Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAdmitted-Finance 1 11 250 A MATARANI SENSATION LANE BESIDES SYNDICATE BANK BEGUMPET HYDERABAD 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | L1 | Admitted-Finance | |
| 2 | L2₹75.6 L+₹69.2 L (1084.0%)Admitted-Finance 3RD FLOOR BESTECH BUSINESS TOWER BESTECH TOWER SOHNA ROAD IIIRD FLOOR SECTOR 48 GURUGRAM CT00000131 GURGAON HARYANA 122018 | GURUGRAM | HARYANA | 122018 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical 1241 4TH FLOOR SOLITAIRE CORPORATE PARK BUILDING NUMBER 12 ANDHERI GHATKOPAR LINK ROAD ANDHERI EAST | - | Rejected-Technical technically unfit | |
| 4 | Rejected-Technical 1 MOON PALACE COLONY 1 MOON PALACE COLONY 989 INDORE MADHYA PRADESH 452009 | INDORE | MADHYA PRADESH | 452009 | - | Rejected-Technical technically unfit |
| Sl No | Description | Qty | Unit | BOSTON SCIENTIFIC INDIA PRIVATE LIMITED L2 | M/s St Jude Medical India Pvt Ltd L1 |
|---|---|---|---|---|---|
| 1.00Rate contract of Pacemaker and electro physiological study related cardiac items :- | |||||
| 1.01 | Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Life long battery warranty
• Auto capture mode
• Minimize ventricular pacing mode
• Hysteresis mode
• Pacemaker lead profile should be
maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr.
peel away sheath
• 3.0 T MRI compatible (full body)
• USFDA/PMDA approved | 1 | Each | 1,06,000 ₹1,06,000 Lowest | - |
| 1.02 | Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Life long battery warranty
• Auto capture mode
• Minimize ventricular pacing mode
• Hysteresis mode
• Pacemaker lead profile should be
maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr.
peel away sheath
• 3.0 T MRI compatible (full body)
• CE approved | 1 | Each | 1,06,000 ₹1,06,000 Lowest | - |
| 1.03 | Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Life long battery warranty
• Auto capture mode
• Minimize ventricular pacing mode
• Hysteresis mode
• Pacemaker lead profile should be
maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr.
peel away sheath
• 3.0 T MRI compatible (full body)
• DCGI approved | 1 | Each | 1,06,000 ₹1,06,000 Lowest | - |
| 1.04 | Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Auto capture mode
• Minimize ventricular pacing mode
• Hysteresis mode
• Pacemaker lead profile should be
maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr.
peel away sheath
• 1.5T and above MRI compatible (full body)
• USFDA/PMDA approved | 1 | Each | 1,06,000 ₹1,06,000 Lowest | - |
| 1.05 | Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Auto capture mode
• Minimize ventricular pacing mode
• Hysteresis mode
• Pacemaker lead profile should be
maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr.
peel away sheath
• 1.5 T and above MRI compatible (full body)
• CE approved | 1 | Each | 1,06,000 ₹1,06,000 Lowest | - |
| 1.06 | Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Auto capture mode
• Minimize ventricular pacing mode
• Hysteresis mode
• Pacemaker lead profile should be
maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr.
peel away sheath
• 1.5 T and above MRI compatible (full body)
• DCGI approved | 1 | Each | 1,06,000 ₹1,06,000 Lowest | - |
| 1.07 | Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Life long battery warranty
• Auto capture mode
• Minimize ventricular pacing mode
• Beat to Beat capture mechanism
• AF suppression
• Optimization of AV delay
• Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• USFDA/PMDA approved | 1 | Each | 1,56,442 ₹1,56,442 Lowest | - |
| 1.08 | Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Life long battery warranty
• Auto capture mode
• Minimize ventricular pacing mode
• Beat to Beat capture mechanism
• AF suppression
• Optimization of AV delay
• Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• CE- approved | 1 | Each | 1,56,442 ₹1,56,442 Lowest | - |
| 1.09 | Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr.
• Screw in and tined lead as per operator’s preference
• Life long battery warranty
• Auto capture mode
• Minimize ventricular pacing mode
• Beat to Beat capture mechanism
• AF suppression
• Optimization of AV delay
• Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• DCGI -approved | 1 | Each | 1,56,442 ₹1,56,442 Lowest | - |
Tender Value
₹4 Cr
EMD Value
₹8 L
Closing Date
16 Jun 2025, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MEMBER SECRETARY
SSH HOSPITAL RNT MEDICAL COLLEGE
RATE CONTRACT OF PACEMAKER AND ELECTROPHYSIOLOGICAL STUDY RELATED CARDIAC ITEMS
2025_RNTMC_466436_1
6
Open Tender
Machineries
Item Wise
40 days
UDAIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Yes
SSH RNT MEDICAL COLLEGE
₹8 L
Yes
SSH HOSPITAL
11 Jul 2025
9 May 2025
16 Jun 2025
9 May 2025
16 Jun 2025
17 May 2025
10 May 2025
Rate contract of Pacemaker and electro physiological study related cardiac items :-
Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Hysteresis mode • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • USFDA/PMDA approved
Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Hysteresis mode • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • CE approved
Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Hysteresis mode • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • DCGI approved
Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Hysteresis mode • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5T and above MRI compatible (full body) • USFDA/PMDA approved
Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Hysteresis mode • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) • CE approved
Single Chamber Pacemaker (VVIR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Hysteresis mode • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) • DCGI approved
Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • USFDA/PMDA approved
Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • CE- approved
Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • DCGI -approved
Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) • USFDA/PMDA - approved
Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) • CE - approved
Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) • DCGI- approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • USFDA/PMDA-approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • CE -approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Life long battery warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • DCGI -approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) • USFDA/PMDA-approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) • CE-approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. • Screw in and tined lead as per operator’s preference • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) • DCGI-approved
Single Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead should be compatible with 8 Fr. Peel away Sheath • Small size below 35cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends with Alerts • 40J delivered energy with programmable Tilt and pulse width programming • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave overspending • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert • Facility of specially coated Device for avoiding lead abrasion • Proactive Measurement of ST Segment changes with Alerts • USFDA/PMDA approved
Single Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead should be compatible with 8 Fr. Peel away Sheath • Small size below 35cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends with Alerts • 40J delivered energy with programmable Tilt and pulse width programming • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave overspending • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert • Facility of specially coated Device for avoiding lead abrasion • Proactive Measurement of ST Segment changes with Alerts • CE-approved
Single Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead should be compatible with 8 Fr. Peel away Sheath • Small size below 35cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends with Alerts • 40J delivered energy with programmable Tilt and pulse width programming • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave overspending • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert • Facility of specially coated Device for avoiding lead abrasion • Proactive Measurement of ST Segment changes with Alerts • DCGI-approved
Dual Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead profile: should be maximum up to 5 .8 Fr. And lead should be compatible with 6 Fr. peel away sheath • Small size below 35cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • 40J delivered energy with programmable Tilt and pulse width programming. • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert • Proactive Measurement of ST Segment changes with Alerts • Facility of specially coated Device for avoiding lead abrasion (optional) • USFDA/PMDA approved
Dual Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead profile: should be maximum up to 5 .8 Fr. And lead should be compatible with 6 Fr. peel away sheath • Small size below 35cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • 40J delivered energy with programmable Tilt and pulse width programming. • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert • Proactive Measurement of ST Segment changes with Alerts • Facility of specially coated Device for avoiding lead abrasion (optional) • CE- approved
Dual Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead profile: should be maximum up to 5 .8 Fr. And lead should be compatible with 6 Fr. peel away sheath • Small size below 35cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • 40J delivered energy with programmable Tilt and pulse width programming. • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert • Proactive Measurement of ST Segment changes with Alerts • Facility of specially coated Device for avoiding lead abrasion (optional) • DCGI - approved
Cardiac Resynchronization Pacemaker with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • Electrocardiogram based AV Optimization for suggesting optimized AV Delays • warranty : Minimum 5 years on Device • Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead • Programmable AT/AF Alerts with AF Burden trending • Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF • Facility of RF Telemetry • Should be supplied with 6 compatible leads and Introducers for RA & RV • LV lead delivery systems should be compatible with 7 Fr. EP catheters optional • USFDA /PMDA approved
Cardiac Resynchronization Pacemaker with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • Electrocardiogram based AV Optimization for suggesting optimized AV Delays • warranty : Minimum 5 years on Device • Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead • Programmable AT/AF Alerts with AF Burden trending • Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF • Facility of RF Telemetry • Should be supplied with 6 compatible leads and Introducers for RA & RV • LV lead delivery systems should be compatible with 7 Fr. EP catheters optional
Cardiac Resynchronization Pacemaker with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • Electrocardiogram based AV Optimization for suggesting optimized AV Delays • warranty : Minimum 5 years on Device • Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead • Programmable AT/AF Alerts with AF Burden trending • Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF • Facility of RF Telemetry • Should be supplied with 6 compatible leads and Introducers for RA & RV • LV lead delivery systems should be compatible with 7 Fr. EP catheters optional • DCGI - approved
Cardiac Resynchronization defibrillator with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • 40J delivered energy • Pulse width and Tilt : Programmable as per DFT • Heart Failure Congestion Monitoring Trends with Alerts • Small size below 35cc • Warranty : Minimum 5 years • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing (optional) • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional • Facility of specially coated Device for avoiding lead abrasion (optional) • USFDA /PMDA approved
Cardiac Resynchronization defibrillator with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • 40J delivered energy • Pulse width and Tilt : Programmable as per DFT • Heart Failure Congestion Monitoring Trends with Alerts • Small size below 35cc • Warranty : Minimum 5 years • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing (optional) • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional • Facility of specially coated Device for avoiding lead abrasion (optional) • CE - approved
Cardiac Resynchronization defibrillator with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • 40J delivered energy • Pulse width and Tilt : Programmable as per DFT • Heart Failure Congestion Monitoring Trends with Alerts • Small size below 35cc • Warranty : Minimum 5 years • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing (optional) • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional • Facility of specially coated Device for avoiding lead abrasion (optional) • DCGI - approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. –with conduction system pacing (CSP) • Screw in and tined lead as per operator’s wish • Life long battery warranty. • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • USFDA/PMDA-approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. –with conduction system pacing (CSP) • Screw in and tined lead as per operator’s wish • Life long battery warranty. • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • CE-approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. –with conduction system pacing (CSP) • Screw in and tined lead as per operator’s wish • Life long battery warranty. • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 3.0 T MRI compatible (full body) • DCGI-approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. –with conduction system pacing (CSP) • Screw in and tined lead as per operator’s wish • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) USFDA/PMDA-approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. –with conduction system pacing (CSP) • Screw in and tined lead as per operator’s wish • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body) CE -approved
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. –with conduction system pacing (CSP) • Screw in and tined lead as per operator’s wish • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism • AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr. • Lead should be compatible with 6 Fr. peel away sheath • 1.5 T and above MRI compatible (full body)
CRT-P with conduction system pacing (CSP) – with all accessories CRT-P with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • Electrocardiogram based AV Optimization for suggesting optimized AV Delays • warranty : Minimum 5 years on Device • Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead • Programmable AT/AF Alerts with AF Burden trending • Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF • Facility of RF Telemetry • Should be supplied with 6 compatible leads and Introducers for RA & RV • LV lead delivery systems should be compatible with 7 Fr. EP catheters optional • USFDA /PMDA approved
CRT-P with conduction system pacing (CSP) – with all accessories CRT-P with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • Electrocardiogram based AV Optimization for suggesting optimized AV Delays • warranty : Minimum 5 years on Device • Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead • Programmable AT/AF Alerts with AF Burden trending • Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF • Facility of RF Telemetry • Should be supplied with 6 compatible leads and Introducers for RA & RV • LV lead delivery systems should be compatible with 7 Fr. EP catheters optional • CE- approved
CRT-P with conduction system pacing (CSP) – with all accessories CRT-P with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • Heart Failure Congestion Monitoring Trends with Alerts • Facility for overdriving Atrium for prevention of Atrial Arrythmias • Electrocardiogram based AV Optimization for suggesting optimized AV Delays • warranty : Minimum 5 years on Device • Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead • Programmable AT/AF Alerts with AF Burden trending • Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF • Facility of RF Telemetry • Should be supplied with 6 compatible leads and Introducers for RA & RV • LV lead delivery systems should be compatible with 7 Fr. EP catheters optional • DCGI- approved
CRT-D with conduction system pacing (CSP) – with all accessories CRT-D with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • 40J delivered energy • Pulse width and Tilt : Programmable as per DFT • Heart Failure Congestion Monitoring Trends with Alerts • Small size below 35cc • Warranty : Minimum 5 years • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing (optional) • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional • Facility of specially coated Device for avoiding lead abrasion (optional) • USFDA/PMDA- approved
CRT-D with conduction system pacing (CSP) – with all accessories CRT-D with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • 40J delivered energy • Pulse width and Tilt : Programmable as per DFT • Heart Failure Congestion Monitoring Trends with Alerts • Small size below 35cc • Warranty : Minimum 5 years • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing (optional) • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional • Facility of specially coated Device for avoiding lead abrasion (optional) • CE- approved
CRT-D with conduction system pacing (CSP) – with all accessories CRT-D with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath • 40J delivered energy • Pulse width and Tilt : Programmable as per DFT • Heart Failure Congestion Monitoring Trends with Alerts • Small size below 35cc • Warranty : Minimum 5 years • Facility of Changing the shocking vector based on Over Current sensing • Special Sensing filter protection for T Wave over sensing (optional) • Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional • Facility of specially coated Device for avoiding lead abrasion (optional) • DCGI - approved
Pacemaker lead with peel away sheath only (without pulse generator) for the existing company providing complete pacemaker at RNT medical college • USFDA /PMDA - approved
Pacemaker lead with peel away sheath only (without pulse generator) for the existing company providing complete pacemaker at RNT medical college • CE - approved
Pacemaker lead with peel away sheath only (without pulse generator) for the existing company providing complete pacemaker at RNT medical college • DCGI - approved
LONG SHEATHS/INTRODUCERS - PREFACED VALVED LONG SHEATHS FOR RFA WITH MULLINS CURVE, MULTIPURPOSE CURVE, OTHER CURVES, 7F TO 9F, ATLEAST 80- CM LONG, 0.038 WIRE COMPATIBLE
LONG SHEATHS/INTRODUCERS - BRITE TIP INTERVENTION SHEATHS WITH TIP VISUALIZATION, KINK RESISTANT, COLD SHAPABLE WITH SILICON COATING
LONG SHEATHS/INTRODUCERS - BRITE TIP INTERVENTION SHEATHS WITH TIP VISUALIZATION, KINK RESISTANT, COLD SHAPABLE WITH SILICON COATING
LONG SHEATHS/INTRODUCERS - LONG SHEATHS (PEEL AWAY, SLITTABLE, WITH BREAKING VALVE) FOR SPECIAL APPLICATIONS LIKE CORONARY SINUS INTUBATION, LATERAL VEIN, SPECIAL CURVES LIKE RENAL, HOOK SHAPE etc
LONG SHEATHS/INTRODUCERS - PEEL AWAY INTRODUCER SHEATHS WITH BREAK AWAY HWMOSTATIC VALVES FOR PACING LEADS, 5F-12cm, OPTIONAL INFUSION SIDE PORT, RADIO-OPAQUE DISTAL TIP AND MULTIPLE CURVES
PACING LEAD STABLIZERS-
SURFACE PATCH FOR 3 D MAPPING – (ADULT & PEDIATRIC)
LONG SHEATHS/INTRODUCERS - PREFACED VALVED LONG SHEATHS FOR RFA WITH MULLINS CURVE, MULTIPURPOSE CURVE, OTHER CURVES, 7F TO 9F, ATLEAST 80- CM LONG, 0.038 WIRE COMPATIBLE
LONG SHEATHS/INTRODUCERS - BRITE TIP INTERVENTION SHEATHS WITH TIP VISUALIZATION, KINK RESISTANT, COLD SHAPABLE WITH SILICON COATING
LONG SHEATHS/INTRODUCERS - INTRODUCER SHEATHS FOR ELECTROPHYSIOLOGY, WITH VARIOUS SWARTZ CURVES SL 0-4, SR 0-4, 8F, 8.5F , 9F
BALLOON CATHETER FOR NON-CONTACT 3 D MAPPING
DIAGNOSTIC EP CATHETERS - The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable. All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur Configurations would be Pole, French. Curve of catheter, Electrode configuration, Fixed / deflectable
WOVEN EP DIAGNOSTIC CATHETERS – (woven material with braided conducting wire, ensuring prolonged stability) The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable. All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur Quadripolar, 5-7, Josephson, 2-5-2-5, Fixed
CABLES FOR EP & RFA – The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable. All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur Quadripolar Cable, Compatible with Quardripolar Catheter
CABLES FOR EP & RFA – The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable. All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur Decapolar Cable, Compatible with Decapolar Catheter
CABLES FOR EP & RFA – The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable. All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur Hexapolar Cable, Compatible with Hexapolar Catheter
Bi-Directional Steerable Catheters Handle- Thumb Wheel or Push Pull Automatic Curve Lock Mechanism Electrode – Stainless Steel, Platinum, Palladium Quality Approval – - Description Size(Fr) Electrode Spacing(mm) Curve, Small, Large 4.0
Dual Curve RF Ablation Catheter Bi-Directional Steerable Electrode – Stainless Steel, Platinum, Palladium Quality Approval – - Description Size(Fr) 7.8 Fr Electrode Spacing(mm) 2-5-2 mm Curve,Medium,,Large,,Extra Large
ABLATION CATHETERS (ITEMS 1-10) - (ALL SIZES 4F TO 8.5F, ALL CURVES A-K, 270, all electrode sizes and spacing, e.g.) (ALL ITEMSS DIFFERING IN MAKE/PRICES NEED TO BE MENTIONED SEPERATELY. Quote separately if different in terms of material, braiding, electrode material Platinum, Palladium or stainless steel etc) QUOTE WITH APPROPRIATE CONNECTOR TO EXISTING EPT 1000 AND STOCKERT ABLATORS. EPT 1000 is not compatible with Thermocouple and appropriate catheters/ connectors should be quoted. Thermistor catheters would therefore by preferred. In addition give prices of ALL CONNECTOR CABLES / ACCESSORIES SEPERATELY. All items should be compatible with existing EP Tracer machine in RNT Medical College, Udaipur Type Ablation Catheter Regular Tip Size 4 mm Diameter 6-8F Curves/Reach All (Equivalent to A-F, J, K, 270) Comments
BALLOON CATHETER FOR NON-CONTACT 3 D MAPPING
ABLATION CATHETERS (ITEMS 1-10) - (ALL SIZES 4F TO 8.5F, ALL CURVES A-K, 270, all electrode sizes and spacing, e.g.) (ALL ITEMSS DIFFERING IN MAKE/PRICES NEED TO BE MENTIONED SEPERATELY. Quote separately if different in terms of material, braiding, electrode material Platinum, Palladium or stainless steel etc) QUOTE WITH APPROPRIATE CONNECTOR TO EXISTING EPT 1000 AND STOCKERT ABLATORS. EPT 1000 is not compatible with Thermocouple and appropriate catheters/ connectors should be quoted. Thermistor catheters would therefore by preferred. In addition give prices of ALL CONNECTOR CABLES / ACCESSORIES SEPERATELY. All items should be compatible with existing EP Tracer machine in RNT Medical College, Udaipur Type Ablation Catheter Irrigated Tip(Open) Tip Size Any Diameter 7-9F Curves/Reach All Curves/Reach Comments
CATHETERS, CABLES, ACCESSORIES FOR ENDOCARDIAL SOLUTIONS (ESI) ACCESSORIES
REUSABLE DEFIBRILLATION/TRANSCUTANEOUS PACING PATCHES (suitable for Equipment in .)
CRYO CATHETERS (AND ACCESSORIES)FOR ABLATION OF ARRHYTHMIAS IN CHILDREN AND ADULTS –
BOSTON SCIENTIFIC INDIA PRIVATE LIMITED (BID ID -3182441)
M/s St Jude Medical India Pvt Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
cardoi.pdf
Tender Documents • 12.41 MB
BOQ_835764.xls
BOQ • 0.37 MB
BOQ.xls
BOQ • 0.37 MB
Tenderdocument.pdf
Tender Documents • 12.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .