Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹37.7 L+₹2.0 L (5.72%)Rejected-AOC NOT FOUND | L2 | Rejected-AOC OK | |
| 3 | L3₹39.6 L+₹3.9 L (11.0%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹40.2 L+₹4.6 L (12.9%)Rejected-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L4 | Rejected-AOC OK | |
| 5 | L5₹41.8 L+₹6.1 L (17.2%)Rejected-AOC 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L5 | Rejected-AOC OK |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
21 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE AF Bhisiana
HQ CWE AF Bhisiana
CWE(BHI)/SIR-44/2022-23
2022_MES_570314_1
CWE(BHI)/SIR-44/2022-23
Open Tender
Civil Works
Item Rate
180 days
AF Sirsa
AS PER COVER 1
6 documents required · 6 mandatory
₹500
Yes
GE AF Sirsa
₹86,000
Yes
24 Jan 2023
22 Dec 2022
23 Jan 2023
22 Dec 2022
21 Jan 2023
9 Jan 2023
22 Dec 2022 - 29 Dec 2022
Amount
Supply, Installation, testing and commissioning DG Set 200 KVA (at 0.8 PF ) water cooled DG set 415 Volt 3 Phase 4 wire, 160 KW rating, frequency 50 HZ, power factor 0.8 lagging with acoustic weather proof enclosure as per CPCB norms etc complete comprising the following:- Engine:- Engine with direct injection, water cooled engine, in-line/V-type, 4 stroke, rated at 1500 RPM, rated output (prime power rating as per ISO 3046) 183 KW, rated output (prime power rating as per ISO 3046) 248 HP conforming to ISO 3046 / BS 5514 has the following specifications: - Mechanical FIP - Electronic Governor - Turbocharger, exhaust manifold, stainless steel exhaust flexible connection - Radiator cooled with turbocharged after cooled -Plate type lube oil cooler -Filter –fuel, lube oil - Dry type replaceable paper element air cleaner - Flywheel housing and flywheel to suit single bearing alternator - Starting motor – Electric, battery charging alternator - First fill lube oil and coolant Alternator: - Meccalte / (Optional -Stamford/ Crompton Greaves /equivalent) -200 KVA full load current 278 Amp -brushless alternator - Self-excited, self-regulated - Class ‘H’ insulation limited to temperature rise of class H - Salient pole revolving field - Single bearing - Automatic voltage regulator -Insulation Class H -Overload Withstand capacity (10% Overload for 1 hour once in 12 hours) -Over speed capacity (1800 RPM for 2 min) -Cooling system alternator- Self Colling - Voltage regulation + 1%
Acoustic enclosure – Engine alternator assembly mounted on AVM with Silencer and S.S exhaust bellow suitably optimized to meet stringent sound & emission standards as laid down by MOEF / CPCB ( Insulation thickness 50 mm) - Base rail with draw-out type fuel tank is provided with a drain plug, air Vent inlet and outlet connections, level indicator, manhole etc. - Sub-base fuel tank with 10 hours capacity - 12 V/24 V dry type, 2 x 150 AH, batteries with connecting leads and terminals -90% gloss RAL9003 white pure polyester powder coated, base in black colour Miscellaneous:- Suitable PCC foundation as per manufacturer recommendations and as directed by Engr-in-charge. -Microprocessor based control panel with low lube oil safety, high engine temperature protection, high canopy temperature protection, engine speed protection, low coolant level protection, over KVA & KW protection, over current protection, overvoltage & under voltage protection, phase sequence monitoring. DG set also have digital display and should display following parameters:- Engine oil pressure, Engine temperature, Lube oil temperature, canopy temperature, battery voltage, Engine RPM, Running Hours, Fuel level indicator, L-L and L-N Voltage, frequency, kW, kVA, KWH reading. -Automatic main failure by pass arrangement with On Load Changeover Switch 400 Amps 4 Pole factory made control panel as per manufacture,s spectification suitable for DG set cap 200 KVA grouted in floor, PCC Foundation including following accessories (i) MCCB 4 Pole 400 Amps 25 KA- 02 Nos (ii) Power contactor 4P 400 Amps AC3 duty -02 Nos (iii) Indicating LED for Load ON Mains, Load on Set, Mains ON, DG Set ON (iv) Multi Function Digital Meters with RS-485 - 01 No. (v) AMF Controller with RS-485 DGC-11-6500T- 01 No. (vi) DC Ampere Meter- 01 No.(vii) Start/ Stop push button- 02 Nos.
Supply, Installation, testing and commissioning DG Set 62.5 KVA (at 0.8 PF ) water cooled DG set 415 Volt 3 Phase 4 wire 50 KW rating, frequency 50 HZ, power factor 0.8 lagging with acoustic weather proof enclosure as per CPCB norms etc complete comprising the following:- Engine:- Engine with direct injection, water cooled engine, in-line/V-type, 4 stroke, rated at 1500 RPM, rated output (prime power rating as per ISO 3046) 61 KW, rated output (prime power rating as per ISO 3046) 83 HP conforming to ISO 3046 / BS 5514 has the following specifications: - Mechanical FIP - Mechanical governor / Electronic Governor - Turbocharger, exhaust manifold, stainless steel exhaust flexible connection - Radiator cooled with turbocharged after cooled -Plate type lube oil cooler -Filter –fuel, lube oil - Dry type replaceable paper element air cleaner - Flywheel housing and flywheel to suit single bearing alternator - Starting motor – Electric, battery charging alternator - First fill lube oil and coolant Alternator:- Meccalte / (Optional -Stamford/ Crompton Greaves /equivalent) -brushless alternator - Self-excited, self-regulated - Class ‘H’ insulation limited to temperature rise of class H - Salient pole revolving field - Single bearing - Automatic voltage regulator Acoustic enclosure – Engine alternator assembly mounted on AVM with Silencer and S.S exhaust bellow suitably optimized to meet stringent sound & emission standards as laid down by MOEF / CPCB - Base rail with draw-out type fuel tank is provided with a drain plug, air Vent inlet and outlet connections, level indicator, manhole etc. - Sub-base fuel tank with 10 hours capacity - 12 V/24 V dry, batteries with connecting leads and terminals -90% gloss RAL9003 white pure polyester powder coated, base in black colour
NOTE :- Monitoring Features :- (i) Phase Voltage & Currents, Frequency, Reverse power, Genset KVA, KW, KVAr, KWH, power factor, canopy temperature. (ii) Lube oil pressure, Engine temperature, RPM, run hours, number of starts, fuel level, auto/manual stop. (iii) Battery charging status. (iv) AMF feature. (v) Modbus communication, synchronization, remote monitoring. Diagnostic Features :- (i) Battery charging failure, over/under speed, over current, over/under voltage, over KW, phase seq., phase missing, mains under voltage, earth fault trip, fuel usage alarm. (ii) Low lube oil pressure, high engine temperature, low/high battery voltage, low fuel level, over crank protection, routine maintenance indicator, Genset Test facility, mains frequency.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6.3mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x4mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed.
Supply and lay cable XLPE Insulated PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core with necessary aluminium thimbles for fixing, complete all as specified and directed.
Supply and lay cable XLPE Insulated PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core with necessary aluminium thimbles for fixing, complete all as specified and directed.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Hard/ Dense soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
M&L Sand Cushioning dry fine Sand in trenches 80mm thick before laying the Cable and 150mm thick after laying the Cable, complete all as specified and as directed.
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt for Cable Protection, complete all as specified and as directed.
shiv shanker enterprises
SARAOGI BUILDERS LIMITED
Ajay Enterprises
MONA GENERATOR SEVICES PVT. LTD.
Aman Enterprises
Rasvinderpalandco
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .