Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.2 LAccepted-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹28.5 L+₹5.5 L (24.1%)Rejected-Finance | 2 | Rejected-Finance Not Lowest bidder | |
| 3 | 3₹38.2 L+₹15.3 L (66.5%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | 3 | Rejected-Finance Not Lowest bidder | |
| 4 | 4₹41.7 L+₹18.7 L (81.5%)Rejected-Finance | 4 | Rejected-Finance Not Lowest bidder |
Tender Value
₹26.9 L
EMD Value
₹53,800
Closing Date
14 Sept 2021, 6:00 pmClosed
GE (AF) PALAM, DELHI CANTT-10
GE (AF) PALAM, DELHI CANTT-10
GENP-32/2021-22 REPAIR/REPLACEMENT OF EXTERNAL WATER SUPPLY PIPE LINES, PUMPS, BORE WELLS, DG SETS AND VOLTAGE STABLISERS AT OLD/NEW PINTO PARK AREA AND NC DSC PUMP HOUSE UNDER GE AF STN PALAM, DELHI CANTT-10
2021_MES_468082_1
GENP-32/2021-22
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (AF) PALAM, DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹53,800
Yes
27 Sept 2021
14 Aug 2021
15 Sept 2021
14 Aug 2021
14 Sept 2021
31 Aug 2021
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth in loose/soft soil, getting out and leveling the bottom surface to required gradient for laying of water supply mains complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth in hard/dense soil/ hard standing/ metallic road getting out and leveling the bottom surface to required gradient for laying of water supply mains all as specified and directed by Engineer-in-Charge.
Returning, filling in, including levelling watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil to a distance not exc 50mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections of size 15 mm bore dia including cleaning for refixing or removal complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 5 here-in-before but of size 20mm bore dia.
All as per srl item No 5 here-in-before but of size 25mm bore dia.
All as per srl item No 5 here-in-before but of size 40mm bore dia.
All as per srl item No 5 here-in-before but of size 50mm bore dia.
Laying and refixing old GI steel tubing 15mm bore dia in new or old position on walls, ceiling, floors ,trench etc. and including new ISI marked fittings. Complete all as specified and directed by Engr-In-Charge.
All as per srl item No 10 here-in-before but of size 20mm bore dia.
All as per srl item No 10 here-in-before but of size 25mm bore dia.
All as per srl item No 10 here-in-before but of size 40mm bore dia.
All as per srl item No 10 here-in-before but of size 50mm bore dia.
Supply. laying & testing steel water tubing, medium grade, galvanised of size 15 mm bore dia, ISI marked with and including ISI marked fittings such as tees, bends elbow reducer, unions, clamps etc fixed on Wall / laid in trench/roof (with proper clamping / strap arrangements ) complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 15 here-in-before but size 20mm bore dia.
All as per srl item No 15 here-in-before but size 25mm bore dia.
All as per srl item No 15 here-in-before but size 40mm bore dia.
All as per srl item No 15 here-in-before but size 50mm bore dia.
Taking up or down cast iron water mains (including all fittings), with spigot and socket ends including burning out lead joints and recovering lead of size 80mm bore dia complete all as specified and directed by Engineer-in-Charge.
All as per item No 20 here-in-before but of size 100mm bore dia.
All as per item No 20. here-in-before but of size 150mm bore dia.
All as per item No 20 here-in-before but of size 200mm bore dia.
Laying and refixing old 80 mm bore dia CI/DI pipes in new or old position after cleaning thoroughly and removal of all blockages by using splitted bamboo/steel rod effectively of pipe incuding rubber titan/gasket joint/ lead joint etc. Complete all as specified and directed by Engineer-In-Charge. Note Exavation, lead joint, CI fitting etc shall be measured and paid separately.
All as per srl item No 24 here-in-before but 100mm bore dia.
All as per srl item No 24 here-in-before but 150mm bore dia.
All as per srl item No 24 here-in-before but 200mm bore dia.
Supply & Laying, jointing , testing Cast iron pipe with spigot and socket end centrifugally cast, class LA, tyton joints conforming to IS-1536-1976 laid in trenches of the 80mm bore pipe as specified and directed by Engr-in-charge.
All as per srl item No 28 here-in-before but of size 100mm bore dia.
All as per srl item No 28 here-in-before but of size 150mm bore dia.
All as per srl item No 28 here-in-before but of size 200mm bore dia.
Material & labour for CI special fittings of any size, any type ISI marked as required at site such as bends (any type, radius and angle),Taper any type, (straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch. "Y" junction, double branch, cross (all socket or socket and spigot), collar, caps and plugs upto 150mm bore etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing CI special fittings of any size, any type ISI marked as required at site such as bends, Tees, short pieces, tapers, collers, junctions etc for spigot and socketed/flanged pipe above 150mm bore but up to 300mm bore complete all as specified and directed by Engr-in-Charge.
M&L for run lead joints for CI pipe 80mm bore dia spigot & soketed/CI fittings including all jointing material required at site complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 34 here-in-before but of size 100mm bore dia.
All as per srl item No 34 here-in-before but of size 150mm bore dia.
All as per srl item No 34 here-in-before but of size 200mm bore dia.
S&F in replacement gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipe or for union and fixed complete for size 50mm bore dia complete all as specified and as directd by Engineer-in-Charge.
All as per srl item No 38 here-in-before but of size 40mm bore dia.
All as per srl item No 38 here-in-before but of size 25mm bore dia.
All as per srl item No 38 here-in-before but of size 20mm bore dia.
All as per srl item No 38 here-in-before but of size 15 mm bore dia.
Material & labour for S&F in replacement including jointing and testing of cast iron sluice valve, class PN-1.6, ISI mark, flanged ends drilled having stainless steel /brass spindle with cast iron wheel at top complete with nuts, bolts,washers and gaskets including taking out old unserviceable sluice valve for the 80mm bore size complete all as specified and directed by Engr-in-charge. Make: Kartar/ Kirloskar/Bir/L&T
All as per srl item No 43 here-in-before but of size 100mm bore dia.
All as per srl item No 43 here-in-before but of size 150mm bore dia.
All as per srl item No 43 here-in-before but of size 200mm bore dia.
Material and labour for Construction of valve pit chamber having internal dimension 120 cm x 120 cm x 120 cm (internal height) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick, brick walls 23 cm thick in CM (1:4), 10 mm thick rendering all around the brick work in cm (1:6) PCC (1:2:4) type B1 for 100mm thick coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS sheet cover with handle and locking arrangement with and including 50 mm pad lock with double key arrangement, MS frame made out of 40 x 40 x 6 mm size angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of metal primer including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition / dismentling of existing valve chamber complete all as specified and directed by Engineer-in-Charge.
Material and labour for Construction of valve pit chamber having internal dimension 90 cm x 90 cm x 90 cm (internal height) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick, brick wall 23 cm thick in CM (1:4), 10 mm thick rendering all around the brick work in cm (1:6) PCC (1:2:4) type B1 for 100mm thick coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS sheet cover with handle and locking arrangement with and including 50 mm pad lock with double key arrangement, MS frame made out of 40 x 40 x 6 mm size angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of metal primer including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition / dismentling of existing valve chamber complete all as specified and directed by Engineer-in-Charge.
M & L for augering of holes in true horizontal position under road (by trench less method) by means of mechanical rig covering in route up to 1.5 mtr deep and not exceeding 30mtr long for passing the water pipe lines of up to 150mm bore complete all as specified and directed by Engineer-in-Charge.
M & L well cap in replacement with housing clamp for upto 300 mm dia bore pipe in two pieces having 80 mm dia hole in centre with external braket of flat iron of size 100X6 mm thick complete with nuts, bolts and washers etc including welding painting etc including taking down old unserviceable well cap and depositing to MES store yard complete all as specified and directed by Engineer-in-Charge.
Labor only for cauclking in leaking of lead joints upto 200mm bore pipes, including excavation, lead and spun required for the same and making good surface to existing and dressing complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cleaning internal portion of stone masonry/RCC underground sump including removing fine sand/silt deposited inside the underground sump with the help of wire brushes and removing any fungus formation inside the tank, removing the waste as directed and applying caustic soda solution and one coat of lime wash internally and one coat of snocem externally including writing work with one coat of synthetic enameled paint as per colour code for inlet/outlet /Overflow/washout CI/GI pipes marking flow of water on pipes including painting/writing of letters of (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank. Complete all as directed by Engineer-in-charge for the 50,000 Glns capacity. NOTE:- (i) MAP Pump house Pinto Park 01 Nos (iI) Old Pump house Pinto Park 01 Nos (iii) Basant Nagar pump house 01 Nos (iv) NC DSC Pump House
Material and labour for cleaning internal portion of stone masonry/RCC over head reservoirs including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste as directed and applying caustic soda solution and one coat of lime wash internally and one coat of snocem externally including writing work with one coat of synthetic enameled paint as per colour code for inlet/outlet /Overflow/washout CI/GI pipes marking flow of water on pipes including painting/writing of letters of (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank. Complete all as directed by Engineer-in-charge for the 1,00,000 Glns capacity. NOTE:- (i) Old Pump house Pinto Park 01 Nos
All as per srl item No 53 here-in-before but 50,000 Glns capacity. NOTE:- MAP Pump house Pinto Park 01 Nos
Surface dressing in hard/dense soil,not exceeding 15cm deep for cleaning the area by cutting the unwanted bushes/vegetation growth in and around the area of installation/around the valve pit chamber/along the pipeline routes if reqd etc all as specified and directed by Engr-in-charge. Note :- Area cleaned/dressed will be meausred once only
Supply and fixing GI dead plate/ flanged with jointing material like packing, nuts & bolts after cutting existing necessary fiittings such as tees,bend including necessary exacavation required at site upto order of (3 mtr x 2 mtr x 2 mtr ) complete all as specified and directed by Engr-in-charge.
Material and labour in replacement of insulated rubber chequered sheet of size 2.00 x 1.00 mtr not less than 19mm thick all as specified and directed by Engr-in-charge.
Supply and fix in replacement Digital water level Indicator Device type -DDS -6 , digit display 150 mm size, direct display in digit , 230 volts Ac ,50 Hz suitable for upto 10 Mtrs , Over head tank , Alarm for upper and Lower Level Pre -adjustable , Temperature Range -5 degree C to 50 degree C , Humidity upto 95% RH , Reset push switch for silent the Alarm with ON/OFF Operation system including 4 core 0.5 sqmm copper cable all as directed by Engineer -in- charge .Make :- SECO/Universal/Siemen.
Supply and fixing in replacement of CI NRV of 150mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete all as specified and directed by Engr-in-charge.Make:- Kartar/Kirloskar/Bir
Supply and fixing in replacement of CI NRV of 80mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete all as specified and directed by Engr-in-charge Make:- Kartar/Kirloskar/Bir.
Supply and fixing in replacement of CI NRV of 100mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete all as specified and directed by Engr-in-charge Make:- - Kartar/Kirloskar/Bir
Supply and fixing in replacement of CI foot valve of 150mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size complete all as specified and directed by Engr-in-charge.Make:- Kartar/Kirloskar/Bir
Supply and fixing in replacement of CI Foot valve 100mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size complete all as specified and directed by Engr-in-charge.Make:- Kartar/Kirloskar/Bir
Supply & fixing in replacement of valve pit cover (Including all PCC Work for fixing) made out of MS frame 40x40x6mm thick angle iron with and including 8mm thick MS top cover with handle and locking arrangement and painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed by Engineer-in-charge.
Supply on ALTOCH GP high strength Granular disinfectant for chlorination of water in 45 Kg PVC drum. Make :- puri chick, BM Aquatec Pvt Ltd.
Disconnectiong existing defective electric motor of any make upto 30 to50 HP from electric mains by isolating the naked connections, removing from foundation by unscrewing the nuts, bolts etc, dis-couple from pump etc opening of motor for inspection in presence of Engr-in-Charge & carry out minor repairs at site re-assembling the motor after repair, refixing in position re-connecting same as prior to removing from foundation including replacement of nuts, bolts washers if necessiates of suitable size, testing and commissioning complete all as specified and directed. Note :- (a) Replacement of minor parts included this item. (b) In case of repairs not possible at site, the motor shall be shifted to contractor’s wksp and cost of shifting to wksp and back to site included in the item rates. (c) Replacement of windings, Shaft and bearings to be measured separately.
All as per item No.66 above but capacity 15 to 25 HP.
All as per item No. 66 above but capacity upto 5HP of any type & size.
Taking out old unserviceable/burnt copper winding of motors capacity up to 30 to50 HP (defective motor taken out in item No. 66 above) and material and labour for rewinding of electric motor of capacity up to 40 to 50 HP, 3 Phase with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge, all as specified and as directed by Engr-In-Charge.
All as per item No 69 here in before but upto 15 to 25 HP, three phase, of any type & size. (motor obtained as per sl no 67 above)
All as per item No 69 here in before but upto 5 HP, three phase, of any type & size. (motor obtained as per sl no 68 above )
Taking out unserviceable terminal plate with connector and outer cover of elect motor of any make, type upto 50 HP capacity and supply & connect, testing terminal plate with connector same as per existing complete all as specified and as directed Engr-in-Charge.
M/L for replacement of Ball bearing of the electric motor upto 30 tO 50 HP 415 Volt as opened in item No 66 here in before complete all as directed. Make: SKF/TATA/NBC.
M/L for replacement of Ball bearing of the electric motor upto 15 to 25 HP 415 Volt as opended in item No 67 here in before complete all as directed. Make: SKF/TATA/NBC.
M/L for replacement of Ball bearing of the electric motor upto 5 HP 3 phase / single phase as opended in item No 68 here in before complete all as directed. Make: SKF/TATA/NBC.
M/L for replacement of MS Shaft of the electric motor upto 5 HP 440 Volts in repairs dismanteled under item No 68 here in before complete all as directed. .
M/L for replacement of MS Shaft of the electric motor upto 50 HP 440 Volts in repairs dismanteled under item No 66 & 67 here in before complete all as directed. .
Taking out defective pump of any type, any make upto 30 to 50 HP by unscrewing the foundation bolts, disconnecting from water connection, and disconnecting from electric motor, opening for inspection in presence of Engr-in-Charge and carry out minor repair at site, in case major repair/replacement of parts not possible at site, the pump shall be shifted to contractor's workshop on his own cost, and re-fixing, re-connecting in position, testing and commissioning complete including replacement of nuts bolts washers ass as specified and as directed by Engr-in-charge.Note :- (a) Replacement of parts included this item. (b) In case of repairs not possible at site, the motor shall be shifted to contractor’s wksp and cost of shifting to wksp and back to site included in the item rates. (c) Replacement of windings, Shaft and bearings to be measured separately.
All as per item 78 above but 15 to 25 HP
All as per item 78 above but upto 5 HP
M&L for replacement of unserviceable/defective mild steel shaft 5 TO 50 HP centrifugal pump set of any make Complete all as specified and as directed. Note:- pump taken out in item 78, 79 & 80 here in before.
All as per items 81 here in before but ball bearing including greasing etc.
Disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts and taking out the submersible pump set from the well including column pipes, and submersible cable, disconnecting the pump and motor opening the pump and motor to locate the faults in presence of Engineer-in-Charge, and carry out necessary repairs as directed including transporting to workshop, re-assembling the same after repair, taking down to the well, including column pipe of any dia, 10 ft long, and submersible cable, which have been taken out, re-connecting all electrical and water connections as per existing complete testing and commissioning including new packing materials, nuts, bolts, washers of suitable size all as specified and as directed.Note :- (a) Replacement of parts included this item. (b) In case of repairs not possible at site, the motor shall be shifted to contractor’s wksp and cost of shifting to wksp and back to site included in the item rates. (c) Replacement of winding to be measured separately.
Taking out old unserviceable/burnt winding from the submersible 3 phase motors up to 10 HP capacity and M& L for rewindinig the same with insulated winding wire as per existing gauge complete including transportation to and fro and as approved by E-in Charge and testing after repair all as specified and as directed.
Supply and fixing in replacement column pipe 80mm dia bore made of meduim grade GI pipe, 10 feet length both ends flanged & drilled including cutting of groves for submersible cable and fabrication etc.
Supply and fixing Auto timer clock as per existing complete all as specified and directed
Supply and fixing of single phase preventor VSP-2 / VSP-1 complete all as specified and directed by Engr-in-Charge. Make : Minilac/ L &T/ Lagrand
Supply and fixing of MCB TP 32 to 63 Amps as per site requirement complete all as specified and directed by Engr-in-Charge. Make: Sehnider/Legrand
Disconnecting electrically, the switch change over of any type as per site requirement and supply & fixing and connecting change over switch MCB TPN 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material complere all as specified and directed. Make:- Havells/Standard./Legrand
All as per items No.89 above but 125 Amp 440 volts.
All as per items No. 89 above but 100 Amp 440 volts.
Disconnecting, electrically,isolating the existing unserviceable MCCB TP of any make and capacity and Supply, fixing, connecting, testing and commissioning MCCB TP, 440 volts fixed in existinig panel including necessary modification for new MCCB TP, 250-400 Amp capacity breaking capacity upto 50 KA conferminig to relevant IS including all joining and connecting material all as specified. Make:- Schnider//L&T/Havels
All as per item No. 92 here in before but 200 Amps breaking capacity 35 KA
All as per item No. 92 here in before but 125 Amps breaking capacity 16 KA
All as per item No. 92 here in before but 100 Amps breaking capacity 25 KA
All as per item No. 92 here in before but 63 Amps breaking capacity 16 KA
All as per item No. 92 here in before but 32 Amps breaking capacity 16 KA
Supply and fix in replacement control panel for submersible pump , Automatic phase sequence phase correct will automatically correct input reverse phase & also protect against single phasing voltage unbalancing low voltage ,high voltage with time delay 3 to 5 seconds and automatic digital timer switch will automatically ON/OFF the motor starter as per time setting and automatic motor protector will protect up to Submersible pump/motor Terminal against dry running , under & over current . unbalancing built in CT's . capacity up to 10 HP Make - SECO/ L&T/Legrand
Supply connecting testing and commissioning submersible cable in replacement with copper conductor, stranded of size 4 sqmm 3 core complete including dismantling the old unserviceable cable all as specified and as directed. Make Plaza/Kalinga/Havels
All as per item No 99 here in before but 6 sqmm, all as specified and as directed.
M&L for Flushing of existing borewells of size 300mm dia, depth upto 200 mtr with drilling compressor including surging and flushing the bore at a pressure of 7 kg/ sqcm complete with compressed air and flushing the sand, mud etc from the bore well complete.( Disconnecting and lifting out of existing submerssible pumpst from borewell upto 10 HP capacity along with their column pipe and submerssible cable from borewell from any depth and lowering after flushing existing borewell included the item rate
Overhauling of air compressor coupled with blower motor 15 HP capacity installed at IFS complete including necessary arrangement of transporting to workshop for re-grinding of shaft ,oiling , greasing etc and necessary replacement of wornout bolts ,nuts , washers etc .Re-assembling the compressure with blower motor , commissioning and testing to the entire satisfaction of Engineer-in-charge .Note:- Spare required for overhauling shall be measured and paid separately under relevant item of schedule as supply only
Supply only in replacement of gear box of Make - USHA as per existing sample as per site requirement all as specified and directed by Engineer-in-charge .
Supply and filling compressure oil all as specified and directed by Engineer-in-charge .
Material & labour for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plante not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300mmx300mmx300mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM1:4 funnel with wire gauge of 22 gauge 8 mesh per liner inch, 80mm thick PCC pit cove 320mmx320mm of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with XPM, Jali and charcoal dust and common salt all as shown in electrical plate No 3 of MESS SR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete all exacation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified and directed by Engineer-in-charge.
Material & Labour for painting to existing centrifugal motor & pumping set complete including base frame with super enameled paint of existing colour coat by spray painting and writing of SM/MES No with white paint, 30 to 50 HP capacity all as specified
All as per item No 106 above but 15 to 25 HP capacity complete all as specified and directed
All as per item No 106 above but 3 to 5 HP capacity complete all as specified and directed
Servicing of liquid chlorine dosing system, any make, any type/capacity complete including replacement of chlorine dosing pipe upto 2.5 mtr length for each plant including servicing of motor, washing of chlorine tank with descaling agent and re-commissioning testing of plant complete all as specified and directed
Supply & fixing in replacement of phase sequence corrector 3 phase 415 volts with time delay relay with and including input supply, reverse phase protection against single phasing, voltage unbalancing, low voltage, hnigh voltage etc with necessary copper connections all as specified and directed.Make: SECO Model RPC-07 or equivalent in L&T/Legrand
Supply & fixing for lead acid battery 12 volts 180 AH of existing type & size suitable for Gen sets 15 to 125 KVA. Make: Exide/Amron/Luminous including initial charging and copper connector complete all as specified and directed by Engineer-in-charge
Material & Labour for painting to existing LT panels, indoor type installed at various pump houses with supper enameled paint of approved colour on exposed surface including preparation of surfaces and applying primer coat complete all as specified and directed by Engineer-in-charge
All as per item No 112 above but borewell panels (out door type) all as specified and directed
Supply & fixing in replacement for aluminium conductor cable 50 sqmm, 3.5 core/4 core LT underground cable complete including dismantling the old burnt cable of existing panel including necessary replacement of aluminium lugs of suitable size with washers complete all as specified and directed by Engineer-in-charge
All as per item No. 114 here in before but 95sqmm ,3.5 core
Supply and fixing BI metallic over load relay, range 28-42 amp rating for automatic starters complete all as specified and directed by Engineer-in-chargeMake: Legrand/LT /C&S/Havels.
All as per item No 116 above but 20-32 Amps complete all as specified and directed by Engineer-in-charge
All as per item No 116 above but 13-21 amp complete all as specified and directed by Engineer-in-charge
All as per item No 116 above but 9-14 Amps complete all as specified and directed by Engineer-in-charge
Supply laying and connecting in replacement of GI earth strip of size 32x6 mm by means of GI bolts, buts and washers all as specified ion repairs complete all as specified
Supply & fixing in replacement for power contactors 32 Amps, 415 volts AC operated 3 phase ML-1.5 or as per existing complete including taking down the existing all as specified and directed. Make: L&T/Legrand/Havels
All as per item No 123 above but 70 Amps, ML-4 all as specified and as directed
All as per item No 123 above but 40 ML-3 Amps all as specified and as directed
All as per item No 123 above but 110 Amps MNX type contractor complete all as specified and as directed
All as per item No 123 above but 32-63 Amps MNX type contractor complete all as specified and as directed
Supply & fixing in replacement for power contactors 40 Amps, 415 volts AC operated 3 phase ML-3 or as per existing complete including taking down the existing all as specified and directed. Make: L&T/Legrand/Havels
Supply & fixing in replacemtn for power contactors 40 Amps, 415 volts AC operated 3 phase ML-2 or as per existing complete including taking down the existing all as specified and directed. Make: L&T/Legrand/Havels.
Disconnecting Existing defective voltage stabilizer at different location of 15 KVA capacity 3 phase 415 volts from electric mains Isolating the naked connections , removing from foundations by unscrewing the nuts bolts etc carrying to the factory /workshop for repair by draining out the transformer oil through the drain plug , dismantling both nut and bolt and lifting the top portion to carry out through inspection and clean the bottom portion of the voltage stabiliser tank by removing the mud and slurry and deposited material for prevention of short circuit and Refixing in Original position after Repair and testing complete all as specified and as directed by Engineer -in - charge .(replacement of defective parts included in this item)
All as per item No 130 above but 100 kVA complete all as specified and as directed
S&F in replacement of Electronic circuit card (PCB) . Suitable for Existing Make - Volina
S&F in replacement of PCB Holder .Suitable for Existing Make - Volina
S&F in replacement of rotary switch 5 Amps for RYB Phase .
S&F in replacement of Micro processor based control card for Each phase ( Set of Three ).Suitable for Existing Make - Volina
S&F in replacement of Dimmer state unit 10 Amps suitable for Existing Make - Volina
S&F in replacement of Dimmer state unit 60 Amps suitable for Existing Make - Volina
S&F in replacement of Digital Amp Meter with CTs suitable for Existing Make - Volina
S&F in replacement of voltmeter 0-500 Volts digital type suitable for Existing Make - Volina
S&F in replacement of Panel lamp as per Existing ( set of three ).
Supply and filling Transformer Oil for top up as required suitable for voltage stabilizer all as specified and directed . Make : Power oil /Savita/ M&I Material/Power Link
M&L for Preparation of old painted surface of Servo Voltage stabiliser by scrapping / removing old paint , dirt etc, and spray painting with two coats of blue synthetic enamel paint over a coat of primer including writing of MES / SM No of capacity 15 KVA all as specified and directed by Engineer-in-charge .
M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
S&F in replacement water proof joint for submersible cable suitable for size 4/6 sqmm 3.5/4 core complete all as specified and directed by Engineer-in-charge
S&F in repair clamps fabricated out of 100mmx6mm MS flat for 80mm bore column pipe alongwith bolts nuts and washers complete all as specified and directed by Engineer-in-charge
S&F in repair bore well cap fabricated out of 4mm thick MS plate incuding MS bolts nuts and washers suitable for 6" to 12" inch dia bore complete all as specified and directed by Engineer-in-charge
S&F in replacement butterfly valve PN 1.6 with lever and handle size 50 mm dia Isi marked complete all as specified and directed by Engineer-in-charge. Make- Audco / Kartar / L&T/Bir
S&F in replacement butterfly valve with lever size 80mm dia ISI marked complete all as specified and directed by Engineer-in-charge. Make- Audco / Kartar / L&T
S&F in replacement and connecting direct on line (DOL) starter in sheet steel enclosure 7.5 HP MK-IDOL 3 phase 415 volts relay range 9-14 amps complete all as specified and as directed by Engineer-in-charge. Make : Havels/L&T/Schiender.
Supply & fixing in replacement of CI impeller with key and nut for 5 to 7.5 HP pump set complete all as specified and as directed by Engineer-in-charge
S & F in replacement of Cast iron shaft sleeves to be filled for 40 to 50 HP motor complete all as specified and as directed by Engineer-in-charge
S & F in replacement of CI centre ring for40 to 50 HP
S & F in replacement of cast iron casing wear ring for40 to 50 HP
S & F in replacement of stuffing box bush for 40 to 50 HP
S & F in replacement of Cast iron bearing housing box for 40 to 50 HP
S & F in replacement of CI Impeller with key, water, deflector, stud, MS bolts & nuts for 40 to 50 HP motor as per size requirement (1/2x2",5/8x2.5") MS stud 19x65mm) complete all as specified and directed by Engineer-in-charge.
Supply & Fixing type coupling for 40 to 50 HP complete all as specified and directed by Engineer-in-charge
S & F in replacement of gun metal sleeves for 40 HP to 50 HP
S&F in replacement strainer of dozing pump all as specified and directed
S&F in replacement suction and delivery tube PVC 12mm dia suitable for dozing pump
JAIPAL and BROS
M/S Anand Enterprises
Surjit and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .