Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Technically disqualified |
| 4 | Rejected-Technical H NO 2 BYE LANE 02 LICHUBAGAN HENGRABARI GUWAHATI 781036 | KAMRUP METRO | ASSAM | 781036 | Rejected-Technical Technically disqualified |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
2 Apr 2025, 2:00 pmClosed
Director
NIT Meghalaya, Sohra Campus Meghalaya 793108
As per tender document
2025_NITM_853012_1
NITMGH/EN/31/2024-25/127
Open Tender
Electrical Works
30 days
NIT Meghalaya, Sohra Campus
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹30,000
Yes
10 Apr 2025
12 Mar 2025
3 Apr 2025
12 Mar 2025
2 Apr 2025
12 Mar 2025
Amount
Wiring in looping system with copper PVC cable 250/440 volt grade of size 1.5 sqmm of approved quality using PVC casing capping including 5 ampere switch and Socked, box and cover plate best quality to a light plug point when fixed elsewhere a)Long Point wiring upto 10 meter
Wiring in looping system with copper PVC cable 250/440 volt grade of size 1.5 sqmm of approved quality using PVC casing capping including 5 ampere switch and Socked, box and cover plate best quality to a light plug point when fixed elsewhere b) Medium Point wiring upto 6 meter
Wiring in looping system with copper PVC cable 250/440 volt grade of size 1.5 sqmm of approved quality using PVC casing capping including 5 ampere switch and Socked, box and cover plate best quality to a light plug point when fixed elsewhere c) Short Point wiring upto 3 meter
Wiring in looping system with copper PVC cable 250/440 volt grade of size 1.5 sqmm of approved quality using PVC casing capping including with supplying and fitting of 5 Amp modular switch socket combined with continuous earth wire to a light plug point when fixed on the same board
Drawing of main and sub main line with DGSD approved VIR or PVC 250/440 Volt grade copper conductor in PVC casing capping complete with all acccessories a) with 2x4 sqmm copper conductor
Drawing of main and sub main line with DGSD approved VIR or PVC 250/440 Volt grade copper conductor in PVC casing capping complete with all acccessories b) with 2x6 sqmm copper conductor
Copper wiring in existing casing capping/regid PVC pipe/ Conduit With 3x1.5 sqmm PVC Copper Wire
Drawing of 3 phase main line 4 wire with DGSD approved VIR or PVC cable 660 volt grade copper conductor in casng capping with all accessories with 4x6 sqmm copper conductor
Supplying & fixing of Load Kontaket Miniature Circuit Breakers DX3 MCB's for AC application till 63 A. With Single Pole 240/410 V, 6-32 Amp
With Triple pole + Nuetral 415 V, 6-32 Amp
Supplying fitting and fixing of DX3 Isolator for AC application upto 125 A a) With Four Pole 415 V , 40 A
Supplying fitting and fixing of DX3 Isolator for AC application upto 125 A b) With Double Pole 240 V, 40 A
Supplying fitting & fixing of Distribution Board ETPN DB's for MCB Isolator RCCB & RCBO With IP 30 - #1K08 a) 4 way 8+12 Module
Supplying fitting & fixing of Distribution Board ETPN DB's for MCB Isolator RCCB & RCBO With IP 30 - #1K08 b) 4 way 8+24 Module
Supplying fitting & fixing of Distribution Board Duo Boxx With Transperant Crystal Door a) 1 way 12 Module
Supplying fitting & fixing of Distribution Board Duo Boxx With Transperant Crystal Door b) 1 way 8 module
Supplying fitting & fixing of Distribution Board Duo Boxx With Transperant Crystal Door c) 1 way 6 Module
Providing laying connecting testing and commissioning of the following sizes of 1100V PVC/XLPE armoured cables with aluminium conductor as per ISI code in bracket, trenches, M.S cable rods and including the cost of digging of trenches, sand cushioning with laying etc and refilling the same in layers or by supporting them in walls and all accessories as required. a) with 3.5 core 25 sqmm
Providing laying connecting testing and commissioning of the following sizes of 1100V PVC/XLPE armoured cables with aluminium conductor as per ISI code in bracket, trenches, M.S cable rods and including the cost of digging of trenches, sand cushioning with laying etc and refilling the same in layers or by supporting them in walls and all accessories as required. b) with 3.5 core 35 sqmm
Wiring in looping system with copper PVC cable 250/440 volt grade of size 4 sqmm of approved quality using PVC casing capping including 16 ampere switch and Socked, box and cover plate best quality to a Power plug point when fixed elsewhere. a) Long Point wiring upto 10 meter
Wiring in looping system with copper PVC cable 250/440 volt grade of size 4 sqmm of approved quality using PVC casing capping including 16 ampere switch and Socked, box and cover plate best quality to a Power plug point when fixed elsewhere. b) Medium Point wiring upto 6 meter
TAIBIN WARJRI (BID ID -3195749)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid