Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC 186 B DIAMOND HARBOUR ROAD KOLKATA 700 060 | KOLKATA | WEST BENGAL | 700060 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹42.3 L+₹1.8 L (4.48%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.7 L+₹4.2 L (10.3%)Rejected-Finance VILL JETHIA NATUN PARA PO JETHIA HALISAHAR PIN 743135 | 24 PARAGANAS NORTH | WEST BENGAL | 743135 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.6 L+₹6.1 L (15.0%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹47.3 L+₹6.7 L (16.6%)Rejected-Finance 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700 022
REPAIR / MAINT OF GEYSERS WITH ALLIED WORKS SERVICES FOR INSIDE AND OUTSIDE FORT WILLIAM UNDER GE FW KOLKATA
2020_MES_376147_1
GE(FW)/8678/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Fort William Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (FW) Kolkata
₹80,000
Yes
31 Oct 2020
9 Sept 2020
5 Oct 2020
9 Sept 2020
3 Oct 2020
24 Sept 2020
60 days
Amount
Taking down geysers any type and capacity (25/50 ltrs) from the existing position in wall and removing to stores for repairs, cleaning and re-fixing the same in original position after repairing including electric and water connection, testing etc complete all as directed by Engineer-in-Charge Notes : (i) Parts/accessories for geysers to be replaced shall be measured and paid separately under relevent items. (ii) Parts/accessories replaced against each geyser shall be recorded in tabular form in the MB. (iii) MES No. of geysers repaired shall be recorded in MB.
Supply and fixing in repair Copper heating element tubular/spiral steel type element 1500 Watt (ISI Marked) suitable for 25 litres capacity as per sample after removing the existing defective element complete all as directed by Engineer-in-Charge.
Supply and fixing in repair Copper heating element tubular/spiral steel type element 2000 Watt (ISI Marked) suitable for 25 litres capacity as per sample after removing the existing defective element complete all as directed by Engineer-in-Charge.
Supply and fixing in repair Porcelain heating element 1500 Watt (ISI Marked) suitable for 25 litres capacity as per sample after removing the existing defective element complete all as directed by Engineer-in-Charge.
Supply and fixing in repair Porcelain heating element 2000 Watt (ISI Marked) suitable for 25 litres capacity as per sample after removing the existing defective element complete all as directed by Engineer-in-Charge.
Supply and fixing in repair thermostat switch ISI marked for geysers of 25-50 litres capacity of micro gap steam type thermostat SEA and make as per sample approved by Engineer-in-charge, including testing complete.
Supply and fixing in repair thermostat switch ISI marked for geysers of 25-50 litres capacity of micro gap steam type thermostat TSE and make as per sample approved by Engineer-in-charge, including testing complete.
Supply and fixing in repair thermal cut switch ISI marked for geysers of 25-50 ltrs capcity, make as per sample approved by Engineer-in-charge, including testing complete.
Supply and fixing in repair thermostat auto cut off switch ISI marked for geysers of 25-50 ltrs capcity, make as per sample approved by Engineer-in-charge, including testing complete.
Supply and fixing in repair brass aperture plate complete with pluger pipe, bolts, nuts, and rubber ring complete and all connected components for 25 ltrs capacity geysers including testing complete all as per sample directed by Engineer-in-Charge.
Supply and fixing in repair split plate of 22 SWG MS sheet white stove enamelled suitable for bottom cover of 25 ltrs capacity geysers including testing complete all as per sample specified and directed by Engineer-in-Charge.
Supply and fixing in repair high density polythene pipe heavy duty confirming to IS 3075, 15mm dia, 600mm long, including brass coupling at each end (weighing not less than 40gms each) one end secured to inlet/outlet of geysers and other end to stop cock all complete with connection complete all as directed by Engineer-in-Charge.
Supply and fix in repair 20 Amps Metal clad socket 3 pin (2P+E), complete all as directed (Make : L&T, Cat No: MPS220S / HPL, Cat No: MHP2S20 / C&S, Cat No: CSDBSSPN020 or equivalent model in ABB / LEGRAND / HAVELLS / INDO ASIAN / HAGER / BCH / SCHNEIDER)
Supply and fix in repair 20 Amp Metal clad plug 3 pin (2P+E), complete all as directed Make : L&T, Cat No: MPS220P / HPL, Cat No: MHP2P20 / C&S, Cat No: CSDBPSPN020 or equivalent model in ABB / LEGRAND / HAVELLS / INDO ASIAN / HAGER / BCH / SCHNEIDER)
Supply and fixing of rubber/PVC gasket to ensure water tightness of 25 Ltr geyser suitable as per sample complete
Supply & Fixing in repairs Air release valve/dead weight Valve ISI mark suitable for 25 Ltr cap geyser specified and as direted by Engr-In-Charge.
Supply & Fixing in repairs Non return Valve brass of 15 mm bore after dismantling old unserviceable NRV of any size all as specified and as direted by Engr-In-Charge.
Supply and fixing glass wool (spl quality) at thermal insulation after removing the old glass wool in between the inner container and outer casing complete all as directed by Engineer-in-Charge.
Supply and fixing pilot lamps round neon indicator suitable for 25 ltrs capacity geyser fitted on the unit including necessary electric connection, testing complete including taking out old defective indicator complete all as specified and as directed.
Supply and fixing for replacement of SS Flexible connecting pipe of size 15mm dia, 600mm long with brass coupling and union at both ends heavy duty suitable for fix on 15mm dia GI pipe with washer complete and all as directed at site after takingout unserviceable one complete all as directed by Engineer-in-Charge.
Scraping, cleaning/removing deposited scales, correcting cavities as required for copper vessel outside surface, MS outer shell with top and bottom cover both surface shall be painted with two coat of synthetic enamel paint on outer surface of shell, top and bottom cover shall be painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and one coat of of red oxide to copper vessel outer surfaces and inner surface of outer shall geyser of any size 25/50 ltrs capacity and numbering/marking with different paint complete all as directed by Engineer-in-Charge.
Repairing leaked portion of inner tank of geyser of any type/capacity by mean of spot welding with slider/brass spot brazing and testing complete (Nos of spot welding not exceeding 5) complete all as directed by Engineer-in-Charge.
Supply and fixing mild steel bolts and nuts and washer 15mm dia 75mm to 100mm long with cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) including taking out old fixing bolt (set of four) from walls complete all as specified and as directed by Engineer-in-Charge.
S&F Mild steel clamp of flat iron of size (25X6mm ) made to shape 100mm long welded with outer casing of geyser to walls complete all as directed by Engineer-in-Charge.
S&F in repair copper inner tank for hard and soft water pressure upto 100PSI (7.00Kg/Cm2) and normal working pressure is 30 PSI(2.11Kg/Cm2) for 25 litres capacity geyser after removing the existing defective tank complete all as directed. (Make : Bajaj/Venus or equivalent as approved by Accepting officer )
Supply and fixing in repair stainless steel inner tank for hard and soft water pressure upto 100PSI (7.00Kg/Cm2) and normal working pressure is 30 PSI (2.11Kg/Cm2) for 25 ltrs capacity geyser after removing the existing defective tank complete all as directed by Engineer-in-Charge. (Make : Bajaj/Venus or equivalent as approved by Accepting officer )
Supply and fixing in repair mild steel outer cover 22 SWG for 25 ltrs capacity any dia of geyser including bottom and top cover with MS clamp, outer ring and split pin including two coats of paint over one coat of red oxide primer including dismantling the unserviceable cover as per direction by the Engineer-in-Charge.
S&F in repair PVC insulated and PVC sheathed 0.75 sqmm 3 core flexible copper cable of size 24/0.20, 1100 volts complete including taking down old flexible unserviceable wire complete all as directed by Engineer-in-Charge
Supply and fixing metal clad single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 'C' Curve, 10 KA including all accesories complete. (MAKE OF ENCLOSURE : LEGRAND, Cat No. 507814 / L&T, Cat No. DBMPS220SD / SCHNEIDER, Cat No. A9HMS220/C&S, Cat No: CSDBPSSPN020 / C&S, Cat No: CSDBPSSPN020 / HPL, Cat No: MDBSPMT20 / BCH, Cat No: BCHPSDBSPN20 / HAVELLS, Cat No: DHDPUSN020/DHDPUDP020 or Equivalent Model in ABB / INDO ASIAN / HAGER) (NOTE : Enclosure & MCB shall be same manufacturer)
Supply & fixing in repairs stop valves of 15mm size, cast copper alloy, screwed down, high pressure with crunch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete as direted.
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc. complete all as specified and as directed.
M&L for point wiring concealed with 2.5 sqmm (nominal area) PVC insulated stranded two run two core unsheathed FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC conduit with all fittings and accessories of PVC conduit (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLS copper cable as earth continuity wire connecting to common earth point .complete all as specified and as directed by Engr-in-Charge. (Note:- Cutting chases and making good of disturbed surfaces is deemed included in unit rate)
M&L for point wiring (Surface type) with 2.5 sqmm (nominal area) PVC insulated Multistranded single core unsheathed FRLS copper conductor cable 1100 Volts grade drawan through with and including PVC casing caping with all fitting and accessories of PVC cashing caping (like Tee, Bend etc) complete fixed to walls /ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, multistranded , single core FRLS copper cable as eath continuity wire cconnecting to common earth point on 1.6 mm thick PVC / plastic laminated sheet , top cover suitable sizes of brass screws and washers etc for mounting following point conrolled by one switches all as specified and directed.
S&F Switch and socket combination 6 pin 15 Amp AC 230 Volts piano flush button type (multi-purpose) complete all as specified and directed
S&F in repair Chromium plated brass Angular stop cock concealed type incl concealed body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : Essco, Cat No: DLX-526 / PRAYAG, Cat No: PR-144 / SOMANY, Model: ETHER / JAINKO, Cat No: AVJ-1)
S&F Plug Top 3 pin 15/16 Amp AC 230 Volts with indicator complete all as specified and directed
S&F PCB board for Geyser of capacity 25 litres AC 230 Volts complete all as specified and directed
M&L in repair for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and incl PVC casing-caping of suitable size, surface type including taking down existing wiring complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
S&F in repair flexi PVC hot/cold pipes with check nuts and washer of 450 mm long suitable for geysers complete all as specified and directed.
Supply and fixing in repair stop valve cast copper alloy, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or union for pipe 15mm bore, (ISI marked) complete all as specified and directed.
S&F, 15 mm bore fancy type stop valves, cast copper alloy, chromium plated (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and, complete all as specified and directed. (MAKE : ESSCO, Cat No: DLX-514B / PRAYAG, Cat No : PIS-18 / SOMANY, Model: ETHER / JAINKO, Cat No: CSV-1)
S. K. CONSTRUCTION SYNDICATE AND ENGINEERING CO.
BASU AND CO
M A ENTERPRISES
JAGATMATA ENTERPRISE
ARJUN DAS VALECHA
JOY-EN-JOY
GHOSH ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .