Loading…
Loading…
Tender Value
₹96.1 L
EMD Value
₹1.9 L
Closing Date
24 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SRDSTECSIG
14 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Form-2, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any signaling work of PI or RRI or El or ABS or IBS/IBH involving indoor work. OR Any work of alteration in PI or RRI or El or ABS or IBS/IBH. Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30 / 40 / 60 % (as the case may be) criterion of similar nature of work. Note 2: The tenderer should be OEM or have an MOU with OEM (OEM of the El in which alteration is to be done). Tenderer will have to submit the proof of the same with the tender document.
15 conditions · 10 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
PAN Number must be attached.
Registered Office Address with contact no.
Detail of Bid Security paid, through only payment modes available on IREPS portal like net banking, debit card, credit card etc.
Mandatory undertaking regarding Employment/Partnership of Retired Railway Employees as per Clause No. 12 of Chapter-I as per Annexure- E.
Mandatory certificate to be submitted by tenderer along with tender documents as per Annexure- A.
GST Number must be attached.
Mandatory Power of Attorney to be submitted by tenderer along with tender documents as per Annexure- B.
MOA & AOA, Resolution of Board and POA, Sole Proprietorship, Notarized partnership deed with POA and latest certificate of registration with Registrar of the firms must be attached. Year of Formation / Incorporation. (As per Clause-10 of Tender Document
Upload duly filled and signed Cover Letter (Tender Form 1)
Mandatory Document Tenderer uploaded Annexure-A (1) {This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF)/Limited Liability Partnership (LLP) etc.)}of tender documents.
An undertaking by the tenderer shall be provide at the time of tender submission that the equipment shall be procured from RDSO/TEC/OEM covering supply, installation, testing, commissioning of system including after sales support required during the warranty period.
The tenderer should be OEM or have an MOU with OEM (OEM of the EI in which alteration is to be done). Tenderer will have to submit the proof of the same with the tender document.
S&T work in Connection with Upgradation of infrastructure at EMU Car Shed GZB post-merger of shed's Departure line into 4th main line between Dadri and Chipiyana Buzurg.
558-Sig-16-M-Tender-1471
558-Sig-16-M-Tender-1471
Open
Works - General
12 Months
Delhi, Delhi
₹0
₹1.9 L
24 Feb 2026
3 Feb 2026
10 Feb 2026
103 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 96,13,894.54 | ||
| — | 1.00 | — | — | ||
| Modification/Alteration in existing (ANSALDO MAKE) EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. Th e complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. Inspection: RDSO for supply portion. | — | — | — | 43,92,911 | |
| — | 24.00 | — | — | ||
| Supply of sec. cell low maintenance 2 V/ 80 AH. conforming to IRS S-88/2004 Rev-1or latest with micro porous vent plugs cum floats with inter cell connectors, nuts, bolts, washers etc. Inspection: RDSO | — | — | — | 78,346.08 | |
| — | 10.00 | — | — | ||
| Supply of QTA2 relays AC immunised plug in type DC 9 Ohm neutral track relay miniature tractive armature with 2F/1B contacts as per BRS 939A or latest amendments if any, BRS 966 Append F2, IRS- S-34 & IRS-S-23 & IRS-S-60 (as applicable). Inspection RDSO | — | — | — | 58,945.9 | |
| — | 10.00 | — | — | ||
| Supply of Relay of AC immunized plug in type style "QSPA1", DC Neutral line, slow to pick up, 24V, contacts, front and back contacts metal to carbon, complete with plug board, retaining clip and connectors conforming to BRS 933 A, IRS S 60, IRS S 34, IRS S 23 or latest (as applicable). Inspection RDSO | — | — | — | 61,132.4 | |
| — | 10.00 | — | — | ||
| Supply of Relay, AC Immune, plug-in type, Style 'QNA1', DC Neutral Line, 24V contacts, front & back contacts metal to carbon with plug board retaining clip and connectors conforming to BRS 931A, IRS S 60, IRS S34 & IRS S23 (as applicable). Inspection RDSO | — | — | — | 47,150 | |
| — | 10.00 | — | — | ||
| Relay, Non-AC Immunized, plug in type, style "QN1" DC neutral line 24VDC, 8F/8b contact, front and back contact metal to carbon with plug board, retaining clip and connector a conforming to BRS:930, IRS - S - 34-68 Adm-6 and IRS:S-23/88- Adm-1 (as applicable). The interlocking code for this unit shall be ABCDF or latest. Inspection: RDSO | — | — | — | 44,499.8 | |
| — | 2.00 | — | — | ||
| Supply of Electric point machine, non-trailable type conforming to RDSO Spec no.IRS:S.24/2002 amendment no.1 or later with the following parts (a) 220mm throw with interlocking for operation of the point as per RDSO Drg No.S-/11000 with AC immunity of 160 volt (RMS),50 HZ.(b):-Clamp point lock 60kg for BG as per RDSO Drg no. S-3395A.(c):-Switch extension Bracket ( P- Bracket) and insulation plates as per RDSO Drg.no S-3591,3592 & 3593.(d) Detector rods (Long & Short) as per RDSO Drg no.S-3596-97. (e) Drop lug as per RDSO Drg no S-3598 including all insulation and accessories Electric Point Operating Machine-IRS Type 220 mm Throw, High thrust (AC Immunity 160V AC), non-trailable to operate on 110V DC complete with Lock & Detector slides, Cable terminal Box and Clamp Lock & Ground Connections. Confirming to IRS: S 24 / 2002 & Assy. Drg. No.- RDSOS/11000 & for Motor IRS: S 37 / 82 Inspection: RDSO | — | — | — | 3,49,899.54 | |
| — | 4.00 | — | — | ||
| Supply of ELECTRIC POINT MACHINE 143 MM 143 STROKE AC IMMUNITY 400V AC COMPLETE WITH LOCK DETECTOR AND SLIDES FOR LOCK DETECTOR NON -TRILABLE TO OPERATE ON 110V DC ROTARY LOCKING WITH CRANK HANDLE UNIVERSAL TYPE AS PER RDSO SPECN. NO.IRS:S-24/2002 (AMND 1) RDSO DRG. NO S-10800 (ALT.5) WITH JUNCTION BOX TELESCOPIC. THE MOTOR WILL BE AS PER RDSO SPECN. NO. IRS: S-37/82 (AMND. 3) WITH RDSO DRG. NO. S-10910. This includes supply of Set of tools as per para 20.1 & 20.2 of RDSO SPECN.NO. IRS:S-24/2002 (AMND 1) 20.1 The following set of tools in a suitable tool box shall be supplied along with every set of eight-point machines or less. i). Hand operated square drive socket wrenches of 12.5 mm driving square (short type) as per IS: 7381 for M8, M10, M12 & M18 threads. (One 250 mm long 12.5 mm square extension bar as per IS: 7991 along with compatible Tee handle square drive as per IS: 7975 suitable for above socket wrenches shall also be provided.) ii). Open jaw wrenches (spanners) for M10, M12, M20, M24 & M33 threads as per IS: 2028. iii). Adjustable wrench. iv). Screw driver 300 mm long. 20.2 Junction box and two numbers of telescopic pipes of approved type shall be supplied as an integral part of the point machine. Inspection: RDSO | — | — | — | 2,67,843.88 | |
| — | 4.00 | — | — | ||
| Fabrication & Supply of complete set of point rodding for point machines of IRS type or its equivalent type as per. Drg. No. SA 8800-01 (Adv) or latest along with 'P' brackets and 'L' bracket required (coal Bengal for smithy work, all type of nuts & bolts and Lugs as required also to be supplied by contractor with each set), Inspection: RITES. | — | — | — | 41,777.96 | |
| — | 6.00 | — | — | ||
| Fixing, wiring, testing & adjustment of point machines as per standard practice. It also includes: - i) Fixing of switch extension 'P' bracket/'D' bracket, providing insulation for switch extension bracket, fixing ground connections, adjusting the correct opening of switches and adjusting the point machine with crank handle. ii) Wiring inside the point machine, wiring of JB with lock & key as per drawing, provided with terminal strips for cable terminations. iii) Supply & fixing of GI pipes with flange for taking cable in to point machine and junction. Box through gland/GI pipe. iv) Complete installation of point insulation, GI pipe, gland pipe, angle iron of size 75mmx75mmx10mm, channels for fixing the machine, lugs for point rodding and insulation for stretcher bar 90R/52kg/60kg as per. drg.no.SA-23172 (adv.) Alt.1 will be done by the contractor. v) Smithy and fitting work required at site for complete installation of Gauge tie plate and insulation of GTP as per approved Drg.no.NR/S&T/CON/7-6/97 and William stretcher bar (if reqd.) will be done by the contractor. Machine shall be overhauled by contractor if required. vi) This includes removal of existing gears and fixing the machine at raised level on channel as per standard practice to avoid flooding wherever required. vii) Supply of point machine, ground connections of electric point machine, Jn. box, non-insulated GTP & CTP extension plate, and stretcher bar with insulation material shall be made available by the Railways. (Inspection: Site Engineer) | — | — | — | 59,323.44 | |
| — | 24.00 | — | — | ||
| Supply and fixing of Spigot for point machines. Inspection: Consignee | — | — | — | 6,346.08 | |
| Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Inspection: Site Engineer. | — | — | — | 1,90,400 | |
| — | 2000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per approved Drg. No.NR/S&T/CON/1-1/97A. Aso as not to form a drain 0.3 Mtr. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of roots of trees & bushes. Inspection: Site Engineer. | — | — | — | 1,72,620 | |
| — | 500.00 | — | — | ||
| Excavating and refilling of trench in Rocky soil to the level of ground with rammed earth as per approved Drg. No.NR/S&T/CON/1-1/97-A1 so as not to form a drain 0.3 Mtr. Wide & 0.5Mtr. Deep on both side of the station alongside the track. This includes 50mm thick concreting work throughout in 1:3:6 ratio. All concreting material to be supplied by the contractor. It shall conform to the safe distance as per signalling and cable plan It also includes clearance of routes of trees & bushes. Inspection: Site Engineer. | — | — | — | 66,510 | |
| Supply and laying of 2nd class bricks in the trench and laying as per approved Drg. No.NR/S&T/CON/1- 1/97A as per instructions of the site Engineer. Inspection: Site Engineer. | — | — | — | 1,41,600 | |
| — | 500.00 | — | — | ||
| HDD Boring & Trenchless of 120mm Dia without HDPE pipe for laying of signalling/ Telcom / power cable under Track /Road/Culvert etc cable laying is covered separately. Inspection: Site Engineer. | — | — | — | 4,83,200 | |
| — | 900.00 | — | — | ||
| All work of horizontal boring and trenchless cabling along with supply, transportation and insertion of double wall corrugated pipe -( ISI marked) conforming to RDSO Spec no. RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc as per instruction of site engineer. by using pipe of size 120 mm outer Dia, 103.5 mm inner Dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. Inspection: RITES for DWC pipe, Execution: Site Engineer. | — | — | — | 16,16,841 | |
| — | 200.00 | — | — | ||
| Supply and fixing of G.I. pipe perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per Drg. No. (NR/S&T/CON/1. 4/97) or at ASM office / other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. G.I. pipe 75/80 mm Dia, 3mm thick. Inspection: Consignee. | — | — | — | 1,88,092 | |
| — | 5.00 | — | — | ||
| Supply of single apparatus case steel RE with 'E' type lock and key ward no.42 and handle as per Drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B. Inspection: Consignee | — | — | — | 1,25,282.55 | |
| — | 5.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of single apparatus cases of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/S&T/CON/2-7/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. Apparatus Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer. | — | — | — | 33,081.7 | |
| — | 1.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts. This includes fixing of fuses, ARA terminal and fixing and jamming of cables with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminium paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS spec., non-deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 5,633.88 | |
| — | 2.00 | — | — | ||
| Preparation of App. Case single involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminium paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS spec., non-deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 13,711.96 | |
| — | 2.00 | — | — | ||
| Preparation of App. Case to be used as battery box. (not requiring shelf and hylum of size 910x150x6mm only is reqd.). This includes fixing of fuses, ARA terminal and jamming of cables with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminium paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hylum board, salwood plank, wire and wiring material as per the IRS spec., catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 6,974.92 | |
| — | 2.00 | — | — | ||
| Supply of apparatus case steel RE half with E type lock and key ward no.42 and handle as per drg.no. RE/S&T/ALD/SK/220/82 and 221/82 with Alt.B. Inspection: Consignee. | — | — | — | 38,660.76 | |
| — | 2.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of half apparatus cases of size (670mmx760mm) and 650mm deep as per Drg.No.NR/S&T/CON/2. 8/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse sand, aggregate and anchor bolt shall be supplied by contractor. App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer. | — | — | — | 11,585.5 | |
| — | 2.00 | — | — | ||
| Preparation of App. Case half not involving wiring of relays. Preparation and fixing of Bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2-inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminium paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non-deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 7,729.62 | |
| — | 10.00 | — | — | ||
| Supply, Installation & Commissioning of maintenance free earth suitable kit as per RDSO Specification no. RDSO/SPN/197/2008 and Drg No. SDO/. /E&B/001 dated: - 19.09.2008 and Drg No. RDSO/SDO/. /E&B/002 dated: - 19.09.2008. Earthing kit consisting of earthing electrode of 17mm dia as 3m long -01 no 2 MEEB (300mmx25mmx6mm) -o1 no. 3. SEEB (150mmx25mmx6mm) -01 no 4. Earth enhancing compound - 30 kg (minimum). This includes: - Provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data Logger etc. with PVC earth wire of size 25/35 sq.mm through copper lugs of suitable size PVC earth wire shall be supplied by contractor. Note: At certain locations, it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode /pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done, for interconnection of two earth pits copper tape of size 25x2 sq.mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Inspection: RDSO for supply portion, Execution: Site Engineer. | — | — | — | 2,76,638.5 | |
| — | 8.00 | — | — | ||
| Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtr. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per Drg. No. (NR/S&T/CON/6.4/97). The soil treatment shall be done as per std. practice. The item includes provision of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earthing connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per Drg. No. (NR/S&T/CON/6. 3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection: Consignee. | — | — | — | 30,025.12 | |
| — | 1000.00 | — | — | ||
| Supply of ARA Terminal Block 25MM centre M6 terminal made of PBT as per IRS spec. No. IRS-S- 75/2006 (Rev.2) & IRS drawing No. SA- 23741A(Alt.4), SA23745(Alt.5), SA-23746 & SA- 23756(Alt.3). Inspection: RDSO | — | — | — | 79,860 | |
| — | 1000.00 | — | — | ||
| Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor. Inspection: Site Engineer. | — | — | — | 15,620 | |
| — | 2.00 | — | — | ||
| Installation of Berthing and straight DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement: - (a) Drilling of holes 7.2 mm Dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastened with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs as per Drg. No. (NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TLJBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals.This all include supply of all material by contractor except supply of TF battery charger, batteries, relays which are covered separately.(f) Commissioning of track circuits as per provision of para of IRS spec. S- 36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. Inspection: Choke & Resistance by RDSO | — | — | — | 31,711.36 | |
| — | 4.00 | — | — | ||
| Installation of Point track circuit having single point (excluding traps) DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement: - (a) Drilling of holes 7.2 mm Dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastened with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs as per Drg. No. (NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TL JBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays which are covered separately. (f) Commissioning of track circuits as per provision of para of IRS spec. S- 36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. Inspection: Choke & Resistance by RDSO | — | — | — | 1,00,845.44 | |
| — | 2.00 | — | — | ||
| Installation of Point track circuit having double point (excluding traps) DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement: - (a) Drilling of holes 7.2 mm Dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastened with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs as per Drg. No. (NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TL JBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays which are covered separately. (f) Commissioning of track circuits as per provision of para of IRS spec. S- 36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. Inspection: Choke & Resistance by RDSO | — | — | — | 52,586.2 | |
| — | 8.00 | — | — | ||
| Supply of track feed batt. charger 110VAC/2-4-6 VDC / 10 Amps as per RDSO spec. no. IRS: 89/2013 (Amd 1) or latest from RDSO approved Firm. Inspection: RDSO. | — | — | — | 38,025.36 | |
| — | 24.00 | — | — | ||
| Charging of lead acid secondary cells of 80 AH capacity as per standard charging procedure (with contractor charging equipments). All charging materials i.e. Sulphuric acid conforming to latest IRS specs and distilled water as per IRS specs will be supplied by contractor. This also includes installation of secondary batteries, their interconnection and writing work. Inspection: Site Engineer | — | — | — | 6,000 | |
| — | 10.00 | — | — | ||
| Supply of Track Lead Junction Box (TLJB) as per Drg.No.RST-11509 or TLJB latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc. (b) Each TLJB shall have two TLJB bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome plate M10 brass terminal, 50mmlong.Alongwith each TLJB , nickel TLJB chrome plated brass links(two nos.0fadequate strength for vertical linking of the terminals to be supplied. (c)HDPE pipe of size 32/35mm, 380 mm long along with two nuts for fixing on the TLJB hole. (d) The FRP stump for TLJB mounting the TLJB to be made of one TLJB meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mmX30mmX 4mm angle (1 no.) fixed at 50mm from the bottom using galvanised nuts and bolts. The TLJB and the angles TLJB for stump should come along with holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied along with TLJB drawing TLJB no. 11509. Inspection: Consignee. | — | — | — | 18,481.8 | |
| — | 5.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA-20161-66/M or latest. Inspection: RDSO. | — | — | — | 7,478.2 | |
| — | 5.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amendment 1) or latest. Inspection: RDSO. | — | — | — | 19,208.65 | |
| — | 3.00 | — | — | ||
| Supply of shunt signal position light complete with lock, unit post and surface base mounting socket 90mm Dia without holders' bulbs etc. to drg.no.23840 adv. Or latest specs.no.IRS- S-23/88 Independent post type. Inspection: Consignee. | — | — | — | 30,371.55 | |
| — | 3.00 | — | — | ||
| Casting, concreting and curing of foundations for shunt signal/ 'F' marker of size (855mmx855mm) at bottom and (711mmx711mm) at top and 750mm deep as per approved Drg. no. NR/S&T/CON/2- 1/97A. All material such as cement, coarse sand, aggregate & foundation bolts will be supplied by contractor. Inspection: Site Engineer | — | — | — | 12,780.36 | |
| — | 3.00 | — | — | ||
| Installation, erection and wiring of independent position light shunt signal/'F' marker. This includes fixing of shunt signal, surface base signal post, LED signal unit/ lenses, lamp hood and wiring of shunt unit and focussing the signal. All material such as wire, nut& bolt etc. will be supplied by the contractor. Inspection: Site Engineer | — | — | — | 4,028.01 | |
| — | 2.00 | — | — | ||
| Supply of Stop Board as per RDSO Drg No 7235/B / Block Section Limit Board/Shunting Limit Board as per RDSO Drg. No. SA2375 (Adv.). This includes Painting and retro reflective arrangement should be as per SEM. Inspection: Consignee. | — | — | — | 4,376.54 | |
| — | 2.00 | — | — | ||
| Supply of Megger 500V DC Philips or similar make. Inspection: Consignee | — | — | — | 8,517.44 | |
| — | 2.00 | — | — | ||
| Supply of Portable digital auto range multi-meter clamp type Philips, Motwani, Fluke or Rishabh make capable to measure from (0.1mv/0.01ma) AC/DC upto 50Amp (AC/DC), 600V(AC/DC) and 0.1 ohms- 40M ohms suitable for measurement of Freq., capacitance complete with Manual, leads, battery and holster etc. Inspection: Consignee | — | — | — | 17,857.02 | |
| — | 5.00 | — | — | ||
| Supply & Installation of Thermo shrink jointing kit for 6-Quad/4-Quad cable for straight through joints as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection: RDSO | — | — | — | 38,827.05 | |
| — | 1.00 | — | — | ||
| Dismantling of lifting barrier/ gate leaves complete set along with winch, wire rope, boom locking arrangements. All dismantled material to be transported and stacked in the store of SSE/Sig/GZB at GZB or Dy.CMM/SSB store depot at DLI or any other store of northern railway as per consignee. Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engineer. Inspection: Site engineer. | — | — | — | 3,475.24 | |
| — | 5.00 | — | — | ||
| Dismantling and releasing of location boxes which includes all S&T fittings of electrical and mechanical, releasing of termination boards, relays, terminals, batteries, track feed chargers and other associated fittings installed therein complete with fittings. All dismantled material to be transported and stack in the store of SSE/Sig/GZB or DY.CMM/SSB store depot at SSB/site supervisor or any other store of northern railway as per. Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Location Box). Inspection: Site Engineer | — | — | — | 3,966.95 | |
| — | 1.00 | — | — | ||
| Dismantling and releasing of S&T gears in ASM room, Battery room, relay room, equipment room, DG room (including DG sets). This include all equipments and relays, relay rack, terminal board, SM Slide frame, panel batteries, battery chargers, angle iron, etc. all materials are to be transported and stacked in the store of SSE/Sig/GZB at GZB or Dy.CMM/SSB store depot at DLI or any other store of northern railway as per consignee. (Job = Per Room). Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engineer. Inspection: Site Engineer. | — | — | — | 12,412.98 | |
| — | 2.00 | — | — | ||
| Dismantling and releasing single signal post which includes dismantling of signal fittings electrical and mechanical both wheel of sorts, GI pipe pullies, pully stakes wire run from cabin to signal posts etc. All dismantled material to be transported and stack in the store of SSE/Sig/GZB or DY.CMM/SSB store depot at SSB/site supervisor or any other store of northern railway as per. Note: - Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.1 Job= 1 Signal). Inspection: Site Engineer | — | — | — | 2,774.5 | |
| — | 470.00 | — | — | ||
| Earth work for excavation and refilling around location boxes, signals etc. where necessary including 50m lead and 1.5m lift by excavation. The earth shall be rammed including breaking of clods, levelling and dressing. The earth work around the location/junction boxes/signals shall be up to the plaster level and for width sufficient for the maintainer to attend the box both from front & back side. Inspection: Site Engineer | — | — | — | 71,017 | |
| — | 40.00 | — | — | ||
| General concrete work in cement, coarse sand and aggregate ratio 1:3:6, work scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4. Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. Inspection: Site Engineer | — | — | — | 1,40,566.8 | |
| — | 270.00 | — | — | ||
| Fabrication, Supply, Fixing of Cable Tray made of M.S. Sheet of sorts and sizes along with suitable size of MS angles/slotting angles/Clamps with painting as per requirement. Inspection by Consignee | — | — | — | 76,342.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TSIP-CYZ-1471.pdf
ATTACHMENT
Tenderdocument-1471_1.pdf Tender document 1471
ATTACHMENT
Tenderdocument-1471_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .