| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹49.2 L+₹2.4 L (5.23%)Rejected-Finance | L2 | Rejected-Finance Not Lowest |
Tender Value
₹50.5 L
EMD Value
₹1.0 L
Closing Date
24 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Pune
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85880REPAIR TO HT OVERHEAD AND UNDERGROUND EXTERNAL ELECTRIC SUPPLY LINE AND OTHER ALLIED SERVICES AT MINTSD , EME WKSP, ALC, MH (CTC), CH (SC) AND ADJOINING AREA UNDER GE (S) PUNE.
2020_MES_369183_2
85880REPTOHTCABLEATGESPUNE
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE South Pune
As per Tender
9 documents required · 9 mandatory
₹1,000
GE South Pune
₹1.0 L
Yes
24 Feb 2021
10 Dec 2020
26 Dec 2020
10 Dec 2020
24 Dec 2020
10 Dec 2020
60 days
Amount
Excavation in trenches in soft /loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. and for foundation of poles, stays etc. n exc 10 sqm on plan and n exc 1.5 in depth and getting out complete all as specified.
All as per item No 01 here- in- above but depth exceeding 1.5 m and not exceeding 3.00 m complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick of soft /loose soil in trenches /pit complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed not exceeding 1.5 m above the starting point complete all as specified and directed.
Taking up old unsv HT /LT cable 70 sqmm to 120 sqmm from trenches, drain , road or on poles complete all as directed
Supply and laying XLPE Insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, in trenches /fixed on wall /floor of cross sectional area 70 sqmm 3.5 core complete all as directed.
Supply and laying XLPE Insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts grade,in trenches /fixed on wall /floor of cross sectional area 95 sqmm 3.5 core complete all as directed.
Laying only old serviceable HT underground cable 95 to 185 sqmm , 11000 /22000 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of following sizes all as directed retrieved from item Sl No. 5 above.
Supply and laying, testing and commissioning of HT Underground XLPE insulated, screened PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with aluminium conductor 11 KV grade(Earthed) of 95 sqmm 3 core cable comfirming to IS-7098 Pt-II cable laid in trenches/ walls/ ducts/ poles including taking out the old one complete all as specified and as directed.
All as per item No 09 here- in- above but 120 sqmm, 3 core, 22000V complete all as specified and as directed.
Disconnecting and taking down HT UG cable from HT pole/ Transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, out door type with and including suitable size of cold shrinkable new end connection jointing kit 11000 voltage grade and aluminium lugs duly crimped with crimping tool for the cable size of HT 95 sqmm XLPE cable:-
All as per item No 11 here- in- above but for 120 sqmm 3 core complete all as specified and as directed.
Disconnecting and taking down HT UG cable from VCB and cutting faulty end portion of the cable, dressing properly and making good end termination, in door type with and including suitable size of cold shrinkable new jointing kit 11000 voltage grade and aluminium lugs duly crimped with crimping tool for the cable size of HT 95 sqmm XLPE cable:-
All as per item No 13 here- in- above but for 120 sqmm 3 core complete all as specified and as directed.
Supply and jointing cable for jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing materials and accessories suitable for 95 sqmm 3 core XLPE armoured aluminium conductor cable incl excavation and taking up loop all as specified and directed by Engr -in- Charge.
All as per item No 15 here- in- above but for 120 sqmm 3 core complete all as specified and as directed.
Disconnecting and taking down HT UG cable from VCB and cutting faulty end portion of the cable, dressing properly and making good end termination, in door type with and including suitable size of cold shrinkable new jointing kit 22000 voltage grade and aluminium lugs duly crimped with crimping tool for the cable size of HT120 sqmm XLPE cable:-
All as per item No 17 here- in- above but for 150 sqmm 3 core complete all as specified and as directed.
Disconnecting and taking down HT UG cable from HT pole/ Transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, out door type with and including suitable size of cold shrinkable new end connection jointing kit 22000 voltage grade and aluminium lugs duly crimped with crimping tool for the cable size of HT 120 sqmm XLPE cable:-
All as per item No 19 here- in- above but for 150 sqmm 3 core complete all as specified and as directed.
Supply and jointing cable for jointing kit for 22 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing materials and accessories suitable for 120 sqmm 3 core XLPE armoured aluminium conductor cable incl excavation and taking up loop all as specified and directed by Engr-in-Charge.
All as per item No 21 here- in- above but for 150 sqmm 3 core complete all as specified and as directed.
Dismantling of overhead line insulators and removal of old unserviceable pole /strut including reconnecting on new poles all as directed by engineer in charge all as directed
Supply, errecting & fixing in replacement in steel pole type 410 SP 55 (11 mtr) true vertical position pole conforming to IS-1678 of 11 m long complete all as specified and as directed .
Material & labour cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed by Engineer- in-charge.
Material & labour PCC 1: 3 : 6 type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in mass concrete including necessary form work complete all as specified and directed.
Dismantling unserviceable stay assembly complete and removing from site .
Supplying and fixing in replacement galvanized stay stranded wire of size 7/4 mm and fixing to stay assembly complete all as shown in electrical plate No 1 of SSR-2009 (Part-I) complete all as specified and directed.
M & L for GI Stay assembly set comprising of 14 mm dia 400 mm iron stay bow, 2150 mm long stay rod 20 mm dia, stay plate 300 x 300 x 6 mm thick complete with all aceessories as shown in electric plate no 1 of MES schedule Part I complete. Note :- Earth work, PCC, loop type insulator, galvanized stay stranded wire will be measured separately.
Supply & fixing loop type insulator, vitreous porcelain, white brown or green with over all dimensions 90 mm x 140 mm, clearance of hole 25.5 mm suitable for 11000 volts complete all as specified and directed.
Dismantling unserviceable cross arms, clamps etc and removing from site .
Material & labour for Cross Arms bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts , washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Dismantling unserviceable galvanized earth steel wire 3.15 or 4 mm dia and existing hexagonal cradle guard HT/LT poles and removing binding wire and removal of the same from site complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of cradles, hexagonal /Rectangular, fabricated with galvanized steel wire 4 mm dia including stretching, sagging and jointing in position as a continuous earth wire on pole and for guarding complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable /old ACSR conductor any size from over head lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and directed.
Supply and fixing Aluminium conductor steel reinforced (ACSR) of any size for HT/ LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape incl jumpers complete connecting of disconnected cable,service cable and street light connection complete all as specified and directed by Engr In charge.
Dismantling of air break gang operated switches vertical /horizontal 11/22KV mounted including insulators and operating mechanism and removing the same from site complete all as specified and directed.
M & L for switch air break gang operated triple pole mechanically operated mounted on HT insulators horizontal type and ms galvanized steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia /25 mm dia as reqd GI medium grade for current rating upto 400 Amps 11000 volts complete with locking arrangement ,ms clamps ,bolts ,nuts and washers etc.including two coat of aluminium paint over a coat of red oxide primer on ms work complete all as specified complete all as specified and directed.
Supply and fixing in replacement of drop out fuse assy single pole 11 KV , 25 Amps rating complete expulsion fuse element mounted on four /two pole structures all as specified and directed.(Note : Necessaty Nut, bolt and washers should be included in above quoted rate)
M & L for switch air break gang operated triple pole mechanically operated mounted on HT insulators horizontal type and ms galvanized steel frame with operating mechnizing worked from ground level including operating rod of size 32 mm dia /25 mm dia as reqd GI medium grade for current rating upto 400 Amps 22000 volts complete with locking arrangement ,ms clamps ,bolts ,nuts and washers etc.including two coat of aluminium paint over a coat of red oxide primer on ms work complete all as specified and directed.
Supply and fixing in replacement of drop out fuse assy single pole 22 KV , 25 Amps rating complete expulsion fuse element mounted on four /two pole structures all as specified and directed.(Note : Necessaty Nut, bolt and washers should be included in above quoted rate)
Material & labour for replacement of electromechanical IDMT relay Digital Numeric type IDMTL Relay with short ckt. Over current and earth fault relay with fault recording Facility including replacement of existing thermal magnetic relay with adopter plate and setting of the Relay as per connected load etc. complete as directed.
Supply and fixing in replacement operating rod of switch air break gang operated triple pole ,steel water tube medium grade of size 25 mm dia conforming to IS 1239 of 1990 for fixing as fixed with ms galvanized steel frame including necessery welding, nuts, bolts or washers etc all as directed by Engineer -in -charge .
Supply and fixing in replacement steel tube of size 100 dia , light grade galvanised with all fittings fixed to walls /floors /poles or under road etc of following sizes complete all as specified and directed.(Note:-The GI pipe should be fixed with pole by MS clamps. (The MS work should be measured and paid separately).
All as per item No 44 here- in- above but of 80 mm complete all as specified and directed.
Dismantling insulator any type / any size from LT /HT poles complete all as directed.
Supplying and fixing in replacement pin type insulator, HT porcelain vitreous white, brown or green of size 150 mm high and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut suitable for 11000 volts complete all as specified and directed.
Supply and fixing in replacement insulator disc type single disc assembly, ISI marked working pressure 11000 volts, porcelain vitreous white, brown, or green size 145 mm high and 255 mm dia ball and socket with tension clamp to suit the size of conductor (ACSR) complete all as specified and directed.
Supply and fixing in replacement of post top insulator 11000 volts suitable for air break switch /drop out fuse with necessary nuts, bolts, washers including taking out existing unserviceable one complete all as specified & directed.
Material & Labour painting of steel tubular HT poles including cross arms, clamps, back plates etc in situ on with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces including making white and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking of pole No , Feeder No also complete all as specified & directed.
All as per item No 50 here- in- above but on 2 pole structures painting incl bracings complete all as specified and directed.
All as per item No 50 here- in- above but on 4 pole structures painting incl bracings complete all as specified and directed.
Stringing / stretching , incl jointing in situ of each span not more than 55 m of two electric poles having 3 nos of ACSR of any size including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as ordered manually or by telephonically means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered.(Note:-One RM including 3 wire of HT over heed line and two nos of earth wire.)
Prunning / trimming the branches of trees alongwith overhead line of any description, 3 m on all side below/ above/ sides of overhead line and removing the same upto 150 m away complete all as specified and directed by Engineer-in-Charge (The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required).
Testing and fault locating of HT underground cable with the help of cable fault locating machine at site including removal of moisture content from cable all as directed.(Note:- The machine for locating of fault will be arranged by the contractor .The quoted rate is included for the fault locating machine. Necessary excavation , earthwork etc measured and paid separately under Sch 'A').
Taking down the faulty/ damaged the HT U/G cables 95 to 185 sqmm of size, cutting/ dressing end portion and making good end termination with HT sealant tape and including suitable size of aluminium lugs duly crimped with crimping tool and refixing its own position ,including Jumpers, Insulation tape, nut ,bolts etc as reqd .
Surface excavation n exc 30 cm depth and averaging 15 cm depth and getting out in soft /loose soil including clearing away all grass and vegetation saplings , shrubs , bushes , undergrowth roots and removing rubbish upto a distance n exc 50 m outside the perifery of the transformer/ 2 pole /4 pole structure/ feeder pillar area.(Note:-The contractor will ensure that no vegetation grows during the contract period on the area so excavated)
Repairs to existing three pole gang operated air break switch horizontal /vertical type incl taking down old unsv male/female contacts and providing in replacement new male /female contacts copper with silver coated ,spring loaded suitable for 200 Amps complete with jumpers from GOD to OH line & DO to GOD complete with aluminium thimbles of suitable size incl HT tape as reqd for repairing HT end termination joint complete all as specified and directed.(Note:-The cost of Male / Female contats should be measured and paid separately as supply only under revant items of Sch 'A').
Supply only Male Contact/ Moving Contact Blade Copper 100A suitable for air break switch, heavy duty complete all as specified and directed.
Supply only Female Contact/ Fixed Contact Copper 100A suitable for air break switch, heavy duty complete all as specified and as directed.
M & L for Replacement of old jumper ACSR (conductor size not less than weasel) upto length 1.5 m for LT/HT OH line all as directed.
M & L for Replacement of old jumper ACSR with Alkathene pipe sleeves (conductor size not less than mink) upto length 3.5 m for HT with Aluminium thimble (If necessary).
S&F in replacement of compression/ crimping type sleeve joints for jointing conductors/jumpers connections size upto 10 mm dia of conductor wire overall including removing of old jumper complete all as specified and as directed.
S&F expulsion fuse single pole (DO fuse element) 11000/22000 V of the following ratings, upto 25 Amps Capacity complete all as specified and as directed.
All as per item No 64 here- in- above but 10 Amps& upto 50 Amps Capacity complete all as specified and directed.
All as per item No 64 here- in- above but 5 Amps Capacity complete all as specified and directed.
M & L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures, and conventional skull and bones, in signal red colour and fixed with MS clamps of flat iron of size 25 x 5 mm, bolts, and nuts of approved size, for HT 25 X 20 cm complete all as specified and directed.
Supply and fixing HT cable route/joint indicator made of Cast iron fixed in PCC block cast in situ of size 0.2 x 0.2 x 0.3 m on angle iron of size 40 mm x 40 mm x 5 mm with nut, bolt & washers of suitable size complete all as specified and directed.
M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete. Note : GI earth strip and protection pipe beyond 7.5 m will be measured and paid separately.
All as per item No 69 here- in- above but using galvanized iron strip 32 x 6 mm as earthing lead and GI protection pipe medium grade 40 mm dia complete all as specified and directed.
Dehydration and filtration of used transformer oil of existing transformer of capacity upto 750 KVA in position using filtration & dehydration machine with staandby supply source at site to obtain dielectric strength more than 40 KV at 2.5 mm gap including, testing complete .
Supply only HV bushing (11000 voltage grade) with heat resistant gasket suitable for following capacity of outdoor / indoor type transformer 100 KVA to 160 KVA complete all as specified and directed.
All as per item No 72 here- in- above but of 200 KVA to 500 KVA complete all as specified and directed.
All as per item No 72 here- in- above but of upto 750 KVA complete all as specified and directed.
Supply only HV bushing (22000 voltage grade) with heat resistant gasket suitable for following capacity of outdoor/indoor type transformer:-
Supply only copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV side 11000/22000 volts grade for following capacity of outdoor/indoor type transformer 100 KVA to 160 KVA complete all as specified and as directed.
All as per item No 76 here- in- above but 200 KVA to 500 KVA complete all as specified and as directed.
All as per item No 76 here- in- above but up to 750 KVA complete all as specified and as directed.
Supply only LV bushing (415 voltage grade) with heat resistant gasket suitable for following capacity of outdoor/indoor type transformer 100 KVA to 160 KVA complete all as specified and directed.
All as per item No 79 here- in- above but of 200 KVA to 400 KVA complete all as specified and as directed.
All as per item No 79 here- in- above but of 500 KVA to 750 KVA complete all as specified and as directed.
Supply only copper terminal stud both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV side 415 volts grade for following capacity of outdoor/indoor type transformer 50 KVA to 160 KVA complete all as specified and directed.
All as per item No 82 here- in- above but of 200 KVA to 400 KVA complete all as specified and as directed.
All as per item No 82 here- in- above but of 500 KVA to 750 KVA complete all as specified and as directed.
Replacement of silicagel breather filled with silicagel for transformer of capacity up to 500 KVA complete.
M&L for replacement of Lightning arrestors expulsion type complete with all fittings, 30 KA discharge capacity,distribution class made out of silicon polymeric housing all as directed
Isolating 11/22KV HT overhead supply from the substation and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips,removing transformer and taking out from substation or taking down from 2/4 pole structure ,lifting arrangements,transporting to authorized service centre/work shop for repair and back to the installation after repair including installing, commissioning and testing of the capacity .
All as per item No 87 here- in- above but of 100 KVA to 200 KVA complete all as specified and as directed.
All as per item No 87 here- in- above but of 250 KVA to 400 KVA complete all as specified and as directed.
All as per item No 87 here- in- above but of 500 KVA to 750 KVA complete all as specified and as directed.NOTE:-Spares/parts required to be replaced shall be measured and paid separately forsupply only items . Necessary T&P should be arranged by the contractor.The rate of T&P is included in above quoted rate
Draining out the complete transformer oil and keeping in safe custody in clean and dry containers for reuse. Opening the top cover of the transformer,disconnecting and taking out complete core assy and dismantiling it for checking the serviceability of the coil winding,checking the condition of the body,cleaning the tank and remove sludge/dirt,cleaning the coils limbs,refixing of core,core assy,tap changer assy,HT/LT winding connection,terminal studs of HT/LT sides and reassembling of transformer after repairs,refitting the transformer coil incl improvement of insulation resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of engr-in-Charge .
All as per item No 91 here- in- above but of 100 KVA to 200 KVA complete all as specified and as directed.
All as per item No 91 here- in- above but of 250 KVA to 400 KVA complete all as specified and as directed.
All as per item No 91 here- in- above but of 500 KVA to 750 KVA complete all as specified and as directed.Note:- Spares/parts required to be replaced shall be measured and paid separately as supply only.
Supply only(HV side) copper winded coil of existing type size and gauge 11000 V complete with insulating material for transformers 100 KVA to 750 KVA complete all as specified and as directed.
Supply only(HV side) copper winded coil of existing type size and gauge 22000 V complete with insulating material for transformers 100 KVA to 750 KVA complete all as specified and directed.
All as per item No 96 here- in- above but LT side,415 V graded complete all as specified and as directed.(Note for 95 to 97: Actual weight of the each coil shall be measured and paid fitting charges of formed coil included in serial No 91 above)
Supply and fixing in replacement new off load tap changer assembly complete,making connection and testing complete of the transformer of 100 KVA to 200 KVA capacity complete all as specified and as directed.
All as per item No 98 here- in- above but of 250 KVA to 400 KVA complete all as specified and as directed.
All as per item No 98 here- in- above but of 500 KVA to 750 KVA complete all as specified and as directed.
M&L for replacement of cork sheet gasket of 06mm thick for transformer tank all as directed by Engr-in-Charge
M&L for cold rolled grain oriented core (CRGO) Lamination sheet strips for transformer Core upto 50 to 500 KVA capacity all as specified and directed
M&L for Isolating 11 KV HT cable and earthing the complete system opening and taking down top cover of the transformer of any capacity installed on 2pole/4pole structure or indoor/outdoor sub stn. Drain out the transformer oil up to the required level for repair/replacement of part and keeping in safe custody for reuse. refilling transformer oil,refixing the top cover, taping and commissioining of the transformer after the repairs
M&L for overhauling of HT OCB 11KV,400A,250 MVA incl replacement of transformer oil,Fixed and moving contacts and control wiring suitable for alphanumeric relay all as specified and directed by Engineer in Charge.
M&L for HT bus bar for 2/4/6 pole structure made out of aluminium tube having outer dia 32 mm and 06 mm thick suitable for 22 KV/11KV complete with all suitable joints with SS/GI nut bolts etc and colour sleeve as per colour code incl dismantling old unsv busbar all as specified and directed
M&L for aluminium strip 25x4 mm of required length for jumpering purpose in 11/22 KV DP/FP including taking down existing aluminium conductor etc all as per the direction of Engineer-in-charge
M&L for stone metal of grading not exceeding 40 mm deposited and spread and leveling in layers not exceeding 15 cm thick watered and rammed to a true surface all as specified and directed by Engr- in - Charge.
M&L for new transformer oil as per IS:335 reqd for topping in various transformers all as specified and directed.
Disconnection of HT & LT cable from Transformer end terminals of capacity 400 KVA , 22KV/440 volt step down transformer and shifting of Transformer,LT Control panel,capacitor panel and connecting to rerouted system after construction of foundation with in 50 mtrs complete and Reconnecting of all as specified and as directed by the Engr-in-Charge.
Disconnecting,rerouting,jointingafter straight through joint and Reconnecting of LT cable to LT control panel,capacitor bank ,Transformer after making foundation, complete all as specified amnd as directed by the Engr-in-Charge. Note : (i) Excavation for taking up existing cable will be measured separately. (ii) Straight through Joints as reqd will be measured separately
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 mtr in depth for laying cables and getting out in soft / loose soil for laying cable, foundation etc. for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed by Engr-in-Charge.
Surface excavation n.exe 30cm deep and averaging 15cm depth and getting out soft/loose soil
Excavation in post holes (or similar holes) each N.exc 0.5 cum getting out in soft soil , returning filling in and ramming earth or broken rubble mixedwith earth around in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good the surface.
Supplying and laying reinforced precast concrete cable cover, class LV , Type I, flat, size 50 mm x 150 mm x 40 mm in trenches for cable protection all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in c.m 1:4 all as specified.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in cement mortor 1:6 complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for hardcore of gauge exc 63 mm but n.exc 100 mm deposited, spread and leveled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces in broken stone or boulder complete all as specified and as directed by Engr-in-Charge.
M&L 100 mm thick PCC 1:3:6 type D-2 using 40 mm graded stone agg as in sub base complete all as specified and as directed by Engr-in-Charge.
M&L 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone agg as in floor finished even and smooth complete all as specified and as directed by Engr-in-Charte.
M&L for MS work as in railing, guard bars, grill conforming to Fe290 Gde E 165 complete all as specified and as diredcted by Engineer-in-Charge.
M&L Expanded metal, n.exc 4 Kg /Sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified.complete all as specified and as diredcted by Engineer-in-Charge.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, 11 to 15 mm dia complete all as specified and as diredcted by Engineer-in-Charge.
M&L for two coat of synthetic enamel paint over a coat of primer including preparation on steel surfaces of any description over 10 cm width or girth complete all as specified and as diredcted by Engineer-in-Charge.
M&L for straight through (Heat shrinkable) suitable for LT UG cable 1.1 KV including excavation and cable connection in trenches complete of following sizes:-
All as per item No 125 here- in- above but 16 to 35 Sqmm 3 1/2 Core complete all as specified and as directed.
All as per item No 125 here- in- above but 50 to 95 Sqmm 3 1/2 Core complete all as specified and as directed.
All as per item No 125 here- in- above but 120 to 185 Sqmm 3 1/2 Core complete all as specified and as directed.
Taking up old unsv HT/LT cable 70 sqmm to 120 sqmm from trenches,drain ,road or on poles for rerouting and connecting to LT control panel all as specified and directed directed
M&L for chemical earthing with pure electrolytic copper electrode earth plate 90cmx60cmx5mm duly filled with highly conductive crystalline material (CCM) and anti corrosive compound having chemical composition Bentonite40%,copper sulphate 10%, gypsom 5%, graphite 10%, Alum 5%, Zinc sulphate 10% ,Aluminium sulphate10% burried in ground by digging a bore hole of 100mm surrounded by soil friendly back fill compound non soluble in water incl connection with 32x6mmcopper earth strip exothermally joined,making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C-1 with RCC 1:2:4 type B-1,40 mm thick cover re inforced with 6mm dia MS bars 3 nos both ways with lifting hook made out of 8mm dia bar and testing on completion to achieve value not more than 0.5 ohm complete all as directed by engineer in charge.
M&L for laying reinforced concrete pipes, class NP2 of dia 100 mm, 02 Nos half round (for bottom and top) and before laying excavated area shall be leveling complete all as specified and directed by Engineer in Charge.
SHRI SWAPNAYOG ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .