| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC FLAT NO 8 205 SNO 296 2 DIVINE HOMES PORWAL ROAD KSHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.5 L+₹1.4 L (6.86%)Rejected-Finance | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹23.3 L+₹3.2 L (15.7%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹25.3 L+₹5.1 L (25.5%)Rejected-Finance | L4 | Rejected-Finance not being lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Repairs to WPT, mangalore tiles roof etc in MD accn at CME
2022_MES_529109_3
8326/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D, category a(i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (CME) Kirkee
₹70,000
Yes
3 Nov 2022
16 Aug 2022
31 Aug 2022
16 Aug 2022
29 Aug 2022
17 Aug 2022
Amount
Removing existing/old damaged roof treatment of any (Brick tiles and Mudfuska) description by scrapping with using wire brush and removing the same from the site(s) to outside MD land, complete all as specified and as directed by Engr-in-Charge. Note: Dismantling all water tanks carefully and after roof treatment connect all tanks during working time. If any tanks, float valves and GI pipes damaged, contactor should replace the same (upto all storeys) without any extra cost.
M&L for roof treatment on existing concrete surfaces with the following specifications:– (a) Rendering 10mm thick in cement mortar 1:4 including mixing of water proofing compound (WPC) as per manufacturer’s instructions on cleaned concrete surfaces of roof after applying a neat cement slurry @ 3.0 KILO-GRAM PER SQUARE METRE, plastered surfaces fair finished including curing of plastered surfaces for 7 DAYS by ponding of water over the roof (levelling course) and applying two coats of DR fixit coat over cement plaster (b) Applying evenly one coat of cold bituminous primer conforming to IS-3384-1986 @ 0.30 LITRE PER SQUARE METRE on the cleaned plastered surfaces. (c) Only a coat of blown hot bitumen of grade 85/25 @ 1.20 KILOGRAM PER SQUARE METRE on primed surfaces. (d) Applying a layer of APP based polymeric membrane, 3.0mm thick (minimum) weighing 3.0 KILOGRAM PER SQUARE METRE (reinforced) with polyester Non woven fabric weighing not less than 160 GRAM PER SQUARE METRE by torch application. The overlap shall be minimum 100mm on traverse direction and 75mm on longitudinal direction and sealing overlap. (e) Applying evenly one coat of aluminium paint @ 0.10 LITRE PER SQUARE METRE over the APP based polymeric membrane. (f) PCC 1:2:4 type BO using 12.5mm graded stone aggregate for filleting and benching slightly rounded or chamfered on edges.
Surface preparation: Minor cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SmartCare SRP Making of angle fillets all around the periphery of the wall with polymer modified mortar using SmartCare SRP (Smartcare Repair Polymer).
Pipe Downrake Treatment: Supplying & grouting the gaps around the pipe/ inserts with SmartCare General Purpose Grout, a non shrink cementitious waterproof grout. The "Nahani" trap, etc. is to be fitted securely in the same manner & the gaps around it to be grouted with non shrink Grout. This shall conform to the following standards. ASTM C 109-1999 18, ASTM C 1107, Grade C complete as per instructions. Providing 3 coats of SmartCare ultron and 40-50 gms polyester fleece sandwitched between 1st & 2nd coats completely up to the top edge of the pipe etc. complete as per manufacturer's instructions.
Waterproofing coating : Supplying and applying high performance hybrid polyurea elastomeric waterproofing coating cold applied of spray/brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, 1 Coat of SmartCare epoxy primer application @150 gm per Sqm and applying SmartCare Ultron in two coats at 1.2 kg per sqm etc, complete as per manufacturer specification.
Notes: The application must be done by authorised applicator agency registered in SmartAssure service. The 10 year warranty documents needs to be submitted by such an applicator on Rs. 500 Non-judicial stamp paper.
All as per item No. 3, 3.1, 3.2 & 3.3 above, over the below specified work only where slope making is required: Separation Layer: Loosely lay 150 GSM Geotextile (non-woven polyester) with a min of 100mm wide overlap after which drain boards and soiling can be allowed. Protective screed: Laying protective screed of average thickness 75mm, M20 grade with slope 1:100 containing 12mm, 100% virgin polypropylene fibres @0.9 Kg per Cu. mt with a broom finish, well compacted, curing for 7 days etc.
Dismantling tiling of single layer Mangalore Pattern roof tile laid dry complete all as specified and directed.
All as per item No.5 above, but bedded in lime or cement mortar complete all as specified and directed.
M&L for roof tiles, Mangalore Pattern, interlocking at side joints laid dry complete all as specified and directed.
All as per item No.7 above, but except tile complete
M&L for ridge tiles, Mangalore Pattern, set and jointed in CM 1:6 complete all as specified and directed.
All as per item No.9 above, but except Mangalore Pattern ridge
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spacing exc 15 cm complete all as specified and directed.
M&L 2nd class hardwood clean sawn battens at 30cm centres of sectional area exc 5 & n.exc 15 sqcm complete all as specified and directed.
All as per item No.12 above, but except battens
Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete all as specified and directed.
M&L second class hard wood clean sawn in scantling fixed in framed work complete all as specified and directed.
Dismantling boarding, any description in any position with nails complete all as specified
M&L 2nd class hardwood clean sawn weather boarding, plain, 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and directed.
M&L for preparing the surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
M&L for preparing the surfaces of tiles batten any size and spacing prepared and treated all over (measured overall on one side only), spaces not deducted with two coats of creosote oil complete all as specified and directed.
All as per item No.19 above, but one coat on old batten surface
M&L for preparing new surface of wood of any decription, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F 750 Ltr capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including dismantling/demolition (PVC/RCC/Stone & PCC block masonry) of old unserviceable water tank of capacity exc. 500 & n.exc. 1000 ltrs and 20mm bore dia ball brass valves including rubbish off debris beyond 100 m & n.exc. 250 m complete all as specified and directed.
All as per item No.22 above, but capacity of water storage tank 1000 ltrs complete all as specified and directed.
S&F 0.63mm thick CGI sheeting with two corrugation side lap, fixed with coach screws and washers, in roof, walls etc including dismantling of existing sheet of any description complete all as specified and directed.
S&F 0.63 mm thick plain, galvanised, mild steel sheeting in ridges, hips, valley gutters, drip and straight flashing (length and girth as fixed) with grade of zinc coating 275 including dismantling of existing sheet complete all as specified and directed.
S & F 110 mm dia PVC (SWR) pipes fixed as in spouts including cutting holes and making good and including dismantling of old existing pipe complete all as specified
All as per item No.26 above, but 75mm dia complete all as specified and directed.
S&F in repair 110mm PVC (SWR) bends complete all as specified and directed.
All as per item No.28 above, but 75mm dia complete all as specified and directed.
Taking down cement plaster, any description on brick walls or on concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc., and removing same from the site(s) to outside MD land, complete all as specified and as directed. (all floor and scaffolding)
M&L rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, plastered surfaces finishing fair and even including ceiling and walls (all floor and scaffolding), complete all as specified and as directed.
M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, plastered surfaces finishing fair and even, complete including ceiling and walls (all floor and scaffolding) all as specified and as directed.
M&L for preparing newly plastered surfaces of wall and applying complete wall with 3mm POP/Birla putty and making smooth surfaces and applying two coats of oil bound distemper over a coat of primer all as specified and directed.
M&L preparing newly plastered surfaces of wall and applying complete wall with 3 mm POP/Birla putty for making smooth surfaces and applying two coats of exterior emulsion paint 100% acrylic over a coat of primer all as specified and directed Note : The rate shall be quoted by the contractor including scaffolding to carry out the work for height more than 10.00 mtrs
Demolition of brick work or stone boulder masonry built in cement mortar complete all as specified and directed.
M&L for pre-cast PCC block masonry type C-1, 1:3:6 using 20mm graded stone aggregate exc 10 cm width and set in CM 1:4 complete all as specified and directed.
M & L 15mm thick cement plastering on block/stone masonry surfaces in CM 1:4 finishing the surface even and smooth without using extra cement complete all as specified and directed.
Taking up or down GI steel tubing of 15 mm bore of pipe connections including all fittings or removal all as specified and directed.
Taking up or down GI steel tubing of 20 mm bore of pipe connections including all fittings or removal all as specified and directed.
S & F galvanised iron tubing 15 mm bore of pipe medium grade with and including all fittings & fixed complete to wall & ceiling or laid on floors including clamps all as specified and directed
S & F galvanised iron tubing 20 mm bore of pipe medium grade with and including all fittings & fixed complete to wall & ceiling or laid in floors including clamps all as specified and directed
Refixing old GI tubing 15 mm bore of pipe and fittings, to walls and ceiling or laying in floors in new or old position including cleaning as directed.
Refixing old GI tubing 20 mm bore of pipe and fittings, to walls and ceiling or laying in floors in new or old position including cleaning as directed.
M&L 20mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
Aakar Construction
Mukund Engineers and Contractors
RK CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .