Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.9 L+₹17,960 (0.52%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹37.4 L+₹2.7 L (7.74%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Scan DD not uploaded in portal |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
13 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR AND MAINTINANCE OF ALL TYPES STREET LIGHTS INCLUDING ALLIED WORKS IN DOMESTIC AREA AT AF STN CHAKERI KANPUR
2020_MES_345241_1
8402/E8
Open Tender
Civil Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹98,000
20 Jul 2020
16 May 2020
20 Jun 2020
16 May 2020
13 Jun 2020
30 May 2020
60 days
Amount
Labour only for checking the serviceability of light fittings including lowering down if needed and testing of different spares / components / parts of security light fittings (T-5, HPSV,MH, LED fittings etc, any wattage/capacity) of any description and in any position, checking functioning of contactor, MCCBs and their replacement if found to be unserviceable, regular cleaning of dust & dirt deposit due to natural effects, removal of carbon deposits it any or as direction of Engr-in-Charge. Replacement of un-serviceable/ damaged /broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed. NOTES FOR SCH `A’ ITEM NO 1 :- (i) Sparesparts/componenets required to make the light fittings serviceable shall be measured and paid for separately under respective item of sch 'A'. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc. (iii) Required screws, insulating tapes, internal wiring wire , gaskets, tape insulation and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Taking down unserviceable street/security light fittings of any type,wattage and make (such as retrofit CFL, FTL, LED,HPSV/MH light fitting) from LT/HT poles and transporting from site to MES store yard for repairing in deemed to be includ in this item rate. The defective street light fittings will be repaired only at MES yard/place where over directed by Engr-in-Charge.
Supply and fixing open construction electromagnetic HPSV/MH ballast 400watt consisting of high quality silicon steel lamination with argon welding, super enemelled copper wire, vacuum impreganated with white resin, terminal block with tapping for 220/240 volts supplied including taking down and neccessary connection complete all as specified and directed. Make:- CG/ Philips/ Bajaj/ Wipro
As per item No 02 above but 250 watt.
As per item No 02 above but 150 watt.
As per item No 02 above but 70 watt
Supply & fixing Ceramic porcelain lamp holders suitable for 150 to 400 watt HPSV/MH fitting including taking down old unserviceable complete all as specified and directed.
Supply & Fixing ignitors suitable for HPSV/MH fittings (70/150/250/400W) including taking down old unserviceable complete all as specified and directed. Make:- Bajaj/ CG/ Philips/ Wipro.
Supply & Fixing MH lamp single ended 400 watt suitable for street light/flood light fitting including taking down old unserviceable complete all as specified and directed. Make :- Bajaj/ CG/ Philips/ Wipro
Supply & Fixing MH lamp single ended 250 watt suitable for street light/flood light fitting including taking down old unserviceable complete all as specified and directed. Make :- Bajaj, CG/ Philips/ Wipro
Supply & Fixing MH lamp single ended 150 watt suitable for street light/flood light fitting including taking down old unserviceable complete all as specified and directed. Make :- Bajaj /CG /Philips /Wipro
Supply & Fixing MH lamp single ended 70 watt suitable for street light/flood light fitting including taking down old unserviceable complete all as specified and directed. Make :- Bajaj/ CG / Philips / Wipro
Supply & Fix 60 watt LED lights driver, after fixing. The driver should be 140 V to 270 V universal driver with built in surge protection > 5 kV , 50 Hz +/- 3% , p.f. > = 0.95 , THD < 10% with system efficiency must be > 85 Lumens/Watt and Power efficiency >= 90% and protection IP 65 or better requirement. The driver shall comply LM-79/IS:16106 complete all as specified and directed. Make of LED lights:- various make, sample kept in GE's office.
All as item No 12 but 90 watt LED lights driver.
All as item No 12 but 100 to120 watt LED lights driver.
All as item No 12 but 250 watt LED lights driver.
Supply and fixing Electronic Ballast Capacity 2 x 24 Watts suitable for 24 Watt T-5 Lamp complete all as specified and directed. Make :- WIPRO/ BAJAJ/ CG/ Havells.
Supply and fixing T-5 Lamp 24 Watt complete all as specified and directed. Make :- WIPRO/ BAJAJ / CG/ Havells.
Supply and fixing T-5 lamp Lamp Holder suitable for 24 Watt Lamps complete all as specified and directed.
Supply and fixing LED bulb 15 Watt suitable for Post top lantern complete all as specified and directed. Make :- WIPRO/ BAJAJ/ CG/ Havells.
Supply and fixing LED bulb 9 watt, retrofit type complete all as specified and directed. Make : Havells/ Wipro/ Bajaj/ Phillips
Supply and fixing LED bulb 40 watt, retrofit type complete all as specified and directed. Make : Havells/Wipro/ Bajaj/Phillips
Supply and fixing Batten holder for retrofit universal type as complete all as specified and directed. Make-Wipro/ Bajaj/Phillips
Supply and fixing in replacement for automatic street light switch using nature switch for automatic switching of street lights base on LUX level of Natural light. The infrared sensor based nature switch alongwith suitable power cotactors and MCBs (Input-Output) should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proff, termite proof and FR grade thermoplastic polycabonate enclosure conforming to IP-66 protection class 2. The power contactor, MCB and copper circuit wiring (min 10 Sqmm) should suitable enough to take 3 phase load of 8kW, contactor rating 25-32 Amps per phase, MCB(SP) rating 32 Amps (3 Nos) complete all as specified and directed. Make: Nature Switch - Kakatiya Energy System Pvt Ltd/Bajaj/Healer. Power Contactor: BCH/L&T/Schneider or equivalent. MCBs - Schneider/L&T/BCH or equivalent. Circuit wiring cable - Finolex/Polycab/RR Cable or equivalent
Repair/maintenance of timer switch assembly of any type and make after dismantling the same from pole, detecting fault, rectifying the same, testing and refixing in the existing position complete all as specified and directed. NOTE :- Parts will be measured and paid for separately.
Supply & Fixing in repair street light Lexic Power Timer contactor, 04 pole, 32 Amps complete all as specified and directed. Make :- Legrand, L&T, ABB.
Supply & Fixing in repair street light Lexic Power Timer contactor, 02 pole, 32 Amps complete all as specified and directed. Make :- Legrand, L&T, ABB.
Supply & Fixing in repair street light Lexic Power Timer contactor, 04 pole, 40 Amps complete all as specified and directed. Make :- Legrand, L&T, ABB.
Supply & Fixing in repair street light Lexic Power Timer contactor, 02 pole, 40 Amps complete all as specified and directed. Make :- Legrand, L&T, ABB.
Supply & Fixing in repair street light Lexic Power Timer contactor, 04 pole, 63 Amps complete all as specified and directed. Make :- Legrand, L&T, ABB.
Supply & Fixing in repair street light Lexic Power Timer contactor, 02 pole, 63 Amps complete all as specified and directed. Make :- Legrand, L&T, ABB.
Supply and fix in repair three pole Power contactor ML4 coil voltage 240 V testing complete all as specified and directed. Make - L&T, Legrand, ABB, Havells.
Supply & fixing in repair of automatic street light control switch using infrared sensor based Nature Switch for automatic switching of street lights complete all as specified and directed.
Supply & fixing in repair Automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/sun set by setting date, time and degree of longitude and latitude without separate light sensors complete all as specified and directed. Make :- Legrand, L&T, ABB.
Supply and fixing in repair Automatic operation street light timing switch having lighting control (ON-OFF) through Dail type timer switch (24 Hours) complete all as specified and directed. Make :- Legrand, L&T, ABB.
Supply & Fixing in repair SPN, DBs for lexic MCB with SPN MCB 63 Amp, 10KA, 240V complete all as specified and directed. Make :- Havells, L&T, Legrand, ABB.
S&F in repair MCB 10 KA, 230 Volts conforming to IS-8828: 1926, IEC-898 : 1995 rupturing capacity of the rating SP 6-32 Amps complete all as specified and directed. Make : L&T, Havells, Legrand.
S&F in repair MCB 10 KA, 415 Volts conforming to IS-8828: 1926, IEC-898 : 1995 rupturing capacity of the rating TPN 32/40 Amps complete all as specified and directed. Make : L&T, Havells, Legrand.
S&F in repair MCB 10 KA, 415 Volts conforming to IS-8828: 1926, IEC-898 : 1995 rupturing capacity of the rating TPN 63 Amps complete all as specified and directed. Make : L&T, Havells, Legrand.
S & F in repair street light junction box (225x295x122mm) comprising four nos aluminium bus bars of suitable size mounted on epoxy insulators with holes for incoming and outgoing cables, cable gland suitable for pole mounted outdoor type having IP-66 protection complete with FI clamp 40 x 4mm with nuts, bolts & washers including one MCB SP 10 Amp, 10KA and provision for inserting copper wires complete all as specified and directed. Make:-Sintex, Rittal, Hensel.
S & F in repair street light junction box (225x295x122mm) comprising two nos aluminium bus bars of suitable size mounted on epoxy insulators with holes for incoming and outgoing cables, cable gland suitable for pole mounted outdoor type having IP-66 protection complete with FI clamp 40 x 4mm with nuts, bolts & washers including one MCB SP 10 Amp, 10KA and provision for inserting copper wires complete all as specified and directed. Make:-Sintex, Rittal, Hensel.
Supply & Fixing Fire retardant low smoke (FRLS) PVC insulated unsheathed multi stranded two core copper conductor 1100 volts grade confirming to IS : 694/1990 of size 2.5 Sqmm fixed street light terminal to over head conductor of suitable length complete all as specified and directed.
S&F PVC insulated wire copper conductor 3 core 2.5 Sqmm connected with street light to junction box complete with suitable FI clamps complete for steel tubular pole all as specified and directed.
S&F PVC insulated wire copper conductor 3core 2.5 Sqmm complete with PVC rigid conduit medium grade 20 mm bore including FI clamp 25X3 mm suitable for steel tubular LT pole complete with nut, bolt & washer fixed at a distance not less than 2.5 Mtr centre to centre all as specified and directed.
Material and Labour in repair of post top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distirbution, spun aluminium landscape luminaire with high power LED as light source light Fitting with LED 35 Watts including and accessories complete incuding cable connector, PCC work & all type of fixing arrengement complete all as specified and directed. Make: Havells (Cat No RUBYPT35WLED757PSYMTOPC) or equivalent Philips, Wipro.
Supply and fixing in repair for Integral LED aviation light luminaires comprising aluminium housing, with polycabonate enclosure, 302 LED are provided complete all as specified and directed. Make : Bajaj (cat No BGAV 302) or quivalent philips, wopro.
Supply and fixing Energy saving & Enviroment friendly LED street light fittings made out of pressure die cast anodized alluminium housing having capacity 60 watt. To be achieve B1 class road illumination as per IS: 1944 and as per national lighting code by using each LED >1W and < 3W , LED Chip Efficiency >= 135 Lumens/Watt , CRI > 70 , CCT 5000K to 6500K with LED Lifespan at 70% of light output > 50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection > 5 kV , 50 Hz +/- 3% , p.f. > = 0.95 , THD < 10% with system efficiency must be > 85 Lumens/Watt and Power efficiency >= 90% and overall IP protection IP 65 or better. The LEDs shall comply LM-80 / IS 16105 Test report , Driver & Luminaire shall comply LM-79/IS:16106 complete all as specified and directed. Make of Luminaire : Havells, Philips, Wipro
All as per item No 46 but capacity 90 watt.
Supply and fixing in repair unserviceable 100 watt LED flood light with high luminus efficacy, protected to IP65 with front toughened glass, with all necessary accessories required effective range including necessary mounting arrangement such as flat iron clamps, nuts, bolts & washers etc complete all as specified and directed. Make : Havells/ Philips/ Wipro
All as per item No 48 but LED flood light 120 watt.
All as per item No 48 but LED flood light 250 watt.
Supply and fixing in repair of LED Bush and spike lighting in precision die cast aluminium housing designed 9 W LED with high quality toughened glass in IP65 Protection, including necessary wiring, fixing arrangement like, clamp, nut, bolt, washer etc. complete all as specified and directed. . Make: Crompton/Havells/Phillips
Material and labour in repair for mounting bracket made out of galvanized iron medium grade of 50 mm bore of pipe bended into required shape and size of 1.5 mtr including necessary Flat iron clamps made out of 32x6mm flat iron, nuts, bolts & washers suitable for PCC pole/steel tublar pole/on wall and painting of clamps, brackets etc including taking out old unserviceable brackets complete all as specified and directed.
Material and Labour in repair of Garden light Fitting Integral Bollards decorative luminaire energy saving environmental friendly, long life aesthetically designed aluminium landscape luminaire diffused lighting with high power LED as light source 8W 4000K(500mm) and accessories complete incuding cable connector, MS shunken box & bakelite sheet of size 7"x4", PCC work & all type of fixing arrengement complete all as specified and directed. Make Philips (IP 65, IK 10 bollard) Cat No. BCP151LED150/WWPSU220-240V7043 or equivalent Havells/ Wipro.
Material & Labour in repair for service cable of PVC insulated unsheathed weather proof twin core aluminium solid conductor 6 Sqmm for street light service cable complete all as specified and directed. Make:- Havells/ Polycab./ finolex
All as per item No 54 but cable size 10 Sqmm.
All as per item No 54 but cable size 16 Sqmm.
Taking down/ getting out carefully old serviceable/ unserviceable LT under ground cable from trench/ floor or fixed on walls or laid in duct/ pipe, any size and core, kept in safe custody for reuse and re-laying the same serviceable cable after fault rectification in existing position with supply and fixing connecting materials such as thimbles, lugs, nuts, bolts and washers complete all as specified and directed. For 10 sqmm, 2 core to 25 sqmm, 3.5/4 core
All as per item No 57 but 50 sqmm, 3.5 core to 70 sqmm, 3.5 core
Re-laying only old seviceable cable retreived under relevent item of BOQ from 10 Sqmm, 2 core to 50 Sqmm, 3.5/4 core complete all as specified and directed.
Re-laying only old seviceable cable retreived under relevent item of BOQ above from 70 sqmm, 3.5 core to 120 sqmm, 3.5 core complete all as specified and directed.
Supply & Laying jointing, testing and commissioning LT XLPE PVC sheathed armoured LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, induct, on poles, in trenches etc including taking down / getting out of following sizes complete all as specified and directed. Make:- Havells/ finolex/ Polycab.. Note:- The rate of termination and connecting of cable including provinding suitable size and nos of lugs by crimping as directed and specified shall be deemed to be included in the item rate. For 70 Sqmm, 3.5 core.
All as per item No 61 above but 50 Sqmm, 3.5 core.
All as per item No 61 above but 35 Sqmm, 3.5 core.
All as per item No 61 above but 25 Sqmm, 3.5/4 core.
All as per item No 61 above but 16 Sqmm, 4 core.
All as per item No 61 above but 16 Sqmm, 2 core.
Excavation in truches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete all as specified and directed.
M & L Sand cushioning to UG cables 8cm deep before laying of cable and 15 cm deep over the cable including spreading, leveling, ramming complete all as specified and directed. Note :- Punned thickness only will be considered for payment.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of following sizes including dismantling and taking down existing pipe complete all as specified and directed. For 80mm bore
All as per item No 73 above but 50mm bore
All as per item No 73 above but 40mm bore
M & L for boring in any type of soil under road 1.5 Mtr below the top surface of road complete for passing through 40mm to 80mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE :- Pipe will be measured and paid for separatily. Any damage to existing cables of any type will made good by the tenderer without any extra payment.
M & L for Straight through joint kit Heat shrinkable type suitable for XLPE under ground cable of size 10 to 16 sqmm x 2/4 core all complete all as specified and directed. Make : Raychem / RPG / 3M
All as per item No 77 but of size 25 to 50 Sqmm x 3.5/4 core.
All as per item No 77 but of size 70 to 120 Sqmm x 3.5/4 core.
Supply and errecting steel tubular pole swaged type 9.0 Meter long, type 410 SP-31, IS-2713 marked complete with M&L for mild steel base plate (fillet welded to poles), pole cap/final taper plug, bolts, nuts, washers etc. Painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing on exposed surfaces and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of blue & white colour starting with white colour (each band of 30cm wide) by two coat of synthetic enameled paint up to 1.5 m height including dismantling taking out old unserviceable pole complete all as specified and directed.
M & L for PCC (1:3:6) type C2 using 40mm graded stone aggregated as in foundation, filling and mass concrete using necessary form work complete all as specified and directed.
PCC (1:2:4) type B1 using 20mm graded stone aggregate as in coping/plinth of pole, finish the exposed surface even and smooth without using extra cement including necessary form work etc complete all as specified and directed.
Scrapping, cleaning, and preparation of steel tubuler pole (9 mtr long) steel fitting complete and M & L for painting by one coat of aluminium paint after preparation of the steel surfaces including painting to pole with two coat blue & white paint in strap alternatively all round the poles. Hight of the strap shall be 30cm and Nos of strap shall be 05 Nos complete all as specified and directed.
As per item No 83 above but steel tubuler pole 11 mtr long.
Triming of tree branches any type & size to clean the route of HT/LT over head lines arround the 3 Mtr from the external conductors including removing the cut branches from site and depositing at places complete all as specified and directed.
S&F in replacement of MCCB ,4pole, 415 Volt grade, AC 63Amp 25KA and Ics =100% of Icu with adjustable thermal release including taking down old unserviceable MCCBs complete all as specified and directed.
All as per item No 86 above but 100 Amp.
All as per item No 86 above but 160 Amp.
Supply, fixing, installation and testing LT pannel out door (Kiosk type) type, wheather & vermin proof MS sheet housing 3.15mm thick, double door front & rear openable type mounted on 50 X 50 X 6mm to cover all corner and standing legs (min 75cm) of angle iron work, with coloured horizontal Tinned aluminium bus bar 4 pole, mounted on insulators of rating 200 Amps, one MCCB, 4 pole 100 Amps, 25 KA 415 volts at incoming supply. The panel size not less than 600x450x300mm with cable gland, duly powder coated, locking arrengement complete and including grouting in PCC block of suitable size complete all as specified and directed. Make- Havells/ Legrand/ ABB.
Supply and fixing on wall MCCB 415 Volts 63 Amps capacity , Four pole with Sheet steel enclosure for sutable size of MCCB with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands and fixing arrengement on pole/wall ,PCC work including necessary flat iron clamps with nuts, bolts & washers (Powder Coated) complete all as specified and directed.
Supply and fixing on wall MCCB 415 Volts 100 Amps capacity , Four pole with Sheet steel enclosure for sutable size of MCCB with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands and fixing arrengement (Powder Coated ) on pole/wall ,PCC work including necessary flat iron clamps with nuts, bolts & washers complete all as specified and directed.
Material and Labour in repair of post top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distirbution, spun aluminium landscape luminaire with high power LED as light source light Fitting with LED 40 Watts including and accessories complete incuding cable connector, PCC work & all type of fixing arrengement complete all as specified and directed. Make Havells (cat part No ENDURASPRING6PT35WLED740PSYMTOTG) or equivalent Philips,Wipro.
M&L for cutting of crawles along the electric pole of any type and height arround the 2 Mtr from the pole including removing the crawles from site and depositing at places complete all as specified and directed.
M&L for aluminium conductor steel reinforces (ACSR) any size as per site requirement as directed straining properly on insulator and binding with aluminium tap/ binding with connectors, jumpers etc including taking down old U/S conductor complete all as specified and directed.
M&L for re-stringing / tightening of ACSR conductor & GI earth wire of any size of LT over head line after removing bring at insulators on existing poles duly straining properly binding with extra aluminium binding wire to insulators, in each span having 2/4 conductor complete all as specified and directed.
M&L for pin type, porcelain, vitreous, white or green insulator (LT), 100mm height and 65mm dia, 1100 volts grade including one galvanised MS spindle, two GI washer and one GI nut complete including taking down old unserviceable insulators complete all as specified and directed.
M&L for sackle type, porcelain, brown, white or green insulator for working pressure1100 volts grade of 90mm dia and 75mm height including galvanised MS strap of 31mm x 3mm size, 12mm dia insulator bolts, washers and nuts including taking down old unserviceable insulators complete all as specified and directed.
S&F stay assemblycomprising of 7/10 SWG galvanised stay stranded wire of required length fixed to pole with and including flat iron clamp, bolts, nuts and washers, galvanised 16mm dia, 400mm long stay bow with 16mm dia 180cms, long stay rod with threaded ends, GI nut & washers GI stay plate 230x230x6mm thick plate 2 Nos thimble, MS clamp made out of 50x6mm flat iron, loop insulator, 90mmx140mm dia hole, 25mm porcelain complete all as specified and shown in electrial plate N0 1 of SSR Part- I including PCC & taking out old unserviceable stay assembly complete all as specified and directed.
M&L for cross arms of MS angle or channel iron including flat iron clamp with bolt, nut & washers drilling for bolts in any shape or size as indicated or directed and including painting with one coat of red oxide primer and two coats of aluminium paint before fixings and and one coat of aluminium paint after fixing including taking down old unserviceable complete all as specified and directed.
M&L for PVC Line separator (Spiral type) for overhead conductor 2 way complete all as specified and directed.
M&L for PVC Line separator (Spiral type) for overhead conductor 4 way complete all as specified and directed.
M&L for shifting of street light pole of any size & height to not more than 5KM distance and erecting (PCC 1:3:6 type C2) it in ground with proper coping (PCC 1:2:4 type B1) and reducing size of pole by cutting it complete all as specified and directed.
Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected by GI earth strip of size 32 x 6mm thick, soldered and revetted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I.
Ashirwad Contractor and Supplier
PAWAN COOL CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .