 here-in-before, but for 3 pin 5 amp switch socket combination on independent board with other switch complete all as specified and directed.
All as per item No. 52 here-in-before, but for bell buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 Sqmm. complete all as specified and directed.
All as per item No. 52 here in before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed by EIC.
All as per item No.52 here -in- before but wiring with 4.0 Sq mm FRLSH mutistranded copper conductor cable for Industrial metal clad socket with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete but excluding sunken box and hylam sheet all as specified and directed.
Supply and Fixing in repair Modular metal flush box of 1/2 module including taking out unserviceable including make good to match with existing surface complete all as specified and directed by EIC.
Supply and Fixing in repair Modular metal flush box of 3 module including taking out unserviceable including make good to match with existing surface complete all as specified and directed by EIC.
Supply and Fixing in repair Modular metal flush box of 4 module including taking out unserviceable including make good to match with existing surface complete all as specified and directed by EIC.
Supply and Fixing in repair Modular metal flush box of 6 module including taking out unserviceable including make good to match with existing surface complete all as specified and directed by EIC.
Supply & fixing Modular white cover plate with frame 1 module including taking down unservieable complete all as specified and directed by EIC.
Supply & fixing Modular white cover plate with frame 2 module ncluding taking down unservieable complete all as specified and directed by EIC.
Supply & fixing Modular white cover plate with frame 3 module ncluding taking down unservieable complete all as specified and directed by EIC.
Supply & fixing Modular white cover plate with frame 4 module ncluding taking down unservieable complete all as specified and directed by EIC.
Supply & fixing Modular white cover plate with frame 6 module ncluding taking down unservieable complete all as specified and directed by EIC.
Supply & fixing Modular white cover plate with frame 8 module ncluding taking down unservieable complete all as specified and directed by EIC.
Supply and Fix in repairs, decorative wall light fixture Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base. (Spiral B-22 base) complete all as specified and directed. [Model .LHFOAJE1TN1I060 for light fitting and lamp Make 'Havells' or equivalent Model of Make 'Philips'/ 'CG']
Taking down existing unserviceable CFL light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , white powder coated CRCA housing with LEDs, seam less front frame with flat white high transmission acrlyic cover, classic design with glare free soft illumination, cool white, having lumen efficacy not less than 100 Lumen/ watt including making electric connection from source with PVC sheathed copper conductor wire and fixing light in celing by all providing all arrangements complete all as specified and directed .Make : Crompton Part No. LCTLRNE36FOCDL or equivalent in Philips/ Havells/ Wipro/Century
S&F in repairs wall mounted bed side study lamp aluminium body, 3 W LED type warm white including LED driver with on /off button switch ,flexible pipe with lamp head 360 degree rotating type, 220 Volts, including taking down old u/s. Make : Philips cat No:-48042 or equivalent of make: Havells/Jaquar complete all as specified and directed by Engr- in- charge.
S&F in repair LED lamp 6 watt round recess mounted LED edge lit slim downlight with base GU - 10, CCT 2700K,Efficacy > 100 lm/w with 2.5K surge protection including taking out old u/s complete all as specified and directed by EIC. Make : Crompton Cat Part :- LSCRM-6W-CDL or equivalent of make:Wipro/Philips/Bajaj/Havells .
Supply and Fix in repairs, Modular Switch, one way, 6 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Switch, one way, 16 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Bell switch , 6 Amps, 1 Module, complete all as specified and directed.
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed.
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings including complete all as specified and directed.
Supply and Fix in repairs, Modular Fan step regulator, 100W - 1 module,complete all as specified and directed.
S&F in repairs PVC insulated, Single core, unsheathed, HRFR copper conductor flexible cable, 1100 Volt, Conf to IS 694, ISI marked of size 16 Sqmm including copper lugs, brass nut and bolt with washer of suitable size as per site requirement to connect the cable complete all as specified and directed
Ganguly Construction
M/S. CONCO CONSTRUCTION
SUMAN CONSTRUCTION
Neha Enterprise
M/S Jamuna Traders
SENCO
Guru Charan Mahata
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .